ASTM BS IEC Standard Customized Overhead Cable ACSR AAAC Conductor
ASTM BS IEC Standard Customized Overhead Cable ACSR AAAC Conductor image
Get Latest Price Request a quote
Quick Details
Product Details
Simple structure / Easy installation and maintenance / Low circuit cost / Large transmission capacity / Good conductive performance / Sufficient mechanical strength / High tensile strength
ACSR Cable Advantage:
1. Convenient for laying across special geographical conditions such as rivers and valleys
2.The tower distance can be enlarged
ACSR Cable Application:
Widely used in overhead power transmission lines of various voltage levels
AAAC Cable Applications
AAAC Aluminum Alloy Conductor is Used as bare overhead conductor for primary and secondary distribution. Designed utilizing a high-strength aluminum alloy to achieve a high strength-to-weight ratio; affords better sag characteristics. Aluminum alloy gives higher resistance to corrosion than ACSR.
Standard
BS EN50183,IEC 61089, ASTM B399,BS 3242, DIN 48204,GB/T1179-2008
Specification
Physical contents of aluminum alloy :-
1. Resistivity – 0.0326 Ohms mm2/m at 20°C
2. Density – 2.70 kgm/dm3 at 20°C
3. Coefficient of Linear Expansion – 23 x 10-6 / °C
4. Constant Mass Temperature Coefficient (a) – 0.00360/ °C
5. Material – Heat treated Al. Mg. Si. Alloy
– Approximately 0.5% Mg & 0.5% Si
ASTM B399
| Code Name | Area | Size & Stranding of ACSR with Equal Diameter | No. & Diameter of wires | Overall Diameter | Weight | Nominal Breaking Load | ||
| Nominal | Actual | |||||||
| MCM | mm2 | AWG or MCM | Al/Steel | mm | mm | kg/km | kN | |
| Akron | 30.58 | 15.48 | 6 | 6/1 | 7/1.68 | 5.04 | 42.7 | 4.92 |
| Alton | 48.69 | 24.71 | 4 | 6/1 | 7/2.12 | 6.35 | 68.0 | 7.84 |
| Ames | 77.47 | 39.22 | 2 | 6/1 | 7/2.67 | 8.02 | 108 | 12.45 |
| Azusa | 123.3 | 62.38 | 1/0 | 6/1 | 7/3.37 | 10.11 | 172 | 18.97 |
| Anaheim | 155.4 | 78.65 | 2/0 | 6/1 | 7/3.78 | 11.35 | 217 | 23.93 |
| Amherst | 195.7 | 99.22 | 3/0 | 6/1 | 7/4.25 | 12.75 | 273 | 30.18 |
| Alliance | 246.9 | 125.1 | 4/0 | 6/1 | 7/4.77 | 14.31 | 345 | 38.05 |
| Butte | 312.8 | 158.6 | 266.8 | 26/7 | 19/3.26 | 16.30 | 437 | 48.76 |
| Canton | 394.5 | 199.9 | 336.4 | 26/7 | 19/3.66 | 18.30 | 551 | 58.91 |
| Cairo | 465.4 | 235.8 | 397.5 | 26/7 | 19/3.98 | 19.88 | 650 | 69.48 |
| Darien | 559.5 | 283.5 | 477.0 | 26/7 | 19/4.36 | 21.79 | 781 | 83.52 |
| Elgin | 652.4 | 330.6 | 556.5 | 26/7 | 19/4.71 | 23.54 | 911 | 97.42 |
| Flint | 740.8 | 375.3 | 636.0 | 26/7 | 37/3.59 | 25.16 | 1035 | 108.21 |
| Greely | 927.2 | 469.8 | 795.0 | 26/7 | 37/4.02 | 28.14 | 1295 | 135.47 |
IEC 61089
| Code Number | A2 Conductor | A3 Conductor | Max.D.C. Resistance of Conductor at 20ºC | ||||||||
| Number of Wires | Diameter of Wires | Diameter of Conductor | Approx. Weight | Rated Strength | Number of Wires | Diameter of Wires | Diameter of Conductor | Approx. Weight | Rated Strength | ||
| mm² | – | mm | mm | kg/km | daN | – | mm | mm | kg/km | daN | Ω/km |
