American Service Drop Cable 0.6/1kv Urd Cable for Transfer Power
American Service Drop Cable 0.6/1kv Urd Cable for Transfer Power image
Get Latest Price Request a quote
Quick Details
Product Details
Aluminium Conductors. Polythylene or Crosslinked Polyethylene Insulation.
ABC Cables Applications:
Used to supply 3 phase power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75° C for polyethylene insulated conductors or 90° C for crosslinked polyethylene (XLP) insulated conductors.
ABC Cables Construction:
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR. One conductor is manufactured with an extruded ridge for phase identification.
ABC Cables Standards:
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
ABC Cables Using Properties
1. Rated Voltage: 0.6/1kV
2. Cable installation temperature not less than -20° C
3. Max. Temperature of cable at short circuit(The max. Duration does not exceed 5 minutes)
For XLPE insulation is 250° C.
For HDPE insulation is 150 ° C.
4. The Max. Bending radius of cable shall not be less than 20Dmm(D overall diameter of cable)
Type of ABC Cable
1. Duplex Service Drop: To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.
2. Triplex Service Drop: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.
3. Quadruplex Service Drop: Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
We are China American Service Drop Cable 0.6/1kv Urd Cable for Transfer Power manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 0.6kv/1kv Products
Popular huatongcable Products
65mn High Carbon Cold Drawn Spring Steel Wire
Power Cable/XLPE Insulation PVC Jacket Amoured Power Cable 4*150mm2
IEC 60227 Copper Conductor PVC Insulation Electric Wire RV 2.5mm2
Overhead Triplex Service Drop Calma Aerial Bundled Cable for Transmission Line
Overhead Quadruplex Service Drop Standardbred Aerial Bundled Cable for Transmission Line
Popular Service Drop Cable Products
Low Voltage ABC Aerial Bundled Cable (JKLYJ)
Service Drop Cable Areal Bundle Aluminum Cable ABC Aluminum Cable
Duplex Service Drop Cables (ABC CABLES)
Service Drop ABC Cable (Duplex / Triplex / Quadruplex)
Secondary Urd Quadruplex 600V Aluminum Conductor XLPE Insulation
Popular Urd Cable Products
600V Single Conductor Urd Cable
600V Aluminum Service Drop Secondary Cable Distribution Triplex /Duplex/Quadruplex Ud/Urd Cable
ASTM Standard Urd Cable PE/XLPE Insulation
Copper Conductor Power Cable XLPE Insulated Mv Cable
Quadruplex PVC Drop Urd Power XLPE Electric Aluminum ABC Cable
20kv Underground Distribution Line Aerial Primary Secondary Cable
Tags: 0.6kv/1kv, huatongcable, Service Drop Cable, Urd Cable