Bare Aluminum Conductor Overhead Cable AAC AAAC ACSR
Bare Aluminum Conductor Overhead Cable AAC AAAC ACSR image
Get Latest Price Request a quote
Quick Details
Product Details
Applications:
Conductor(AAC, AAAC and ACSR) have been widely used in power transmission lines with various voltage levels,because they have such good characteristics as simple structure,convenient installation and maintenance,low cost large transmission capacity.And they are also suitable for laying across rivers valleys and the places where special geographical features exist.
Material Standard:
1) The hard aluminum conductor used for AAC and ACSR conforms to the standard GB/T 17048-1997(equivalent to IEC 60889:1987).
2) The zinc coated steel wire used for ACSR conforms to IEC 60888:1987.
3) Production can be arranged according to customers requirements for material standard,etc.
Construction of All Aluminum Conductor and Aluminum Conductor Steel Reinforced
Standards:
ASTM-B232 Standard specification for Concentric-Lay-Stranded Aluminum 1350 Conductors
BS215-2 aluminum conductors steel-reinforced -For overhead power transmission
DIN48204 Steel reinforced aluminum stranded conductors
IEC209 Aluminum stranded conductor steel reinforced
Customized type available.
ACSR bare conductor meets/exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced
(ACSR)
B-341 Aluminum-Coated Steel Core Wire for Aluminum Conductors, Steel
Reinforced (ACSR/AZ)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced
(ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum
Conductors, Steel Reinforced (ACSR)
Technical characteristics
Standard GB/T 1179-2008
Area |
/ Pieces/Diameter |
Diameter | Max. resistance At 20ºC |
Calculation Force |
Weight |
mm2 | mm | mm | Ω/km | KN | kg/km |
10 | 7/1.35 | 4.05 | 2.8633 | 1.95 | 27.4 |
16 | 7/1.71 | 5.12 | 1.7896 | 3.04 | 43.8 |
25 | 7/2.13 | 6.40 | 1.1453 | 4.50 | 68.4 |
40 | 7/2.70 | 8.09 | 0.7158 | 6.80 | 109.4 |
63 | 7/3.39 | 10.2 | 0.4545 | 10.39 | 172.3 |
100 | 19/2.59 | 12.9 | 0.2877 | 17.00 | 274.8 |
125 | 19/2.89 | 14.5 | 0.2302 | 21.25 | 343.6 |
160 | 19/3.27 | 16.4 | 0.1798 | 26.40 | 439.8 |
200 | 19/3.66 | 18.3 | 0.1439 | 32.00 | 549.7 |
250 | 19/4.09 | 20.5 | 0.1151 | 40.00 | 687.1 |
315 | 37/3.29 | 23.0 | 0.0916 | 51.97 | 867.9 |
400 | 37/3.71 | 26.0 | 0.0721 | 64.00 | 1102.0 |
450 | 37/3.94 | 27.5 | 0.0641 | 72.00 | 1239.8 |
500 | 37/4.15 | 29.0 | 0.0577 | 80.00 | 1377.6 |
560 | 37/4.39 | 30.7 | 0.0515 | 89.60 | 1542.9 |
630 | 61/3.63 | 32.6 | 0.0458 | 100.80 | 1738.3 |
710 | 61/3.85 | 34.6 | 0.0407 | 113.60 | 1959.1 |
800 | 61/4.09 | 36.8 | 0.0361 | 128.00 | 2207.4 |
900 | 61/4.33 | 39.0 | 0.0321 | 144.00 | 2483.3 |
1000 | 61/4.57 | 41.1 | 0.0289 | 160.00 | 2759.2 |
1120 | 91/3.96 | 43.5 | 0.0258 | 179.20 | 3093.5 |
1250 | 91/4.18 | 46.0 | 0.0231 | 200.00 | 3452.6 |
1400 | 91/4.43 | 48.7 | 0.0207 | 224.00 | 3866.9 |
1500 | 91/4.58 | 50.4 | 0.0193 | 240.00 | 4143.1 |
AAC Standard: ASTM B231
Code Name |
Total Area | / Stranding and wire diameter mm |
Linear Mass kg/km |
Overall Diameter mm |
Nominal Breaking Load daN |
Max. D.C. Resistance at 20ºC ≤Ω/k |
|
AWG or MCM | mm2 | ||||||
Peachbell | 6 | 13.29 | 7/1.554 | 37 | 4.67 | 249 | 2.1692 |
Rose | 4 | 21.16 | 7/1.961 | 58 | 5.89 | 396 | 1.3624 |
Iris | 2 | 33.61 | 7/2.474 | 93 | 7.42 | 597 | 0.8577 |
Pansy | 1 | 42.39 | 7/2.776 | 117 | 8.33 | 732 | 0.6801 |
Poppy | 1/0 | 53.48 | 7/3.119 | 147 | 9.36 | 873 | 0.5390 |
Aster | 2/0 | 67.42 | 7/3.503 | 186 | 10.51 | 1100 | 0.4276 |
Phlox | 3/0 | 85.03 | 7/3.932 | 234 | 11.80 | 1347 | 0.3390 |
Oxlip | 4/0 | 107.23 | 7/4.417 | 296 | 13.26 | 1698 | 0.2688 |
Valerian | 250 | 126.71 | 19/2.931 | 349 | 14.57 | 2062 | 0.2275 |
Sneezewort | 250 | 126.71 | 7/4.80 | 349 | 14.4 | 2007 | 0.2275 |
Laurel | 266.8 | 135.16 | 19/3.01 | 373 | 15.05 | 2200 | 0.2133 |
Daisy | 266.8 | 135.16 | 7/4.96 | 373 | 14.9 | 2141 | 0.2133 |
Peony | 300 | 152.0 | 19/3.193 | 419 | 15.97 | 2403 | 0.1896 |
Tulip | 336.4 | 170.45 | 19/3.381 | 470 | 16.91 | 2695 | 0.1691 |
Daffodil | 350 | 177.35 | 19/3.447 | 489 | 17.24 | 2804 | 0.1625 |
Canna | 397.5 | 201.42 | 19/3.673 | 555 | 18.36 | 3184 | 0.1431 |
Goldentuft | 450 | 228 | 19/3.909 | 629 | 19.55 | 3499 | 0.1264 |
Syringa | 477 | 241.68 | 37/2.882 | 666 | 20.19 | 3849 | 0.1193 |
Cosmos | 477 | 241.68 | 19/4.023 | 666 | 20.12 | 3708 | 0.1193 |
Hyacinth | 500 | 253.35 | 37/2.951 | 698 | 20.65 | 4035 | 0.1138 |
Zinnia | 500 | 253.35 | 19/4.12 | 698 | 20.6 | 3888 | 0.1138 |
Dahlia | 556.5 | 282 | 19/4.346 | 777 | 21.73 | 4327 | 0.1022 |
Mistletoe | 556.5 | 282 | 37/3.114 | 777 | 21.79 | 4362 | 0.1022 |
Meadowsweet | 600 | 304 | 37/3.233 | 838 | 22.63 | 4703 | 0.0948 |
Orchid | 636 | 322.25 | 37/3.33 | 888 | 23.31 | 4985 | 0.0894 |
Heuchera | 650 | 329.35 | 37/3.366 | 908 | 23.56 | 5095 | 0.0875 |
Flag | 700 | 354.71 | 61/2.72 | 978 | 24.48 | 5146 | 0.0813 |
AAC Standard: ASTM B231
Code Name |
Total Area | / Stranding and wire diameter mm |
Overall Diameter mm |
Linear Mass kg/mass |
Nominal Breaking Load daN |
Max. D.C. Resistance at 20ºC ≤Ω/km |
|
AWG or MCM | mm2 | ||||||
Verbena | 700 | 354.71 | 37/3.493 | 24.45 | 978 | 5487 | 0.0813 |
Nasturtium | 715.5 | 362.58 | 61/2.75 | 24.76 | 1000 | 5874 | 0.0795 |
Violet | 715.5 | 362.58 | 37/3.533 | 24.74 | 1000 | 5609 | 0.0795 |
Cattail | 750 | 380 | 61/2.817 | 25.35 | 1048 | 5985 | 0.0759 |
Petunia | 750 | 380 | 37/3.617 | 25.32 | 1048 | 5875 | 0.0759 |
Lilac | 795 | 402.84 | 61/2.90 | 26.11 | 1111 | 6345 | 0.0715 |
Arbutus | 795 | 402.84 | 37/3.724 | 26.06 | 1111 | 6232 | 0.0715 |
Snapdragon | 900 | 456.06 | 61/3.086 | 27.78 | 1257 | 6978 | 0.0632 |
Cockscomb | 900 | 456.06 | 37/3.962 | 27.73 | 1257 | 6848 | 0.0632 |
Goldenrod | 954 | 483.42 | 61/3.177 | 28.6 | 1333 | 7896 | 0.0596 |
Magnolia | 954 | 483.42 | 37/4.079 | 28.55 | 1333 | 7258 | 0.0596 |
Camellia | 1000 | 506.71 | 61/3.251 | 29.36 | 1397 | 7753 | 0.0569 |
