Aluminum Conductor XLPE Insulated ABC Cable (IEC, ASTM, Sans Standards)
Aluminum Conductor XLPE Insulated ABC Cable (IEC, ASTM, Sans Standards) image
Get Latest Price Request a quote
Quick Details
Product Details
ASTM BS Standard 0.6/1kv pvc/xlpe/pe insulatedDuplex aerial bundle cable, abc cable
We can supply this conductor according to different recognized standards, such as IEC Standard, ANSI/ICEA , NFC, NBR, ITP ,customer special specification also can be satisfied.
Application: ABC cable Conllie, duplex cable, service drop, overhead cable.
The basic construction is as following:
A, 2, 3, 4 power cores consisting of strandard aluminium conductor, insulated with XLPE or PVC, PE.
B, One sheath lighting aluminium conductor with XLPE insulation(optional)
C, One messenger Al-alloy (bare or covered)
It meets or exceeds the following specification:
A, Aluminium wire, 1350-H19 for electrical purposes.
B, Aluminium conductor, concentric-lay-stranded.
C, Aluminium conductor, concentric-lay-stranded, coated steel reinforgorced(ACSR, AAC, AAAC)
D, Concentric-lay stranded 6201-T81 conductors.
E, Compressed Round Stranded Aluminium consuctors using single input wire.
Specifications:
Conductor: Aluminum
Insulation: PVC, XLPE, PE
Application: Overhead line
Core: 2.3, 4 core( Duplex, triplex, quoduplex)
|
Code word |
AWG or kcmil |
Bare Neutral Messenger | Phase Conductor | Weight Kg/km |
Allowable Ampacities(A) |
|||||||
| ACSR | Rated strength Ibs. | AAC | Insul Thick. mm |
XLPE |
PE |
|||||||
| Number | Dia mm | Number | Dia mm | Number | Dia mm | |||||||
| Setter | 1*6AWG+1*6AWG | 1 | 1.68 | 6 | 1.68 | 1190 | 1 | 4.11 | 1.14 | 111 | 85 | 70 |
| Bull | 1*1/0AWG+1*1/0AWG | 1 | 3.37 | 6 | 3.37 | 4380 | 19 | 1.89 | 1.52 | 427 | 205 | 160 |
| Shepherd | 1*6AWG+1*6AWG | 1 | 1.68 | 6 | 1.68 | 1190 | 7 | 1.56 | 1.14 | 113 | 85 | 70 |
| Eskimo | 1*4AWG+1*4AWG | 1 | 2.12 | 6 | 2.12 | 1860 | 1 | 5.19 | 1.14 | 171 | 115 | 90 |
| Terrier | 1*4AWG+1*4AWG | 1 | 2.12 | 6 | 2.12 | 1860 | 7 | 1.96 | 1.14 | 173 | 115 | 90 |
| Chow | 1*2AWG+1*2AWG | 1 | 2.67 | 6 | 2.67 | 2850 | 7 | 2.47 | 1.14 | 266 | 150 | 120 |
Aerial Bundle Conductor-ABC(South Africa Standard Sizes)-SANS 1418-1
Table 01
| Type of conductor or core | Norminal cross-sectional area mm2 | Nubmer of wires Min. |
Diameter of conductormm | Resistanceat 20ºC Ω/km Max. | Breaking force(N) | Thickness of insulation (mm) | Outer diameter of core(mm) | |||
| Min. | Max. | Min. | Average | Min. | Min. | Max. | ||||
| Phase or auxiliary or non-strain-bearing netural(aluminium) | +16 | 6 | 4.6 | 5.1 | 1.91 | 2070 | 1.2 | 0.98 | 7.0 | 7.8 |
| 25 | 6 | 5.8 | 6.3 | 1.2 | 3300 | 1.4 | 1.16 | 8.6 | 9.4 | |
| 35 | 6 | 6.8 | 7.3 | 0.868 | 4500 | 1.6 | 1.34 | 10.0 | 10.9 | |
| 50 | 6 | 7.9 | 8.4 | 0.641 | 6200 | 1.6 | 1.34 | 11.1 | 12.0 | |
| 70 | 12 | 9.7 | 10.2 | 0.443 | 8900 | 1.8 | 1.52 | 13.3 | 14.2 | |
| 95 | 15 | 11.0 | 12.0 | 0.320 | 12300 | 1.8 | 1.52 | 14.6 | 16.0 | |
| 120 | 15 | 12.5 | 13.5 | 0.253 | 15600 | 1.8 | 1.52 | 16.3 | 17.5 | |
| 150 | 15 | 13.9 | 15.0 | 0.206 | 19200 | 1.8 | 1.52 | 17.1 | 18.6 | |
| Service connection(aluminium) | 16 | 6 | 4.6 | 5.2 | 1.91 | 2070 | 1.2 | 0.98 | 7.0 | 8.0 |
| 25 | 6 | 5.6 | 6.5 | 1.2 | 3300 | 1.4 | 1.16 | 8.6 | 9.6 | |
| Service connection(copper) | 10 | 6 | – | 4.2 | 1.83 | 3600 | 1.2 | 0.98 | 6.2 | 7.0 |
| 16 | 6 | – | 5.3 | 1.15 | 5760 | 1.2 | 0.98 | 7.2 | 8.0 | |
| 25 | 6 | – | 6.6 | 0.727 | 8750 | 1.4 | 1.16 | 8.6 | 9.6 | |
| Number and nominal diameter of wires mm |
||||||||||
| Supporting core(aluminium alloy) |
54.6 | 7×3.15 | 9.2 | 9.6 | 0.630 | 16600 | 1.6 | 1.34 | 12.3 | 13.0 |
| 70 | 7×3.50 | 10.0 | 10.4 | 0.500 | 20100 | 1.6 | 1.34 | 12.9 | 13.6 | |
| +Auxiliary conductors or cores only | ||||||||||
When a supporting core is specified in a tender invitation,the combinations listed in Table 02 below:
Table 02
| 1 | 2 |
| Nominal cross sectional area of supporting conductor mm2 | Nominal cross-sectional areas of phase conductors mm2 |
| 54.6 | 25,35,50,70,95 |
| 70 | 70,95,120 |
| 95 | 95,120,150 |
—————————————————————————————————————————–
Aerial Bundle Conductor-ABC(South Africa Custimized Size Specification)
Table 03
| Type of conductor or core | Norminal cross-sectional area mm2 | Nubmer of wires | Diameter of conductormm | Resistanceat 20ºC Ω/km Max. | Breaking force(N) | Thickness of insulation (mm) | Outer diameter of core(mm) | |||
| Min. | Max. | Min. | Average | Min. | Min. | Max. | ||||
| Phase or auxiliary or non-strain-bearing netural(aluminium) | 16 | 7/1.65 | 4.6 | 5.1 | 1.91 | 2070 | 1.2 | 0.98 | 7.0 | 7.8 |
| 25 | 7/2.15 | 5.8 | 6.3 | 1.2 | 3300 | 1.4 | 1.16 | 8.6 | 9.4 | |
| 35 | 7/2.55 | 6.8 | 7.3 | 0.868 | 4500 | 1.6 | 1.34 | 10.0 | 10.9 | |
| 50 | 7/2.99 | 7.9 | 8.4 | 0.641 | 6200 | 1.6 | 1.34 | 11.1 | 12.0 | |
| 70 | 14/2.59 | 9.7 | 10.2 | 0.443 | 8900 | 1.8 | 1.52 | 13.3 | 14.2 | |
| 95 | 19/2.59 | 11.0 | 12.0 | 0.320 | 12300 | 1.8 | 1.52 | 14.6 | 16.0 | |
| 120 | 19/2.99 | 12.5 | 13.5 | 0.253 | 15600 | 1.8 | 1.52 | 16.3 | 17.5 | |
| 150 | 30/2.59 | 13.9 | 15.0 | 0.206 | 19200 | 1.8 | 1.52 | 17.1 | 18.6 | |
