BS 6724 LSZH Sheath 0.6/1kv LV Power Swa Armored Cable
BS 6724 LSZH Sheath 0.6/1kv LV Power Swa Armored Cable image
Get Latest Price Request a quote
Quick Details
Product Details
1. Overview
Low Voltage Power Cables, Aluminum and Copper conductors of voltage range:0.6/1.0 kV.
2. Cable Types
Copper Conductor Cables
Aluminium Conductor Cables
Thermoplastic/ PVC Insulated Cables
Thermoset/XLPE Insulated Cables
Armoured/ Non – Armoured Cables
Single core cables up to and including 1000 mm2
2 core cables up to and including 95 mm2
3, 4 core & 4 core with reduced neutral cables up to and including 500 mm2
3. Applicable Standards
IEC 60502 (Part 1)"PVC/ XLPE insulated cables" single core /multi-core BS 5467 for XLPE insulated Armoured cables
BS 7889 for XLPE insulated single core unarmoured cables
4. Cables Include:
4.1 BS 6724 SWA LSZH 0.6/1kV Cable
4.1.1 Cable construction
| Conductor | Class 2 stranded copper conductor according to BS EN 60228 |
| Insulation | XLPE (Cross-Linked Polyethylene) |
| Bedding | LSZH (Low Smoke Zero Halogen) Type LTS1 according to BS 7655 |
| Armour | SWA (Steel Wire Armour) |
| Sheath | LSZH (Low Smoke Zero Halogen) Type LTS1 according to BS 7655 |
4.1.2 Electrical Characteristics
Dimensions – BS6724 XLPE/LSZH/SWA/LSZH (Copper)
| No. of Cores | Nominal Cross Sectional Area | Nominal Thickness of Insulation | Nominal Overall Diameter mm | Nominal Weight | |
| mm² | mm | Under Armour | Overall | kg/km | |
| 2 | 1.5 | 0.6 | 7.3 | 12.1 | 302 |
| 2 | 2.5 | 0.7 | 8.5 | 13.6 | 346 |
| 2 | 4 | 0.7 | 9.4 | 14.7 | 410 |
| 2 | 6 | 0.7 | 10.5 | 15.9 | 499 |
| 2 | 10 | 0.7 | 12.3 | 18 | 648 |
| 2 | 16 | 0.7 | 14.3 | 20.4 | 978 |
| 2 | 25 | 0.9 | 14.7 | 20.4 | 1290 |
| 2 | 35 | 0.9 | 16.8 | 23.3 | 1500 |
| 2 | 50 | 1 | 19 | 25.8 | 1890 |
| 2 | 70 | 1.1 | 22 | 29 | 2450 |
| 2 | 95 | 1.1 | 25.1 | 33.1 | 3300 |
| 2 | 120 | 1.2 | 27.9 | 36.1 | 4020 |
| 2 | 150 | 1.4 | 30.9 | 39.3 | 4750 |
| 3 | 1,5 | 0.6 | 7.8 | 12.6 | 330 |
| 3 | 2.5 | 0.7 | 9.2 | 14.1 | 390 |
| 3 | 4 | 0.7 | 10 | 15.3 | 464 |
| 3 | 6 | 0.7 | 11.2 | 16.6 | 568 |
| 3 | 10 | 0.7 | 13.1 | 19.5 | 866 |
| 3 | 16 | 0.7 | 15.3 | 21.6 | 1152 |
| 3 | 25 | 0.9 | 18.9 | 23.6 | 1800 |
| 3 | 35 | 0.9 | 21.3 | 25.7 | 2230 |
| 3 | 50 | 1 | 21.7 | 28.5 | 2490 |
| 3 | 70 | 1.1 | 25.2 | 32.2 | 3290 |
| 3 | 95 | 1.1 | 28.8 | 37 | 4440 |
| 3 | 120 | 1.2 | 32 | 40.4 | 5470 |
| 3 | 150 | 1.4 | 35.9 | 45.5 | 6930 |
| 3 | 185 | 1.6 | 40 | 49.8 | 8350 |
| 3 | 240 | 1.7 | 44.9 | 55.1 | 10400 |
| 3 | 300 | 1.8 | 49.8 | 60.2 | 12600 |
| 3 | 400 | 2 | 55.8 | 66.6 | 14600 |
| 4 | 1.5 | 0.6 | 8.5 | 13.3 | 365 |
| 4 | 2.5 | 0.7 | 9.9 | 15 | 438 |
| 4 | 4 | 0.7 | 11 | 16.4 | 532 |
| 4 | 6 | 0.7 | 12.3 | 18.7 | 764 |
| 4 | 10 | 0.7 | 14.5 | 21.1 | 1013 |
| 4 | 16 | 0.7 | 17 | 23.4 | 1360 |
| 4 | 25 | 0.9 | 21 | 26.1 | 2160 |
| 4 | 35 | 0.9 | 23.6 | 28.6 | 2690 |
| 4 | 50 | 1 | 25 | 32 | 3130 |
| 4 | 70 | 1.1 | 29.5 | 37.7 | 4500 |
| 4 | 95 | 1.1 | 33.3 | 41.7 | 5600 |
| 4 | 120 | 1.2 | 37.5 | 47.1 | 7400 |
| 4 | 150 | 1.4 | 41.6 | 51.4 | 8780 |
| 4 | 185 | 1.6 | 46.4 | 56.6 | 10630 |
| 4 | 240 | 1.7 | 52.6 | 63 | 13390 |
| 4 | 300 | 1.8 | 58 | 68.8 | 16290 |
| 4 | 400 | 2 | 65.4 | 78.1 | 19800 |
| 5 | 1.5 | 0.6 | 9.7 | 14.3 | 410 |
| 5 | 2.5 | 0.7 | 11.7 | 16.1 | 470 |
| 5 | 4 | 0.7 | 13 | 17.8 | 710 |
| 5 | 6 | 0.7 | 14.5 | 20 | 876 |
| 5 | 10 | 0.7 | 17.2 | 22.9 | 1165 |
| 5 | 16 | 0.7 | 20 | 26.6 | 1742 |
| 5 | 25 | 0.9 | 24.7 | 31.5 | 2323 |
| 5 | 35 | 0.9 | 27.8 | 34.8 | 2932 |
| 5 | 50 | 1 | 32.4 | 40.4 | 4192 |
| 7 | 1.5 | 0.6 | 10.2 | 15.2 | 470 |
| 7 | 2.5 | 0.7 | 12.3 | 17.1 | 600 |
| 7 | 4 | 0.7 | 13.6 | 19.1 | 881 |
| 12 | 1.5 | 0.6 | 13.7 | 19.4 | 780 |
| 12 | 2.5 | 0.7 | 16.3 | 22.4 | 1000 |
| 19 | 1.5 | 0.6 | 16.2 | 22.2 | 1000 |
| 19 | 2.5 | 0.7 | 19.9 | 26.6 | 1540 |
| 27 | 1.5 | 0.6 | 20 | 26.7 | 1500 |
| 27 | 2.5 | 0.7 | 24 | 30.7 | 1950 |
| 37 | 1.5 | 0.6 | 22.3 | 29 | 1800 |
| 37 | 2.5 | 0.7 | 26.9 | 33.8 | 2350 |
Class 2 Stranded Conductors for Single Core and Multi-Core Cables
| Nominal Cross Sectional Area |
Minimum No. Of Wires In Conductor | Maximum Resistance of Conductor At 20ºC |
|||||
| mm² | Circular | Circular Compacted | Shaped | Annealed Copper Conductor | |||
| Cu | Al | Cu | Al | Cu | Al | Plain Wires ohms/km | |
| 1.5 | 7 | – | 6 | – | – | – | 12.1 |
| 2.5 | 7 | – | 6 | – | – | – | 7.41 |
| 4 | 7 | – | 6 | – | – | – | 4.61 |
| 6 | 7 | – | 6 | – | – | – | 3.08 |
| 10 | 7 | 7 | 6 | 6 | – | – | 1.83 |
| 16 | 7 | 7 | 6 | 6 | – | – | 1.15 |
| 25 | 7 | 7 | 6 | 6 | 6 | 6 | 0.727 |
| 35 | 7 | 7 | 6 | 6 | 6 | 6 | 0.524 |
| 50 | 19 | 19 | 6 | 6 | 6 | 6 | 0.387 |
| 70 | 19 | 19 | 12 | 12 | 12 | 12 | 0.268 |
| 95 | 19 | 19 | 15 | 15 | 15 | 15 | 0.193 |
| 120 | 37 | 37 | 18 | 15 | 18 | 15 | 0.153 |
| 150 | 37 | 37 | 18 | 15 | 18 | 15 | 0.124 |
| 185 | 37 | 37 | 30 | 30 | 30 | 30 | 0.0991 |
| 240 | 37 | 37 | 34 | 30 | 34 | 30 | 0.0754 |
4.2 BS 5467 SWA PVC 0.6/1kV Cable
4.2.1 Cable Construction:
| Conductor | Class 2 stranded copper conductor according to BS EN 60228 |
| Insulation | XLPE (Cross-Linked Polyethylene) |
| Bedding | PVC (Polyvinyl Chloride) |
| Armour | SWA (Steel Wire Armour) |
| Sheath | PVC (Polyvinyl Chloride) |
4.2.2 Electrical Characteristics
Dimensions – BS5467 XLPE/PVC/AWA/PVC (Copper)
| No. of Cores | Nominal Cross Sectional Area | Nominal Thickness of Insulation | Nominal Overall Diameter mm | Nominal Weight | |
| mm² | mm | Under Armour | Overall | kg/km | |
| 2 | 1.5 | 0.6 | 7.3 | 12.1 | 302 |
| 2 | 2.5 | 0.7 | 8.5 | 13.6 | 346 |
| 2 | 4 | 0.7 | 9.4 | 14.7 | 410 |
| 2 | 6 | 0.7 | 10.5 | 15.9 | 499 |
| 2 | 10 | 0.7 | 12.3 | 18 | 648 |
| 2 | 16 | 0.7 | 14.3 | 20.4 | 978 |
| 2 | 25 | 0.9 | 14.7 | 20.4 | 1290 |
| 2 | 35 | 0.9 | 16.8 | 23.3 | 1500 |
| 2 | 50 | 1 | 19 | 25.8 | 1890 |
| 2 | 70 | 1.1 | 22 | 29 | 2450 |
| 2 | 95 | 1.1 | 25.1 | 33.1 | 3300 |
| 2 | 120 | 1.2 | 27.9 | 36.1 | 4020 |
| 2 | 150 | 1.4 | 30.9 | 39.3 | 4750 |
| 3 | 1,5 | 0.6 | 7.8 | 12.6 | 330 |
| 3 | 2.5 | 0.7 | 9.2 | 14.1 | 390 |
| 3 | 4 | 0.7 | 10 | 15.3 | 464 |
| 3 | 6 | 0.7 | 11.2 | 16.6 | 568 |
| 3 | 10 | 0.7 | 13.1 | 19.5 | 866 |
| 3 | 16 | 0.7 | 15.3 | 21.6 | 1152 |
| 3 | 25 | 0.9 | 18.9 | 23.6 | 1800 |
| 3 | 35 | 0.9 | 21.3 | 25.7 | 2230 |
| 3 | 50 | 1 | 21.7 | 28.5 | 2490 |
| 3 | 70 | 1.1 | 25.2 | 32.2 | 3290 |
| 3 | 95 | 1.1 | 28.8 | 37 | 4440 |
| 3 | 120 | 1.2 | 32 | 40.4 | 5470 |
| 3 | 150 | 1.4 | 35.9 | 45.5 | 6930 |
| 3 | 185 | 1.6 | 40 | 49.8 | 8350 |
| 3 | 240 | 1.7 | 44.9 | 55.1 | 10400 |
| 3 | 300 | 1.8 | 49.8 | 60.2 | 12600 |
| 3 | 400 | 2 | 55.8 | 66.6 | 14600 |
| 4 | 1.5 | 0.6 | 8.5 | 13.3 | 365 |
| 4 | 2.5 | 0.7 | 9.9 | 15 | 438 |
| 4 | 4 | 0.7 | 11 | 16.4 | 532 |
| 4 | 6 | 0.7 | 12.3 | 18.7 | 764 |
| 4 | 10 | 0.7 | 14.5 | 21.1 | 1013 |
| 4 | 16 | 0.7 | 17 | 23.4 | 1360 |
| 4 | 25 | 0.9 | 21 | 26.1 | 2160 |
| 4 | 35 | 0.9 | 23.6 | 28.6 | 2690 |
| 4 | 50 | 1 | 25 | 32 | 3130 |
| 4 | 70 | 1.1 | 29.5 | 37.7 | 4500 |
| 4 | 95 | 1.1 | 33.3 | 41.7 | 5600 |
| 4 | 120 | 1.2 | 37.5 | 47.1 | 7400 |
| 4 | 150 | 1.4 | 41.6 | 51.4 | 8780 |
| 4 | 185 | 1.6 | 46.4 | 56.6 | 10630 |
| 4 | 240 | 1.7 | 52.6 | 63 | 13390 |
| 4 | 300 | 1.8 | 58 | 68.8 | 16290 |
| 4 | 400 | 2 | 65.4 | 78.1 | 19800 |
| 5 | 1.5 | 0.6 | 9.7 | 14.3 | 410 |
| 5 | 2.5 | 0.7 | 11.7 | 16.1 | 470 |
| 5 | 4 | 0.7 | 13 | 17.8 | 710 |
| 5 | 6 | 0.7 | 14.5 | 20 | 876 |
| 5 | 10 | 0.7 | 17.2 | 22.9 | 1165 |
| 5 | 16 | 0.7 | 20 | 26.6 | 1742 |
| 5 | 25 | 0.9 | 24.7 | 31.5 | 2323 |
| 5 | 35 | 0.9 | 27.8 | 34.8 | 2932 |
| 5 | 50 | 1 | 32.4 | 40.4 | 4192 |
| 7 | 1.5 | 0.6 | 10.2 | 15.2 | 470 |
| 7 | 2.5 | 0.7 | 12.3 | 17.1 | 600 |
| 7 | 4 | 0.7 | 13.6 | 19.1 | 881 |
| 12 | 1.5 | 0.6 | 13.7 | 19.4 | 780 |
| 12 | 2.5 | 0.7 | 16.3 | 22.4 | 1000 |
| 19 | 1.5 | 0.6 | 16.2 | 22.2 | 1000 |
| 19 | 2.5 | 0.7 | 19.9 | 26.6 | 1540 |
| 27 | 1.5 | 0.6 | 20 | 26.7 | 1500 |
| 27 | 2.5 | 0.7 | 24 | 30.7 | 1950 |
| 37 | 1.5 | 0.6 | 22.3 | 29 | 1800 |
| 37 | 2.5 | 0.7 | 26.9 | 33.8 | 2350 |
Class 2 Stranded Conductors for Single Core and Multi-Core Cables
| Nominal Cross Sectional Area |
Minimum No. Of Wires In Conductor | Maximum Resistance of Conductor At 20ºC |
|||||
| mm² | Circular | Circular Compacted | Shaped | Annealed Copper Conductor | |||
| Cu | Al | Cu | Al | Cu | Al | Plain Wires ohms/km | |
| 1.5 | 7 | – | 6 | – | – | – | 12.1 |
| 2.5 | 7 | – | 6 | – | – | – | 7.41 |
| 4 | 7 | – | 6 | – | – | – | 4.61 |
| 6 | 7 | – | 6 | – | – | – | 3.08 |
| 10 | 7 | 7 | 6 | 6 | – | – | 1.83 |
| 16 | 7 | 7 | 6 | 6 | – | – | 1.15 |
| 25 | 7 | 7 | 6 | 6 | 6 | 6 | 0.727 |
| 35 | 7 | 7 | 6 | 6 | 6 | 6 | 0.524 |
| 50 | 19 | 19 | 6 | 6 | 6 | 6 | 0.387 |
| 70 | 19 | 19 | 12 | 12 | 12 | 12 | 0.268 |
| 95 | 19 | 19 | 15 | 15 | 15 | 15 | 0.193 |
| 120 | 37 | 37 | 18 | 15 | 18 | 15 | 0.153 |
| 150 | 37 | 37 | 18 | 15 | 18 | 15 | 0.124 |
| 185 | 37 | 37 | 30 | 30 | 30 | 30 | 0.0991 |
| 240 | 37 | 37 | 34 | 30 | 34 | 30 | 0.0754 |
| 300 | 61 | 61 | 34 | 30 | 34 | 30 | 0.0601 |
| 400 | 61 | 61 | 53 | 53 | 53 | 53 | 0.047 |
Notes
1. Where a conductor operates at a temperature exceeding 70ºC it must be ascertained that the equipment connected to the conductor is suitable for the conductor operating temperature.
2. Where cables in this table are connected to equipment or accessories designed to operate at a temperature not exceeding 70ºC , the current ratings given in the equivalent table for 70ºC thermoplastic insulated cables must be used.
For more information, don’t hesitate to call us on +86-15838290725 or send inquiry to me.
We are China BS 6724 LSZH Sheath 0.6/1kv LV Power Swa Armored Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular LV Power Cable Products
5core, 70sqmm, Armored XLPE Power Cable
Underground Cable Aluminum Conductor Low Voltage Armoured XLPE Insulated Power Cable
Swa/Sta LV (Low Voltage) Power Cable
LV Cable 4*16mm2 Copper PVC Insulation with Steel Tape Armored Power Cable
Losh Fire Retardant XLPE Insulated PVC Sheathed Power Power Cable
Popular Power Cable Products
PVC Insulated Stranded Copper Wire Building Wire 450/750V
Flexible Electric Wire PVC Copper Cable for Sale
Low Voltage Power Cable 3X120+70mm2 Copper
Yjv 0.6/1kv 3+2 Cores Cu/Al/XLPE/PVC/Swa Power Cable
Popular Swa Cable Products
5g16mm 25mm 35mm 50mm 70mm 95mm2 Copper Cable Steel Wire Armoured Cable
4X240mm2 BS5467 Low Voltage Armoured Cable XLPE Insulated PVC Sheahted 600/1000V
Armoured Copper 4X25mm2 Power Cable with 0.6/1kv
CU/XLPE/SWA/PVC 4Cx35mm2+1Cx16mm2 ECC 0.6/1kV Underground Armored Power Cable
3X16mm2 BS5467 Low Voltage Steel Wire Armoured Cable XLPE Insulated PVC Sheahted 600/1000V
XLPE/SWA/PVC CU Armored Cable LV Power Cable 3C 300mm2 IEC 60502-1
Popular zzhongdacable Products
8.7-10 Kv Copper Conductor XLPE Inuslated Copper Wire Screened 3 X 150 Medium Tension Cable
6491b Cable Single Core Zero Halogen Low Smoke Cable
2000 Mcm Aluminum Cable XLPE PVC Insulation Electric Wire
Low Voltage XLPE 3 Phase 16mm 25mm 4 Core Conductor Na2xy Aluminium Cable
1.5mm 2.5mm Fire Resistant Single Core Fire Performance Cwz Cable
Covered Conductors Spacer Cable Hendrix 25kv, 4/0 AWG AAC
Tags: LV Power Cable, Power Cable, Swa Cable, zzhongdacable