Acss/Tw Bare Conductor
Acss/Tw Bare Conductor image
Get Latest Price Request a quote
Quick Details
Product Details
—–BARE OVERHEAD TRAPEZOIDAL ALUMINUM CONDUCTOR STEEL-SUPPORTED, CONCENTRIC-LAY-STRANDED
(1)Production capacity:2000 ton/month
(2)MOQ:1km
(3)Delivery:5~15 officail days.
(4)Standards:IEC,ASTM,DIN,BS; or according to customers’ requirements.
(5)Delivery length:as per customers’ request.
1.Construction
ACSS/TW, a nonhomogeneous conductor, is a trapezoidal shaped wire compact concentriclay- stranded conductor made from aluminum 1350-O wires and round, coated steel core wire(s). ACSS/TW conductors withequal area or equal diameter as compared to ACSS conductors are available for overhead lines. Steel wires are coated with Class A coating of zinc – 5% aluminum mischmetal alloy. Other Classes of coatings are also available for additional protection from corrosion. Standard, High, Extra and Ultra High Strength steel are also available.
2.Features
ACSS conductors are preferred over ACSR conductors for specific transmission line
applications:
With zinc – 5% aluminum mischmetal alloy coating on steel wires, ACSS conductors can be operated
up to 250 °C.
ACSS conductors carry more current than ACSR conductors due to:
— Minimum average conductivity of 63% IACS for 1350-O aluminum wires vs. an average conductivity of 61.2% for 1350-H19 aluminum wires in ACSR.
— ACSS conductors can be operated up to 250 °C vs. the maximum operating temperature for an ACSR conductor does not exceed 100 °C.
ACSS conductors are prone to resist the effects of aeolian vibration due to very little or no mechanical load on the annealed aluminum wires.
Long term creep is not a factor when designing with ACSS conductors. In addition, use of ACSS/TW with the equal area design allows equal ampacity in a conductor with approximately 10% smaller diameter over a standard ACSS with same area. This smaller diameter of equal area ACSS/TW conductors helps reduce the effects of ice and wind loading on the conductor.
Alternatively, use of ACSS/TW with equal diameter design provides a conductor in which the aluminum area is increased by approximately 20% – 25% over a standard ACSS with same diameter. This increase
in the cross-sectional area of the conductor reduces its ac resistance by about 15% – 20% and thus, increases its current carrying capacity by about 10%.
Mob:18638549762
3.Your best choice → Huatong Cable Inc.
(1),More than 30 years experience.
(2) ,100,000m² factory,200 staffs,annual output 100,000 metic tons.
(3),Sound Quality Control
–Material inspection;
–manufacturing inspection;
— Finished products inspection;
— Inspection before delivery.
–Third party inspection.
— Inspection of storage at port of departure.
(4)ISO Certificated.
(5) Plenty of material and lobor gurantee the delivery prompt and price competitive.
(6),24/7 service.
4.Bare Conductor Types
(1) all aluminum conductor (AAC)
(2) all aluminum alloy conductor(AAAC)
(3) aluminum conductor steel reinforced (ACSR)
(4) anti-corrosion type ACSR
(5) aluminum conductor aluminum clad steel reinforced(ACSR/AW)
(6) rear earth aluminum conductor steel reinforced(ACSR/RE)
(7) aluminum conductor aluminum alloy reinforced(ACAR)
(8) aluminium conductors steel supported (ACSS)
5.Standard reference.
| Code | Size | Type | Stranding | Nominal Overall Diameter | Cross Section | |||||
| Aluminum | Steel | |||||||||
| AWG or kcmil | No. Al Wires | No. Al Layers | No. of Wires | Diameter | CDR | Steel Core | Al | Total | ||
| in | in | in2 | ||||||||
| Flicker/ACSS/TW | 477.0 | 13 | 18 | 2 | 7 | 0.0940 | 0.78 | 0.2820 | 0.3748 | 0.4234 |
| Hawk/ACSS/TW | 477.0 | 16 | 18 | 2 | 7 | 0.1053 | 0.79 | 0.3159 | 0.3745 | 0.4355 |
| Parakeet/ACSS/TW | 556.5 | 13 | 18 | 2 | 7 | 0.1015 | 0.84 | 0.3045 | 0.4372 | 0.4938 |
| Dove/ACSS/TW | 556.5 | 16 | 20 | 2 | 7 | 0.1138 | 0.85 | 0.3414 | 0.4371 | 0.5083 |
| Rook/ACSS/TW | 636.0 | 13 | 18 | 2 | 7 | 0.1085 | 0.89 | 0.3255 | 0.4994 | 0.5641 |
| Grosbeak/ACSS/TW | 636.0 | 16 | 20 | 2 | 7 | 0.1216 | 0.91 | 0.3648 | 0.4996 | 0.5809 |
| Tern/ACSS/TW | 795.0 | 7 | 17 | 2 | 7 | 0.0888 | 0.96 | 0.2664 | 0.6247 | 0.6680 |
| Puffin/ACSS/TW | 795.0 | 11 | 21 | 2 | 7 | 0.1108 | 0.98 | 0.3324 | 0.6241 | 0.6916 |
| Condor/ACSS/TW | 795.0 | 13 | 21 | 2 | 7 | 0.1213 | 0.99 | 0.3639 | 0.6242 | 0.7051 |
| Drake/ACSS/TW | 795.0 | 16 | 20 | 2 | 7 | 0.1360 | 1.01 | 0.4080 | 0.6242 | 0.7259 |
| Phoenix/ACSS/TW | 954.0 | 5 | 30 | 3 | 7 | 0.0837 | 1.04 | 0.2511 | 0.7497 | 0.7882 |
| Rail/ACSS/TW | 954.0 | 7 | 32 | 3 | 7 | 0.0971 | 1.06 | 0.2913 | 0.7493 | 0.8011 |
| Cardinal/ACSS/TW | 954.0 | 13 | 21 | 2 | 7 | 0.1329 | 1.08 | 0.3987 | 0.7492 | 0.8463 |
| Snowbird/ACSS/TW | 1033.5 | 5 | 30 | 3 | 7 | 0.0871 | 1.09 | 0.2613 | 0.8115 | 0.8532 |
| Ortolan/ACSS/TW | 1033.5 | 7 | 33 | 3 | 7 | 0.1010 | 1.10 | 0.3030 | 0.8112 | 0.8673 |
| Curlew/ACSS/TW | 1033.5 | 13 | 21 | 2 | 7 | 0.1383 | 1.13 | 0.4149 | 0.8118 | 0.9170 |
| Avocet/ACSS/TW | 1113.0 | 5 | 30 | 3 | 7 | 0.0904 | 1.13 | 0.2712 | 0.8737 | 0.9186 |
| Bluejay/ACSS/TW | 1113.0 | 7 | 33 | 3 | 7 | 0.1049 | 1.14 | 0.3147 | 0.8746 | 0.9351 |
| Finch/ACSS/TW | 1113.0 | 13 | 39 | 3 | 19 | 0.0862 | 1.18 | 0.4310 | 0.8737 | 0.9845 |
| Oxbird/ACSS/TW | 1192.5 | 5 | 30 | 3 | 7 | 0.0936 | 1.17 | 0.2808 | 0.9361 | 0.9843 |
| Bunting/ACSS/TW | 1192.5 | 7 | 33 | 3 | 7 | 0.1086 | 1.18 | 0.3258 | 0.9368 | 1.0016 |
| Grackle/ACSS/TW | 1192.5 | 13 | 39 | 3 | 19 | 0.0892 | 1.22 | 0.4460 | 0.9369 | 1.0556 |
| Scissortail/ACSS/TW | 1272.0 | 5 | 30 | 3 | 7 | 0.0967 | 1.20 | 0.2901 | 0.9994 | 1.0508 |
| Bittern/ACSS/TW | 1272.0 | 7 | 33 | 3 | 7 | 0.1121 | 1.22 | 0.3363 | 0.9994 | 1.0685 |
| Pheasant/ACSS/TW | 1272.0 | 13 | 39 | 3 | 19 | 0.0921 | 1.26 | 0.4605 | 0.9987 | 1.1252 |
| Dipper/ACSS/TW | 1351.5 | 7 | 33 | 3 | 7 | 0.1155 | 1.25 | 0.3465 | 1.0616 | 1.1350 |
| Martin/ACSS/TW | 1351.5 | 13 | 39 | 3 | 19 | 0.0949 | 1.30 | 0.4745 | 1.0610 | 1.1954 |
| Bobolink/ACSS/TW | 1431.0 | 7 | 33 | 3 | 7 | 0.1189 | 1.29 | 0.3567 | 1.1243 | 1.2020 |
| Plover/ACSS/TW | 1431.0 | 13 | 39 | 3 | 19 | 0.0977 | 1.33 | 0.4885 | 1.1242 | 1.2666 |
| Lapwing/ACSS/TW | 1590.0 | 7 | 36 | 3 | 7 | 0.1253 | 1.36 | 0.3759 | 1.2488 | 1.3351 |
| Falcon/ACSS/TW | 1590.0 | 13 | 39 | 3 | 19 | 0.1030 | 1.40 | 0.5150 | 1.2483 | 1.4066 |
| Chukar/ACSS/TW | 1780.0 | 8 | 38 | 3 | 19 | 0.0874 | 1.45 | 0.4370 | 1.3982 | 1.5122 |
| Bluebird/ACSS/TW* | 2156.0 | 8 | 64 | 4 | 19 | 0.0961 | 1.61 | 0.4805 | 1.6934 | 1.8312 |
| Mohawk/ACSS/TW | 571.7 | 13 | 18 | 2 | 7 | 0.103 | 0.846 | 0.309 | 0.4489 | 0.5072 |
| Calumet/ACSS/TW | 565.3 | 16 | 20 | 2 | 7 | 0.1146 | 0.858 | 0.3438 | 0.4438 | 0.5161 |
| Mystic/ACSS/TW | 666.6 | 13 | 20 | 2 | 7 | 0.1111 | 0.913 | 0.3333 | 0.5236 | 0.5915 |
| Oswego/ACSS/TW | 664.8 | 16 | 20 | 2 | 7 | 0.1244 | 0.927 | 0.3732 | 0.5222 | 0.6073 |
| Maumee/ACSS/TW | 768.2 | 13 | 20 | 2 | 7 | 0.1195 | 0.977 | 0.3585 | 0.6032 | 0.6817 |
| Wabash/ACSS/TW | 762.8 | 16 | 20 | 2 | 7 | 0.1331 | 0.99 | 0.3993 | 0.5989 | 0.6963 |
| Kettle/ACSS/TW | 957.2 | 7 | 32 | 3 | 7 | 0.0973 | 1.06 | 0.2919 | 0.7518 | 0.8038 |
| Suwannee/ACSS/TW | 959.6 | 16 | 22 | 2 | 7 | 0.1493 | 1.108 | 0.4479 | 0.7539 | 0.8764 |
| Cheyenne/ACSS/TW | 1168.1 | 5 | 30 | 3 | 7 | 0.0926 | 1.155 | 0.2778 | 0.917 | 0.9642 |
| Genesee/ACSS/TW | 1158.0 | 7 | 33 | 3 | 7 | 0.1078 | 1.165 | 0.3234 | 0.9094 | 0.9732 |
| Hudson/ACSS/TW | 1158.4 | 13 | 26 | 2 | 7 | 0.1467 | 1.196 | 0.4401 | 0.9096 | 1.0279 |
| Catawba/ACSS/TW | 1272.0 | 5 | 30 | 3 | 7 | 0.0967 | 1.203 | 0.2901 | 0.9993 | 1.0507 |
| Nelson/ACSS/TW | 1257.1 | 7 | 35 | 3 | 7 | 0.1115 | 1.213 | 0.3345 | 0.9875 | 1.0558 |
| Yukon/ACSS/TW | 1233.6 | 13 | 38 | 3 | 19 | 0.091 | 1.25 | 0.455 | 0.9685 | 1.0921 |
| Truckee/ACSS/TW | 1372.5 | 5 | 30 | 3 | 7 | 0.1004 | 1.248 | 0.3012 | 1.0783 | 1.1337 |
| Mackenzie/ACSS/TW | 1359.7 | 7 | 36 | 3 | 7 | 0.1159 | 1.259 | 0.3477 | 1.0674 | 1.1413 |
| Thames/ACSS/TW | 1334.6 | 13 | 39 | 3 | 19 | 0.0944 | 1.29 | 0.472 | 1.0479 | 1.1808 |
| St.Croix/ACSS/TW | 1467.8 | 5 | 30 | 3 | 7 | 0.1041 | 1.292 | 0.3123 | 1.1532 | 1.2127 |
| Miramichi/ACSS/TW | 1455.3 | 7 | 36 | 3 | 7 | 0.12 | 1.299 | 0.36 | 1.1427 | 1.2219 |
| Merrimack/ACSS/TW | 1433.6 | 13 | 39 | 3 | 19 | 0.0978 | 1.34 | 0.489 | 1.1255 | 1.2682 |
| Platte/ACSS/TW | 1569.0 | 5 | 33 | 3 | 7 | 0.1074 | 1.334 | 0.3222 | 1.2328 | 1.2962 |
| Potomac/ACSS/TW | 1557.4 | 7 | 36 | 3 | 7 | 0.1241 | 1.345 | 0.3723 | 1.2237 | 1.3084 |
| Rio Grande/ACSS/TW | 1533.3 | 13 | 39 | 3 | 19 | 0.1012 | 1.379 | 0.506 | 1.2046 | 1.3574 |
| Schuylkill/ACSS/TW | 1657.4 | 7 | 36 | 3 | 7 | 0.128 | 1.386 | 0.384 | 1.3012 | 1.3912 |
| Pecos/ACSS/TW | 1622.0 | 13 | 39 | 3 | 19 | 0.1064 | 1.424 | 0.532 | 1.2736 | 1.4425 |
| Pee Dee/ACSS/TW | 1758.6 | 7 | 37 | 3 | 7 | 0.1319 | 1.431 | 0.3957 | 1.3811 | 1.4768 |
| James/ACSS/TW | 1730.6 | 13 | 39 | 3 | 19 | 0.1075 | 1.47 | 0.5375 | 1.3598 | 1.5322 |
| Athabaska/ACSS/TW | 1949.6 | 7 | 42 | 3 | 7 | 0.1392 | 1.504 | 0.4176 | 1.5318 | 1.6384 |
| Cumberland/ACSS/TW | 1926.9 | 13 | 42 | 3 | 19 | 0.1133 | 1.545 | 0.5665 | 1.5129 | 1.7044 |
| Santee/ACSS/TW | 2627.3 | 8 | 64 | 4 | 19 | 0.1062 | 1.762 | 0.531 | 2.0645 | 2.2328 |
We are China Acss/Tw Bare Conductor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular ACSR Products
AAAC 120mm Standards Aluminum Alloy Conductor Steel Reinforced Overhead Electric Powe Wire
ACSR Hawk Aluminum Conductor Steel Reinforced Bare Aluminum Conductor
ACSR490/65 Product Aluminum Stranded Conductors Steel Reinforced
Aluminum Grease for ACSR Conductor Standard ASTM B232, DIN 48204, BS 215
Type ACSR/GZ MANGO All Aluminum Conductor Steel Reinforced AS 3607
Popular Bare Conductor Products
Overhead Transmission Line Bare Conductor 1350aluminum 6201aluminum Alloy Stranded Acar
7/2.47 Iris 33mm2 All Aluminum Conductor AAC Overhead Bare Aluminum Conductor Wires
Transmission Line All Aluminium Stranded Conductor AAC Cobductor
Overhead Cable All Aluminum AAC ACSR AAAC Conductor
Aacsr, Aluminium Alloy Conductors Steel Reinforced Bare Conductor
AAC 7, 19, 37 Stranding Aluminum Wires Power Distribution Bare Conductor Cable
Popular huatongcable Products
Flexible Flat Copper Cable with Earth Wire Cable
IEC 60502-2 Single Core XLPE Insualted Armour 19/33kv Aluminum Cable
ASTM Standard Stay Wire, Guy Wire Stranded Galvanized Steel Wire 5/16
6201 Aluminum Alloy Conductor AAAC for State Grid Power Project
Yjlv22/Yjlv32/Yjlv42, Power Cable Yjv22/Yjv32 Power Cable
Popular Overhead Conductor Products
All Aluminium Conductor, AAC BS 215: 1970
High Quality Covered Line Wire with ASTM Standard Overhead Conductor PE/XLPE Insulated Cable
Aluminum Alloy Conductor Steel Reinforced Aacsr Conductor
ASTM B231 Overhead Bare Stranded All Aluminum AAC Sagebrusch Conductor
ASTM B231 Overhead Bare Stranded All Aluminum AAC Lupine Conductor
2017 Hot Sale Overhead Bare Aluminum AAC AAAC Conductor
Tags: ACSR, Bare Conductor, huatongcable, Overhead Conductor