Overview

Basic Info.

Model NO.
CAAI

Insulation Material
XLPE

Sheath Material
No

Material Shape
Round Wire

Certification
ISO, CCC, CE

Model
Caai Cable

Brand
Zoom Link

ODM or OEM
Ok

Prepayment
30%

Type of Company
Manufacturer

Delivery Time
About 30 Days

Samples
Free

Quality
100% Test Each Drum

Colour
Black or Others

Transport Package
Drum

Specification
customized

Trademark
ZML

Origin
China

HS Code
8544492100

Production Capacity
50000m Per Day

Product Description

Product Description

Caai Cable Alumnium Alloy Aerial Bundle XLPE Insulate PE Sheath Overhead 2*50+Na35mm2

1.Description

 CABLES AUTOPORTANTES MULTI-CONDUCTORES DE ALUMINIO.

 Aluminum conductor with aluminum alloy supporting cable (support conductor can be bare "ND" or insulated "NA")
 

2.Application

-For overhead networks of secondary energy distribution low‐cost electricity, in urban and rural areas.
-Whether it’s on the post or on the wall cases, with appropriate attachments. They don’t need to be used insulator

3.Standards
We can supply this conductor according to different recognized standards, such as :

International IEC 60228;
IEC 60811-201; IEC 60811-401;
IEC 60811-402; IEC 60811-501;
IEC 60811-502; IEC 60811-507;
IEC 60811-511
National ASTM A 475;
NTP 370.254;
NTP-IEC 60228

customer special specification also can be satisfied,we will do our best to meet your requirements

4.OPERATING TEMPERATURE

90º C 
130ºC in emergency conditions.
250ºC in short circuit conditions.

5.Rated voltage
U0 / U = 0.6 /1 kV

6. SPECIAL PRECAUTIONS
It is recommended not to use these cables in areas with salty or contaminated environment, due to the low corrosion resistance of aluminum.
The derivations and connections with copper cables should be made by means of appropriate techniques should be used.
During installation, care should be taken not to damage the cable surface. 

CAAI CABLE (ND)

DIMENSIONAL AND ELECTRICAL CHARACTERISTICS

 

TRAINING

Phase Insulation
thickness
External Diameter
(*)
Nominal Mass Maximum D.C. Resistance 20 ºC
Ohm/km
Inductive Reactance at 60Hz
Ohm/km
Voltage drop
Factor(**) V/A km
mm mm Kg/km Phase lighting Phase lighting Phase lighting
1×16+ND25 1.14 17 125 1.910 0.0943 3.491
2×16+ND25 1.14 17 190 1.910 0.0957 3.493
2×25+ND25 1.14 19 245 1.200 0.0873 2.223
2×35+ND25 1.14 20 305 0.868 0.0825 1.628
2×50+ND35 1.52 24 430 0.641 0.0832 1.225
2×70+ND50 1.52 28 600 0.443 0.0833 0.874
2×95+ND70 1.52 32 800 0.320 0.0807 0.652
2×120+ND70 2.03 35 960 0.253 0.0785 0.531
2×25+16+ND25 1.14 19 310 1.200 1.910 0.0925 0.1093 2.229 3.507
2×35+16+ND25 1.14 20 370 0.868 1.910 0.0862 0.1135 1.632 3.511
2×50+16+ND35 1.52 24 490 0.641 1.910 0.0843 0.1242 1.227 3.523
2×70+16+ND50 1.52 28 660 0.443 1.910 0.0822 0.1352 0.872 3.534
2×95+16+ND70 1.52 32 860 0.320 1.910 0.0781 0.1436 0.649 3.543
3×16+ND25 1.14 17 250 1.910 0.1030 3.500
3×25+ND25 1.14 19 340 1.200 0.0952 2.231
3×35+ND25 1.14 20 420 0.868 0.0906 1.636
3×50+ND35 1.52 24 590 0.641 0.0912 1.234
3×70+ND50 1.52 28 830 0.443 0.0913 0.882
3×95+ND70 1.52 32 1 100 0.320 0.0888 0.660
3×120+ND70 2.03 35 1 350 0.253 0.0868 0.539
3×16+16+ND25 1.14 17 310 1.910 1.910 0.1095 0.1095 3.507 3.507
3×25+16+ND25 1.14 19 400 1.200 1.910 0.0995 0.1163 2.236 3.514
3×35+16+ND25 1.14 20 490 0.868 1.910 0.0935 0.1208 1.639 3.519
3×35+16+ND35 1.14 20 520 0.868 1.910 0.0935 0.1208 1.639 3.519
3×50+16+ND35 1.52 24 650 0.641 1.910 0.0925 0.1323 1.235 3.531
3×50+25+ND35 1.52 24 680 0.641 1.200 0.0925 0.0952 1.235 2.231
3×70+16+ND50 1.52 28 890 0.443 1.910 0.0910 0.1440 0.882 3.543
3×95+16+ND70 1.52 32 1 170 0.320 1.910 0.0875 0.1529 0.659 3.552
3×120+16+ND70 2.03 35 1 410 0.253 1.910 0.0841 0.1583 0.536 3.558
CAAI CABLE (NA)

