ABC Cable XLPE Insulation HDPE Sheath/Jacket Sac Single Aluminium Cable
ABC Cable XLPE Insulation HDPE Sheath/Jacket Sac Single Aluminium Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Aluminium Conductors. Polythylene or Crosslinked Polyethylene Insulation.
ABC Cables Applications:
Used to supply 3 phase power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.
ABC Cables Construction:
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR.One conductor is manufactured with an extruded ridge for phase identification.
ABC Cables Standards:
1.B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2.B-231 Aluminum conductors, Concentric-Lay-Stranded.
3.B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
4.B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
5.B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6.Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
ABC Cables Using Properties
1.Rated Voltage:0.6/1kV
2.Cable installation temperature not less than -20°C
3.Max. temperature of cable at short circuit(The max. duration does not exceed 5 minutes)
For XLPE insulation is 250°C.
For HDPE insulation is 150 °C.
4.The Max. bending radius of cable shall not be less than 20Dmm(D overall diameter of cable)
Type of ABC Cable
1.Duplex Service Drop:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75 maximum.
2.Triplex Service Drop: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation .
3.Quadruplex Service Drop: Used to supply 3 phase power , usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made . To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
ASTM B-230, B-231 and ICEA S-66-524
UL Standard 854 for type USE
Federal Specification JC-30B NEC
| Code Name | Phase Conductor | Neutral | Single Phase Conductor(in) | Outside diameter(in) | Weight Per 1000ft (lbls) | Ampacity | |||||
| Size AWG | Strand | Insulation Thickness (mls) | Size AWG | Strand | Insulation Thickness (mls) | Direct Burial | In Duct | ||||
| Tulsa | 4 | 7/w | 60 | 4 | 7/w | 60 | .345 | .833 | 258 | 119 | 85 |
| Dyke | 2 | 7/w | 60 | 4 | 7/w | 60 | .403 | .938 | 346 | 153 | 115 |
| Wittenberg | 2 | 7/w | 60 | 2 | 7/w | 60 | .403 | .973 | 375 | 153 | 115 |
| Notre Dame | 1/0 | 19/w | 80 | 2 | 7/w | 60 | .522 | 1.188 | 541 | 198 | 150 |
| Purdue | 1/0 | 19/w | 80 | 1/0 | 19/w | 80 | .522 | 1.260 | 596 | 198 | 150 |
| Syracuse | 2/0 | 19/w | 80 | 1/0 | 19/w | 80 | .566 | 1.316 | 664 | 225 | 170 |
| Lafayette | 2/0 | 19/w | 80 | 2/0 | 19/w | 80 | .566 | 1.367 | 720 | 225 | 170 |
| Swarthmore | 3/0 | 19/w | 80 | 1/0 | 19/w | 80 | .616 | 1.430 | 805 | 250 | 195 |
| Davidson | 3/0 | 19/w | 80 | 3/0 | 19/w | 80 | .616 | 1.487 | 874 | 250 | 195 |
| Wake Forest | 4/0 | 19/w | 80 | 2/0 | 19/w | 80 | .672 | 1.560 | 979 | 290 | 225 |
| Earlham | 4/0 | 19/w | 80 | 4/0 | 19/w | 80 | .672 | 1.623 | 1066 | 290 | 225 |
| Slippery Rock | 350 | 37/w | 95 | 4/0 | 19/w | 80 | .851 | 1.945 | 1544 | 385 | 305 |
| Wofford | 500 | 37/w | 95 | 350 | 37/w | 95 | .851 | 2.348 | 2174 | 467 | 420 |
| Windham | 750 | 61/w | 110 | 500 | 37/w | 95 | .979 | 2.850 | 2542 | 615 | 492 |
We are China ABC Cable XLPE Insulation HDPE Sheath/Jacket Sac Single Aluminium Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular ABC Cable Products
Aluminium Conductor XLPE / PE Insulated ABC Power Cable
ABC Conductor Aluminum Electrical Overhead Cable with PE or XLPE Insulation
Overhead Aerial Bundle (AL/XLPE) Insulated ABC Cable-AS/NZS 3560.1 Standard
ABC Cable --Aerial Bundled Cable
Ume Brand All Size PVC/XLPE/PE Insulated Aluminum Conductor Triplex Service Drop Cable
Popular HDPE Sheath/Jacket Products
10kv/33kv/35kv XLPE Insulated HDPE Sheath/Jacket Aerial Isolated Cable
Popular huatongcable Products
Overhead Triplex Service Drop Limpet Aerial Bundled Cable for Transmission Line
ACSR AAC AAAC Overhead Conductor Low Price From Direct Factory, ACSR Aluminium Bare Conductors
Quality Factory Price Rg8 Coaxial Cable
Power Distribution Aluminium Urd Cable
0.6/1 Kv Aluminum Conductor XLPE Insulated PVC Jacket 1*120mm2 Yjlv Cable
Popular Sac Products
Aluminum conductor Aerial, size 50 sq.mm, 33kV SAC Space Aerial Cables TIS 293
Aluminum conductor Aerial, size 185 sq.mm, 33kV SAC Space Aerial Cables TIS 293
15kv Sac 240mm2 Aluminum Spaced Aerial Cable
33kV SAC Aluminum Spaced Aerial Cable TIS 2341-2555
Aluminum conductor Aerial, size 185 sq.mm, 22kV SAC Space Aerial Cables TIS 293
ABC Cable Manufacturer 33kv Sac Aluminum Spaced Aerial Cable Tis 2341-2555