Hawkweed | 1000 | 506.71 | 37/4.176 | 29.23 | 1397 | 7608 | 0.0569 |
Larkspur | 1033.5 | 523.68 | 61/3.307 | 29.76 | 1444 | 8012 | 0.0550 |
Bluebell | 1033.5 | 523.68 | 37/4.244 | 29.72 | 1444 | 7863 | 0.0550 |
Marigold | 1113 | 563.93 | 61/3.432 | 30.89 | 1555 | 8628 | 0.0511 |
Hawthorn | 1192.5 | 604.26 | 61/3.551 | 31.05 | 1666 | 9245 | 0.0477 |
Narcissus | 1272 | 644.51 | 61/3.668 | 33.02 | 1777 | 9861 | 0.0477 |
Columbine | 1351.5 | 684.84 | 61/3.78 | 34.01 | 1888 | 10478 | 0.0421 |
Carnation | 1431 | 725.10 | 61/3.89 | 35.03 | 1999 | 10768 | 0.0398 |
Gladiolus | 1510.5 | 765.35 | 61/4.00 | 35.09 | 2110 | 11365 | 0.0376 |
Coreopsis | 1590 | 805.68 | 61/4.099 | 36.51 | 2221 | 11964 | 0.0358 |
Jessamine | 1750 | 886.71 | 61/4.302 | 38.72 | 2445 | 13168 | 0.0325 |
Cowslip | 2000 | 1013.42 | 91/3.76 | 41.40 | 2791 | 15300 | 0.0285 |
Lupine | 2500 | 1266.67 | 91/4.21 | 46.30 | 3524 | 18700 | 0.0230 |
Trillium | 3000 | 1520.13 | 127/3.90 | 50.75 | 4232 | 22500 | 0.0192 |
Bluebonnet | 3500 | 1773.50 | 127/4.21 | 54.80 | 4985 | 26200 | 0.0166 |
AAC Standard: BS215 Part 1
Nominal Alum Area mm2 |
Stranding and wire diameter mm |
Sectional Area mm2 |
Approx. Weight Kg/km |
Overall Diameter mm |
Max..D.C. Resistance At 20ºC ≤Ω/km |
Calculated breaking load da N |
Final Modulus Of Elasticity hbar |
Coefficient of Linear Expansion /ºC |
22 | 7/2.06 | 23.33 | 64 | 6.18 | 1.227 | 399 | 5900 | 23×10- |
25 | 3/3.35 | 26.40 | 73 | 7.2 | 1.081 | 411 | 5900 | 23×10- |
25 | 7/2.21 | 26.8 | 73 | 6.6 | 1.066 | 459 | 5900 | 23×10- |
30 | 3/3.66 | 31.6 | 86 | 7.9 | 0.9082 | 486 | 5900 | 23×10- |
35 | 7/2.59 | 37.0 | 101 | 7.8 | 0.7762 | 603 | 5900 | 23×10- |
40 | 7/2.79 | 42.8 | 117 | 8.4 | 0.6689 | 687 | 5900 | 23×10- |
50 | 7/3.10 | 52.83 | 145 | 9.30 | 0.5419 | 828 | 5900 | 23×10- |
60 | 7/3.40 | 63.55 | 174 | 10.20 | 0.4505 | 990 | 5900 | 23×10- |
70 | 7/3.66 | 73.7 | 202 | 11.0 | 0.3881 | 1134 | 5900 | 23×10- |
75 | 7/3.78 | 78.5 | 215 | 11.4 | 0.3644 | 1194 | 5900 | 23×10- |
80 | 7/3.91 | 84.1 | 230 | 11.7 | 0.3406 | 1278 | 5900 | 23×10- |
90 | 7/4.17 | 95.6 | 262 | 12.5 | 0.2994 | 1453 | 5900 | 23×10- |
100 | 7/4.39 | 106.0 | 290 | 13.17 | 0.2702 | 1600 | 5900 | 23×10- |
100 | 19/2.67 | 106.0 | 293 | 13.4 | 0.2704 | 1742 | 5600 | 23×10- |
125 | 7/4.90 | 132.0 | 361 | 14.7 | 0.2169 | 1944 | 5900 | 23×10- |
150 | 7/5.36 | 157.9 | 432 | 16.1 | 0.1818 | 2385 | 5900 | 23×10- |
150 | 19/3.25 | 157.9 | 434 | 16.25 | 0.1825 | 2570 | 5600 | 23×10- |
175 | 19/3.53 | 186 | 512 | 17.7 | 0.1547 | 2863 | 5600 | 23×10- |
200 | 19/3.78 | 213.2 | 587 | 18.9 | 0.1349 | 3240 | 5600 | 23×10- |
225 | 19/3.99 | 236.9 | 652 | 20.0 | 0.1211 | 3601 | 5600 | 23×10- |
250 | 19/4.22 | 265.7 | 731 | 21.10 | 0.1083 | 4040 | 5600 | 23×10- |
300 | 19/4.65 | 322.7 | 888 | 23.25 | 0.08916 | 4875 | 5600 | 23×10- |
350 | 37/5.00 | 373.2 | 1027 | 25.0 | 0.07711 | 5637 | 5600 | 23×10- |
