AAAC Aluminum Alloy Conductor is Used as bare overhead conductor for primary and secondary distribution. Designed utilizing a high-strength aluminum alloy to achieve a high strength-to-weight ratio; affords better sag characteristics. Aluminum alloy gives higher resistance to corrosion than ACSR.
Standard
BS EN50183,IEC 61089, ASTM B399,BS 3242, DIN 48204,GB/T1179-2008
Specification
Physical contents of aluminum alloy :-
1. Resistivity – 0.0326 Ohms mm2/m at 20°C
2. Density – 2.70 kgm/dm3 at 20°C
3. Coefficient of Linear Expansion – 23 x 10-6 / °C
4. Constant Mass Temperature Coefficient (a) – 0.00360/ °C
5. Material – Heat treated Al. Mg. Si. Alloy
– Approximately 0.5% Mg & 0.5% Si
ASTM B399
Code Name | Area | Size & Stranding of ACSR with Equal Diameter | No. & Diameter of wires | Overall Diameter | Weight | Nominal Breaking Load | ||
Nominal | Actual | |||||||
MCM | mm2 | AWG or MCM | Al/Steel | mm | mm | kg/km | kN | |
Akron | 30.58 | 15.48 | 6 | 6/1 | 7/1.68 | 5.04 | 42.7 | 4.92 |
Alton | 48.69 | 24.71 | 4 | 6/1 | 7/2.12 | 6.35 | 68.0 | 7.84 |
Ames | 77.47 | 39.22 | 2 | 6/1 | 7/2.67 | 8.02 | 108 | 12.45 |
Azusa | 123.3 | 62.38 | 1/0 | 6/1 | 7/3.37 | 10.11 | 172 | 18.97 |
Anaheim | 155.4 | 78.65 | 2/0 | 6/1 | 7/3.78 | 11.35 | 217 | 23.93 |
Amherst | 195.7 | 99.22 | 3/0 | 6/1 | 7/4.25 | 12.75 | 273 | 30.18 |
Alliance | 246.9 | 125.1 | 4/0 | 6/1 | 7/4.77 | 14.31 | 345 | 38.05 |
Butte | 312.8 | 158.6 | 266.8 | 26/7 | 19/3.26 | 16.30 | 437 | 48.76 |
Canton | 394.5 | 199.9 | 336.4 | 26/7 | 19/3.66 | 18.30 | 551 | 58.91 |
Cairo | 465.4 | 235.8 | 397.5 | 26/7 | 19/3.98 | 19.88 | 650 | 69.48 |
Darien | 559.5 | 283.5 | 477.0 | 26/7 | 19/4.36 | 21.79 | 781 | 83.52 |
Elgin | 652.4 | 330.6 | 556.5 | 26/7 | 19/4.71 | 23.54 | 911 | 97.42 |
Flint | 740.8 | 375.3 | 636.0 | 26/7 | 37/3.59 | 25.16 | 1035 | 108.21 |
Greely | 927.2 | 469.8 | 795.0 | 26/7 | 37/4.02 | 28.14 | 1295 | 135.47 |
IEC 61089
Code Number | A2 Conductor | A3 Conductor | Max.D.C. Resistance of Conductor at 20ºC | ||||||||
Number of Wires | Diameter of Wires | Diameter of Conductor | Approx. Weight | Rated Strength | Number of Wires | Diameter of Wires | Diameter of Conductor | Approx. Weight | Rated Strength | ||
mm² | – | mm | mm | kg/km | daN | – | mm | mm | kg/km | daN | Ω/km |
16 | 7 | 1.83 | 5.49 | 50.4 | 5.43 | 7 | 1.84 | 5.52 | 50.8 | 6.04 | 1.7896 |
25 | 7 | 2.29 | 6.87 | 78.7 | 8.49 | 7 | 2.30 | 6.9 | 79.5 | 9.44 | 1.1453 |
40 | 7 | 2.89 | 8.67 | 125.9 | 13.58 | 7 | 2.91 | 8.73 | 127.1 | 15.1 | 0.7158 |
63 | 7 | 3.63 | 10.8 | 198.3 | 21.39 | 7 | 3.65 | 10.95 | 200.2 | 23.06 | 0.4545 |
100 | 19 | 2.78 | 13.9 | 316.3 | 33.95 | 19 | 2.79 | 13.95 | 319.3 | 37.76 | 0.2877 |
125 | 19 | 3.10 | 15.5 | 395.4 | 42.44 | 19 | 3.12 | 15.6 | 399.2 | 47.20 | 0.2302 |
160 | 19 | 3.51 | 17.55 | 506.1 | 54.32 | 19 | 3.53 | 17.65 | 511.0 | 58.56 | 0.1798 |
200 | 19 | 3.93 | 19.65 | 623.7 | 67.91 | 19 | 3.95 | 19.75 | 638.7 | 73.20 | 0.1439 |
250 | 19 | 4.39 | 21.95 | 790.8 | 84.68 | 19 | 4.41 | 22.05 | 798.4 | 91.50 | 0.1151 |
315 | 37 | 3.53 | 24.71 | 998.9 | 106.95 | 37 | 3.55 | 24.85 | 1008.4 | 115.29 | 0.0916 |
400 | 37 | 3.98 | 27.86 | 1268.4 | 135.81 | 37 | 4.0 | 28 | 1280.5 | 146.4o | 0.0721 |
450 | 37 | 4.22 | 29.54 | 1426.9 | 152.79 | 37 | 4.24 | 29.68 | 1440.5 | 164.70 | 0.0641 |
500 | 37 | 4.45 | 31.15 | 1585.5 | 169.76 | 37 | 4.47 | 31.29 | 1600.6 | 183.oo | 0.0577 |
560 | 61 | 3.67 | 33.03 | 1778.4 | 190.14 | 61 | 3.69 | 33.21 | 1795.3 | 204.95 | 0.0516 |
630 | 61 | 3.89 | 35.01 | 2000.7 | 213.90 | 61 | 3.91 | 35.19 | 2019.8 | 230.58 | 0.0458 |
710 | 61 | 4.13 | 37.17 | 2254.8 | 241.07 | 61 | 4.15 | 37.35 | 2276.2 | 259.86 | 0.0407 |
800 | 61 | 4.38 | 39.42 | 2540.6 | 271.62 | 61 | 4.4 | 39.6 | 2564.8 | 282.80 | 0.0361 |
900 | 91 | 3.81 | 41.91 | 2861.1 | 305.58 | 91 | 3.83 | 42.13 | 2888.3 | 329.40 | 0.0321 |
1000 | 91 | 4.01 | 44.11 | 3179.0 | 339.53 | 91 | 4.03 | 44.33 | 3209.3 | 366.00 | 0.0289 |
1120 | 91 | 4.25 | 46.75 | 3560.5 | 380.27 | 91 | 4.27 | 46.97 | 3594.4 | 409.92 | 0 0258 |
1250 | 91 | 4.49 | 49.39 | 3973.7 | 424.41 | – | – | – | – |
BS EN50183
Code Name | Calculated Cross Section |
No..Dia.of Wires | Overall Diameter | Weight | Rated Strength |
mm² | No./mm | mm | kg/km | kN | |
Box | 18.8 | 7/1.85 | 5.55 | 51.4 | 5.55 |
Acacia | 23.8 | 7/2.08 | 6.24 | 64.9 | 7.02 |
Almond | 30.1 | 7/2.34 | 7.02 | 82.2 | 8.88 |
Cedar | 35.5 | 7/2.54 | 7.62 | 96.8 | 10.46 |
Deodar | 42.2 | 7/2.77 | 8.31 | 115.2 | 12.44 |
Fir | 47.8 | 7/2.95 | 8.85 | 130.6 | 14.11 |
Hazel | 59.9 | 7/3.30 | 9.90 | 163.4 | 17.66 |
Pine | 71.6 | 7/3.61 | 10.8 | 195.6 | 21.14 |
Holly | 84.1 | 7/3.91 | 11.7 | 229.5 | 24.79 |
Willow | 89.7 | 7/4.04 | 12.1 | 245,0 | 26.47 |
Oak | 118.9 | 7/4.65 | 14.0 | 324.5 | 35.07 |
Mulberry | 150.9 | 19/3.18 | 15.9 | 414.3 | 44.52 |
Ash | 180.7 | 19/3.48 | 17.4 | 496.1 | 53.31 |
Elm | 211.0 | 19/3.76 | 18.8 | 579.2 | 62.24 |
Poplar | 239.4 | 37/2.87 | 20.1 | 659.4 | 70.61 |
