ABC Cable 0.6kv/1kv Aluminium Service Drop Cable

China 
                        ABC Cable 0.6kv/1kv Aluminium Service Drop Cable
                      manufacture and supplier

ABC Cable 0.6kv/1kv Aluminium Service Drop Cable image

Get Latest Price Request a quote

Quick Details

ABC Cable 0.6kv/1kv Aluminium Service Drop Cable

ABC Cable

Huatong

Jklv

ISO, CCC, CE, UL

Aluminium

Round Wire

None

PE

DC & AC

Low and Medium Voltage Cable

Construction, Overhead, Industrial, Power Station

PVC/PE/XLPE

40000m2

HUATONG

Drum

GB/T 12527

China

8544492100

Product Details

Aluminium Service Drop
Aluminium Conductors. Polythylene or Crosslinked Polyethylene Insulation.
ABC Cables Applications:
Used to supply 3 phase power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors. 
ABC Cables Construction:
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR.One conductor is manufactured with an extruded ridge for phase identification.
ABC Cables Standards:
1.B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2.B-231 Aluminum conductors, Concentric-Lay-Stranded.
3.B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
4.B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
5.B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6.Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
ABC Cables Using Properties
1.Rated Voltage:0.6/1kV
2.Cable installation temperature not less than -20°C
3.Max. temperature of cable at short circuit(The max. duration does not exceed 5 minutes)
   For XLPE insulation is 250°C.
   For HDPE insulation is 150 °C.
4.The Max. bending radius of cable shall not be less than 20Dmm(D overall diameter of cable)
Type of ABC Cable
1.Duplex Service Drop:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75 maximum.
2.Triplex Service Drop: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation .
3.Quadruplex Service Drop: Used to supply 3 phase power , usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made . To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.

Code Word

Phase conductor

Bare Neutral Messenger

Nominal Lay Length

Weight Per 1000ft. (lbs.)

Allowable Ampacities+

Size

(AWG)

Stranding

Insul. Thick.

(Mils)

Size

(AWG)

Stranding

Rated Strength

(lbs.)

inches

XLP

POLY

XLP

POLY

AAC Neutral-messenger

Pekingese

6

1

45

6

7

563

10.36

61

61

85

70

Collie

6

7

45

6

7

563

10.36

64

64

85

70

Dachshund

4

1

45

4

7

881

10.36

92

92

115

90

Spaniel

4

7

45

4

7

881

10.36

96

96

115

90

Doberman

2

7

45

2

7

1350

14.88

147

147

150

120

Malemute

1/0

9

60

1/0

7

1990

14.88

234

234

We are China ABC Cable 0.6kv/1kv Aluminium Service Drop Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular ABC Cable Products

LV Duplex Aluminium Conductor XLPE Insulated ABC Cable

ABC Cable Aerial Bundled Cable Overhead Power Cable

ABC Cable Duplex/Triplex/Quadruplex Service Drop Cable

Aerial Bundle Cable, 0.6/1kv XLPE Insulation Aluminum Cable

Single Core/Duplex /Triplex/Quadruplex ABC Cable Aluminum Conductor XLPE Insulation

PE/XLPE Insulated Power Cable ABC Cable 4*50mm2

Popular ABC Cable 0.6kv/1kv Products

ABC Cable 0.6/1kv Aluminium Service Drop Cable

Popular huatongcable Products

Electrical Power Cable 0.6/1kv XLPE Insulation PVC Sheath

AAAC Conductor All Aluminium Alloy Conductor ASTM Standard 600 Mcm

25mm Power Shield Copper Core Cable, XLPE Insulated Power Cable

AAC Bare Conductor BS Standard for Power Transmission Line

Copper Conductor PVC Insulated Thw Wire Building Wire Electric Wire

3 Cores PVC Insualated Flexible Cable

Popular Service Drop Cable Products

Neutral Supported Service Drop Cable

En 50182 Hornet 158-Al1 Overhead Line (AAC) PVC Cable

600/1000V Aluminum Wires with Best Price

ABC Cable Overhead Conductor Cable

Low Voltage Aluminum Conductor PVC Insulation Overhead Electric Transmission Quadruplex Service Drop Aerial Bundled Cable 4X35mm2 ABC Cable

120mm2 Aluminum Sac Cable Service Drop Cable

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION