ANSI Strain Insulators for Lines

China 
                        ANSI Strain Insulators for Lines
                      manufacture and supplier

ANSI Strain Insulators for Lines image

Get Latest Price Request a quote

Quick Details

ANSI Strain Insulators for Lines

Oei Power

Grey

ISO9001, IEC IEEE

160KN

Trough Type

High Voltage Power Transmission

A Type Insulator

Suspension Insulator

Composite Polymer

High-voltage, Low-voltage, High-temperature

OEIpower

Cartons Pallets Wooden Case

IEC IEEE

China Nanyang

854690000

Product Details

The Composite Insulators 

The Composite Insulators comply with the latest editions of and amendments to, the standards/specification listed below:
 
CSA                                CANADIAN STANDARDS ASSOCIATION
 
G164-4                       –      Hot dip galvanizing of Irregular Shaped Articles
 
CAN/CSA                 –      Quality Assurance Program Categories 2299.3
 
ANSI                          –     AMERICAN NATIONAL STANDARDS INSTITUTE
 
C29.1                          –     American Standard Test Method For Electrical Power Insulators
 
C29.7                          –     American Standard For Wet-processed Porcelain Insulators (High Voltage Line Post Type) Electrical Power Insulators
 
987-1985                    –      IEEE Guide For Application of Composite Insulators
 
D750                           –     Recommended Practice for Operating Light and Weather Exposure Apparatus (Carbon Arc Type) For Artificial Weather Testing Of Rubber Compounds.
 
D1499                         –     Recommended Practice For Exposure of Plastics.
 
D2240                         –     Rubber Properties, Durometer Hardness
 
D2565                         –     Recommended Practice For Operating Xenon-Arc Light And Water Exposure Apparatus Plastics.
The weathershed of the Post Insulators shall be manufactured from either Hydrated Alumina Ethylene Propylene Copolymer (EPM) as the primary constituent or Silicone Elastomers. The weathershead shall be injection moulded and brought to final cure state in one continuous process to prevent internal undercure or surface overcure. Additionally, the weathershead shall provide hydrophobic surface, even after exposure to tropical marine environment, ultra violent rays and moisture.
Core

 
The rod or the core is manufactured from Fibreglass, having 70-75 by weight of auxiliary aligned glass fibre bonded by an organic resin. The rod is either be cast or pultruded.
The end fittings are have the following properties:
 

i.         are compressed onto the Fibreglass rod member
ii.        are  not move relative to the central Fibreglass rod at applied loads equal to two times the rated Routine Test Load or maximum designed cantilever loads
iii.       are attracted to the rod after completion of all external heat processes used to cure or bond component parts.
 
The insulator are  provided load limiting bases that will deform under longitudinal loading of more than 100% of the rated design cantilever load. 
Performance Characteristics
 
The Polymeric Insulators are meet the under listed performance characteristics.
 

 
           ITEM
 
              11kV
 
              33KV
 
Dry Flashover Withstand
 
              90kV     
 
              180kV
 
Wet flashover withstand
 
              70kV
 
              165kV
 
Positive Impulse Critical flashover
 
             145kV
 
               300kV
 
Maximum Radio Interference Voltage
 
Below 1micro volt
 
  Below 1 micro volt        
 
Design Tension Strength
 
              100kN
 
               100kN
 
Residual Strength after Power Arc
 
                80kN
 
                80kN
 
Mechanical Proof Test Load
 
               45kN
 
                 45kN
 
Maximum Sustained Load
 
               34kN
 
                 34kN
 
Design Torque Rating
 
              83 Nm
 
                 83 Nm

 
 

The insulator are suitable for accepting both aluminium and copper conductors having cross-sectional areas ranging from 35mm2 to 265mm2. The insulators are designed for mounting on the angle and channel crossarms specified in Specification E14
 
All exposed ferrous part shall be treated against corrosion. Treatment by hot dip galvanizing is preferable.
 
 

We are China ANSI Strain Insulators for Lines manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Composite Insulator Products

Epoxy Resin Contact Box Spout Bushing Insulator

Long Rod Composite Insulator Power Transmission

Fpq-20/12.5 Pin Type Composite Silicon Rubber Insulator for High Voltage

300kn Clevis and Tongue for Polymer Insulator / Suspension Insulator

High Voltage 400kn AC Composite Insulator

24kv 80kn Catenary Type Cantilever Suspension Composite Insulator

Popular jgtrade1 Products

Pcv Gloves with Long Sleeve Smooth/Sandy Finish Blue 60cm

Polymer Surge Arrester Flat Head

Electrical Tape 600V

Hgw9 Series 11kv Hv Outdoor High Voltage Disconnect Switch

Medium and Low Voltage Electric Wire Cable Single Core Copper Conductor Aluminum 3 Core PVC Insulated Power Cable 0.6/1 - 11kv

Polyester Lined Glove Coated with PU (gray)

Popular Polymer Insulator Products

Silicone Rubber Insulator for High Voltage Overhead Transmission Line

252kv silicone rubber station post insulator

11kv 24kv 33kv Composite Pin Insulators for Transmission Line

Fpq-20/5t 16-20 Composite Pin Type Insulator for Power Transmission

122kv Composite Line Post Insulator Polymeric Silicon Polymer Synthetic 11kv 22kv 33kv 66kv 72.5kv 110kv 132kv 10kn 70kn 120kn Tension Strain Long Rod Pin

Hv Stay Insulator

Popular Silicone Rubber Insulator Products

500kv polymer station post insulator

Cable Fault Tester

126-363kv Anti-Pollution Sol1d-Core Post Porcelain Insulator

66kv polymer station post insulator

24kv composite station post insulator

Jla-3 Special Grounding Wire for Power Plant

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION