Building Wire House Wire Tw Thw Wire ASTM
Building Wire House Wire Tw Thw Wire ASTM image
Get Latest Price Request a quote
Quick Details
Product Details
THW PVC INSULATION 600V
APPLICATION:
General purpose wiring for lighting and power – residential,
Commercial, industrial buildings in accordance with the National Electrical
Code, maximum conductor temperature of 75° C in wet or dry locations,
For circuits not exceeding 600 volts
STANDARDS:
1. Listed by UL as Type THW per Standard 83.
2. All sizes carry the VW-1 flame test designation.
3. Listed by UL as Oil Resistant I.
4. Listed by UL as Sunlight Resistant (250 kcmil and larger, black only)
5.250 kcmil and larger pass UL and IEEE-383 ribbon burner flame test
And are listed For CT Use.
6. Conforms to Federal Specification J-C-30B.
CONSTRUCTION:
Annealed uncoated copper conductor, PVC insulation, surface printed.
SPECIFICATION:
1. SCOPE
1.1 This specification describes single conductor THW, a general purpose building wire insulated with polyvinyl chloride (PVC) intended for lighting and power circuits at 600 volts or less, in residential, commercial and industrial buildings. The wire may be operated at 75° C maximum continuous conductor temperature in wet or dry locations and is listed by Underwriters Laboratories for use in accordance with Article 310 of the National Electrical Code.
2. APPLICABLE SPECIFICATIONS
2.1 The following specifications form a part of this specification to the extent specified herein:
2.1.1 Underwriters Laboratories Standard 83 for Thermoplastic Insulated Wires.
2.1. 2 Federal Specification J-C-30B.
3. CONDUCTORS
3.1 Conductors shall be solid or Class B stranded, annealed uncoated copper per UL Standard 83.
4. INSULATION
4.1 Each conductor shall be insulated with PVC complying with the physical and electrical requirements of UL Standard 83 for Type THW. In addition, the PVC insulation shall comply with the optional Oil Resistant I listing of UL Standard 83.
4.2 The average thickness of insulation, for a given conductor size, shall be as specified in UL Standard 83 for Type THW wire. The minimum thickness at any point shall be not less than 90% of the specified average thickness.
The insulation shall be applied tightly to the conductor and shall be free-stripping.
5. IDENTIFICATION
5.1 The wire shall be identified by surface marking indicating manufacturer’s identification, conductor size and metal, voltage rating, UL Symbol, type designation and optional ratings.
6. TESTS
6.1 Wire shall be tested in accordance with the requirements of UL Standard 83 for Type THW wire and for the optional Oil Resistant listing.
7. LABELS
7.1 The wire shall bear the Underwriters Laboratories label for Type THW.
NOTE:
If you want to know more details about this kind of products, please visit our website(homepage) because we have no ways to show so much information on this platform. Thank you.
Ampacity in accordance with NEC for not more than these conductors in raceway, 750C conductor temperature and 300C ambient in wet or dry locations.
| Size AWG or kcmil |
No. of strands | Insulation thickness mils |
Nominal Diameter inch |
NEC Ampacity |
Approx. weight (lbs/1000ft) | |
| copper | Net | |||||
| 14 | Solid | 30 | 0.13 | 20 | 12 | 19 |
| 12 | Solid | 30 | 0.15 | 25 | 20 | 26 |
| 10 | Solid | 30 | 0.17 | 35 | 31 | 39 |
| 14 | 7 | 30 | 0.14 | 20 | 13 | 19 |
| 12 | 7 | 30 | 0.16 | 25 | 20 | 28 |
| 10 | 7 | 30 | 0.18 | 35 | 32 | 41 |
| 8 | 7 | 45 | 0.24 | 50 | 50 | 67 |
| 6 | 7 | 60 | 0.30 | 65 | 81 | 105 |
| 4 | 7 | 60 | 0.35 | 85 | 129 | 160 |
| 3 | 7 | 60 | 0.38 | 100 | 163 | 195 |
| 2 | 7 | 60 | 0.41 | 115 | 205 | 245 |
| 1 | 19 | 80 | 0.49 | 130 | 258 | 315 |
| 1/0 | 19 | 80 | 0.53 | 150 | 326 | 390 |
| 2/0 | 19 | 80 | 0.57 | 175 | 411 | 480 |
| 3/0 | 19 | 80 | 0.62 | 200 | 518 | 595 |
| 4/0 | 19 | 80 | 0.68 | 230 | 653 | 735 |
| 250 | 37 | 95 | 0.75 | 255 | 772 | 880 |
| 300 | 37 | 95 | 0.81 | 285 | 926 | 1040 |
| 350 | 37 | 95 | 0.86 | 310 | 1081 | 1205 |
| 400 | 37 | 95 | 0.90 | 335 | 1235 | 1365 |
| 500 | 37 | 95 | 0.98 | 380 | 1544 | 1685 |
| 600 | 61 | 110 | 1.09 | 420 | 1853 | 2030 |
| 750 | 61 | 110 | 1.18 | 475 | 2316 | 2510 |
| 1000 | 61 | 110 | 1.34 | 545 | 3088 | 3305 |
If you need more information about TW,THW wire, or other wire and cables please contact us for more information.
We are China Building Wire House Wire Tw Thw Wire ASTM manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Electric Wire Products
Twin Core CCA Wire Copper Clad Aluminum Conductor Housing Wire
300V CSA 14-2 Nmd90 Copper Building Wire
Building Wir1kv BS Us Stanes Single Core Cable 10sqmm 0.6/Dard CCC ISO Certification
China Manufacturer 450/750V 70c 60227 IEC 01 (THW) From Luxing Cable
H03VV-F 3182-Y 5 Core X0.75sqmm to 10sqmm BS En 50525-2-11 Electrical Cable Wire
Popular jytopcable Products
45/7 Bittern ASTM Standard ACSR Aluminum Wire Conductor Steel Reinfored
Overhead Transmission ABC Cable to Sans 1418 Size 3X95+54.6
Professional Manufacturer for Bare Conductor AAC of DIN 48201
Copper Conductor PVC Insulation Steel Tape Armored Power Cable Nyby
300/500V Ydyp Cable 3X2.5mm with Ce Certificate
Electrical Silver Coated Copper Wire Silver Aluminum Alloy Wire
Popular Thw Wire Products
Electrical Wire Thhn Tw Thw Cable Building Wire Aluminum Thhn Wire 600V 250 Mcm UL
Easy Cutting UL1015 Thhn Wire UL 10AWG for Electronic Equipment Cable
Thw/Tw House Wire with Safe Standard and Certificate
600V AWG Copper Conductor PVC Insulated Thw Tw Electric Wire
Experienced Supplier for PVC Insulated Electric Wire
Popular Tw Wire Products
600V 14 12 10 8 6 AWG Copper Conductor PVC Insulated Thw Tw Electric Wire
IEC 60227 Tw Thw Thw-2 4mm² 6mm² 10mm² Flame Retardant Communication Building Power Cable Wire
600V 4AWG 2 Copper Conductor PVC Insulated Thw Tw Electric Wire
Cable Ttu 500mcm 250 Mcm 4/0 3/0 2/0 AWG 600V
Tags: Electric Wire, jytopcable, Thw Wire, Tw Wire