Bare Conductor of AAAC Conductor All Aluminum Alloy Conductor with ISO Certificate
Bare Conductor of AAAC Conductor All Aluminum Alloy Conductor with ISO Certificate image
Get Latest Price Request a quote
Quick Details
Product Details
APPLICATION:
Used as bare overhead conductor for primary and secondary distribution. Designed for utilizing a high-strength aluminum-alloy to achieve a high strength-to-weight ratio; affords good sag characteristics.
1.AAAC conductors are extensively used for overhead distribution and transmission lines adjacent to ocean coastlines where there can be a problem of corrosion in the steel of an ACSR construction.
2. The aluminum alloy conductors are used in replace of singlelayer ACSR conductors to reduce power loss in overhead distribution and transmission lines,when replacing the aluminum conductor steel reinforced , the AAAC can save 5-8% of the construction cost.
3.AAAC referred to have higher strength but lower conductivity than pure aluminum.Being lighter, alloy conductors can sometimes be used to replace the conventional ACSR.
STANDARDS:
ASTM B399, BS EN50183 ,BS 3242,DIN 48201,IEC 61089
| All Aluminium Alloy Conductors(AAAC) ASTM B 399 | |||||||
| AREA | Stranding | Wire Dia. | Approx. overall diameter |
Weight | Nominal Breaking Load |
Nom. DC resistance at 20 Deg. |
|
| Nominal | Actual | ||||||
| AWGorMCM | (mm2) | (mm) | (mm) | (kg/km) | (kN) | (ohm/km) | |
| 6 | 13.3 | 7 | 1.554 | 4.67 | 37 | 4.22 | 2.5199 |
| 4 | 21.15 | 7 | 1.961 | 5.89 | 58 | 6.71 | 1.5824 |
| 2 | 33.63 | 7 | 2.474 | 7.42 | 93 | 10.68 | 0.9942 |
| 1/0 | 53.48 | 7 | 3.119 | 9.36 | 148 | 16.97 | 0.6256 |
| 2/0 | 67.42 | 7 | 3.503 | 10.51 | 186 | 20.52 | 0.4959 |
| 3/0 | 85.03 | 7 | 3.932 | 11.8 | 234 | 25.86 | 0.3936 |
| 4/0 | 107.23 | 7 | 4.417 | 13.26 | 296 | 32.63 | 0.3119 |
| 250 | 126.66 | 19 | 2.913 | 14.57 | 349 | 38.93 | 0.2642 |
| 300 | 152.1 | 19 | 3.193 | 15.97 | 419 | 46.77 | 0.2199 |
| 350 | 177.35 | 19 | 3.447 | 17.24 | 489 | 52.25 | 0.1887 |
| 400 | 202.71 | 19 | 3.686 | 18.43 | 559 | 59.74 | 0.1650 |
| 450 | 228 | 19 | 3.909 | 19.55 | 629 | 67.19 | 0.1467 |
| 500 | 253.35 | 19 | 4.12 | 20.6 | 698 | 74.64 | 0.1321 |
| 550 | 278.6 | 37 | 3.096 | 21.67 | 768 | 83.80 | 0.1202 |
| 600 | 303.8 | 37 | 3.233 | 22.63 | 838 | 91.38 | 0.1102 |
| 650 | 329.25 | 37 | 3.366 | 23.56 | 908 | 97.94 | 0.1016 |
| 700 | 354.55 | 37 | 3.493 | 24.45 | 978 | 102.20 | 0.0944 |
| 750 | 380.2 | 37 | 3.617 | 25.32 | 1049 | 109.60 | 0.0880 |
| 800 | 405.15 | 37 | 3.734 | 26.14 | 1117 | 116.80 | 0.0826 |
| 900 | 456.16 | 37 | 3.962 | 27.73 | 1258 | 131.50 | 0.0733 |
| 1000 | 506.71 | 37 | 4.176 | 29.23 | 1399 | 146.10 | 0.0660 |
| AAAC (Characteristics of A2 Conductors) IEC 61089 | |||||||
| Code number | Area | Number of wires |
Diameter | Linear mass |
Rated strength |
D.C resistance | |
| Wire | Cond | ||||||
| mm2 | mm | mm | kg/km | kN | Ohm/km | ||
| 16 | 18.4 | 7 | 1.83 | 5.49 | 50.4 | 5.43 | 1.7896 |
| 25 | 28.8 | 7 | 2.29 | 6.86 | 78.7 | 8.49 | 1.1453 |
| 40 | 46 | 7 | 2.89 | 8.68 | 125.9 | 13.58 | 0.7158 |
| 63 | 72.5 | 7 | 3.63 | 10.9 | 198.3 | 21.39 | 0.4545 |
| 100 | 115 | 19 | 2.7 | 13.9 | 316.3 | 33.95 | 0.2877 |
| 125 | 144 | 19 | 3.1 | 15.5 | 395.4 | 42.44 | 0.2302 |
| 160 | 184 | 19 | 3.51 | 17.6 | 506.1 | 54.32 | 0.1798 |
| 200 | 230 | 19 | 3.93 | 19.6 | 632.7 | 67.91 | 0.1439 |
| 250 | 288 | 19 | 4.39 | 22 | 790.8 | 84.88 | 0.1151 |
| 315 | 363 | 37 | 3.53 | 24.7 | 998.9 | 106.95 | 0.0916 |
| 400 | 460 | 37 | 3.98 | 27.9 | 1268.4 | 135.81 | 0.0721 |
| 450 | 518 | 37 | 4.22 | 29.6 | 1426.9 | 152.79 | 0.0641 |
| 500 | 575 | 37 | 4.45 | 31.2 | 1585.5 | 169.76 | 0.0577 |
| 560 | 645 | 61 | 3.67 | 33 | 1778.4 | 190.14 | 0.0516 |
| 630 | 725 | 61 | 3.89 | 35 | 2000.7 | 213.9 | 0.0458 |
| 710 | 817 | 61 | 4.13 | 37.2 | 2254.8 | 241.07 | 0.0407 |
| 800 | 921 | 61 | 4.38 | 39.5 | 2540.6 | 271.62 | 0.0361 |
| 900 | 1036 | 91 | 3.81 | 41.8 | 2861.1 | 305.68 | 0.0321 |
| 1000 | 1151 | 91 | 4.01 | 44.1 | 3179 | 339.53 | 0.0289 |
| 1120 | 1289 | 91 | 4.25 | 46.7 | 3560.5 | 380.27 | 0.0258 |
| 1250 | 1439 | 91 | 4.49 | 49.4 | 3973.7 | 424.41 | 0.0231 |
| All Aluminlum Alloy Conductors(AAAC) BS EN 50183 | |||||||
| Code Name | Area | No.of wires | Diameter | Mass per unit length |
Rated strength | DC resistance | |
| Wire | Cond. | ||||||
| mm2 | mm | mm | kg/km | kN | Ω/km | ||
| BOX | 18.8 | 7 | 1.85 | 5.55 | 51.4 | 5.55 | 1.7480 |
| ACACLA | 23.8 | 7 | 2.08 | 6.24 | 64.9 | 7.02 | 1.3828 |
| ALMOND | 30.1 | 7 | 2.34 | 7.02 | 82.2 | 8.88 | 1.0926 |
| CEDAR | 35.5 | 7 | 2.54 | 7.62 | 96.8 | 10.46 | 0.9273 |
| DEODAR | 42.2 | 7 | 2.77 | 8.31 | 115.2 | 12.44 | 0.7797 |
| FIR | 47.8 | 7 | 2.95 | 8.85 | 130.6 | 14.11 | 0.6875 |
| HAZEL | 59.9 | 7 | 3.3 | 9.90 | 163.4 | 17.66 | 0.5494 |
| PLNE | 71.6 | 7 | 3.61 | 10.8 | 195.6 | 21.14 | 0.4591 |
| HOLLY | 84.1 | 7 | 3.91 | 11.7 | 229.5 | 24.79 | 0.3913 |
| WILLOW | 89.7 | 7 | 4.04 | 12.1 | 245.0 | 26.47 | 0.3665 |
| OAK | 118.9 | 7 | 4.65 | 14.0 | 324.5 | 35.07 | 0.2767 |
| MULBERRY | 150.9 | 19 | 3.18 | 15.9 | 414.3 | 44.52 | 0.2192 |
| ASH | 180.7 | 19 | 3.48 | 17.4 | 496.1 | 53.31 | 0.1830 |
| ELM | 211 | 19 | 3.76 | 18.8 | 579.2 | 62.24 | 0.1568 |
| POPLAR | 239.4 | 37 | 2.87 | 20.1 | 659.4 | 70.61 | 0.1387 |
| SYCAMORE | 303.2 | 37 | 3.23 | 22.6 | 835.2 | 89.40 | 0.1095 |
| UPAS | 362.1 | 37 | 3.53 | 24.7 | 997.5 | 106.82 | 0.0917 |
| YEW | 479 | 37 | 4.06 | 28.4 | 1319.6 | 141.31 | 0.0693 |
| TOTARA | 498.1 | 37 | 4.14 | 29.0 | 1372.1 | 146.93 | 0.0666 |
| RUBUS | 586.9 | 61 | 3.5 | 31.5 | 1622.0 | 173.13 | 0.0567 |
| SORBUS | 659.4 | 61 | 3.71 | 33.4 | 1822.5 | 194.53 | 0.0505 |
| ARAUCARIA | 821.1 | 61 | 4.14 | 37.3 | 2269.4 | 242.24 | 0.0406 |
| REDWOOD | 996.2 | 61 | 4.56 | 41.0 | 2753.2 | 293.88 | 0.0334 |
| All Aluminium Alloy Conductors (AAAC) BS EN 50183 | |||||||
| Designation | Area | Stranding wire Dia. | Overall Diameter |
Nominal Breaking Load |
Nominal DC Resistance at 20ºC |
Standard Weight | |
| mm2 | No | Φ | mm | kN | Ohm/km | kg/km | |
| ASTER 22 | 22 | 7 | 2 | 6 | 7.15 | 1.4989 | 60 |
| ASTER 34.4 | 34.4 | 7 | 2.5 | 7.5 | 11.17 | 0.9593 | 93.8 |
| ASTER 54.6 | 54.6 | 7 | 3.15 | 9.45 | 17.73 | 0.6042 | 148.9 |
| ASTER 75.5 | 75.5 | 19 | 2.25 | 11.3 | 24.55 | 0.4388 | 207.4 |
| ASTER 117 | 117 | 19 | 2.8 | 14 | 38.02 | 0.2833 | 321.2 |
| ASTER 148 | 148.1 | 19 | 3.15 | 15.8 | 48.12 | 0.2239 | 406.5 |
| ASTER 181.6 | 181.6 | 37 | 2.5 | 17.5 | 59.03 | 0.1831 | 500.3 |
| ASTER 228 | 227.8 | 37 | 2.8 | 19.6 | 74.04 | 0.146 | 627.6 |
| ASTER 288 | 288.3 | 37 | 3.15 | 22.1 | 93.71 | 0.1154 | 794.3 |
| ASTER 366 | 366.2 | 37 | 3.55 | 24.9 | 115.36 | 0.0908 | 1008.9 |
| ASTER 570 | 570.2 | 61 | 3.45 | 31.1 | 185.33 | 0.0585 | 1576 |
| ASTER 851 | 850.7 | 91 | 3.45 | 38 | 276.47 | 0.0394 | 2360.7 |
| ASTER 1144 | 1143.5 | 91 | 4 | 44 | 360.22 | 0.0293 | 3173.4 |
| ASTER 1600 | 1595.9 | 127 | 4 | 52 | 502.72 | 0.021 | 4427.5 |
| AAAC 6201- All Aluminium Alloy Conductor AS 1531 | |||||||
| Code Name | Strands/ Wire Diameter |
Overall Diameter (Approx) |
Calculated Equivalent Aluminium Area |
Sectional Area |
Approx. Mass |
Calculated Minimum Breaking Load |
D.C.Resistence at 20ºC |
| mm | mm | mm2 | mm2 | kg/km | kN | Ω/km | |
| Agate | 7/1.75 | 5.25 | 14.3 | 16.84 | 46 | 4.71 | 1.972 |
| Amethyst | 7/2.25 | 6.75 | 23.7 | 27.83 | 76 | 7.78 | 1.194 |
| Diamond | 7/2.50 | 7.50 | 29.3 | 34.36 | 94 | 9.64 | 0.967 |
| Dolomite | 7/2.75 | 8.25 | 35.4 | 41.58 | 114 | 11.6 | 0.799 |
| Emerald | 7/3.00 | 9.00 | 42.2 | 49.48 | 136 | 13.9 | 0.671 |
| Garnet | 7/3.75 | 11.3 | 65.8 | 77.28 | 211 | 21.7 | 0.43 |
| Jade | 7/4.50 | 13.5 | 94.8 | 111.3 | 304 | 31.2 | 0.298 |
| Jasper | 7/4.75 | 14.3 | 106 | 124.0 | 340 | 34.8 | 0.268 |
| Opal | 19/3.25 | 16.3 | 134 | 157.6 | 433 | 44.2 | 0.212 |
| Patronite | 19/3.50 | 17.5 | 155 | 182.80 | 502 | 51.3 | 0.183 |
| Pearl | 19/3.75 | 18.8 | 178 | 209.8 | 577 | 58.8 | 0.159 |
| Ruby | 37/3.00 | 21.0 | 221 | 261.60 | 720 | 73.5 | 0.128 |
| Ruthenium | 37/3.25 | 22.8 | 260 | 307.00 | 845 | 86.1 | 0.109 |
| Rutile | 19/4.75 | 23.8 | 285 | 336.7 | 925 | 94.4 | 0.09991 |
| Sapphire | 37/3.75 | 26.3 | 345 | 408.50 | 1125 | 115 | 0.0819 |
| Spinel | 61/3.25 | 29.3 | 427 | 506.10 | 1396 | 135 | 0.0662 |
| Tantalum | 61/3.50 | 31.5 | 495 | 586.90 | 1620 | 156 | 0.0572 |
| Topaz | 61/3.75 | 33.8 | 568 | 673.40 | 1858 | 179 | 0.0498 |
| Zircon | 91/4.50 | 49.5 | 1220 | 1447 | 3997 | 384 | 0.0232 |
We are China Bare Conductor of AAAC Conductor All Aluminum Alloy Conductor with ISO Certificate manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular AAAC Conductor Products
All Aluminum Alloy Overhead Cable 400mcm AAAC Bare Conductor
15/25/50mm2 All Aluminum Alloy Conductor AAAC Conductor
IEC Aluminum Conductor Power Transmission Line Electric Cable Overhead Cable Conductor AAC AAAC ACSR
Hard Drawn Standard Bare Steel Reinforced Overhead ACSR Conductor
Standard NFC 34-125 266.8mcm AAAC Butte Azuza Bare Conductor
Popular Aluminum Alloy Conductor Products
Butte 312.8mcm ASTM Standard AAAC All Aluminum Alloy Conductor
Hot Sale Bare Stranded Overhead Alloy Aluminum AAAC Cable
Large-Span High-Voltage Transmission Line Corrosion Resistance AAAC Power Cable
Aluminium Conductor AAAC 740.8mcm Overhead Transmission Line
Factory Supply AAAC Aluminum Wire with Best Price
German Sizes DIN48201 All Aluminum Alloy Condcutor AAAC 35mm2
Popular Conductor Products
Midge Ant Wasp Butterfly with Standard BS215.1
25mm2 PE Insulated ABC Cable (25mm2+25 mm2)
Common Construction of Overhead Bara Conductor
AAAC Bare Conductor 100mm2 7/4.26mm for Uganda 33kV Distribution Line
120mm2 DIN48201 Standard AAC Conductor
ACSR Conductor Dog with Bs 215 Standard
Popular renmincable Products
100mm2 ACSR Cable Aluminum Conductor Steel Reinforced
XLPE/PVC Insualted Electric Cable
1p 1.5mm 2.5mm LSZH IEC: 60331 BS6387 Copper PVC Insulated Sheathed Power Electrical Cable
ABC Cable 3+1 Core Quadruplex 2/0 1/0 AWG Service Drop Overhead Cable
Yjlv22 XLPE Insulated Steel Tap Armored Power Cable 0.6/1kv
Conductor 50mm2 AA HD Bare Hda Conductor
Tags: AAAC Conductor, Aluminum Alloy Conductor, Conductor, renmincable