ABC Triplex 2/0 AWG Cyclops Alloy Neutral Service Drop
ABC Triplex 2/0 AWG Cyclops Alloy Neutral Service Drop image
Get Latest Price Request a quote
Quick Details
Product Details
Aluminium Conductors. Polythylene or Crosslinked Polyethylene Insulation.
ABC Cables Applications:
Used to supply 3 phase power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75° C for polyethylene insulated conductors or 90° C for crosslinked polyethylene (XLP) insulated conductors.
ABC Cables Construction:
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR. One conductor is manufactured with an extruded ridge for phase identification.
ABC Cables Standards:
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
ABC Cables Using Properties
1. Rated Voltage: 0.6/1kV
2. Cable installation temperature not less than -20° C
3. Max. Temperature of cable at short circuit(The max. Duration does not exceed 5 minutes)
For XLPE insulation is 250° C.
For HDPE insulation is 150 ° C.
4. The Max. Bending radius of cable shall not be less than 20Dmm(D overall diameter of cable)
Type of ABC Cable
1. Duplex Service Drop: To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.
2. Triplex Service Drop: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.
3. Quadruplex Service Drop: Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
ASTM B-230, B-231 and ICEA S-66-524
UL Standard 854 for type USE
Federal Specification JC-30B NEC
We are China ABC Triplex 2/0 AWG Cyclops Alloy Neutral Service Drop manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular ABC Cable Products
Aerial Bundle Cable 50mm2 70mm2 95mm2 Hot Sale
Aerial Bundle ABC Cable Service Drop Wire
Mv Aerial Bundled Conductor ABC Overhead Cables Distribution Line
XLPE Insulated Overhead Cable ABC Cable
LV/Mv Copper/Aluminum Core Aerial Bundled Cables XLPE Insulated 11kv 33kv Overhead ABC Cable
3*35+1*25 ABC Aluminum Cable Insulated Areal Bundle Cable for Yemen
Popular Alloy Neutral Products
Popular Cyclops Products
Popular huatongcable Products
Concentric Neutral Cable 2*8AWG
Low Voltage Aluminium Conductor XLPE Steel Tape Armoured Cable
Concentric Neutral Cable 2*6wg
Aluminum Conductors XLPE Insulation Three Phase ABC Cable
with Ce UL Certificate 795 Mcm ACSR Drake
Bare Conductor ACSR Cable with ASTM B 232 From China Huatong Supplier
Tags: ABC Cable, Alloy Neutral, Cyclops, huatongcable