Bare Conductor of AAAC Conductor All Aluminum
Bare Conductor of AAAC Conductor All Aluminum image
Get Latest Price Request a quote
Basic Info.
Product Description
APPLICATION:
Used as bare overhead conductor for primary and secondary distribution. Designed for utilizing a high-strength aluminum-alloy to achieve a high strength-to-weight ratio; affords good sag characteristics.
1.AAAC conductors are extensively used for overhead distribution and transmission lines adjacent to ocean coastlines where there can be a problem of corrosion in the steel of an ACSR construction.
2. The aluminum alloy conductors are used in replace of singlelayer ACSR conductors to reduce power loss in overhead distribution and transmission lines,when replacing the aluminum conductor steel reinforced , the AAAC can save 5-8% of the construction cost.
3.AAAC referred to have higher strength but lower conductivity than pure aluminum.Being lighter, alloy conductors can sometimes be used to replace the conventional ACSR.
STANDARDS:
ASTM B399, BS EN50183 ,BS 3242,DIN 48201,IEC 61089
| All Aluminium Alloy Conductors(AAAC) ASTM B 399 | |||||||
| AREA | Stranding | Wire Dia. | Approx. overall diameter |
Weight | Nominal Breaking Load |
Nom. DC resistance at 20 Deg. |
|
| Nominal | Actual | ||||||
| AWGorMCM | (mm2) | (mm) | (mm) | (kg/km) | (kN) | (ohm/km) | |
| 6 | 13.3 | 7 | 1.554 | 4.67 | 37 | 4.22 | 2.5199 |
| 4 | 21.15 | 7 | 1.961 | 5.89 | 58 | 6.71 | 1.5824 |
| 2 | 33.63 | 7 | 2.474 | 7.42 | 93 | 10.68 | 0.9942 |
| 1/0 | 53.48 | 7 | 3.119 | 9.36 | 148 | 16.97 | 0.6256 |
| 2/0 | 67.42 | 7 | 3.503 | 10.51 | 186 | 20.52 | 0.4959 |
| 3/0 | 85.03 | 7 | 3.932 | 11.8 | 234 | 25.86 | 0.3936 |
| 4/0 | 107.23 | 7 | 4.417 | 13.26 | 296 | 32.63 | 0.3119 |
| 250 | 126.66 | 19 | 2.913 | 14.57 | 349 | 38.93 | 0.2642 |
| 300 | 152.1 | 19 | 3.193 | 15.97 | 419 | 46.77 | 0.2199 |
| 350 | 177.35 | 19 | 3.447 | 17.24 | 489 | 52.25 | 0.1887 |
| 400 | 202.71 | 19 | 3.686 | 18.43 | 559 | 59.74 | 0.1650 |
| 450 | 228 | 19 | 3.909 | 19.55 | 629 | 67.19 | 0.1467 |
| 500 | 253.35 | 19 | 4.12 | 20.6 | 698 | 74.64 | 0.1321 |
| 550 | 278.6 | 37 | 3.096 | 21.67 | 768 | 83.80 | 0.1202 |
| 600 | 303.8 | 37 | 3.233 | 22.63 | 838 | 91.38 | 0.1102 |
| 650 | 329.25 | 37 | 3.366 | 23.56 | 908 | 97.94 | 0.1016 |
| 700 | 354.55 | 37 | 3.493 | 24.45 | 978 | 102.20 | 0.0944 |
| 750 | 380.2 | 37 | 3.617 | 25.32 | 1049 | 109.60 | 0.0880 |
| 800 | 405.15 | 37 | 3.734 | 26.14 | 1117 | 116.80 | 0.0826 |
| 900 | 456.16 | 37 | 3.962 | 27.73 | 1258 | 131.50 | 0.0733 |
| 1000 | 506.71 | 37 | 4.176 | 29.23 | 1399 | 146.10 | 0.0660 |
| AAAC (Characteristics of A2 Conductors) IEC 61089 | |||||||
| Code number | Area | Number of wires |
Diameter | Linear mass |
Rated strength |
D.C resistance | |
| Wire | Cond | ||||||
| mm2 | mm | mm | kg/km | kN | Ohm/km | ||
| 16 | 18.4 | 7 | 1.83 | 5.49 | 50.4 | 5.43 | 1.7896 |
| 25 | 28.8 | 7 | 2.29 | 6.86 | 78.7 | 8.49 | 1.1453 |
| 40 | 46 | 7 | 2.89 | 8.68 | 125.9 | 13.58 | 0.7158 |
| 63 | 72.5 | 7 | 3.63 | 10.9 | 198.3 | 21.39 | 0.4545 |
| 100 | 115 | 19 | 2.7 | 13.9 | 316.3 | 33.95 | 0.2877 |
| 125 | 144 | 19 | 3.1 | 15.5 | 395.4 | 42.44 | 0.2302 |
| 160 | 184 | 19 | 3.51 | 17.6 | 506.1 | 54.32 | 0.1798 |
| 200 | 230 | 19 | 3.93 | 19.6 | 632.7 | 67.91 | 0.1439 |
| 250 | 288 | 19 | 4.39 | 22 | 790.8 | 84.88 | 0.1151 |
| 315 | 363 | 37 | 3.53 | 24.7 | 998.9 | 106.95 | 0.0916 |
| 400 | 460 | 37 | 3.98 | 27.9 | 1268.4 | 135.81 | 0.0721 |
| 450 | 518 | 37 | 4.22 | 29.6 | 1426.9 | 152.79 | 0.0641 |
| 500 | 575 | 37 | 4.45 | 31.2 | 1585.5 | 169.76 | 0.0577 |
| 560 | 645 | 61 | 3.67 | 33 | 1778.4 | 190.14 | 0.0516 |
| 630 | 725 | 61 | 3.89 | 35 | 2000.7 | 213.9 | 0.0458 |
| 710 | 817 | 61 | 4.13 | 37.2 | 2254.8 | 241.07 | 0.0407 |
| 800 | 921 | 61 | 4.38 | 39.5 | 2540.6 | 271.62 | 0.0361 |
| 900 | 1036 | 91 | 3.81 | 41.8 | 2861.1 | 305.68 | 0.0321 |
| 1000 | 1151 | 91 | 4.01 | 44.1 | 3179 | 339.53 | 0.0289 |
| 1120 | 1289 | 91 | 4.25 | 46.7 | 3560.5 | 380.27 | 0.0258 |
| 1250 | 1439 | 91 | 4.49 | 49.4 | 3973.7 | 424.41 | 0.0231 |
| All Aluminlum Alloy Conductors(AAAC) BS EN 50183 | |||||||
| Code Name | Area | No.of wires | Diameter | Mass per unit length |
Rated strength | DC resistance | |
| Wire | Cond. | ||||||
| mm2 | mm | mm | kg/km | kN | Ω/km | ||
| BOX | 18.8 | 7 | 1.85 | 5.55 | 51.4 | 5.55 | 1.7480 |
| ACACLA | 23.8 | 7 | 2.08 | 6.24 | 64.9 | 7.02 | 1.3828 |
| ALMOND | 30.1 | 7 | 2.34 | 7.02 | 82.2 | 8.88 | 1.0926 |
| CEDAR | 35.5 | 7 | 2.54 | 7.62 | 96.8 | 10.46 | 0.9273 |
| DEODAR | 42.2 | 7 | 2.77 | 8.31 | 115.2 | 12.44 | 0.7797 |
| FIR | 47.8 | 7 | 2.95 | 8.85 | 130.6 | 14.11 | 0.6875 |
| HAZEL | 59.9 | 7 | 3.3 | 9.90 | 163.4 | 17.66 | 0.5494 |
| PLNE | 71.6 | 7 | 3.61 | 10.8 | 195.6 | 21.14 | 0.4591 |
| HOLLY | 84.1 | 7 | 3.91 | 11.7 | 229.5 | 24.79 | 0.3913 |
| WILLOW | 89.7 | 7 | 4.04 | 12.1 | 245.0 | 26.47 | 0.3665 |
| OAK | 118.9 | 7 | 4.65 | 14.0 | 324.5 | 35.07 | 0.2767 |
| MULBERRY | 150.9 | 19 | 3.18 | 15.9 | 414.3 | 44.52 | 0.2192 |
| ASH | 180.7 | 19 | 3.48 | 17.4 | 496.1 | 53.31 | 0.1830 |
| ELM | 211 | 19 | 3.76 | 18.8 | 579.2 | 62.24 | 0.1568 |
| POPLAR | 239.4 | 37 | 2.87 | 20.1 | 659.4 | 70.61 | 0.1387 |
| SYCAMORE | 303.2 | 37 | 3.23 | 22.6 | 835.2 | 89.40 | 0.1095 |
| UPAS | 362.1 | 37 | 3.53 | 24.7 | 997.5 | 106.82 | 0.0917 |
| YEW | 479 | 37 | 4.06 | 28.4 | 1319.6 | 141.31 | 0.0693 |
| TOTARA | 498.1 | 37 | 4.14 | 29.0 | 1372.1 | 146.93 | 0.0666 |
| RUBUS | 586.9 | 61 | 3.5 | 31.5 | 1622.0 | 173.13 | 0.0567 |
| SORBUS | 659.4 | 61 | 3.71 | 33.4 | 1822.5 | 194.53 | 0.0505 |
| ARAUCARIA | 821.1 | 61 | 4.14 | 37.3 | 2269.4 | 242.24 | 0.0406 |
| REDWOOD | 996.2 | 61 | 4.56 | 41.0 | 2753.2 | 293.88 | 0.0334 |
| All Aluminium Alloy Conductors (AAAC) BS EN 50183 | |||||||
| Designation | Area | Stranding wire Dia. | Overall Diameter |
Nominal Breaking Load |
Nominal DC Resistance at 20ºC |
Standard Weight | |
| mm2 | No | Φ | mm | kN | Ohm/km | kg/km | |
| ASTER 22 | 22 | 7 | 2 | 6 | 7.15 | 1.4989 | 60 |
| ASTER 34.4 | 34.4 | 7 | 2.5 | 7.5 | 11.17 | 0.9593 | 93.8 |
| ASTER 54.6 | 54.6 | 7 | 3.15 | 9.45 | 17.73 | 0.6042 | 148.9 |
| ASTER 75.5 | 75.5 | 19 | 2.25 | 11.3 | 24.55 | 0.4388 | 207.4 |
| ASTER 117 | 117 | 19 | 2.8 | 14 | 38.02 | 0.2833 | 321.2 |
| ASTER 148 | 148.1 | 19 | 3.15 | 15.8 | 48.12 | 0.2239 | 406.5 |
| ASTER 181.6 | 181.6 | 37 | 2.5 | 17.5 | 59.03 | 0.1831 | 500.3 |
| ASTER 228 | 227.8 | 37 | 2.8 | 19.6 | 74.04 | 0.146 | 627.6 |
| ASTER 288 | 288.3 | 37 | 3.15 | 22.1 | 93.71 | 0.1154 | 794.3 |
| ASTER 366 | 366.2 | 37 | 3.55 | 24.9 | 115.36 | 0.0908 | 1008.9 |
| ASTER 570 | 570.2 | 61 | 3.45 | 31.1 | 185.33 | 0.0585 | 1576 |
| ASTER 851 | 850.7 | 91 | 3.45 | 38 | 276.47 | 0.0394 | 2360.7 |
| ASTER 1144 | 1143.5 | 91 | 4 | 44 | 360.22 | 0.0293 | 3173.4 |
| ASTER 1600 | 1595.9 | 127 | 4 | 52 | 502.72 | 0.021 | 4427.5 |
| AAAC 6201- All Aluminium Alloy Conductor AS 1531 | |||||||
| Code Name | Strands/ Wire Diameter |
Overall Diameter (Approx) |
Calculated Equivalent Aluminium Area |
Sectional Area |
Approx. Mass |
Calculated Minimum Breaking Load |
D.C.Resistence at 20ºC |
| mm | mm | mm2 | mm2 | kg/km | kN | Ω/km | |
| Agate | 7/1.75 | 5.25 | 14.3 | 16.84 | 46 | 4.71 | 1.972 |
| Amethyst | 7/2.25 | 6.75 | 23.7 | 27.83 | 76 | 7.78 | 1.194 |
| Diamond | 7/2.50 | 7.50 | 29.3 | 34.36 | 94 | 9.64 | 0.967 |
| Dolomite | 7/2.75 | 8.25 | 35.4 | 41.58 | 114 | 11.6 | 0.799 |
| Emerald | 7/3.00 | 9.00 | 42.2 | 49.48 | 136 | 13.9 | 0.671 |
| Garnet | 7/3.75 | 11.3 | 65.8 | 77.28 | 211 | 21.7 | 0.43 |
| Jade | 7/4.50 | 13.5 | 94.8 | 111.3 | 304 | 31.2 | 0.298 |
| Jasper | 7/4.75 | 14.3 | 106 | 124.0 | 340 | 34.8 | 0.268 |
| Opal | 19/3.25 | 16.3 | 134 | 157.6 | 433 | 44.2 | 0.212 |
| Patronite | 19/3.50 | 17.5 | 155 | 182.80 | 502 | 51.3 | 0.183 |
| Pearl | 19/3.75 | 18.8 | 178 | 209.8 | 577 | 58.8 | 0.159 |
| Ruby | 37/3.00 | 21.0 | 221 | 261.60 | 720 | 73.5 | 0.128 |
| Ruthenium | 37/3.25 | 22.8 | 260 | 307.00 | 845 | 86.1 | 0.109 |
| Rutile | 19/4.75 | 23.8 | 285 | 336.7 | 925 | 94.4 | 0.09991 |
| Sapphire | 37/3.75 | 26.3 | 345 | 408.50 | 1125 | 115 | 0.0819 |
| Spinel | 61/3.25 | 29.3 | 427 | 506.10 | 1396 | 135 | 0.0662 |
| Tantalum | 61/3.50 | 31.5 | 495 | 586.90 | 1620 | 156 | 0.0572 |
| Topaz | 61/3.75 | 33.8 | 568 | 673.40 | 1858 | 179 | 0.0498 |
| Zircon | 91/4.50 | 49.5 | 1220 | 1447 | 3997 | 384 | 0.0232 |
We are China Bare Conductor of AAAC Conductor All Aluminum manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular AAAC Conductor Products
All Aluminium Alloy Conductor, AAAC Cable with BS, ASTM, DIN, IEC Standard
AAC AAAC ACSR Aacsr Acar Steel Wire Overhead Bare Conductor
ACSR Conductor Aluminum Conductor Steel Reinforced Overhead Bare Electric Cable Conductor
Electrical Cable Aluminium Alloy Conductor AAAC Conductor
AAAC Conductor ASTM B399 Bare Aluminium Alloy 6201 with Grease
ASTM/IEC/BS DIN Standard Greased AAAC Conductor Bare Conductor
Popular Aluminum Alloy Conductor Products
IEC61089 All Aluminum Alloy Condcutor AAAC 630
BS En50183 All Aluminium Alloy Conductor AAAC
Hot Sale (aluminum alloy conductor) AAAC Power Cable
German Sizes DIN48201 All Aluminum Alloy Condcutor AAAC 16mm2
All Aluminum Alloy Conductor Bare Almond AAAC Condcutor for Overhead Line
Popular Bare Conductor of AAAC Conductor All Aluminum Products
Popular renmincable Products
Flame Retardant 4 Core 4mm2 6mm2 10mm2 16mm2 Zr-Yjv Copper Electrical Cables XLPE Power Cable
Chinese Factory Price Power Cable Sta Swa Amoured Copper Cable Multi-Core Underground Cable
Bare Overhead Aluminum Conductor Alloy Reinforced Acar ASTM B524
Tags: AAAC Conductor, Aluminum Alloy Conductor, Bare Conductor of AAAC Conductor All Aluminum, renmincable