ASTM 0.6/1kv XLPE Insulated Overhead Power Cable ACSR AAAC Service Drop Wire Duplex Triplex Quadruplex Aerial Bounded Aluminum Electric Wire ABC Cable
ASTM 0.6/1kv XLPE Insulated Overhead Power Cable ACSR AAAC Service Drop Wire Duplex Triplex Quadruplex Aerial Bounded Aluminum Electric Wire ABC Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Aluminum Conductor PVC Insulated ABC Cable
Covered line Wire is used primarily for 600v overhead secondary distribution lines. It is not an electrically insulated conductor and is treated as bare conductor when installed.
*CONSTRUCTION:
The conductors are 1350-H19 Aluminum Wire ,6201-T81 Aluminum Alloy or ACSR conductors, concentrically stranded and covered for weather proofing with polyethylene, high density polyethylene(HDPE) or cross-linked polyethylene(XLPE).
ASTM B-230 – Aluminum Wire 1350-H19 for Electrical Purposes
ASTM B-231 – Concentric-Lay-Stranded Aluminum Conductors
ASTM B-232 – Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR)
ASTM B-399- Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors
ICEA S-61-402-: Thermoplastic-insulated Wire And Cable For The Transmission And Distribution Of Electrical Energy
ICEA S-66-524-XLPE Insulated Wire and Cable For the Transmission and Distribution of Electrical Energy
Product name: Iec Compact ABC conductor Cable
Voltage: U0/U=0.6/1KV
Technical data: 1. Maximum operating temperature 90 degrees.
2. Maximum short circuit temperature 250 degrees
Application field: 1. Areas where underground networks are expensive.
2. Electrification of rural areas
Road conductor type: 1. AAC: all aluminum bare wire.Bare conductor of ASC: aluminum strand.
2. AAAC: all aluminum alloy bare conductor.Bare conductor of AASC: aluminum alloy stranded wire.
3. ACSR: steel core aluminum wire
| Nominal cross section | Neutral core | Phase core | weight (kg/km) |
Allowable ampacity (A) | |||||
| AAC | LBS | AAC | Insulation thickness (mm) |
XLPE | PE | ||||
| NO | diameter (mm) |
NO | diameter (mm) |
||||||
| 1*6AWG+1*6AWG | 7 | 1.56 | 563 | 1 | 4.11 | 1.14 | 92 | 85 | 70 |
| 1*6AWG+1*6AWG | 7 | 1.56 | 563 | 7 | 1.56 | 1.14 | 94 | 85 | 70 |
| 1*4AWG+1*4AWG | 7 | 1.96 | 881 | 1 | 5.19 | 1.14 | 139 | 115 | 90 |
| 1*4AWG+1*4AWG | 7 | 1.96 | 881 | 7 | 1.96 | 1.14 | 141 | 115 | 90 |
| 1*2AWG+1*2AWG | 7 | 2.47 | 1350 | 7 | 2.47 | 1.14 | 216 | 150 | 120 |
| 1*1/0AWG+1*1/0AWG | 7 | 3.12 | 1990 | 19 | 1.89 | 1.52 | 347 | 205 | 160 |
Triplex Service Drop—Aluminum Conductor
Used to supply power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made.
|
AWG or kcmil
|
Bare Neutral Messenger
|
Phase Conductor
|
Weight kg/km
|
Allowable Ampacities(A)
|
|||||
|
AAC
|
Rated Strength lbs.
|
AAC
|
Insul. Thick. mm
|
XLPE
|
PE
|
||||
|
NO.
|
Dia.mm
|
NO.
|
Dia.mm
|
||||||
|
2*6AWG+1*6AWG
|
7
|
1.56
|
563
|
1
|
4.11
|
1.14
|
146
|
85
|
70
|
|
2*6AWG+1*6AWG
|
7
|
1.56
|
563
|
7
|
1.56
|
1.14
|
150
|
85
|
70
|
|
2*4AWG+1*4AWG
|
7
|
1.96
|
881
|
1
|
5.19
|
1.14
|
219
|
115
|
90
|
|
2*4AWG+1*4AWG
|
7
|
1.96
|
881
|
7
|
1.96
|
1.14
|
224
|
115
|
90
|
|
2*2AWG+1*2AWG
|
7
|
2.47
|
1350
|
7
|
2.47
|
1.14
|
338
|
150
|
120
|
|
2*1/0AWG+1*1/0AWG
|
7
|
3.12
|
1990
|
7
|
3.12
|
1.52
|
544
|
205
|
160
|
|
2*1/0AWG+1*1/0AWG
|
7
|
3.12
|
1990
|
19
|
1.89
|
1.52
|
545
|
205
|
160
|
|
2*2/0AWG+l*2/0AWG
|
7
|
3.5
|
2510
|
7
|
3.5
|
1.52
|
671
|
235
|
185
|
|
2*3/0AWG+l*3/0AWG
|
19
|
2.39
|
3310
|
19
|
2.39
|
1.52
|
830
|
275
|
215
|
|
2*4/0AWG+l*4/0AWG
|
19
|
3.25
|
4020
|
19
|
3.25
|
1.52
|
1476
|
315
|
245
|
|
2*336.4+1*336.4
|
19
|
3.38
|
6146
|
19
|
3.38
|
2.03
|
1649
|
420
|
325
|
*APPLICATIONS:
Used to supply 3-phase power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made.
|
AWG or kcmil
|
Bare Neutral Messenger
|
Phase Conductor
|
Weight kg/km
|
Allowable Ampacities(A)
|
|||||
|
ACSR
|
Rated Strength lbs.
|
AAC
|
Insul. Thick. mm
|
XLPE
|
PE
|
||||
|
No.
|
Dia. mm
|
No.
|
Dia. mm
|
||||||
|
3*6AWG+1*6AWG
|
1,6
|
1.68
|
1190
|
1
|
4.11
|
1.14
|
221
|
75
|
60
|
|
3*6AWG+1*6AWG
|
1,6
|
1.68
|
1190
|
7
|
1.56
|
1.14
|
227
|
75
|
60
|
|
3*4AWG+1*4AWG
|
1,6
|
2.12
|
1860
|
1
|
5.19
|
1.14
|
331
|
100
|
80
|
|
3*4AWG+1*4AWG
|
1,6
|
2.12
|
1860
|
7
|
1.96
|
1.14
|
338
|
100
|
80
|
|
3*2AWG+1*2AWG
|
1,6
|
2.67
|
2850
|
7
|
2.47
|
1.14
|
511
|
135
|
105
|
|
3*1/0AWG+1*1/0AWG
|
1,6
|
3.37
|
4380
|
19
|
1.89
|
1.52
|
824
|
180
|
140
|
|
3*2/0AWG+l*2/0AWG
|
1,6
|
3.78
|
5310
|
19
|
2.13
|
1.52
|
1015
|
205
|
160
|
|
3*3/0AWG+l*3/0AWG
|
1,6
|
4.25
|
6620
|
19
|
2.39
|
1.52
|
1254
|
235
|
185
|
|
3*4/0AWG+l*4/0AWG
|
1,6
|
4.77
|
8350
|
19
|
2.68
|
1.52
|
1554
|
275
|
210
|
|
3*336.4+1*336.4
|
1,18
|
3.47
|
8680
|
19
|
3.38
|
2.03
|
2321
|
370
|
280
|
|
3*336.4+l*4/0AWG
|
1,6
|
4.77
|
8350
|
19
|
3.38
|
2.03
|
2221
|
370
|
280
|
Packing
Packing in wooden drums,steel wooden drums or as customer’s requirement.
Customer Visit
We have a professional sales team with each of them has engaged in this job for 3-10 years, so that we can provide the comprehensive and professional technology for you. With the perfect quality and after sales service, till now we have exported to more than 80 countries, welcome to visit us and establish win-win establish relationship!
Certificate
As first rank of the cable supplier in China, we have obtained CCC, ISO9001, ISO14001, OHSAS certificates, passed the SGS and BV test, and our brand "RMJT" be given China famous brand.
About us:
People’s Cable Group Co., Ltd. was founded in 2007, located in Zhengzhou Gongyi economic development zone. Our company has 2 factories (Zhitian factory and Zhulin factory), occupies total area of more than 300,000 square meters, with building area 230,000 square meters.
We are China ASTM 0.6/1kv XLPE Insulated Overhead Power Cable ACSR AAAC Service Drop Wire Duplex Triplex Quadruplex Aerial Bounded Aluminum Electric Wire ABC Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Overhead Cable Products
Overhead Cable Triplex Service Drop ABC Cable 600V for Overhead Transmission Lines
Quadruplex Service Drop / ACSR (ABC Cable)
Al XLPE Insulation Cable Aerial Bunch Cable for Overhead Distribution Lines
Aluminum Conductor ABC Power XLPE Insulated PVC Douplex Triple Overhead Aerial Bundle Cable
Triplex 2/0 AWG Overhead Cable with Neutral Messenger
Popular Power Cable Products
Flexible Cooper Core PVC Insulation Electrical Wire Cables 4mm 6mm
XLPE Insulation PVC Electric Armoured Power Cable
Concentric Neutral Cables Rated 5 Through 46kv
Low Voltage/Flame Redardant/Steel Wire Armored/PVC/XLPE Insulated Electrical Power Cable
Popular renmincable Products
Best Selling All Aluminium Alloy Conductor AAAC
2 Cores PVC Wire Cable--Manufacture BV/Bvr/BVVB/RV/Rvv Cable
Aerial Bounded Cable (ABC Cable) Duplex Service Drop-Aluminium Conductor
Bare Aluminum AAC ACSR AAAC Conductor for Overhead LV Mv Hv Transmission Line
300V Zr Rvs Electric Wire 2 Core 0.75mm 1.0mm 1.5mm 2.5mm 4mm Bare Twisted Copper Wire
Popular XLPE Cable Products
0.6/1kv XLPE or PE Insulated ABC Conductor 4X25mm2 2X25mm2
12kv 1 Core 3 Core Al/XLPE/PVC/Swa/PE (PVC) Underground Cables
Quadplex 4X185 XLPE Insulated Overhead Aerial Bundled Cable ABC Cable
XLPE 11kv Power Cable 240mm2 Power Cable
Electric Power XLPE Insulated Overhead Aluminum ABC Cable Supplier
Tags: Overhead Cable, Power Cable, renmincable, XLPE Cable