ASTM Standard 600V XLPE Insulated Urd Cable

China 
                        ASTM Standard 600V XLPE Insulated Urd Cable
                      manufacture and supplier

ASTM Standard 600V XLPE Insulated Urd Cable image

Get Latest Price Request a quote

Quick Details

ASTM Standard 600V XLPE Insulated Urd Cable

ABC Cable

Huatong

Jklv

ISO, CCC, CE, UL

Aluminium

Round Wire

None

PE

DC & AC

Low and Medium Voltage Cable

Construction, Overhead, Underground, Industrial, Power Station

PVC/PE/XLPE

40000m2

Black

HUATONG

Drum

GB/T 12527

China

8544492100

Product Details

Aluminium Service Drop
Aluminium Conductors. Polythylene or Crosslinked Polyethylene Insulation.

ABC Cables Applications:
Used to supply 3 phase power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75° C for polyethylene insulated conductors or 90° C for crosslinked polyethylene (XLP) insulated conductors.

ABC Cables Construction:
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR. One conductor is manufactured with an extruded ridge for phase identification.

ABC Cables Standards:
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.

ABC Cables Using Properties
1. Rated Voltage: 0.6/1kV
2. Cable installation temperature not less than -20° C
3. Max. Temperature of cable at short circuit(The max. Duration does not exceed 5 minutes)
For XLPE insulation is 250° C.
For HDPE insulation is 150 ° C.
4. The Max. Bending radius of cable shall not be less than 20Dmm(D overall diameter of cable)

Type of ABC Cable
1. Duplex Service Drop: To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.
2. Triplex Service Drop: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.
3. Quadruplex Service Drop: Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.

We are China ASTM Standard 600V XLPE Insulated Urd Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Cable Products

25mm 35mm 50mm Flux Types of Welding Cable

Mining Low Voltage Copper Conductor Flexible Rubber Cable

Copper/Aluminum Conductor 12/20kv (24KV) 33kv Overhead

Insulated PVC Shealthed Steel Tape Armored Power Cable

Fiber Optic/Optical Patch Cord LC/PC-SC/PC 6m 

Aluminum Concentric Neutral Cable XLPE Concentric Cable Coaxial Cable

Popular huatongcable Products

Overhead Line ACSR Aluminium Conductor Steel Reinforced ACSR Conductor

AAAC Conductor ASTM B399 Bare Aluminium Alloy 6201-T81 1/0AWG

Good Stability 33kv HDPE Modified Polyethylene Cable Spacer

Large Span Transmission Line Use ACSR Conductor

Aluminum Conductor Steel Reinforced ACSR Conductor

BS 3242 Aluminum Alloy Conductors for Overhead Power Transmission Hazel

Popular Overhead Cable Products

Aerial Bundle Cable Twisted ABC

WIRE QUADRUPLEX 2/0AWG Overhead cable Thoroughbred 6201 ALLOY NEUTRAL MESSENGER power cable

Mv 11kv Aluminum ABC Service Drop Overhead Electrical Cable PVC XLPE Insulated Duple Triplex Quadruplex Electrical ABC Cable

Triplex Service Drop ABC Cable ACSR Neutral Conductor

Aluminum Alloy Conductor Reinforced Overhead Aerial Bundle Concentrically&Nbsp; Stranded ACSR Wire

ASTM Standard Sparrow 2AWG Aluminum Conductor Steel Reinforced Conductor ACSR

Popular Urd Cable Products

Medium Voltage Aluminum Mv90 Single Core 15kv Urd Neutral 1/0 AWG Power Cable

15kv 133% 350 Kcmil Copper Tr-XLPE Insulated Copper Wire Sheild Urd Cable

Triplex Service Drop Aluminum Conductors ACSR Neutral-Messenger Voluta

5-46kv Utility Shielded Power Cable Icea S-97-682

UL1072 Certified15-35kv XLPE Insulated Aluminum Conductor Mv90/Mv105 Urd Cable

Triplex and Duplex 8000 Series Conductor Aluminum 600V Urd Cable