DIMENSIONAL AND ELECTRICAL CHARACTERISTICS

TRAINING

Phase Insulation thickness External Diameter (*) Nominal Mass Maximum D.C. Resistance 20 ºC Ohm/km Inductive
Reactance at 60 HZ
Ohm/km
Voltage drop Factor(**) V/A km
  mm mm Kg/km Phase lighting Phase lighting Phase lighting
1×16+NA25 1.14 18 160 1.910 0.0943 3491
2×16+NA25 1.14 18 220 1.910 0.0957 3.493
2×25+NA25 1.14 21 280 1.200 0.0873 2.223
2×35+NA25 1.14 22 340 0.868 0.0825 1.628
2×50+NA35 1.52 26 470 0.641 0.0832 1.225
2×70+NA50 1.52 30 660 0.443 0.0833 0.874
2×95+NA70 1.52 34 860 0.320 0.0807 0.652
2×120+NA70 2.03 38 1020 0.253 0.0785 0.531
2×25+16+NA25 1.14 21 340 1.200 1.910 0.0925 0.1093 2.229 3.507
2×35+16+NA25 1.14 22 400 0.868 1.910 0.0862 0.1135 1.632 3.511
2×50+16+NA35 1.52 26 530 0.641 1.910 0.0843 0.1242 1.227 3.523
2×70+16+NA50 1.52 30 720 0.443 1.910 0.0822 0.1352 0.872 3.534
2 x 95+16+NA70 1.52 34 920 0.320 1.910 0.0781 0.1436 0.649 3.543
2×120+16+NA70 2.03 38 1080 0.253 1.910 0.0746 0.1487 0.526 3.548
3×16+NA25 1.14 18 280 1.910 0.1030 3.500
3×25+NA25 1.14 21 370 1.200 0.0952 2.231
3×35+NA25 1.14 22 450 0.868 0.0906 1.636
3×50+NA35 1.52 26 630 0.641 0.0912 1.234
3×70+NA50 1.52 30 880 0.443 0.0913 0.882
3×95+NA70 1.52 34 1160 0.320 0.0888 0.660
3×120+NA70 2.03 38 1410 0.253 0.0868 0.539
3×16+16+NA25 1.14 18 340 1.910 1.910 0.1095 0.1095 3.507 3.507
3×25+16+NA25 1.14 21 430 1.200 1.910 0.0995 0.1163 2.236 3.514
3×35+16+NA25 1.14 22 520 0.868 1.910 0.0935 0.1208 1.639 3.519
3×35+16+NA35 1.14 22 560 0.868 1.910 0.0935 0.1208 1.639 3.519
3×50+16+NA35 1.52 26 690 0.641 1.910 0.0925 0.1323 1.235 3.531
3×50+25+NA35 1.52 26 720 0.641 1.200 0.0925 0.0952 1.235 2.231
3×70+16+NA50 1.52 30 950 0.443 1.910 0.0910 0.1440 0.882 3.543
3×95+16+NA70 1.52 34 1230 0.320 1.910 0.0875 0.1529 0.659 3.552
3×120+16+NA70 2.03 38 1470 0.253 1.910 0.0841 0.1583 0.536 3.558

 

Detailed Photos

 

Packaging & Shipping

 

Packing:  wooden drum,iron-wooden drum,Woven Bag wrapping

Shipping: transport by sea

Port: Qingdao

As the customers requirements

Woven Bag wrapping(soft packing/rolls) : 
Advantages: low price, light weight and space saving.

Wooden Drum Packing Details:
The wooden drum will be fumigated.

Wooden Steel Drum: 
This wooden-steel drum is suitable for cables with an outer diameter of more than 30mm. 

 

Company Profile




 

FAQ

FAQ

1.Are you a manufacturer or trading company?
We are a professional manufacturer.We can control your order from the first beginning to the last.
Welcome to visit us.We’ll pick you up in Zhengzhou

2. How can I get a sample to test your quality?
The samples are free for you.New clients are expected to pay for the courier cost.
3.What’s your Minimum Order Quantity?
Normally 1000m.How ever the cable is very heavy.
You’d better order a suitable quantity to avoid the high freight.
Sea transportation is the best option.

4.Can I get a discount?
It depends on your quantity,We can make a discount and afford the freight.
Pls kindly contact us.

5. Does your company accept OEM production?
Yes, could print your company name we even custom the quality card to promote your company.
 

Certifications

 


 

We are China Caai Cable Alumnium Alloy Aerial Bundle XLPE Insulate Overhead 2*50+Na35mm2 manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular ABC Cable Products

ASTM Quadruplex ABC Cable, Electric Cable, Power Cable

3+1+K Cores 0.6 / 1kv Aluminum Conductor XLPE Insulation Aerial Bundle Cable

ABC Cable Aluminum PE/XLPE for Overhead

0.6/1kv Aluminium Core XLPE Insulated Overhead Cluster ABC Cable

XLPE Insulated Service Cable (SDW)

PVC / XLPE Insulated ABC Cable

Popular Caai Cable Alumnium Alloy Aerial Bundle XLPE Insulate Overhead 2*50+Na35mm2 Products

  • No related articles
  • Popular Cable Products

    Copper Flexible Cable (Wire) PVC Insulated Electrical/Electric Power Wire Cable

    11kv 15kv 3 Core Copper Aluminum Conductor XLPE Insulated Electrical Power Cable

    Elevator Cables Yt Ytb Ytf Braided PVC Insulated Elevator Rubber Cable

    BS215 Standard Sheep 350mm2 Aluminum and Steel Stranded Bare Electrical Cable ACSR Conductor

    0.6/1kv Power Transmission Concentric Cable

    XLPE Insulated PVC Sheath Cable with High Quality

    Popular zmlcable Products

    PVC/XLPE Insulated Overhead Cables Aerial Aluminum Twisted Cable

    BS Standard Aluminium Conductor Steel Reinforced ACSR 50 100 120 150

    1.68 to 4.77 mm Galvanized Steel Wire Use for ACSR and Guy Wire and Stay Wire

    Conductor Desnudo AAAC 559.5 Mcm Darien; AAAC 312.8 Mcm Butte

    Low Voltage and High Voltage XLPE Insulation Copper& Aluminum Conductor Power Cable

    Fluoroplastic Insulation or Silicon Rubber Insulation High Temperature Resistant Wire and Cable

    Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION