Aluminum Conductor Power Cable AAAC Conductor with ASTM BS IEC Standard for Hot Sale!

China 
                        Aluminum Conductor Power Cable AAAC Conductor with ASTM BS IEC Standard for Hot Sale!
                      manufacture and supplier

Aluminum Conductor Power Cable AAAC Conductor with ASTM BS IEC Standard for Hot Sale! image

Get Latest Price Request a quote

Quick Details

Aluminum Conductor Power Cable AAAC Conductor with ASTM BS IEC Standard for Hot Sale!

aaac

Huatong

ISO9001, CE, CCC, RoHS, VDE

Flame Retardant

Round Wire

Bare

No

Aluminum

Overhead

Stranded

Bare

as Per Your Customers ' Request

LV. Mv. Hv

AAAC Conductor

Within 15-20 Days

IEC ,ASTM ,BS

Wooden ,Wooden -Steel ,Steel

Good appearance

Electric Transmission

Huatong

All Wooden, Steel Wooden or Steel Package

in China

76141000

Product Details

Aluminum Conductor Power Cable AAAC Conductor with ASTM BS IEC Standard for hot sale !
1.Specifications
AAAC bare conductor meets or exceeds the following ASTM specifications :

B-398 Aluminum Alloy 6201-T81 Wire for Electrical Purposes
B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
AAAC All aluminium alloy conductors
standard:B-398,B-399,Ardival, Aldrey or Almelec
overhead for primary,secondary power line.
AAAC All aluminium alloy conductors for American B-398/ B-399 standard
Detailed Product Description
2.Applications
It can replace part of aluminum conductors or ACSR for overhead distribution lines .Temperature for continuours use is up to 90 ºC.Temperature of heat-resistance aluminum alloy strands is up to 150 ºC and above .It has high current carrying capacity and good corrosion performance.
Construction
Standard 6201-T81 high strength aluminum conductors, conforming to ASTM Specification B-399, are concentric-lay- stranded, similar in construction and appearance to 1350 grade aluminum conductors. Standard 6201 alloy conductors are similar to other alloy conductors commercially known as Ardival, Aldrey or Almelec. They were developed to fill the need for an economical conductor for overhead applications requiring higher strength than that obtainable with 1350 grade aluminum conductors, but without a steel core. The DC resistance at 20°C of the 6201-T81 conductors and of the standard ACSRs of the same diameter are approximately the same. Conductors of the 6201-T81 alloys are harder and, therefore, have a greater resistance to abrasion than conductors of 1350-H19 grade aluminum.

AAAC Conductor  (All Aluminium Alloy Conductor) 20years manufacture experience,we can produce as per the standard:IEC, GB,BS,ASTM,DIN,NF,JIS.We can also customize the special size according to the customer’s special request.

Hot sale to Africa,Southeast Asia,North America

Total Area Overall Diameter
AWG or MCM mm mm
6 13.3 4.65
4 21.1 5.88
2 33.6 7.41
0 53.5 9.36
2/0 67.4 10.50
3/0 85.0 11.79
4/0 107.2 13.26
250 126.7 14.55
300 152.0 15.95
350 177.3 17.25
400 202.7 18.45
450 228.0 19.55
500 253.4 20.60
550 278.7 21.70
600 304.0 22.61
650 329.4 23.59
700 354.7 24.43
750 380.0 25.34
800 405.4 26.11
900 456.0 27.72

      AAAC– ASTM B399 standard

Area No./wire diameter Overall diameter Weight Nominal breaking load Max D.C. resistance at 20ºC Standard length
Nominal Actual
AWG or MCM mm2 mm mm Kg/km KN Ω/km m±5%
6 13.30 7/1.554 4.67 37 4.22 2.5199 3500
4 21.15 7/1.961 5.89 58 6.71 1.5824 3000
2 33.63 7/2.474 7.42 93 10.68 0.9942 2500
1/0 53.48 7/3.119 9.36 148 16.97 0.6256 2000
2/0 67.42 7/3.503 10.51 186 20.52 0.4959 3500
3/0 85.03 7/3.932 11.80 234 25.86 0.3939 3000
4/0 107.23 7/4.417 13.26 296 32.63 0.3119 2000
250 126.66 19/2.913 14.57 349 38.93 0.2642 2000
300 152.10 19/3.193 15.97 419 46.77 0.2199 3000
350 177.35 19/3.447 17.24 489 52.25 0.1887 3000
400 202.71 19/3.686 18.43 559 59.74 0.1650 2500
450 228.00 19/3.909 19.66 629 67.19 0.1467 2000
500 253.35 19/4.120 20.60 698 74.64 0.1321 2000
550 278.60 37/3.096 21.67 768 83.80 0.1202 2000
600 303.80 37/3.233 22.63 838 91.38 0.1102 2000
650 329.25 37/3.366 23.56 908 97.94 0.1016 2000
700 354.55 37/3.493 24.45 978 102.20 0.0944 3500
750 380.20 37/3.617 25.32 1049 109.60 0.0880 3000
800 405.15 37/3.734 26.14 1117 116.80 0.0826 3000
900 456.16 37/3.962 27.73 1258 131.50 0.0733 3000
1000 506.71 37/4.176 29.23 1399 146.10 0.0660 2500

                                               
Standard: BS EN50183

Code name Calculated area No of wires Diameter Weight Rated strength Max D.C.
resistance at 20ºC
Wire Cond
  mm2   mm mm Kg/km KN Ω/km
Box 18.8 7 1.85 5.55 51.4 5.55 1.7480
Acacia 23.8 7 2.08 6.24 64.9 7.02 1.3828
Almond 30.1 7 2.34 7.02 82.2 8.88 1.0926
Cedar 35.5 7 2.54 7.62 96.8 10.46 0.9273
Deodar 42.2 7 2.77 8.31 115.2 12.44 0.7797
Fir 47.8 7 2.95 8.85 130.6 14.11 0.6875
Hazel 59.9 7 3.30 9.90 163.4 17.66 0.5494
Pine 71.6 7 3.61 10.8 195.6 21.14 0.4591
Holly 84.1 7 3.91 11.7 229.5 24.79 0.3913
Willow 89.7 7 4.04 12.1 245.0 26.47 0.3665
Oak 118.9 7 4.65 14.0 324.5 65.07 0.2767
Mulberry 150.9 19 3.18 15.9 414.3 44.52 0.2192
Ash 180.7 19 3.48 17.4 496.1 53.31 0.1830
Elm 211.0 19 3.76 18.8 579.2 62.24 0.1568
Poplar 239.4 37 2.87 20.1 659.4 70.61 0.1387
Sycamore 303.2 37 3.23 22.6 835.2 89.40 0.1095
Upas 362.1 37 3.53 24.7 997.5 106.82 0.0917
Yew 479.0 37 4.06 28.4 1319.6 141.31 0.0693
Totara 498.1 37 4.14 29.0 1372.1 145.93 0.0666
Rubus 586.9 61 3.50 31.5 1622.0 173.13 0.0567
Sorbus 659.4 61 3.71 33.4 1822.5 194.53 0.0505
Araucaria 821.1 61 4.14 37.3 2269.4 242.24 0.0406
Redwood 996.2 61 4.56 41.0 2753.2 293.88 0.0334

3.Overhead Conductors
(1).What is the difference between ACSR, AAC and AAAC Conductors?
The biggest difference between AAC, AAAC, and ACSR conductors are the materials they are constructed from. AAC is manufactured from electrolytically refined aluminium with a 99.7% minimum purity, AAAC is made from an Aluminium alloy, and ACSR contains a combination of Aluminium reinforced with Steel.
 
The second factor that differentiates the three cables is their resistance to corrosion, which is important for the longevity of the cable. ACSR has a poorer resistance to corrosion, as it contains steel, which is prone to rust. AAAC and AAC have a better corrosion resistance, due to the fact that they are largely or completely aluminium.
 
In an ACSR the galvanised steel core carries the mechanical load and the high purity aluminium carries the current. These utilise the lower thermal expansion coefficient of steel compared to aluminium, which the aluminium based conductors AAC and AAAC are unable to do.
 
(2). What do ACSR, AAC and AAAC Conductors have in common?
ACSR, AAC and AAAC are all used in overhead line applications, and although for different specific applications, they are all involved in power distribution.
4.About us :

We are China Aluminum Conductor Power Cable AAAC Conductor with ASTM BS IEC Standard for Hot Sale! manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular AAAC Conductor Products

AAAC Conductor DIN 48201 All Aluminum Alloy Conductor Bare Conductor for Overhead Transmission Lines

BS 3242 Aluminum Alloy Conductors for Overhead Power Transmission Almond

IEC NFC Standard Cable Aluminum Alloy Conductor AAAC

Overhead ACSR, AAC, AAAC, Acss/Tw, Accc, Aacsr, Acar, Opgw Bare Conductor

ASTM B399 Bare All Aluminium Alloy Conductor AAAC

BS Standard AAAC Pine Conductor Aluminum Alloy Overhead Conductor

Popular Aluminum Products

GBT/ASTM Standard Aluminum/Aluminium Plate/Sheet 5052/5083/6061/6082/7075/ for Export

High Voltage AAC/ACSR Cable to IEC61089, BS215, ASTM B232, CSA C49, DIN48204, JIS C3110 Standard

Aluminum Alloy Steel Suspension Bracket Pole Line Hardware

Aluminum Alloy Dead End Clamp Nld-3 (Bolt Type)

Cable Suspension Clamp Aluminum

0.6/1 Kv Henan Jscable Screened Low Voltage Halogen Free Aluminum Power Cables

Popular Cable Wires Products

0.6/1kv 95mm2 120mm2 150mm2 Stranded Copper Wires Conductor Aluminum Conductor XLPE Insulation PVC Cable

2.5mm 450/750V PVC Insulated Copper Wire, Electric House Wire, Cable Wires

AAAC Cables Wires All Aluminum Alloy Conductor Bare Stranded

0.6/1kv Stranded Copper Wires Conductor Aluminum Conductor XLPE Insulation PVC Cable

Flexible Solid Stranded Copper Aluminium PVC Insulated Electric Cable Wires

2.5mm 4mm 6mm 10mm 450/750V PVC Insulated Copper Wire, Electric House Wire, Cable Wires

Popular huatongcable Products

450/750V Wires, Electrical Wire High Quality PVC Cover Building Wire

Housing Wire Electrical House Wiring Green Yellow Ground Wire

Holly/Ash/Yew/Rabue Bare AAAC Conductor with BS En 50183

Overhead Aacsr (Aluminum-Alloy Conductors Steel Reinforced) ASTM B711

Al/St ACSR Conductor, B232 Standard Overhead Cable

Factory Price for Aluminum Conductor Alloy Reinforced Acar 700mcm Astmb 398 Standard