ASTM IEC BS Aluminum Clad Steel Reinforced All Aluminum Alloy Strand Electrical Wire AAC Overhead Conductor Bare Power Cable AAAC Conductor ACSR

China 
                        ASTM IEC BS Aluminum Clad Steel Reinforced All Aluminum Alloy Strand Electrical Wire AAC Overhead Conductor Bare Power Cable AAAC Conductor ACSR
                      manufacture and supplier

ASTM IEC BS Aluminum Clad Steel Reinforced All Aluminum Alloy Strand Electrical Wire AAC Overhead Conductor Bare Power Cable AAAC Conductor ACSR image

Get Latest Price Request a quote

Quick Details

ASTM IEC BS Aluminum Clad Steel Reinforced All Aluminum Alloy Strand Electrical Wire AAC Overhead Conductor Bare Power Cable AAAC Conductor ACSR

ACSR AAAC Conductor

Rmjt

ISO9001, CE, UL, CCC, RoHS, VDE, SGS BV

Overhead

Round Wire

Bare

Bare

Aluminum

Overhead, Heating

Stranded

Bare

Yes

More Than 30years

RMJT

Export Drum

25mm2 35mm2 50mm2 70mm2

Henan

761490000

Product Details

25mm2 35mm2 50mm2 70mm2 Bare Conductor Overhead Electrical Wire Aluminum Alloy Strand Power Cable ACSR Dog AAAC AAC Conductor

Applications
AAAC Aluminum Alloy Conductor is Used as bare overhead conductor for primary and secondary distribution. Designed utilizing a high-strength aluminum alloy to achieve a high strength-to-weight ratio; affords better sag characteristics. Aluminum alloy gives higher resistance to corrosion than ACSR.

Standard
 BS EN50183,IEC 61089, ASTM B399,BS 3242, DIN 48204,GB/T1179-2008

Specification
Physical contents of aluminum alloy :- 
1. Resistivity – 0.0326 Ohms mm2/m at 20°C 
2. Density – 2.70 kgm/dm3 at 20°C 
3. Coefficient of Linear Expansion – 23 x 10-6 / °C 
4. Constant Mass Temperature Coefficient (a) – 0.00360/ °C 
5. Material – Heat treated Al. Mg. Si. Alloy 
– Approximately 0.5% Mg & 0.5% Si 
 
ASTM B399

Code Name Area Size & Stranding of ACSR with Equal Diameter No. & Diameter of wires Overall Diameter Weight Nominal Breaking Load
Nominal Actual
MCM mm2 AWG or MCM Al/Steel mm mm kg/km kN
Akron 30.58 15.48 6 6/1 7/1.68 5.04 42.7 4.92
Alton 48.69 24.71 4 6/1 7/2.12 6.35 68.0 7.84
Ames 77.47 39.22 2 6/1 7/2.67 8.02 108 12.45
Azusa 123.3 62.38 1/0 6/1 7/3.37 10.11 172 18.97
Anaheim 155.4 78.65 2/0 6/1 7/3.78 11.35 217 23.93
Amherst 195.7 99.22 3/0 6/1 7/4.25 12.75 273 30.18
Alliance 246.9 125.1 4/0 6/1 7/4.77 14.31 345 38.05
Butte 312.8 158.6 266.8 26/7 19/3.26 16.30 437 48.76
Canton 394.5 199.9 336.4 26/7 19/3.66 18.30 551 58.91
Cairo 465.4 235.8 397.5 26/7 19/3.98 19.88 650 69.48
Darien 559.5 283.5 477.0 26/7 19/4.36 21.79 781 83.52
Elgin 652.4 330.6 556.5 26/7 19/4.71 23.54 911 97.42
Flint 740.8 375.3 636.0 26/7 37/3.59 25.16 1035 108.21
Greely 927.2 469.8 795.0 26/7 37/4.02 28.14 1295 135.47

