Simple structure / Easy installation and maintenance / Low circuit cost / Large transmission capacity / Good conductive performance / Sufficient mechanical strength / High tensile strength
ACSR Cable Advantage:
1. Convenient for laying across special geographical conditions such as rivers and valleys
2.The tower distance can be enlarged
ACSR Cable Application:
Widely used in overhead power transmission lines of various voltage levels
AAAC Cable Applications
AAAC Aluminum Alloy Conductor is Used as bare overhead conductor for primary and secondary distribution. Designed utilizing a high-strength aluminum alloy to achieve a high strength-to-weight ratio; affords better sag characteristics. Aluminum alloy gives higher resistance to corrosion than ACSR.
Standard
BS EN50183,IEC 61089, ASTM B399,BS 3242, DIN 48204,GB/T1179-2008
Specification
Physical contents of aluminum alloy :-
1. Resistivity – 0.0326 Ohms mm2/m at 20°C
2. Density – 2.70 kgm/dm3 at 20°C
3. Coefficient of Linear Expansion – 23 x 10-6 / °C
4. Constant Mass Temperature Coefficient (a) – 0.00360/ °C
5. Material – Heat treated Al. Mg. Si. Alloy
– Approximately 0.5% Mg & 0.5% Si
ASTM B399
Code Name | Area | Size & Stranding of ACSR with Equal Diameter | No. & Diameter of wires | Overall Diameter | Weight | Nominal Breaking Load | ||
Nominal | Actual | |||||||
MCM | mm2 | AWG or MCM | Al/Steel | mm | mm | kg/km | kN | |
Akron | 30.58 | 15.48 | 6 | 6/1 | 7/1.68 | 5.04 | 42.7 | 4.92 |
Alton | 48.69 | 24.71 | 4 | 6/1 | 7/2.12 | 6.35 | 68.0 | 7.84 |
Ames | 77.47 | 39.22 | 2 | 6/1 | 7/2.67 | 8.02 | 108 | 12.45 |
Azusa | 123.3 | 62.38 | 1/0 | 6/1 | 7/3.37 | 10.11 | 172 | 18.97 |
Anaheim | 155.4 | 78.65 | 2/0 | 6/1 | 7/3.78 | 11.35 | 217 | 23.93 |
Amherst | 195.7 | 99.22 | 3/0 | 6/1 | 7/4.25 | 12.75 | 273 | 30.18 |
Alliance | 246.9 | 125.1 | 4/0 | 6/1 | 7/4.77 | 14.31 | 345 | 38.05 |
Butte | 312.8 | 158.6 | 266.8 | 26/7 | 19/3.26 | 16.30 | 437 | 48.76 |
Canton | 394.5 | 199.9 | 336.4 | 26/7 | 19/3.66 | 18.30 | 551 | 58.91 |
Cairo | 465.4 | 235.8 | 397.5 | 26/7 | 19/3.98 | 19.88 | 650 | 69.48 |
Darien | 559.5 | 283.5 | 477.0 | 26/7 | 19/4.36 | 21.79 | 781 | 83.52 |
Elgin | 652.4 | 330.6 | 556.5 | 26/7 | 19/4.71 | 23.54 | 911 | 97.42 |
Flint | 740.8 | 375.3 | 636.0 | 26/7 | 37/3.59 | 25.16 | 1035 | 108.21 |
Greely | 927.2 | 469.8 | 795.0 | 26/7 | 37/4.02 | 28.14 | 1295 | 135.47 |
IEC 61089
Code Number | A2 Conductor | A3 Conductor | Max.D.C. Resistance of Conductor at 20ºC | ||||||||
Number of Wires | Diameter of Wires | Diameter of Conductor | Approx. Weight | Rated Strength | Number of Wires | Diameter of Wires | Diameter of Conductor | Approx. Weight | Rated Strength | ||
mm² | – | mm | mm | kg/km | daN | – | mm | mm | kg/km | daN | Ω/km |
16 | 7 | 1.83 | 5.49 | 50.4 | 5.43 | 7 | 1.84 | 5.52 | 50.8 | 6.04 | 1.7896 |
25 | 7 | 2.29 | 6.87 | 78.7 | 8.49 | 7 | 2.30 | 6.9 | 79.5 | 9.44 | 1.1453 |
