BS 3242 Willow All Aluminum Alloy Conductor AAAC Wire
BS 3242 Willow All Aluminum Alloy Conductor AAAC Wire image
Get Latest Price Request a quote
- Overview
- Product Description
- Certificates
- Packing
- International Fairs
Basic Info.
Product Description
Aerial Bundled Cables
Aluminium Conductor Cables
All Aluminum Alloy Conductor (AAAC) Cables
Application
AAAC is mainly used as bare overhead transmission cable and as primary and secondary distribution cable. It is
also suitable for laying across basins, rivers and valleys where special geographical teatures exist.
Standard
Basic design to BS 3242 / BS EN 50182 / IEC 61089 / ASTM B 399/B 399M / DIN 48201-6 standards
Construction
AAAC cable bvconsists of aluminum alloy wires. The aluminum alloy wires are concentrically stranded.
This section deals with heat-treatable magnesium silicon type aluminium alloys to the applicable International
Standard, the electrical and mechanical properties of which all fall within the values suggested by relevant
standard.
Conductors to all other recognized specifications can also be supplied. The alloys referred to have higher trength
but lower conductivity than pure aluminium.
Being lighter, alloy conductors can sometimes be used to advantage in place of the more conventional ACSR;
Having lower breaking loads than the later, their use becomes particularly favourable when ice and wind
loadings are low.
Electrical Properties
Density@20ºC | 2.70 kg/dm |
Temperature Coefficient@20°C | 0.00360 (°C) |
Resistivity@20°C | 0.0326 Ohms mm²/m |
Linear Expansivity | 23 x10-6(°C) |
Service Conditions
Ambient Temperature | -5°C – 50°C |
Wind Pressure | 80 – 130kg/m² |
Seismic Acceleration | 0.12 – 0.05g |
Isokeraunic Level | 10 – 18 |
Relative Humidity | 5 – 100% |
Construction Parameters
BS 3242
Code | AL Nominal Area | Cu Nominal Area Equivalent | Total Area | Stranding | Overall Diameter | Weight |
mm² | mm² | mm² | No.×mm | mm | kg/km | |
– | – | 6.45 | 11.7 | 7/1.47 | 4.41 | 32.2 |
Box | – | 9.68 | 18.8 | 7/1.85 | 5.55 | 51.7 |
Acacia | – | 12.9 | 21.9 | 7/2.08 | 6.24 | 66.1 |
Almond | 25 | 16.1 | 30.1 | 7/2.34 | 7.02 | 82.9 |
Ceda | 30 | 19.4 | 35.5 | 7/2.54 | 7.62 | 97.8 |
– | 40 | 22.6 | 42.2 | 7/2.77 | 8.31 | 116.4 |
Fir | 50 | 25.8 | 47.8 | 7/2.95 | 8.85 | 131.8 |
Hazel | 100 | 32.3 | 59.9 | 7/3.30 | 9.9 | 165 |
Pine | – | 38.7 | 71.7 | 7/3.61 | 10.83 | 197.7 |
– | – | 45.2 | 84.1 | 7/3.91 | 11.73 | 231.6 |
Willow | 150 | 48.4 | 89.8 | 7/4.04 | 12.12 | 247.5 |
– | 175 | 51.6 | 96.5 | 7/4.19 | 12.57 | 266.2 |
– | 300 | 58.1 | 108.8 | 7/4.45 | 13.35 | 299.8 |
Oak | – | 64.5 | 118.9 | 7/4.65 | 13.95 | 327.8 |
– | – | 80.6 | 118.8 | 19/2.82 | 14.1 | 327.6 |
Mulberry | – | 96.8 | 151.1 | 19/3.18 | 15.9 | 416.7 |
Ash | – | 113 | 180.7 | 19/3.48 | 17.4 | 498.1 |
Elm | – | 129 | 211 | 19/3.76 | 18.8 | 582.1 |
Poplar | – | 145 | 239 | 37/2.87 | 20.09 | 658.8 |
– | – | 161 | 270.8 | 37/3.05 | 21.35 | 746.7 |
Sycamore | – | 194 | 303 | 37/3.23 | 22.61 | 834.9 |
Upas | – | 226 | 362.1 | 37/3.53 | 24.71 | 998.6 |
– | – | 258 | 421.8 | 37/3.81 | 26.47 | 1163 |
Yew | – | – | 479.9 | 37/4.06 | 28.42 | 1323 |
(*) Note: The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.
BS EN 50182
Code | Stranding | Nominal Area | Overall Diameter | Weight | Rated Strength | Electrical Resistance | Current Rating* |
No.×mm | mm² | mm | kg/km | KN | Ω/Km | A | |
Box | 7/1.85 | 18.8 | 5.55 | 51.4 | 5.55 | 1.748 | 87 |
Acacia | 7/2.08 | 23.8 | 6.24 | 64.9 | 7.02 | 1.3828 | 101 |
Almond | 7/2.34 | 30.1 | 7.02 | 82.2 | 8.88 | 1.0926 | 116 |
Cedar | 7/2.54 | 35.5 | 7.62 | 96.8 | 10.46 | 0.9273 | 129 |
Deodar | 7/2.77 | 42.2 | 8.31 | 115.2 | 12.44 | 0.7797 | 143 |
Fir | 7/2.95 | 47.8 | 8.85 | 130.6 | 14.11 | 0.6875 | 155 |
Hazel | 7/3.30 | 59.9 | 9.9 | 163.4 | 17.66 | 0.5494 | 178 |
Pine | 7/3.61 | 71.6 | 10.83 | 195.6 | 21.14 | 0.4591 | 199 |
Holly | 7/3.91 | 84.1 | 11.73 | 229.5 | 24.79 | 0.3913 | 219 |
Willow | 7/4.04 | 89.7 | 12.12 | 245 | 26.47 | 0.3665 | 228 |
Oak | 7/4.65 | 118.9 | 13.95 | 324.5 | 35.07 | 0.2767 | 272 |
Mulberry | 19/3.18 | 150.9 | 15.9 | 414.3 | 44.52 | 0.2192 | 314 |
Ash | 19/3.48 | 180.7 | 17.4 | 496.1 | 53.31 | 0.183 | 351 |
Elm | 19/3.76 | 211 | 18.8 | 579.2 | 62.24 | 0.1568 | 386 |
Poplar | 37/2.87 | 239.4 | 20.09 | 659.4 | 70.61 | 0.1387 | 416 |
Sycamore | 37/3.23 | 303.2 | 22.61 | 835.2 | 89.4 | 0.1095 | 480 |
Upas | 37/3.53 | 362.1 | 24.71 | 997.5 | 106.82 | 0.0917 | 535 |
Yew | 37/4.06 | 479 | 28.42 | 1319.6 | 141.31 | 0.0693 | 633 |
Totara | 37/4.14 | 498.1 | 28.98 | 1372.1 | 146.93 | 0.0666 | 648 |
Rubus | 61/3.50 | 586.9 | 31.5 | 1622 | 173.13 | 0.0567 | 714 |
Sorbus | 61/3.71 | 659.4 | 33.39 | 1822.5 | 194.53 | 0.0505 | 764 |
Araucaria | 61/4.14 | 821.1 | 37.26 | 2269.4 | 242.24 | 0.0406 | 868 |
Redwood | 61/4.56 | 996.2 | 41.04 | 2753.2 | 293.88 | 0.0334 | 970 |
Note: *The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.
IEC 61089
Code | Nominal Area | Stranding | Overall Diameter | Weight | Rated Strength | Electrical Resistance | Current Rating* |
mm² | No.×mm | mm | kg/km | KN | Ω/Km | A | |
16 | 18.4 | 18.4 | 5.49 | 50.4 | 5.43 | 1.7896 | 86 |
25 | 28.8 | 28.8 | 6.87 | 78.7 | 8.49 | 1.1453 | 113 |
40 | 46 | 46 | 8.67 | 125.9 | 13.58 | 0.7158 | 151 |
63 | 72.5 | 72.5 | 10.89 | 198.3 | 21.39 | 0.4545 | 200 |
100 | 115 | 115 | 13.9 | 316.3 | 33.95 | 0.2877 | 266 |
125 | 144 | 144 | 15.5 | 395.4 | 42.44 | 0.2302 | 305 |
160 | 184 | 184 | 17.55 | 506.1 | 54.32 | 0.1798 | 355 |
200 | 230 | 230 | 19.65 | 632.7 | 67.91 | 0.1439 | 407 |
250 | 288 | 288 | 21.95 | 790.8 | 84.88 | 0.1151 | 466 |
315 | 363 | 363 | 24.71 | 998.9 | 106.95 | 0.0916 | 535 |
400 | 460 | 460 | 27.86 | 1268.4 | 135.81 | 0.0721 | 618 |
450 | 518 | 518 | 29.54 | 1426.9 | 152.79 | 0.0641 | 663 |
500 | 575 | 575 | 31.15 | 1585.5 | 169.76 | 0.0577 | 706 |
560 | 645 | 645 | 33.03 | 1778.4 | 190.14 | 0.0516 | 755 |
630 | 725 | 725 | 35.01 | 2000.7 | 213.9 | 0.0458 | 809 |
710 | 817 | 817 | 37.17 | 2254.8 | 241.07 | 0.0407 | 866 |
800 | 921 | 921 | 39.42 | 2540.6 | 271.62 | 0.0361 | 928 |
900* | 1036 | 1036 | 41.91 | 2861.1 | 305.58 | 0.0321 | 992 |
1000* | 1151 | 1151 | 44.11 | 3179 | 339.53 | 0.0289 | 1051 |
1120* | 1289 | 1289 | 46.75 | 3560.5 | 380.27 | 0.0258 | 1118 |
1250* | 1439 | 1439 | 49.39 | 3973.7 | 424.41 | 0.0231 | 1185 |
(*) Note: The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.
ASTM B 399/B 399M
Nominal Area | Stranding | Overall Diameter | Weight | Rated Strength | Electrical Resistance | Current Rating* | |
AWG&MCM | mm² | No.×mm | mm | kg/km | KN | Ω/Km | A |
6 | 13.2 | 7/1.55 | 4.65 | 36.2 | 4.18 | 2.5361 | 69 |
4 | 21.1 | 7/1.96 | 5.88 | 57.9 | 6.69 | 1.586 | 93 |
2 | 33.5 | 7/2.47 | 7.41 | 92 | 10.6 | 0.9987 | 123 |
0 | 53.5 | 7/3.12 | 9.36 | 146.8 | 17 | 0.62592 | 165 |
2/0 | 67.3 | 7/3.50 | 10.5 | 184.8 | 20.4 | 0.49738 | 190 |
3/0 | 84.9 | 7/3.93 | 11.79 | 233 | 25.7 | 0.3945 | 219 |
4/0 | 107 | 7/4.42 | 13.26 | 294.7 | 32.5 | 0.31188 | 253 |
250 | 126 | 19/2.91 | 14.55 | 346.7 | 38.8 | 0.26509 | 280 |
300 | 152 | 19/3.19 | 15.95 | 416.7 | 46.6 | 0.22059 | 313 |
350 | 178 | 19/3.45 | 17.25 | 487.3 | 52 | 0.1886 | 345 |
400 | 203 | 19/3.69 | 18.45 | 557.5 | 59.5 | 0.16486 | 375 |
450 | 228 | 19/3.91 | 19.55 | 626 | 66.8 | 0.14683 | 402 |
500 | 253 | 19/4.12 | 20.6 | 695 | 74.2 | 0.13224 | 429 |
550 | 279 | 37/3.10 | 21.7 | 766.2 | 83.9 | 0.11995 | 455 |
600 | 303 | 37/3.23 | 22.61 | 831.9 | 91 | 0.11049 | 478 |
650 | 330 | 37/3.37 | 23.59 | 905.5 | 94.9 | 0.1015 | 504 |
700 | 354 | 37/3.49 | 24.43 | 971.2 | 101 | 0.09464 | 525 |
750 | 381 | 37/3.62 | 25.34 | 1045 | 109 | 0.08796 | 549 |
800 | 404 | 37/3.73 | 26.11 | 1109 | 116 | 0.08285 | 569 |
900 | 456 | 37/3.96 | 27.72 | 1250 | 131 | 0.07351 | 612 |
1000 | 508 | 37/4.18 | 29.26 | 1393 | 146 | 0.06597 | 653 |
1250 | 631 | 61/3.63 | 32.67 | 1732 | 179 | 0.05306 | 743 |
1500 | 759 | 61/3.98 | 35.82 | 2082 | 215 | 0.04414 | 827 |
1750 | 886 | 61/4.30 | 38.7 | 2431 | 251 | 0.03781 | 904 |
(*) Note: The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.
DIN 48201 Part 6
Nominal Area | Stranding | Overall Diameter | Weight | Rated Strength | Electrical Resistance | Current Rating* | |
Nominal | Teorical | ||||||
mm² | mm² | No.×mm | mm | kg/km | KN | Ω/Km | A |
16 | 15.89 | 7/1.70 | 5.1 | 43 | 4.44 | 2.0742 | 78 |
25 | 24.25 | 7/2.10 | 6.3 | 66 | 6.77 | 1.3593 | 102 |
35 | 34.36 | 7/2.50 | 7.5 | 94 | 9.6 | 0.9591 | 126 |
50 | 49.48 | 7/3.00 | 9 | 135 | 13.82 | 0.666 | 158 |
50 | 48.35 | 19/1.80 | 9 | 133 | 13.5 | 0.6849 | 156 |
70 | 65.81 | 19/2.10 | 10.5 | 181 | 18.38 | 0.5032 | 189 |
95 | 93.27 | 19/2.50 | 12.5 | 256 | 26.05 | 0.3551 | 234 |
120 | 116.99 | 19/2.80 | 14 | 322 | 32.68 | 0.2831 | 269 |
150 | 147.11 | 37/2.25 | 15.8 | 406 | 41.09 | 0.2256 | 309 |
185 | 181.62 | 37/2.50 | 17.5 | 500 | 50.73 | 0.1828 | 352 |
240 | 242.54 | 61/2.25 | 20.3 | 670 | 67.74 | 0.1371 | 420 |
300 | 299.43 | 61/2.50 | 22.5 | 827 | 83.63 | 0.111 | 477 |
400 | 400.14 | 61/2.89 | 26 | 1104 | 111.76 | 0.0831 | 568 |
500 | 499.83 | 61/3.23 | 29.1 | 1379 | 139.6 | 0.0665 | 649 |
625* | 626.2 | 91/2.96 | 32.6 | 1732 | 174.9 | 0.0531 | 742 |
800* | 802.09 | 91/3.35 | 36.9 | 2218 | 224.02 | 0.0415 | 857 |
1000* | 999.71 | 91/3.74 | 41.1 | 2767 | 279.22 | 0.0333 | 971 |
* The items marked with "*" are not in our current product range and the details are for information only.
(*) Note: The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.
Technical Data
Code | AL Nominal Area | Maximum Resistance DC at 20º | Current Rating | ||
Temperate | Tropical | ||||
mm² | Ω / km | Ω / 1000ft | Amp | Amp | |
– | – | 2.87 | 0.873 | 90 | 73 |
Box | – | 1.79 | 0.544 | 121 | 98 |
Acacia | – | 1.4 | 0.426 | 140 | 114 |
Almond | 25 | 1.11 | 0.339 | 162 | 131 |
Ceda | 30 | 0.944 | 0.288 | 180 | 145 |
– | 40 | 0.794 | 0.242 | 200 | 162 |
Fir | 50 | 0.7 | 0.213 | 217 | 175 |
Hazel | 100 | 0.559 | 0.17 | 250 | 201 |
Pine | – | 0.467 | 0.142 | 279 | 224 |
– | – | 0.398 | 0.121 | 309 | 247 |
Willow | 150 | 0.373 | 0.114 | 322 | 258 |
– | 175 | 0.347 | 0.106 | 337 | 270 |
– | 300 | 0.308 | 0.0938 | 343 | 290 |
Oak | – | 0.282 | 0.0859 | 384 | 307 |
– | – | 0.282 | 0.086 | 385 | 307 |
Mulberry | – | 0.222 | 0.0676 | 448 | 356 |
Ash | – | 0.185 | 0.0565 | 501 | 398 |
Elm | – | 0.159 | 0.048 | 553 | 438 |
Poplar | – | 0.14 | 0.0427 | 598 | 473 |
– | – | 0.124 | 0.0337 | 647 | 511 |
Sycamore | – | 0.111 | 0.0377 | 694 | 547 |
Upas | – | 0.0925 | 0.0282 | 776 | 610 |
– | – | 0.0794 | 0.0242 | 854 | 669 |
Yew | – | 0.0698 | 0.0213 | 925 | 723 |
Why Choose Us
1. Strict quality control system, excellent quality with reasonable price.
2. Strong and professional R&D team to meet your specific needs.
3. Rapid delivery and feedback. Faster lead time than our competitors.
4. OEM service available based on offical & legal authorization.
5. Free sample is available.
6. Appointed shipping company is acceptable.
We are China BS 3242 Willow All Aluminum Alloy Conductor AAAC Wire manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 740.8mcm AAAC Flint Conductor Products
Araucaria BS En 50182 All Aluminum Alloy Conductor AAAC
Acacia BS En 50182 All Aluminum Alloy Conductor AAAC
BS En 50182 Upas All Aluminum Alloy Conductor AAAC Wire
BS En 50182 All Aluminum Alloy Conductor AAAC Wire
740.8 Mcm AAAC Flint Conductor
BS En 50182 Elm All Aluminum Alloy Conductor AAAC Wire
Popular All Aluminium Alloy Conductor AAAC Products
Araucaria BS En 50182 All Aluminum Alloy Conductor AAAC
BS En 50182 All Aluminum Alloy Conductor AAAC Wire
All Aluminum Conductor Basic Design to BS 215-1 Standards
Almond 25 mm2 Aluminum Alloy Conductor AAAC
Beetle BS En 50182 All Aluminum Conductor AAC
BS 215 All Aluminum Conductor AAC
Popular BS 3242 Willow All Aluminum Alloy Conductor AAAC Wire Products
Popular hnbfcable Products
BS215 Standard 25mm2 Overhead Steel Core Bare Cable Aluminum ACSR Gopher Conductor
BS Standard All Aluminium Stranded Conductor
Extra-Flexible Copper Conductor XLPE Insulation and Lsf Jacket Control Cable
ASTM Standard 250mcm Aluminum Alloy Conductor XLPE Insulation Xhhw Cable
0.6/1kv 4 Core 35mm XLPE/PE Insulation ABC Cable
Tags: 740.8mcm AAAC Flint Conductor, All Aluminium Alloy Conductor AAAC, BS 3242 Willow All Aluminum Alloy Conductor AAAC Wire, hnbfcable