 
IEC 61089

Code Number A2 Conductor A3 Conductor  Max.D.C. Resistance of Conductor at 20ºC
Number of Wires  Diameter of Wires Diameter of Conductor Approx. Weight Rated Strength Number of Wires  Diameter of Wires Diameter of Conductor Approx. Weight Rated Strength
mm² mm mm kg/km daN mm mm kg/km daN Ω/km
16 7 1.83 5.49 50.4 5.43 7 1.84 5.52 50.8 6.04 1.7896
25 7 2.29 6.87 78.7 8.49 7 2.30 6.9 79.5 9.44 1.1453
40 7 2.89 8.67 125.9 13.58 7 2.91 8.73 127.1 15.1 0.7158
63 7 3.63 10.8 198.3 21.39 7 3.65 10.95 200.2 23.06 0.4545
100 19 2.78 13.9 316.3 33.95 19 2.79 13.95 319.3 37.76 0.2877
125 19 3.10 15.5 395.4 42.44 19 3.12 15.6 399.2 47.20 0.2302
160 19 3.51 17.55 506.1 54.32 19 3.53 17.65 511.0 58.56 0.1798
200 19 3.93 19.65 623.7 67.91 19 3.95 19.75 638.7 73.20 0.1439
250 19 4.39 21.95 790.8 84.68 19 4.41 22.05 798.4 91.50 0.1151
315 37 3.53 24.71 998.9 106.95 37 3.55 24.85 1008.4 115.29 0.0916
400 37 3.98 27.86 1268.4 135.81 37 4.0 28 1280.5 146.4o 0.0721
450 37 4.22 29.54 1426.9 152.79 37 4.24 29.68 1440.5 164.70 0.0641
500 37 4.45 31.15 1585.5 169.76 37 4.47 31.29 1600.6 183.oo 0.0577
560 61 3.67 33.03 1778.4 190.14 61 3.69 33.21 1795.3 204.95 0.0516
630 61 3.89 35.01 2000.7 213.90 61 3.91 35.19 2019.8 230.58 0.0458
710 61 4.13 37.17 2254.8 241.07 61 4.15 37.35 2276.2 259.86 0.0407
800 61 4.38 39.42 2540.6 271.62 61 4.4 39.6 2564.8 282.80 0.0361
900 91 3.81 41.91 2861.1 305.58 91 3.83 42.13 2888.3 329.40 0.0321
1000 91 4.01 44.11 3179.0 339.53 91 4.03 44.33 3209.3 366.00 0.0289
1120 91 4.25 46.75 3560.5 380.27 91 4.27 46.97 3594.4 409.92 0 0258
1250 91 4.49 49.39 3973.7 424.41    

 
BS EN50183

Code Name  Calculated
Cross Section
No..Dia.of Wires  Overall Diameter Weight Rated Strength
  mm² No./mm mm kg/km kN
Box 18.8 7/1.85 5.55 51.4 5.55
Acacia 23.8 7/2.08 6.24 64.9 7.02
Almond 30.1 7/2.34 7.02 82.2 8.88
Cedar 35.5 7/2.54 7.62 96.8 10.46
Deodar 42.2 7/2.77 8.31 115.2 12.44
Fir 47.8 7/2.95 8.85 130.6 14.11
Hazel 59.9 7/3.30 9.90 163.4 17.66
Pine 71.6 7/3.61 10.8 195.6 21.14
Holly 84.1 7/3.91 11.7 229.5 24.79
Willow 89.7 7/4.04 12.1 245,0 26.47
Oak 118.9 7/4.65 14.0 324.5 35.07
Mulberry 150.9 19/3.18 15.9 414.3 44.52
Ash 180.7 19/3.48 17.4 496.1 53.31
Elm 211.0 19/3.76 18.8 579.2 62.24
Poplar 239.4 37/2.87 20.1 659.4 70.61
Sycamore 303.2 37/3.23 22.6 835.2 89.40
Upas 362.1 37/3.53 24.7 997.5 106.82
Yew 479.0 37/4.06 28.4 1319.6 141.31
Totara 498.1 37/4.14 29.0 1372.1 146.93
Rubus 586.9 61/3.50 31.5 1622.0 173.13
Sorbus 659.4 61/3.71 33.4 1822.5 194.53
Araucaria 821.1 61/4.14 37.3 2269.4 242.24
Redwood 996.2 61/4.56 41.0 2753.2 293.88

 
 