350 | 19/3.58 | 373.3 | 1029 | 25.1 | 0.07741 | 5745 | 5600 | 23×10- |
400 | 37/5.36 | 428.5 | 1179 | 26.8 | 0.06710 | 6473 | 5600 | 23×10- |
400 | 37/3.78 | 415.2 | 1145 | 26.46 | 0.06944 | 6310 | 5600 | 23×10- |
450 | 37/4.09 | 486.9 | 1342 | 28.6 | 0.05931 | 7401 | 5600 | 23×10- |
500 | 37/4.27 | 529.5 | 1460 | 29.9 | 0.05441 | 7998 | 5600 | 23×10- |
600 | 37/4.65 | 628.6 | 1733 | 32.6 | 0.04588 | 9495 | 5600 | 23×10- |
750 | 37/5.23 | 794.6 | 2191 | 36.6 | 0.03627 | 12010 | 5600 | 23×10- |
We can make according to your specifications, customized LOGO, with your company name on the cable.
Factory Address:
Yichuan Electricity Industry zone, Luoyang City, Henan Province, China
Test Machine
extruding machine, cable-former, drawbench and so on.
Package
Wooden drum or 100m/roll
Customer
American, Australia, India, South Africa, South America…
Our Principles
1. Quality first, customer first, safety first
2. Better service, faster delivery
3. Equal and mutual benefit
4. Honest and professional
Why choose us?
1. Swift and professional response
2. Patient and trusty
3. Severe quality control system
4. On-time delivery
Contact
Cathy Shi
Department sale manager
International Trade Department
Luoyang Dayuan Cable Co., Ltd
=================================
Tel: +86-379-69991587
Mobile: + 86-15136243085
=================================
We are China Bare Aluminum Conductor Overhead Cable AAC AAAC ACSR manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular AAC Products
50mm2 DIN Standard AAC Conductor
AAC AAAC ACSR Acar All Aluminium Conductor Alloy Overhead Bare Conductor 95mm Price
AAC AAAC Aluminum Bare Conductor for Overhead Transmission
AAC All Aluminum Conductor Sheep (30/3.71+7/3.71)
ASTM B231stranding and Wire Diameter 61/4.099 AAC
ABC Cable 3X120mm2+1X70mm2 0.6/1kV Low Voltage Aerial Bundled Cable
Popular AAC Conductor Products
BS215 100mm2 AAC Wasp Conductor Aluminum Overhead Conductor
Duplex Service Drop AAAC 6201 Alloy Neutral Conductor Vizala
Aluminum Conductor Steel Reinforced ACSR 95/15 for Myanmar
AAC Wasp AAC Conductor Asc Transmission Cables
AAAC AAC ACSR Conductor (Aluminum Conductor Steel Reinforced)
Popular AAC Power Cable Products
High Quality AAC-All Aluminum Conductor IEC 61089
Overhead Transmission Line Aluminum Conductor AAC
High Quality AAC Conductor All Aluminium Conductor (DIN 48201)
Overhead Conductors AAC/ AAAC/ ACSR/ Acar/ Accc Bare Conductors
Bare All Aluminum Conductor AAC Cable
Bare Aluminum Conductor AAC or Asc Conductor Wasp
Popular dycable Products
BS Standard 0.6/1kv 2/3/4/5 Cores Twist Conductor XLPE Insulation Aerial Bundle Cable ABC Cable
High Quality TUV Approved PV Solar Cable Manufacturer
6mmm2 Solar PV1-F Cable Manufacturer Price
ACSR Aluminum Conductor Steel Reinforced ACSR 300/50 mm2 Cable
TUV Approved Tinned Copper Solar PV Cable 2.5mm2
TUV Approved Solar PV Cable 6mm2 10mm2 for Solar System
Tags: AAC, AAC Conductor, AAC Power Cable, dycable