40 | 7 | 2.89 | 8.67 | 125.9 | 13.58 | 7 | 2.91 | 8.73 | 127.1 | 15.1 | 0.7158 |
63 | 7 | 3.63 | 10.8 | 198.3 | 21.39 | 7 | 3.65 | 10.95 | 200.2 | 23.06 | 0.4545 |
100 | 19 | 2.78 | 13.9 | 316.3 | 33.95 | 19 | 2.79 | 13.95 | 319.3 | 37.76 | 0.2877 |
125 | 19 | 3.10 | 15.5 | 395.4 | 42.44 | 19 | 3.12 | 15.6 | 399.2 | 47.20 | 0.2302 |
160 | 19 | 3.51 | 17.55 | 506.1 | 54.32 | 19 | 3.53 | 17.65 | 511.0 | 58.56 | 0.1798 |
200 | 19 | 3.93 | 19.65 | 623.7 | 67.91 | 19 | 3.95 | 19.75 | 638.7 | 73.20 | 0.1439 |
250 | 19 | 4.39 | 21.95 | 790.8 | 84.68 | 19 | 4.41 | 22.05 | 798.4 | 91.50 | 0.1151 |
315 | 37 | 3.53 | 24.71 | 998.9 | 106.95 | 37 | 3.55 | 24.85 | 1008.4 | 115.29 | 0.0916 |
400 | 37 | 3.98 | 27.86 | 1268.4 | 135.81 | 37 | 4.0 | 28 | 1280.5 | 146.4o | 0.0721 |
450 | 37 | 4.22 | 29.54 | 1426.9 | 152.79 | 37 | 4.24 | 29.68 | 1440.5 | 164.70 | 0.0641 |
500 | 37 | 4.45 | 31.15 | 1585.5 | 169.76 | 37 | 4.47 | 31.29 | 1600.6 | 183.oo | 0.0577 |
560 | 61 | 3.67 | 33.03 | 1778.4 | 190.14 | 61 | 3.69 | 33.21 | 1795.3 | 204.95 | 0.0516 |
630 | 61 | 3.89 | 35.01 | 2000.7 | 213.90 | 61 | 3.91 | 35.19 | 2019.8 | 230.58 | 0.0458 |
710 | 61 | 4.13 | 37.17 | 2254.8 | 241.07 | 61 | 4.15 | 37.35 | 2276.2 | 259.86 | 0.0407 |
800 | 61 | 4.38 | 39.42 | 2540.6 | 271.62 | 61 | 4.4 | 39.6 | 2564.8 | 282.80 | 0.0361 |
900 | 91 | 3.81 | 41.91 | 2861.1 | 305.58 | 91 | 3.83 | 42.13 | 2888.3 | 329.40 | 0.0321 |
1000 | 91 | 4.01 | 44.11 | 3179.0 | 339.53 | 91 | 4.03 | 44.33 | 3209.3 | 366.00 | 0.0289 |
1120 | 91 | 4.25 | 46.75 | 3560.5 | 380.27 | 91 | 4.27 | 46.97 | 3594.4 | 409.92 | 0 0258 |
1250 | 91 | 4.49 | 49.39 | 3973.7 | 424.41 | – | – | – | – |
BS EN50183
Code Name | Calculated Cross Section |
No..Dia.of Wires | Overall Diameter | Weight | Rated Strength |
mm² | No./mm | mm | kg/km | kN | |
Box | 18.8 | 7/1.85 | 5.55 | 51.4 | 5.55 |
Acacia | 23.8 | 7/2.08 | 6.24 | 64.9 | 7.02 |
Almond | 30.1 | 7/2.34 | 7.02 | 82.2 | 8.88 |
Cedar | 35.5 | 7/2.54 | 7.62 | 96.8 | 10.46 |
Deodar | 42.2 | 7/2.77 | 8.31 | 115.2 | 12.44 |
Fir | 47.8 | 7/2.95 | 8.85 | 130.6 | 14.11 |
Hazel | 59.9 | 7/3.30 | 9.90 | 163.4 | 17.66 |
Pine | 71.6 | 7/3.61 | 10.8 | 195.6 | 21.14 |
Holly | 84.1 | 7/3.91 | 11.7 | 229.5 | 24.79 |
Willow | 89.7 | 7/4.04 | 12.1 | 245,0 | 26.47 |
Oak | 118.9 | 7/4.65 | 14.0 | 324.5 | 35.07 |
Mulberry | 150.9 | 19/3.18 | 15.9 | 414.3 | 44.52 |
Ash | 180.7 | 19/3.48 | 17.4 | 496.1 | 53.31 |
Elm | 211.0 | 19/3.76 | 18.8 | 579.2 | 62.24 |
Poplar | 239.4 | 37/2.87 | 20.1 | 659.4 | 70.61 |
Sycamore | 303.2 | 37/3.23 | 22.6 | 835.2 | 89.40 |
Upas | 362.1 | 37/3.53 | 24.7 | 997.5 | 106.82 |
Yew | 479.0 | 37/4.06 | 28.4 | 1319.6 | 141.31 |
Totara | 498.1 | 37/4.14 | 29.0 | 1372.1 | 146.93 |
Rubus | 586.9 | 61/3.50 | 31.5 | 1622.0 | 173.13 |
Sorbus | 659.4 | 61/3.71 | 33.4 | 1822.5 | 194.53 |
Araucaria | 821.1 | 61/4.14 | 37.3 | 2269.4 | 242.24 |
Redwood | 996.2 | 61/4.56 | 41.0 | 2753.2 | 293.88 |