| Service connection(aluminium) | 16 | 7/1.65 | 4.6 | 5.2 | 1.91 | 2070 | 1.2 | 0.98 | 7.0 | 8.0 |
| 25 | 7/2.15 | 5.6 | 6.5 | 1.2 | 3300 | 1.4 | 1.16 | 8.6 | 9.6 | |
| Service connection(copper) | 10 | 7/1.35 | – | 4.2 | 1.83 | 3600 | 1.2 | 0.98 | 6.2 | 7.0 |
| 16 | 7/1.69 | – | 5.3 | 1.15 | 5760 | 1.2 | 0.98 | 7.2 | 8.0 | |
| 25 | 7/2.19 | – | 6.6 | 0.727 | 8750 | 1.4 | 1.16 | 8.6 | 9.6 | |
| Supporting core(aluminium alloy) | 16 | 7/1.71 | 5.1 | 5.2 | 2.053 | 5070 | 1.4 | 1.16 | 7.9 | 8.0 |
| 25 | 7/2.15 | 6.4 | 6.5 | 1.314 | 8000 | 1.4 | 1.16 | 9.2 | 9.3 | |
| 35 | 7/2.48 | 6.6 | 7.5 | 0.986 | 10300 | 1.6 | 1.34 | 10.7 | 10.8 | |
| 50 | 7/2.89 | 7.7 | 8.4 | 0.720 | 14200 | 1.6 | 1.34 | 11.9 | 12.0 | |
| 54.6 | 7/3.15 | 9.2 | 9.6 | 0.630 | 16600 | 1.6 | 1.34 | 12.3 | 13.0 | |
| 70 | 7/3.50 | 10.0 | 10.4 | 0.500 | 20100 | 1.6 | 1.34 | 12.9 | 13.6 |
|
We are China Aluminum Conductor XLPE Insulated ABC Cable (IEC, ASTM, Sans Standards) manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular ABC Products
Overhead Insulated Aerial Bundle Service Drop Triplex ABC Cable with High Quality
ACSR AAC Conductor Overhead Aerial Bundled Cable 3 Cores ABC Cable
PVC/XLPE Insulated Overhead Aerial Bundle Cable with Aluminium Conductor
0.6/1kv LV Cable ABC Alumminum Electric Wire XLPE Insulated Aerial Bundled Power Cable
High Quality Duplex/Quadruplex/Triplex ABC Aerial Bundled Cable
CABO BT 0.6/1kV LXS 2x16mm2 Aluminum Conductor XLPE Insulation Aerial Bundled Cable
Popular ABC Cable Products
ABC Overhead Aerial Bundle Transmission and Distribution Cable ABC
High Voltage 33kv Copper Conductor, XLPE Insulated Power Cable
Aerial Bundled Cable (ABC) for Electrical Overhead Power Transmission 0.6/1kv
PE/XLPE/PVC Insulated 0.6/1kv 95mm2 Overhead ABC Cable
Triplex Service Drop AAAC 6201 Alloy Neutral Conductor Flustra
Popular Aerial Bundled Cable Products
2/0AWG 15kv Urd Power Cable for Underground Distribution
Overhead Transmission ABC Cable to Sans 1418 Size 3X95+54.6
Aluminum Core PVC Insulated Overhead Cable 3*50+1*50mm
Triplex Overhead Aerial Bundled Aluminum Cables Urd Wire for AAC/ AAAC/ACSR Cable
Popular jytopcable Products
11kv Swa Cable 3X150mm with CE Certificate
Middle Voltage XLPE Insulated Copper Cable with Steel Tape Armored
House Residential Copper PVC Insualted Flexible Electrical Building Wire
XLPE Insulated Aluminum Overhead Duplex Aerial Bundled Triplex ABC Cable
Medium Voltage 10kv Cable, 10kv Copper Cable Factory
H03VV-R Copper Conductor PVC Insulated PVC Sheathed Electric Wire
Tags: ABC, ABC Cable, Aerial Bundled Cable, jytopcable