Aerial Bundled Cable-0.6/1kv Overhead Cable ABC Cable
Aerial Bundled Cable-0.6/1kv Overhead Cable ABC Cable image
Get Latest Price Request a quote
Quick Details
Product Details
1.Application
Used as overhead cable to supply power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.
2.Standard:
ASTM B-230 – Aluminum 1350-H19 Wire for Electrical Purposes
ASTM B-231 – Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR).
ASTM B-1248 – Polyethylene Plastics Molding and Extrusion Materials.
ASTM C-8.35 – Specifications for Weather-Resistant Polyethylene-Covered Wire and Cable.
ICEAS-61-402
3.Specification
Triplex service drop cable meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
B-231 Aluminum Conductors, Concentric-Lay-Stranded.
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced(ACSR).
B-399 Stranded 6201-T81 Aluminum Alloy Conductors.
B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire.
triplex service drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
Aluminum conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or cross-linked polyethylene (XLPE).
Neutral messengers are concentrically stranded 6201, AAC, or ACSR.
| Triplex service drop | ||||||||||
| Code Name | Phase conductor | Bare Neutral Message | Nominal Weight ( kg/km ) | Allowable Ampacity | ||||||
| Size & No.of wires | Insulation Thick(mm) | Nominal Diameter (mm) | Size & No.of wires | Rated Strength (kg) | XLPE | Aluminum | Total | ( A ) | ||
| Bare | OD | |||||||||
| AAAC | ||||||||||
| Homarus | 6-Solid | 1.14 | 4.115 | 6.4 | 6-7 | 499 | 42 | 118 | 159 | 78 |
| Minex | 6-Solid | 1.14 | 4.115 | 13.3 | 6-7 | 499 | 42 | 118 | 159 | 78 |
| Cabera | 6-7 | 1.14 | 4.65 | 6.9 | 6-7 | 499 | 48 | 118 | 165 | 78 |
| Hippa | 6-7 | 1.14 | 4.65 | 6.9 | 6-7 | 499 | 48 | 118 | 165 | 78 |
| Artemia | 4-Solid | 1.14 | 5.182 | 7.5 | 6-7 | 499 | 52 | 162 | 214 | 103 |
| Maria | 4-7 | 1.14 | 5.89 | 8.2 | 6-7 | 499 | 60 | 188 | 247 | 103 |
| Crab | 4-7 | 1.14 | 5.89 | 8.2 | 6-7 | 499 | 60 | 162 | 222 | 103 |
| Ludia | 4-Solid | 1.14 | 5.182 | 7.5 | 6-7 | 499 | 52 | 162 | 214 | 103 |
| Prawn | 4-Solid | 1.14 | 5.182 | 7.5 | 4-7 | 798 | 52 | 188 | 240 | 103 |
| Metalia | 4-7 | 1.14 | 5.89 | 8.2 | 4-7 | 798 | 60 | 188 | 247 | 103 |
| Bamacles | 4-7 | 1.14 | 5.89 | 8.2 | 4-7 | 798 | 60 | 188 | 247 | 103 |
| Solaster | 2-7 | 1.14 | 7.42 | 9.7 | 4-7 | 798 | 76 | 258 | 333 | 136 |
| Pagarus | 2-7 | 1.52 | 7.42 | 10.5 | 4-7 | 798 | 100 | 258 | 357 | 136 |
| Shrimp | 2-7 | 1.14 | 7.42 | 9.7 | 2-7 | 1270 | 76 | 298 | 374 | 136 |
| Lobster | 2-7 | 1.52 | 7.42 | 10.5 | 2-7 | 1270 | 100 | 298 | 397 | 136 |
| Encope | 1-19 | 1.52 | 8.43 | 11.5 | 2-7 | 1270 | 115 | 347 | 461 | 158 |
| Sanderab | 1/0-7 | 1.52 | 9.35 | 12.4 | 2-7 | 1270 | 128 | 409 | 537 | 182 |
| Echinus | 1/0-19 | 1.52 | 9.47 | 12.5 | 2-7 | 1270 | 130 | 409 | 539 | 182 |
| Gammarus | 1/0-7 | 1.52 | 9.35 | 12.4 | 1/0-7 | 2023 | 128 | 473 | 601 | 182 |
| Leda | 1/0-19 | 1.52 | 9.47 | 12.5 | 1/0-7 | 2023 | 130 | 473 | 603 | 182 |
| Crayfish | 2/0-7 | 1.52 | 10.5 | 13.6 | 2-7 | 1270 | 146 | 487 | 631 | 210 |
| Sipho | 2/0-19 | 1.52 | 10.6 | 13.7 | 2-7 | 1270 | 147 | 487 | 634 | 210 |
| Dungenese | 2/0-7 | 1.52 | 10.5 | 13.6 | 2/0-7 | 2445 | 146 | 595 | 740 | 210 |
| Cyclops | 2/0-7 | 1.52 | 10.6 | 13.7 | 2/0-7 | 2445 | 147 | 595 | 743 | 210 |
| Slug | 3/0-7 | 1.52 | 11.8 | 14.8 | 1/0-7 | 2023 | 165 | 650 | 816 | 242 |
| Fulgur | 3/0-19 | 1.52 | 11.9 | 15.0 | 1/0-7 | 2023 | 168 | 650 | 819 | 242 |
| Balanus | 3/0-19 | 2.03 | 11.9 | 16.0 | 1/0-7 | 2023 | 216 | 650 | 868 | 242 |
| Stonecrab | 3/0-7 | 1.52 | 11.8 | 14.8 | 3/0-7 | 3080 | 165 | 752 | 917 | 242 |
| Flustra | 3/0-7 | 1.52 | 11.9 | 15.0 | 3/0-7 | 3080 | 168 | 752 | 920 | 242 |
| Crisia | 3/0-19 | 2.03 | 11.9 | 16.0 | 3/0-7 | 3080 | 216 | 752 | 969 | 242 |
| Squid | 4/0-7 | 1.52 | 13.3 | 16.3 | 2/0-7 | 2431 | 191 | 820 | 1011 | 279 |
| Area | 4/0-19 | 1.52 | 13.4 | 16.5 | 2/0-7 | 2431 | 192 | 820 | 1012 | 279 |
| Bugula | 4/0-19 | 2.03 | 13.4 | 17.5 | 2/0-7 | 2431 | 246 | 820 | 1066 | 279 |
| Kingerab | 4/0-7 | 1.52 | 13.3 | 16.3 | 4/0-7 | 3883 | 191 | 948 | 1137 | 279 |
| Lepas | 4/0-19 | 1.52 | 13.4 | 16.5 | 4/0-7 | 3883 | 192 | 948 | 1140 | 279 |
| Cassi | 4/0-19 | 2.03 | 13.4 | 17.5 | 4/0-7 | 3883 | 246 | 948 | 1194 | 279 |
| ACSR | ||||||||||
| Paludina | 6-Solid | 1.14 | 4.115 | 6.401 | 6-6/1 | 540 | 42 | 112 | 170 | 79 |
| Voluta | 6-7 | 1.14 | 4.67 | 6.960 | 6-6/1 | 540 | 48 | 112 | 176 | 79 |
| Bolma | 6-7 | 1.52 | 4.67 | 7.722 | 6-6/1 | 540 | 64 | 112 | 194 | 79 |
| Scallop | 6-Solid | 1.14 | 5.182 | 7.468 | 6-6/1 | 540 | 52 | 155 | 225 | 138 |
| Stombus | 4-7 | 1.14 | 5.89 | 8.179 | 6-6/1 | 540 | 60 | 155 | 232 | 138 |
| Carnea | 4-7 | 1.52 | 5.89 | 8.941 | 6-6/1 | 540 | 80 | 155 | 253 | 138 |
| Whelk | 4-Solid | 1.14 | 5.182 | 7.468 | 4-6/1 | 844 | 52 | 177 | 258 | 138 |
| Periwinkle | 4-7 | 1.14 | 5.89 | 8.179 | 4-6/1 | 844 | 60 | 177 | 263 | 138 |
| Calma | 4-7 | 1.52 | 5.89 | 8.941 | 4-6/1 | 844 | 80 | 177 | 284 | 138 |
| Cockle | 2-7 | 1.14 | 5.89 | 8.179 | 4-6/1 | 844 | 60 | 247 | 335 | 183 |
| Gebia | 2-7 | 1.52 | 5.89 | 8.941 | 4-6/1 | 844 | 80 | 247 | 354 | 183 |
| Conch | 2-7 | 1.14 | 5.89 | 8.179 | 2-6/1 | 1293 | 60 | 281 | 384 | 183 |
| Uca | 2-7 | 1.52 | 5.89 | 8.941 | 2-6/1 | 1293 | 80 | 281 | 405 | 183 |
| Vemeths | 1-7 | 1.52 | 8.33 | 11.379 | 1-6/1 | 1610 | 113 | 354 | 522 | 210 |
| Atya | 1-19 | 1.52 | 8.33 | 11.379 | 1-6/1 | 1610 | 113 | 430 | 524 | 210 |
| Janthina | 1/0-7 | 1.52 | 8.33 | 11.379 | 2-6/1 | 1293 | 113 | 393 | 549 | 242 |
| Ranella | 1/0-19 | 1.52 | 9.47 | 12.522 | 2-6/1 | 1293 | 130 | 393 | 566 | 242 |
| Neritina | 1/0-7 | 1.52 | 9.35 | 12.395 | 1/0-6/1 | 1987 | 128 | 448 | 644 | 242 |
| Cenia | 1/0-19 | 1.52 | 9.47 | 12.522 | 1/0-6/1 | 1987 | 130 | 448 | 646 | 242 |
| Cavolinia | 2/0-7 | 1.52 | 10.5 | 13.564 | 1-6/1 | 1610 | 146 | 496 | 697 | 279 |
| AAC | ||||||||||
| Halotis | 6-Solid | 1.14 | 4.115 | 6.4 | 6-7 | 255 | 42 | 110 | 152 | 78 |
| Pike | 6-7 | 0.76 | 4.67 | 6.2 | 6-7 | 255 | 31 | 112 | 143 | 78 |
| Fusus | 4-Solid | 1.14 | 5.182 | 7.5 | 4-7 | 400 | 52 | 177 | 229 | 103 |
| Oyster | 4-7 | 1.14 | 5.89 | 8.2 | 4-7 | 400 | 76 | 177 | 237 | 103 |
| Clam | 2-7 | 1.14 | 7.42 | 9.7 | 2-7 | 612 | 100 | 281 | 359 | 136 |
| Pyrula | 1-7 | 1.52 | 8.33 | 11.4 | 1-7 | 744 | 113 | 356 | 467 | 158 |
| Hyas | 1-19 | 1.52 | 8.43 | 11.5 | 1-7 | 744 | 115 | 356 | 469 | 158 |
| Murex | 1/0-7 | 1.52 | 9.35 | 12.4 | 1/0-7 | 903 | 128 | 385 | 513 | 182 |
| Purpura | 1/0-19 | 1.52 | 9.47 | 12.5 | 1/0-7 | 903 | 130 | 385 | 515 | 182 |
| Nasa | 2/0-7 | 1.52 | 10.52 | 13.6 | 2/0-7 | 1139 | 146 | 566 | 710 | 210 |
| Trophon | 2/0-7 | 1.52 | 10.64 | 13.7 | 2/0-7 | 1139 | 147 | 566 | 713 | 210 |
| Quahog | 3/0-7 | 2.03 | 11.79 | 15.9 | 3/0-7 | 1379 | 214 | 713 | 926 | 242 |
| Lone | 2/0-19 | 2.03 | 11.94 | 16 | 3/0-7 | 1379 | 217 | 713 | 929 | 242 |
| Melita | 3/0-19 | 1.52 | 11.94 | 15 | 3/0-19 | 1501 | 168 | 713 | 881 | 242 |
| Coquina | 4/0-7 | 1.52 | 13.26 | 16.3 | 4/0-7 | 1737 | 191 | 899 | 1089 | 279 |
| Tusk | 4/0-7 | 2.03 | 13.26 | 17.3 | 4/0-7 | 1737 | 243 | 899 | 1141 | 279 |
| Apus | 4/0-19 | 2.03 | 13.41 | 17.5 | 4/0-7 | 1737 | 246 | 899 | 1144 | 279 |
| Portunus | 4/0-19 | 1.52 | 13.41 | 16.5 | 4/0-19 | 1823 | 194 | 899 | 1091 | 279 |
| Chiton | 266.8-19 | 2.03 | 14.88 | 18.9 | 266.8-19 | 2254 | 277 | 1133 | 1409 | 310 |
| Nannynose | 336.4-19 | 2.03 | 16.92 | 21 | 336.4-19 | 2790 | 321 | 1427 | 1749 | 330 |
4.Packing
Packing in wooden drums,steel wooden drums or as customer’s requirement.
