Bare Overhead Transmission Line Aluminum Conductor Alloy Reinforced ACSR Conductor
Bare Overhead Transmission Line Aluminum Conductor Alloy Reinforced ACSR Conductor image
Get Latest Price Request a quote
- Overview
- Product Description
- Company Profile
- Our Factory
- FAQ
Basic Info.
Packaging & Delivery
Product Description
AAC, AAAC, ACSR, ACAR conductor have been widely used in power transmission lines with various voltage levels, because they have such good characteristics as simple structure, convenient installation and maintenance, low cost large transmission capacity. And they are also suitable for laying across rivers and valleys where special geographical features exist.
1. Specification:
(1) all aluminium conductor (AAC)
(2) all aluminimum alloy conductor(AAAC)
(3) aluminum conductor steel reinforced (ACSR)
(4) anti-corrosion type ACSR
(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6)aluminimum conductor aluminimum alloy reinforced(ACAR)
2. Standard:
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power.
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
AAC(All aluminum conductor) are suited for overhead power line.
Construction:
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; “”aluminized”” aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease.
Specifications:
ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)
Notes:
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
Current ratings are based on 75º C conductor temperature, 25º C ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.
Code Name | Size (KCM) |
Strand | Approx.EC Cond withEquivalent Resistance |
Stranding | Diameter(in) | Cross Sectional Area (Sq in) |
Weight per 1000ft (lbs) |
Rated Strength (lbs) |
Resistance Ohms/1000ft (lbs) |
||
Individual Wires |
Complete Cable |
DC @ 20 o C | AC@ 75 o C | ||||||||
Akron | 30.58 | 7/w | 6 | 6/1 | .0661 | .198 | .0240 | 28.7 | 1,110 | .659 | .785 |
Alton | 48.69 | 7/w | 4 | 6/1 | .0834 | .250 | .0382 | 45.7 | 1,760 | .414 | .493 |
Ames | 77.47 | 7/w | 2 | 6/1 | .1052 | .316 | .0608 | 72.7 | 2,800 | .260 | .310 |
Azusa | 123.3 | 7/w | 1/0 | 6/1 | .1327 | .398 | .0968 | 115.7 | 4,460 | .163 | .195 |
Anaheim | 155.4 | 7/w | 2/0 | 6/1 | .1490 | .447 | .1221 | 145.9 | 5,390 | .130 | .154 |
Amherst | 195.7 | 7/w | 3/0 | 6/1 | .1672 | .502 | .1537 | 183.7 | 6,790 | .103 | .123 |
Alliance | 246.9 | 7/w | 4/0 | 6/1 | .1878 | .563 | .1939 | 231.8 | 8,560 | .0816 | .0973 |
Butte | 312.8 | 19/w | 266.8 | 26/7 | .1283 | .642 | .2456 | 293.6 | 11,000 | .0644 | .0769 |
Canton | 394.5 | 19/w | 336.4 | 26/7 | .1441 | .721 | .3098 | 370.3 | 13,300 | .0511 | .0610 |
Cairo | 465.4 | 19/w | 397.5 | 26/7 | .1565 | .783 | .3655 | 436.9 | 15,600 | .0433 | .0518 |
Darien | 559.5 | 19/w | 477.0 | 26/7 | .1716 | .858 | .4394 | 525.5 | 18,800 | .0360 | .0431 |
Elgin | 652.4 | 19/w | 556.5 | 26/7 | .1853 | .927 | .5124 | 612.4 | 21,900 | .0309 | .0371 |
Flint | 740.8 | 37/w | 636.0 | 26/7 | .1415 | .991 | .5818 | 695.5 | 24,400 | .0272 | .0327 |
Greely | 927.2 | 37/w | 795.0 | 26/7 | .1583 | 1.108 | .7282 | 870.4 | 30,500 | .0217 | .0263 |
Zhengzhou Jinshui Industry & Commerce Co.Ltd is located in the national class Zhengzhou high and new technology industries zone in Zhengzhou ,Henan province. We have owned a number of exclusive essential manufacture technologies and has pass ISO 9001 Quality Management Systerm ,ISO 14001 Environmental Management Systerm ,OHSAS18001 occupational Heath Management Systerm ,ISO 10012 Measurement Management Systerm and others from China and abroad.
We have been engaged in producing electric cable and wire for nearly 20 years, and we are also 12 year gold supplier. And we are confident that we can offer the best service and quality for you .
Our product range is as following:
*Bare conductors(AAC, AAAC, ACSR, Galvanized steel wire)
*Aerial Bounded Cable (Duplex, Triplex,Quadruplex)
* PVC insulated wire (Rated voltage to 450/750V)
*THHN/THWN wire
*PVC insulated Power Cable
*XLPE insulated Power Cable
*Rubber sheathed Cable
*Control Cable
*Welding Cable
*Cable AccessoriesWe take part in many fairs and exhibitions in China and abroad . Our aim is to be our customer’s factory in Zhengzhou ,China .
We are here to help you placing orders of cost-effective electric cable and keep tracking your products and shipment.
1,Professional production lines, experienced worker, ensure the production of every thing is fine and accurate.
2,We choose excellent raw materials carefully to ensure the quality and meet the need of customers.
3,Mechanical testing of Cables is done to determine the quality and mechanical characteristics before delivery.
1. Who are we?
2. How can we guarantee quality?
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
We are China Bare Overhead Transmission Line Aluminum Conductor Alloy Reinforced ACSR Conductor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Bare Conductor Products
High Current Carrying Capacity AAC Conductor Overhead Aluminium Conductor Cable Power Transmission
Aluminum Conductor Steel Reinforced ACSR Overhead Stranding Wire Custimized Size
All Aluminium Conductor / AAC Overhead Conductor
All Aluminium Conductor Wire Overhead Bare Conductors
Acss/Aw, Aluminium Conductors Steel Supported (ASTM B 856)
Popular Bare Overhead Transmission Line Aluminum Conductor Alloy Reinforced ACSR Conductor Products
Popular jsgroup Products
Wholesale Copper Conductor Flexible Electric Welding Cable for Welding Machine
450/750V 600/1000V Braided Shielding PVC Mechanical Control Cable
IEC/ASTM Multicore Control Copper Cable Uesd for Overhead Service Application
0.6/1-35kv XLPE Cable XLPE Insulated Power Cable
Nylon Flexible Multicore Wire 10AWG
XLPE Insulated Steel Tape Armoured/Sta Aluminum/Copper Core Electric Power Cable
Popular Overhead AAAC Conductor Products
Types of AAAC Conductors ACSR Bare Overhead Conductor
DIN Standard All Aluminum Alloy Overhead AAAC Conductor
Types of AAAC Conductors Bare Overhead Conductor
ASTM Stranded AAAC Overhead Conductor Electrical Wire Aluminum Cable Bare Conductor
Aluminum Alloy Overhead Power Cable Bare AAC ACSR AAAC Conductors
Aluminum Alloy Bare Conductor Overhead AAAC Conductor
Tags: Bare Conductor, Bare Overhead Transmission Line Aluminum Conductor Alloy Reinforced ACSR Conductor, jsgroup, Overhead AAAC Conductor