Aluminium Duplex/Triplex/Quadruplex Overhead Service Drop 600V
Aluminium Duplex/Triplex/Quadruplex Overhead Service Drop 600V image
Get Latest Price Request a quote
Quick Details
Product Details
Aluminium Conductors. Polythylene or Crosslinked Polyethylene Insulation.
ABC Cables Applications:
Used to supply 3 phase power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75° C for polyethylene insulated conductors or 90° C for crosslinked polyethylene (XLP) insulated conductors.
ABC Cables Construction:
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR. One conductor is manufactured with an extruded ridge for phase identification.
ABC Cables Standards:
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
ABC Cables Using Properties
1. Rated Voltage: 0.6/1kV
2. Cable installation temperature not less than -20° C
3. Max. Temperature of cable at short circuit(The max. Duration does not exceed 5 minutes)
For XLPE insulation is 250° C.
For HDPE insulation is 150 ° C.
4. The Max. Bending radius of cable shall not be less than 20Dmm(D overall diameter of cable)
Type of ABC Cable
1. Duplex Service Drop: To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.
2. Triplex Service Drop: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.
3. Quadruplex Service Drop: Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
We are China Aluminium Duplex/Triplex/Quadruplex Overhead Service Drop 600V manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 600V Products
600V Aluminum Conductor AAAC 6201 Alloy Neutral Messenger Triplex Service Drop Cable
Ser/Seu Concentric Cable /Service Entrance Cable Flat 8+8AWG
Wind Turbine Tc Tc-Er Tray Cable High Voltage Low Temperature Wind Energy Cable
Unarmored Tray Cable Tc (XHHW-2) 600V Tc-Er VFD XLPE/PVC Multi Conductor
UL1277 Tc Tc-Er Power and Control Tray Cable Dual Rated Wind Turbine Wire XLPE/PE Sheath
Popular huatongcable Products
Aluminum Conductor ACSR Linnet 336.4mcm
Flexible Copper Core PVC Insulated Electric Wire
12/20kv Underground Single Core Copper Armored Electric Cable
795 Mcm Huatong Cable Aluminum Conductor Steel Reinforced ACSR
6/10kv Single Core Alumininum Core XLPE Insulated Power Cable
Popular Overhead Products
Power /PVC/XLPE/Overhead/Aluminum Conductor/Aerial Bundle Cable
Bare Conductor for Overhead Conductor Acar 900 Mcm ASTM Standard
Overhead Electrical Transmission Low Voltage ABC Bundled Cables
0.6-10kv Aluminum Overhead ABC Power Cable /Aerial Bounded Cable
Bare Conductor for Overhead Conductor ACSR 1/0 AWG ASTM Standard
Aluminum Overhead Power Bare Conductor ACSR
Popular Service Drop 600V Products
Triplex ABC Cable Service Drop 600V 2X1/0+1/0AWG Cable
Tags: 600V, huatongcable, Overhead, Service Drop 600V