| 16 | 7 | 1.83 | 5.49 | 50.4 | 5.43 | 7 | 1.84 | 5.52 | 50.8 | 6.04 | 1.7896 |
| 25 | 7 | 2.29 | 6.87 | 78.7 | 8.49 | 7 | 2.30 | 6.9 | 79.5 | 9.44 | 1.1453 |
| 40 | 7 | 2.89 | 8.67 | 125.9 | 13.58 | 7 | 2.91 | 8.73 | 127.1 | 15.1 | 0.7158 |
| 63 | 7 | 3.63 | 10.8 | 198.3 | 21.39 | 7 | 3.65 | 10.95 | 200.2 | 23.06 | 0.4545 |
| 100 | 19 | 2.78 | 13.9 | 316.3 | 33.95 | 19 | 2.79 | 13.95 | 319.3 | 37.76 | 0.2877 |
| 125 | 19 | 3.10 | 15.5 | 395.4 | 42.44 | 19 | 3.12 | 15.6 | 399.2 | 47.20 | 0.2302 |
| 160 | 19 | 3.51 | 17.55 | 506.1 | 54.32 | 19 | 3.53 | 17.65 | 511.0 | 58.56 | 0.1798 |
| 200 | 19 | 3.93 | 19.65 | 623.7 | 67.91 | 19 | 3.95 | 19.75 | 638.7 | 73.20 | 0.1439 |
| 250 | 19 | 4.39 | 21.95 | 790.8 | 84.68 | 19 | 4.41 | 22.05 | 798.4 | 91.50 | 0.1151 |
| 315 | 37 | 3.53 | 24.71 | 998.9 | 106.95 | 37 | 3.55 | 24.85 | 1008.4 | 115.29 | 0.0916 |
| 400 | 37 | 3.98 | 27.86 | 1268.4 | 135.81 | 37 | 4.0 | 28 | 1280.5 | 146.4o | 0.0721 |
| 450 | 37 | 4.22 | 29.54 | 1426.9 | 152.79 | 37 | 4.24 | 29.68 | 1440.5 | 164.70 | 0.0641 |
| 500 | 37 | 4.45 | 31.15 | 1585.5 | 169.76 | 37 | 4.47 | 31.29 | 1600.6 | 183.oo | 0.0577 |
| 560 | 61 | 3.67 | 33.03 | 1778.4 | 190.14 | 61 | 3.69 | 33.21 | 1795.3 | 204.95 | 0.0516 |
| 630 | 61 | 3.89 | 35.01 | 2000.7 | 213.90 | 61 | 3.91 | 35.19 | 2019.8 | 230.58 | 0.0458 |
| 710 | 61 | 4.13 | 37.17 | 2254.8 | 241.07 | 61 | 4.15 | 37.35 | 2276.2 | 259.86 | 0.0407 |
| 800 | 61 | 4.38 | 39.42 | 2540.6 | 271.62 | 61 | 4.4 | 39.6 | 2564.8 | 282.80 | 0.0361 |
| 900 | 91 | 3.81 | 41.91 | 2861.1 | 305.58 | 91 | 3.83 | 42.13 | 2888.3 | 329.40 | 0.0321 |
| 1000 | 91 | 4.01 | 44.11 | 3179.0 | 339.53 | 91 | 4.03 | 44.33 | 3209.3 | 366.00 | 0.0289 |
| 1120 | 91 | 4.25 | 46.75 | 3560.5 | 380.27 | 91 | 4.27 | 46.97 | 3594.4 | 409.92 | 0 0258 |
| 1250 | 91 | 4.49 | 49.39 | 3973.7 | 424.41 | – | – | – | – | ||
BS EN50183
| Code Name | Calculated Cross Section |
No..Dia.of Wires | Overall Diameter | Weight | Rated Strength |
| mm² | No./mm | mm | kg/km | kN | |
| Box | 18.8 | 7/1.85 | 5.55 | 51.4 | 5.55 |
| Acacia | 23.8 | 7/2.08 | 6.24 | 64.9 | 7.02 |
| Almond | 30.1 | 7/2.34 | 7.02 | 82.2 | 8.88 |
| Cedar | 35.5 | 7/2.54 | 7.62 | 96.8 | 10.46 |
| Deodar | 42.2 | 7/2.77 | 8.31 | 115.2 | 12.44 |
| Fir | 47.8 | 7/2.95 | 8.85 | 130.6 | 14.11 |
| Hazel | 59.9 | 7/3.30 | 9.90 | 163.4 | 17.66 |
| Pine | 71.6 | 7/3.61 | 10.8 | 195.6 | 21.14 |
| Holly | 84.1 | 7/3.91 | 11.7 | 229.5 | 24.79 |
| Willow | 89.7 | 7/4.04 | 12.1 | 245,0 | 26.47 |
| Oak | 118.9 | 7/4.65 | 14.0 | 324.5 | 35.07 |
| Mulberry | 150.9 | 19/3.18 | 15.9 | 414.3 | 44.52 |
| Ash | 180.7 | 19/3.48 | 17.4 | 496.1 | 53.31 |
| Elm | 211.0 | 19/3.76 | 18.8 | 579.2 | 62.24 |
| Poplar | 239.4 | 37/2.87 | 20.1 | 659.4 | 70.61 |
| Sycamore | 303.2 | 37/3.23 | 22.6 | 835.2 | 89.40 |
| Upas | 362.1 | 37/3.53 | 24.7 | 997.5 | 106.82 |
| Yew | 479.0 | 37/4.06 | 28.4 | 1319.6 | 141.31 |
| Totara | 498.1 | 37/4.14 | 29.0 | 1372.1 | 146.93 |
| Rubus | 586.9 | 61/3.50 | 31.5 | 1622.0 | 173.13 |
| Sorbus | 659.4 | 61/3.71 | 33.4 | 1822.5 | 194.53 |
| Araucaria | 821.1 | 61/4.14 | 37.3 | 2269.4 | 242.24 |
| Redwood | 996.2 | 61/4.56 | 41.0 | 2753.2 | 293.88 |
Din 48201
| Code number | Calculated area | Number of wires | Diameter of wire | Overall diameter of conductor | Linear mass | Rated tensile strength | Max. DC resistance at 20ºC |
| mm2 | mm2 | mm | mm | kg/km | daN | Ω/km | |
| 16 | 15.89 | 7 | 1.70 | 5.1 | 43 | 444 | 2.0910 |
| 25 | 24.25 | 7 | 2.10 | 6.3 | 66 | 677 | 1.3703 |
| 35 | 34.36 | 7 | 2.50 | 7.5 | 94 | 960 | 0.9669 |
| 50 | 49.48 | 7 | 3.00 | 9.0 | 135 | 1382 | 0.6714 |
| 50 | 48.35 | 19 | 1.80 | 9.0 | 133 | 1350 | 0.6905 |
| 70 | 65.81 | 19 | 2.10 | 10.5 | 181 | 1838 | 0.5073 |
| 95 | 93.27 | 19 | 2.50 | 12.5 | 256 | 2605 | 0.3579 |
| 120 | 116.99 | 19 | 2.80 | 14.0 | 322 | 3268 | 0.2854 |
| 150 | 147.11 | 37 | 2.25 | 15.8 | 406 | 4109 | 0.2274 |
| 185 | 181.62 | 37 | 2.50 | 17.5 | 500 | 5073 | 0.1842 |
| 240 | 242.54 | 61 | 2.25 | 20.3 | 670 | 6774 | 0.1383 |
| 300 | 299.43 | 61 | 2.50 | 22.5 | 827 | 8363 | 0.1120 |
| 400 | 400.14 | 61 | 2.89 | 26.0 | 1104 | 11176 | 0.0838 |
| 500 | 499.63 | 61 | 3.23 | 29.1 | 1379 | 13960 | 0.06709 |
| 625 | 626.20 | 91 | 2.96 | 32.6 | 1732 | 17490 | 0.0540 |
| 800 | 802.09 | 91 | 3.35 | 36.9 | 2218 | 22402 | 0.0418 |
| 1000 | 999.71 | 91 | 3.74 | 41.1 | 2767 | 27922 | 0.0335 |
We are China ASTM BS IEC Standard Customized Overhead Cable ACSR AAAC Conductor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular AAAC Products
Factory Direct Selling ACSR / AAC /AAAC / ACSR Cable
All Aluminium Alloy Stranded Conductor/ Bare Conductor
AAAC. Aluminum Alloy Wire-Aster 117
Aluminum 1350-H19 Wires Concentrically Stranded AAC Conductors Manufactured to IEC61089
Australia Standard Metric Conductors AAAC AAC ACSR Aacsr Bare Conductor
Large-Span High-Voltage Transmission Line Corrosion Resistance AAAC Power Cable
Popular AAAC Conductor Products
AAAC Bare Conductor Overhead Transmission Cable AAAC
AAAC Bare Conductors Aerial Power Transmission Line AAAC Conductor
Bare Aluminum Alloy 6201-T81 Wire Strand AAAC Aasc Conductor Cable
Overhead Cable Aluminum Conductor ASTM B399 AAAC Conductor
High Voltage Overhead Line Aluminum Conductor Steel Core ACSR Conductor
Popular AAC Products
All Aluminum Stranded Conductor/ AAC Bare Conductor
Hard Drawn Bare or PVC XLPE Insulated Conductor
AAC All Aluminum Stranded Conductor
BS Standard AAC Cable/Conductor Size
Almelec Cable Flint 750mcm ASTM B399
ASTM All Aluminum Conductor Tulip AAC Bare Transmission Line
Popular wuhancable Products
Stranding Stainless Steel Tube Optical Opgw Cable Fiber Ground Wire
USA Sizes ASTM B232 Overhead Conductor Steel Reinforced ACSR Ruddy
Aluminum Conductor Steel Reinforced ACSR Rabbit Conductor
Rated Voltage 1-35kv Creep Resistance Aluminum Alloy Power Cable
Control Cable with PVC Insulation and PVC Sheath Braided Shielding (KVV, KVVP)
USA Sizes ASTM B232 Overhead Conductor Steel Reinforced ACSR Tanager
Tags: AAAC, AAAC Conductor, AAC, wuhancable