Din 48201
Code number | Calculated area | Number of wires | Diameter of wire | Overall diameter of conductor | Linear mass | Rated tensile strength | Max. DC resistance at 20ºC |
mm2 | mm2 | mm | mm | kg/km | daN | Ω/km | |
16 | 15.89 | 7 | 1.70 | 5.1 | 43 | 444 | 2.0910 |
25 | 24.25 | 7 | 2.10 | 6.3 | 66 | 677 | 1.3703 |
35 | 34.36 | 7 | 2.50 | 7.5 | 94 | 960 | 0.9669 |
50 | 49.48 | 7 | 3.00 | 9.0 | 135 | 1382 | 0.6714 |
50 | 48.35 | 19 | 1.80 | 9.0 | 133 | 1350 | 0.6905 |
70 | 65.81 | 19 | 2.10 | 10.5 | 181 | 1838 | 0.5073 |
95 | 93.27 | 19 | 2.50 | 12.5 | 256 | 2605 | 0.3579 |
120 | 116.99 | 19 | 2.80 | 14.0 | 322 | 3268 | 0.2854 |
150 | 147.11 | 37 | 2.25 | 15.8 | 406 | 4109 | 0.2274 |
185 | 181.62 | 37 | 2.50 | 17.5 | 500 | 5073 | 0.1842 |
240 | 242.54 | 61 | 2.25 | 20.3 | 670 | 6774 | 0.1383 |
300 | 299.43 | 61 | 2.50 | 22.5 | 827 | 8363 | 0.1120 |
400 | 400.14 | 61 | 2.89 | 26.0 | 1104 | 11176 | 0.0838 |
500 | 499.63 | 61 | 3.23 | 29.1 | 1379 | 13960 | 0.06709 |
625 | 626.20 | 91 | 2.96 | 32.6 | 1732 | 17490 | 0.0540 |
800 | 802.09 | 91 | 3.35 | 36.9 | 2218 | 22402 | 0.0418 |
1000 | 999.71 | 91 | 3.74 | 41.1 | 2767 | 27922 | 0.0335 |
We are China ACSR Aluminum Conductor Steel Reinforced manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular ACSR Products
AAC AAAC ACSR Bare Conductor for Sale
ACSR Overhead Bare Conductor Electrical Wire Cable
Professional Steel Reinforced Aluminium Conductor 100mm2
ASTM B232 Standard Aluminium Conductor Steel Reinforced ACSR Cable Wire
Aluminum Conductor ABC Power XLPE Insulated PVC Douplex Triple Overhead Aerial Bundle Cable
ACSR Wood Duck Conductor Transmission Line
Popular Bare Conductor Products
ASTM B231 AAC Marigold Conductor Aluminum Overhead Conductor
BS 215 100mm2 Overhead ACSR Dog/Hare/Hyena Conductor Bare Conductor
0.6/1kv Stranded AAC Aluminum Conductor Electrical Power Cable
High Voltage Overhead Cable ACSR Steel Wire Reinforced Cable Code Wren ASTM Standard
477 Mcm Cosmos AAC Bare Aluminum Conductor Asrmb231, 230
Overhead Transmission Factory Supply Bare AAAC Conductor AAAC Cable
Popular Tacsr Products
Bare ACSR/Aacsr/Tacsr Conductor
Bare Conductors ACSR, AAAC, Tacsr Cable AAC Conductor
ASTM B399 6201 Overhead Electrical Cable Bare Aluminium Alloy AAC AAAC ACSR Conductor with Grease
Tacsr Power Conductor Thermal Resistant Aluminum Alloy Conductors Steel Reinforced
ACSR, Aluminium Conductors Steel Reinforced ASTM B 232
Tacsr Thermal Resistant Conductor
Popular wuhancable Products
Electrical PVC Copper Electric Flexible Rubber XLPE Insulated Control Cable
Flame Retardant XLPE Insulated Steel Tape Armoured Power Cable
450/750V Plastic Insulation Control Cable
Cost-Effective ACSR Overhead Conductor
Overhead Aluminium Cable Steel Reinforced ACSR Overhead Conductor
Copper Conductor XLPE Insulated PVC Sheath Steel Armoured Power Cable
Tags: ACSR, Bare Conductor, Tacsr, wuhancable