Din 48201

Code number Calculated area Number of wires Diameter of wire Overall diameter of conductor Linear mass Rated tensile strength Max. DC resistance at 20ºC
mm2 mm2   mm mm kg/km daN Ω/km
16 15.89 7 1.70 5.1 43 444 2.0910
25 24.25 7 2.10 6.3 66 677 1.3703
35 34.36 7 2.50 7.5 94 960 0.9669
50 49.48 7 3.00 9.0 135 1382 0.6714
50 48.35 19 1.80 9.0 133 1350 0.6905
70 65.81 19 2.10 10.5 181 1838 0.5073
95 93.27 19 2.50 12.5 256 2605 0.3579
120 116.99 19 2.80 14.0 322 3268 0.2854
150 147.11 37 2.25 15.8 406 4109 0.2274
185 181.62 37 2.50 17.5 500 5073 0.1842
240 242.54 61 2.25 20.3 670 6774 0.1383
300 299.43 61 2.50 22.5 827 8363 0.1120
400 400.14 61 2.89 26.0 1104 11176 0.0838
500 499.63 61 3.23 29.1 1379 13960 0.06709
625 626.20 91 2.96 32.6 1732 17490 0.0540
800 802.09 91 3.35 36.9 2218 22402 0.0418
1000 999.71 91 3.74 41.1 2767 27922 0.0335

 
Production process

Package
Package in Export Wooden or Steel Wooden or Steel Drums

About us
We were founded in 2007, located in Gongyi Henan,China. We have 2 factories (Headquarters Factory-produce insulated cables and Zhulin branch-produce bare conductors), occupies total area of more than 300,000 square meters, with building area 230,000 square meters.

Certificate
As first rank of the cable supplier in China, we have obtained CCC, ISO9001, ISO14001, OHSAS certificates, passed the SGS and BV test, and our brand "RMJT" be given China famous brand.

Customer Visit  
We have a professional sales team with each of them has engaged in this job for 3-10 years, so that we can provide the comprehensive and professional technology for you. With the perfect quality and after sales service, till now we have exported to more than 80 countries, welcome to visit us and establish win-win establish relationship!
 

We are China ASTM IEC BS Aluminum Clad Steel Reinforced All Aluminum Alloy Strand Electrical Wire AAC Overhead Conductor Bare Power Cable AAAC Conductor ACSR manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular ACSR Conductor Products

BS215 Standard Aluminum Conductor Steel Reinforced ACSR Dog Bare Conductor

Aluminum Conductor Steel Reinforced ACSR Conductor

954mcm Bare Aluminum Cable Conductor Rail of ASTM B232

Duck 605 Kcmil CSA C49 Aluminium Conductor Steel Reinforced ACSR

Mcm Standard ACSR Aluminum Clad Steel Reinforced Bare Conductor Wire

Bare Overhead ACSR Conductor Aluminium Conductor Steel Reinforced Conductor.

Popular Aluminum Conductor Products

ABC Wire1

Aluminum AAC AAAC Hard Drawn Standard Bare Steel Reinforced Overhead ACSR Conductor

Penguin Astmb232 4/0AWG Overhead Bare Aluminum ACSR Conductor Cable

Bare AAAC All Aluminum Alloy Conductor

All Aluminum Alloy Conductors /AAAC Conductors

Aluminum Conductor Steel Supported/Electrical Cable

Popular Bare Conductor Products

Aerial Raven Sparrow Drake Dog Wolf ACSR Conductor

ACSR Swan/Sparrow/Pigeon/Penguin Aluminium Conductor Steel Reinforced with ASTM

All Aluminium Alloy Bare Conductor Electric Wire AAAC

Aluminium Conductor Used for Power Transmission Lines

DIN Standard 19 Wires AAC, AAAC Bare Conductor

30/7/4.27mm BS Standard ACSR Deer Conductor for Power Transmission Line

Popular renmincable Products

26/35 Kv Copper/XLPE Underground Cable Amoured Cable Power Cable

Nayy Aluminium PVC Power Cable

0.6/1kv 3 Cores Flat Type Phase with 60% Coverage Copper Neutral Conductor XLPE Insulated PVC Outer Sheath Concentrico Cabre

Al/XLPE/Sta/PVC Armoured Power Cable Al Conductor XLPE Cable

ASTM B399 Aluminum Alloy Conductor Power Cable AAAC

Electrical Copper Power Cable Yjv22 0.6/1kv Armored Power Cable

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION