ABC Triplex 2/0 AWG Cyclops Alloy Neutral Service Drop

China 
                        ABC Triplex 2/0 AWG Cyclops Alloy Neutral Service Drop
                      manufacture and supplier

ABC Triplex 2/0 AWG Cyclops Alloy Neutral Service Drop image

Get Latest Price Request a quote

Quick Details

ABC Triplex 2/0 AWG Cyclops Alloy Neutral Service Drop

ABC Cable

Huatong

Jkv

ISO, CCC, CE, UL

Aluminium

Round Wire

None

XLPE

DC & AC

Low and Medium Voltage Cable

Construction, Overhead, Industrial, Power Station

Black

PVC/PE/XLPE

40000m2

HUATONG

Drum

GB/T 12527

China

8544492100

Product Details

Aluminium Secondary UD Cable
Aluminium Conductors. Polythylene or Crosslinked Polyethylene Insulation.
ABC Cables Applications:
Used to supply 3 phase power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75° C for polyethylene insulated conductors or 90° C for crosslinked polyethylene (XLP) insulated conductors.
ABC Cables Construction:
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR. One conductor is manufactured with an extruded ridge for phase identification.
ABC Cables Standards:
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
ABC Cables Using Properties
1. Rated Voltage: 0.6/1kV
2. Cable installation temperature not less than -20° C
3. Max. Temperature of cable at short circuit(The max. Duration does not exceed 5 minutes)
For XLPE insulation is 250° C.
For HDPE insulation is 150 ° C.
4. The Max. Bending radius of cable shall not be less than 20Dmm(D overall diameter of cable)
Type of ABC Cable
1. Duplex Service Drop: To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.
2. Triplex Service Drop: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.
3. Quadruplex Service Drop: Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
ASTM B-230, B-231 and ICEA S-66-524
UL Standard 854 for type USE
Federal Specification JC-30B NEC

We are China ABC Triplex 2/0 AWG Cyclops Alloy Neutral Service Drop manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular ABC Cable Products

Aerial Bundle Cable 50mm2 70mm2 95mm2 Hot Sale

Aerial Bundle ABC Cable Service Drop Wire

Mv Aerial Bundled Conductor ABC Overhead Cables Distribution Line

XLPE Insulated Overhead Cable ABC Cable

LV/Mv Copper/Aluminum Core Aerial Bundled Cables XLPE Insulated 11kv 33kv Overhead ABC Cable

3*35+1*25 ABC Aluminum Cable Insulated Areal Bundle Cable for Yemen

Popular Alloy Neutral Products

  • No related articles
  • Popular Cyclops Products

  • No related articles
  • Popular huatongcable Products

    Concentric Neutral Cable 2*8AWG

    Low Voltage Aluminium Conductor XLPE Steel Tape Armoured Cable

    Concentric Neutral Cable 2*6wg

    Aluminum Conductors XLPE Insulation Three Phase ABC Cable

    with Ce UL Certificate 795 Mcm ACSR Drake

    Bare Conductor ACSR Cable with ASTM B 232 From China Huatong Supplier

    Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION