ABC Cable XLPE Insulation HDPE Sheath/Jacket Sac Single Aluminium Cable

China 
                        ABC Cable XLPE Insulation HDPE Sheath/Jacket Sac Single Aluminium Cable
                      manufacture and supplier

ABC Cable XLPE Insulation HDPE Sheath/Jacket Sac Single Aluminium Cable image

Get Latest Price Request a quote

Quick Details

ABC Cable XLPE Insulation HDPE Sheath/Jacket Sac Single Aluminium Cable

ABC Cable

Huatong

Jkv

ISO, CCC, CE, UL

Aluminium

Round Wire

None

XLPE

DC & AC

Low and Medium Voltage Cable

Construction, Overhead, Industrial, Power Station

Black

PVC/PE/XLPE

40000m2

HUATONG

Drum

GB/T 12527

China

8544492100

Product Details

Aluminium Secondary UD Cable
Aluminium Conductors. Polythylene or Crosslinked Polyethylene Insulation.
ABC Cables Applications:
Used to supply 3 phase power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors. 
ABC Cables Construction:
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR.One conductor is manufactured with an extruded ridge for phase identification.
ABC Cables Standards:
1.B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2.B-231 Aluminum conductors, Concentric-Lay-Stranded.
3.B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
4.B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
5.B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6.Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
ABC Cables Using Properties
1.Rated Voltage:0.6/1kV
2.Cable installation temperature not less than -20°C
3.Max. temperature of cable at short circuit(The max. duration does not exceed 5 minutes)
   For XLPE insulation is 250°C.
   For HDPE insulation is 150 °C.
4.The Max. bending radius of cable shall not be less than 20Dmm(D overall diameter of cable)
Type of ABC Cable
1.Duplex Service Drop:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75 maximum.
2.Triplex Service Drop: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation .
3.Quadruplex Service Drop: Used to supply 3 phase power , usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made . To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
ASTM B-230, B-231 and ICEA S-66-524
UL Standard 854 for type USE
Federal Specification JC-30B NEC

Code Name Phase Conductor Neutral Single Phase Conductor(in) Outside diameter(in) Weight Per 1000ft (lbls) Ampacity
Size AWG Strand Insulation Thickness (mls) Size AWG Strand Insulation Thickness (mls) Direct Burial In Duct
Tulsa 4 7/w 60 4 7/w 60 .345 .833 258 119 85
Dyke 2 7/w 60 4 7/w 60 .403 .938 346 153 115
Wittenberg 2 7/w 60 2 7/w 60 .403 .973 375 153 115
Notre Dame 1/0 19/w 80 2 7/w 60 .522 1.188 541 198 150
Purdue 1/0 19/w 80 1/0 19/w 80 .522 1.260 596 198 150
Syracuse 2/0 19/w 80 1/0 19/w 80 .566 1.316 664 225 170
Lafayette 2/0 19/w 80 2/0 19/w 80 .566 1.367 720 225 170
Swarthmore 3/0 19/w 80 1/0 19/w 80 .616 1.430 805 250 195
Davidson 3/0 19/w 80 3/0 19/w 80 .616 1.487 874 250 195
Wake Forest 4/0 19/w 80 2/0 19/w 80 .672 1.560 979 290 225
Earlham 4/0 19/w 80 4/0 19/w 80 .672 1.623 1066 290 225
Slippery Rock 350 37/w 95 4/0 19/w 80 .851 1.945 1544 385 305
Wofford 500 37/w 95 350 37/w 95 .851 2.348 2174 467 420
Windham 750 61/w 110 500 37/w 95 .979 2.850 2542 615 492

 

We are China ABC Cable XLPE Insulation HDPE Sheath/Jacket Sac Single Aluminium Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular ABC Cable Products

AAC AAAC ACSR Conductor PVC/XLPE Insulated ABC Cable

0.6/1kv Aluminum Conductor XLPE Insulated ABC Cable

0.6/1kv ABC Aluminum Conductor Aerial Bundled HDPE Power Cable.

Low Voltage 600V Triplex Service Cable 2X4AWG+4AWG

0.6/1kv Aluminum Wire XLPE Insulation ABC Wire Cable

Quadruplex 0.6/1kv XLPE Insulated Al Conductor Aerial Bundle Overhead ABC Cable

Popular HDPE Sheath/Jacket Products

10kv/33kv/35kv XLPE Insulated HDPE Sheath/Jacket Aerial Isolated Cable

Popular huatongcable Products

Copper Conductor Double XLPE Sheathed PV Cable Low Voltage 6mm

Factory Price Duplex Service Drop Cable ABC Cable 6 AWG Retriever

0.6/1kv XLPE Insulated PVC Sheathed Power Cable for Hot Sale Factory Price

UL/TUV/RoHS H01z2z2K UV Resistant -40 Degree 4mm 6mm PV Wire PV/Solar Cable

IEC 60227 Copper Conductor PVC Insulation Electric Wire BV 0.75mm2

Service Drop Cable Aerial Bundled Cable Twisted Aluminum ABC Cable

Popular Sac Products

33kV SAC Aluminum Spaced Aerial Cable TIS 2341-2555

ABC Cable Manufacturer 33kv Sac Aluminum Spaced Aerial Cable Tis 2341-2555

22kV SAC Aluminum Spaced Aerial Cable TIS 2341-2555

Aluminum conductor Aerial, size 185 sq.mm, 22kV SAC Space Aerial Cables TIS 293

Aluminum conductor Aerial, size 50 sq.mm, 33kV SAC Space Aerial Cables TIS 293

Aluminum conductor Aerial, size 185 sq.mm, 33kV SAC Space Aerial Cables TIS 293