Aluminium Urd Cable XLPE/PE Insulation
Aluminium Urd Cable XLPE/PE Insulation image
Get Latest Price Request a quote
Quick Details
Product Details
Aluminium Conductors. Polythylene or Crosslinked Polyethylene Insulation.
ABC Cables Applications:
Used to supply 3 phase power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.
ABC Cables Construction:
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR.One conductor is manufactured with an extruded ridge for phase identification.
ABC Cables Standards:
1.B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2.B-231 Aluminum conductors, Concentric-Lay-Stranded.
3.B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
4.B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
5.B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6.Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
ABC Cables Using Properties
1.Rated Voltage:0.6/1kV
2.Cable installation temperature not less than -20°C
3.Max. temperature of cable at short circuit(The max. duration does not exceed 5 minutes)
For XLPE insulation is 250°C.
For HDPE insulation is 150 °C.
4.The Max. bending radius of cable shall not be less than 20Dmm(D overall diameter of cable)
Type of ABC Cable
1.Duplex Service Drop:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75 maximum.
2.Triplex Service Drop: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation .
3.Quadruplex Service Drop: Used to supply 3 phase power , usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made . To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
ASTM B-230, B-231 and ICEA S-66-524
UL Standard 854 for type USE
Federal Specification JC-30B NEC
|
Code Name |
Phase Conductor |
Neutral |
Single Phase Conductor(in) |
Outside diameter(in) |
Weight Per 1000ft (lbls) |
Ampacity |
|||||
|
Size AWG |
Strand |
Insulation Thickness (mls) |
Size AWG |
Strand |
Insulation Thickness (mls) |
Direct Burial |
In Duct |
||||
|
Tulsa |
4 |
7/w |
60 |
4 |
7/w |
60 |
.345 |
.833 |
258 |
119 |
85 |
|
Dyke |
2 |
7/w |
60 |
4 |
7/w |
60 |
.403 |
.938 |
346 |
153 |
115 |
|
Wittenberg |
2 |
7/w |
60 |
2 |
7/w |
60 |
.403 |
.973 |
375 |
153 |
115 |
|
Notre Dame |
1/0 |
19/w |
80 |
2 |
7/w |
60 |
.522 |
1.188 |
541 |
198 |
150 |
|
Purdue |
1/0 |
19/w |
80 |
1/0 |
19/w |
80 |
.522 |
1.260 |
596 |
198 |
150 |
|
Syracuse |
2/0 |
19/w |
80 |
1/0 |
19/w |
80 |
.566 |
1.316 |
664 |
225 |
170 |
|
Lafayette |
2/0 |
19/w |
80 |
2/0 |
19/w |
80 |
.566 |
1.367 |
720 |
225 |
170 |
|
Swarthmore |
3/0 |
19/w |
80 |
1/0 |
19/w |
80 |
.616 |
1.430 |
805 |
250 |
195 |
|
Davidson |
3/0 |
19/w |
80 |
3/0 |
19/w |
80 |
.616 |
1.487 |
874 |
250 |
195 |
|
Wake Forest |
4/0 |
19/w |
80 |
2/0 |
19/w |
80 |
.672 |
1.560 |
979 |
290 |
225 |
|
Earlham |
4/0 |
19/w |
80 |
4/0 |
19/w |
80 |
.672 |
1.623 |
1066 |
290 |
225 |
|
Slippery Rock |
350 |
37/w |
95 |
4/0 |
19/w |
80 |
.851 |
1.945 |
1544 |
385 |
305 |
|
Wofford |
500 |
37/w |
95 |
350 |
37/w |
95 |
.851 |
2.348 |
2174 |
467 |
420 |
|
Windham |
750 |
61/w |
110 |
500 |
37/w |
95 |
.979 |
2.850 |
2542 |
615 |
492 |
We are China Aluminium Urd Cable XLPE/PE Insulation manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular ABC Cable Products
Overhead Power Transmission Lines Conductors ABC Triplex Bundled Cables
Duplex 1*16+16mm2 ABC Cable for Use Overhead
95mm2 New Self-Supporting ABC Cable
Aluminium Conductor Steel Reinforced with XLPE / PE ABC Cable
ABC Cable --Aerial Bundled Cable
Popular huatongcable Products
All Aluminum Alloy Conductor AAAC ASTM BS IEC DIN CSA 48.69 Kcmil Alton
Single Core 0.6/1kv Copper Core PVC Insulation Overhead Cable
12/20kv Overhead Single Core Medium Voltage Aerial Spacer Cables
Quadruplex Service Drop Aluminum Conductors ACSR Neutral-Messenger Cable
6.35/11kv Underground Single Core Copper Armored Electric Cable 300mm2
Power Transmission Cable, Bare Conductor AAAC Cable for Overhead Use
Popular Powe Cable Products
Power Distribution Aerial Isolated ABC Cable
0.6/1kv 3 Cores Aluminum /PVC Insulated Power Cable
Multi Cores Aluminum Cores PVC Insulated Power Cable
Power Distribution Aluminium Urd Cable
ASTM Standard Urd Cable PE/XLPE Insulation
ABC Cable Aerial Bunched/Bundled Cable
Popular Urd Cable Products
UL Listed Underground Mv 105 5kv 8kv 15kv 25kv 28kv Aluminum Distribution Power Urd Cable
33kv XLPE Power Cable Single Core Mv Cable
Aluminum Conductor Overhead Insulated ABC Cable
UL1072 Standard Urd Cable 1 Core Medium Voltage Power Cable Underground Mv-90 Mv-105 Cable
UL854 Single/Duplex/Triplex/Quadruplex Aluminum Conductor 600V Urd
1/0 15kv Tr Xlp Urd Aluminum Cable Direct Burial Medium Voltage Cable with UL1072 Standard
Tags: ABC Cable, huatongcable, Powe Cable, Urd Cable