Sycamore | 303.2 | 37/3.23 | 22.6 | 835.2 | 89.40 |
Upas | 362.1 | 37/3.53 | 24.7 | 997.5 | 106.82 |
Yew | 479.0 | 37/4.06 | 28.4 | 1319.6 | 141.31 |
Totara | 498.1 | 37/4.14 | 29.0 | 1372.1 | 146.93 |
Rubus | 586.9 | 61/3.50 | 31.5 | 1622.0 | 173.13 |
Sorbus | 659.4 | 61/3.71 | 33.4 | 1822.5 | 194.53 |
Araucaria | 821.1 | 61/4.14 | 37.3 | 2269.4 | 242.24 |
Redwood | 996.2 | 61/4.56 | 41.0 | 2753.2 | 293.88 |
Din 48201
Code number | Calculated area | Number of wires | Diameter of wire | Overall diameter of conductor | Linear mass | Rated tensile strength | Max. DC resistance at 20ºC |
mm2 | mm2 | mm | mm | kg/km | daN | Ω/km | |
16 | 15.89 | 7 | 1.70 | 5.1 | 43 | 444 | 2.0910 |
25 | 24.25 | 7 | 2.10 | 6.3 | 66 | 677 | 1.3703 |
35 | 34.36 | 7 | 2.50 | 7.5 | 94 | 960 | 0.9669 |
50 | 49.48 | 7 | 3.00 | 9.0 | 135 | 1382 | 0.6714 |
50 | 48.35 | 19 | 1.80 | 9.0 | 133 | 1350 | 0.6905 |
70 | 65.81 | 19 | 2.10 | 10.5 | 181 | 1838 | 0.5073 |
95 | 93.27 | 19 | 2.50 | 12.5 | 256 | 2605 | 0.3579 |
120 | 116.99 | 19 | 2.80 | 14.0 | 322 | 3268 | 0.2854 |
150 | 147.11 | 37 | 2.25 | 15.8 | 406 | 4109 | 0.2274 |
185 | 181.62 | 37 | 2.50 | 17.5 | 500 | 5073 | 0.1842 |
240 | 242.54 | 61 | 2.25 | 20.3 | 670 | 6774 | 0.1383 |
300 | 299.43 | 61 | 2.50 | 22.5 | 827 | 8363 | 0.1120 |
400 | 400.14 | 61 | 2.89 | 26.0 | 1104 | 11176 | 0.0838 |
500 | 499.63 | 61 | 3.23 | 29.1 | 1379 | 13960 | 0.06709 |
625 | 626.20 | 91 | 2.96 | 32.6 | 1732 | 17490 | 0.0540 |
800 | 802.09 | 91 | 3.35 | 36.9 | 2218 | 22402 | 0.0418 |
1000 | 999.71 | 91 | 3.74 | 41.1 | 2767 | 27922 | 0.0335 |
We are China All Aluminum Alloy Conductor AAAC ASTM BS IEC DIN CSA 4AWG manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular AAAC 4AWG Products
4AWG Alton AAAC All Aluminum Alloy Conductor/Bare Conductor/Overhead Conductor
Overhead Bare Conductor 6201 AAAC 4AWG ASTM B399
Bare Aluminum Alloy Conductor AAAC 4AWG
Popular AAAC Conductor 4AWG Products
Popular All Aluminium Alloy Conductor 4AWG Products
Popular huatongcable Products
450/750V Electric Wires VV Model Building Flexible Electrical Wires Factory Price
Power Cablehalogen-Free, Flame Retardant Tfl492322/0
IEC 60227 Copper Conductor PVC Insulation Electric Wire RV 0.75mm2
2 4 6 8 10 12 14 16 AWG Guage Copper Stranded Wire
PVC/XLPE Insulated Aerial Bundled Cable, ABC Cable, Overhead Cable, ASTM, BS, NFC, IEC, DIN Standard
Tags: AAAC 4AWG, AAAC Conductor 4AWG, All Aluminium Alloy Conductor 4AWG, huatongcable