5.Customer Visit
We have a professional sales team with each of them has engaged in this job for 3-10 years, so that we can provide the comprehensive and professional technology for you. With the perfect quality and after sales service, till now we have exported to more than 80 countries, welcome to visit us and establish win-win establish relationship!
6.Certificate
As first rank of the cable supplier in China, we have obtained CCC, ISO9001, ISO14001, OHSAS certificates, passed the SGS and BV test, and our brand "RMJT" be given China famous brand.
7.About us:
People’s Cable Group Co., Ltd. was founded in 2007, located in Zhengzhou Gongyi economic development zone. Our company has 2 factories (Zhitian factory and Zhulin factory), occupies total area of more than 300,000 square meters, with building area 230,000 square meters.
8.Contacts
Vivian Wong| Project Manager | People’s Cable Group
Office Add:Room 1203 Building 4 East International Plaza No.85
Jinshui Road Zhengdong New Area Zhengzhou City Henan Province
Factory Add:No.13 Yongding Road Gongyi, Zhengzhou,China
T: 86-371-55632835 | M: 86-17719852022
We are China Aerial Bundled Cable-0.6/1kv Overhead Cable ABC Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 0.6/1kv Cable Products
0.6/1kv 3X120+1X70mm2 Copper Cable Supplier
LV ACSR/AAAC Conductor XLPE Covered Aerial Bundled Cable for Overhead Transmission Line
as/ASTM/NFC Standard 1kv 10kv Overhead Aerial Bundled Cable for Transmission Line
0.6/1kv 2nx Cable with 4 Cores
4 Core 95mm 120mm 0.6 /1kv Copper XLPE Armoured Underground Power Cable
Popular ABC Cable Products
3*35+35mm2 Aluminum Cable ABC Overhead Insulated Cable
XLPE Insulated 1kv 10kv Overhead Aerial Bundled Cable for Transmission Line
Aerial Bundle Cable ABC Cable Size Type Overhead
AAAC/AAC/ACSR/Acs/Gsw Overhead Conductor for Transmission Line Use
People′ S Cable Group of Best Selling Medium Voltage Aerial Bundled Cable
ABC Cable Aluminum Conductor XLPE Insulated Overhead Cable
Popular Overhead Cable Products
Duplex Triplex Twisted Aluminum Conductor XLPE Insulated ABC Cable
Mongolia AAAC Conductor Al Alloy Wire 95mm2
Astmb399 Bare 6201 AAAC Conductor 2AWG 7/2.67mm
Hard Drawn Conductor Overhead Conductor
100mm2 AAC PVC Insulated Wasp Conductor
0.6/1kv Low Voltage Aluminum Conductors 2/3/4 Cores Overhead Aerial Bundle XLPE ABC Cable
Popular renmincable Products
Types of Conductor Wire ACSR Conductor
Low Voltage Control Cables Shielded Multi Core Cable
Best Price Bare Aluminum Conductor ACSR From Factory Direct
2/3/4 Cores Low Voltage PVC Insulated Armoured Underground Cable
1.5mm2 2.5mm2 Electrical Wire Electr Cabl House Single Cable Electricity
Zr-Yjv XLPE Insulated Flame Retardant Power Cable
Tags: 0.6/1kv Cable, ABC Cable, Overhead Cable, renmincable