Cable Conductor ACSR, AAAC, AAC Naked Conductor
Cable Conductor ACSR, AAAC, AAC Naked Conductor image
Get Latest Price Request a quote
Quick Details
Product Details
Cable Conductor ACSR, AAAC, AAC Naked Conductor
1.Applications
Conductor(AAC,AAAC and ACSR) have been widely used in power transmission lines with various voltage levels,because they have such good characteristics as simple structure,convenient installation and maintenance,low cost large transmission capacity.And they are also suitable for laying across rivers valleys and the places where special geographical features exist.
2.Service Performance
(1).The permissible long-time operating temperature for aerial conductor is 70oC.
(2).Under the circumstance that rare climate is occuring and ice coverage rate low in heavy ice area,the biggest stress of cable at the lowest point of the sag should not exceed 60% of the short-time destructive power.
(3).When connecting conductors,the conductor beside the connecting tube cant be prominent.Otherwise,the force on the operating conductors will be unbalanced.After connectors are install,the connecting tube should be painted by moisture-proof varnish in order to protect it from corrosion.
(4).Under installaion,the arc downing stress of all the conductors should be the same.With in the permissible distance of crossing buildings or dropping to the ground,the stress can be 10-15% higher than regular stress.
3.Material Standard
(1).The hard aluminum conductor used for AAC and ACSR conforms to the standard GB/T 17048-1997(equivalent to IEC 60889:1987).
(2).The zinc coated steel wire used for ACSR conforms to IEC 60888:1987.
(3).Production can be arranged according to customers requirements for material standard,etc.
Construction of All Aluminum Conductor and Aluminum Conductor Steel Reinforced
4.Technical details
AAC Technical Characteristics Based on Standard DIN 48201 / DIN EN50182
| Code number | Area | Number of wires | Wire diameter | Conductor diameter | Linear mass | Rated strength | D.C. resistance at 20oC |
| mm2 | No. | mm | mm | kg/km | kN | Ω/km | |
| 16 | 15.9 | 7 | 1.7 | 5.1 | 43.4 | 3.02 | 1.7986 |
| 25 | 24.2 | 7 | 2.1 | 6.3 | 66.3 | 4.36 | 1.1787 |
| 35 | 34.4 | 7 | 2.5 | 7.5 | 93.9 | 6.01 | 0.8317 |
| 50 | 49.5 | 7 | 3 | 9 | 135.2 | 8.41 | 0.5776 |
| 50 | 48.3 | 19 | 1.8 | 9 | 132.9 | 8.94 | 0.5944 |
| 70 | 65.8 | 19 | 2.1 | 10.5 | 180.9 | 11.85 | 0.4367 |
| 95 | 93.3 | 19 | 2.5 | 12.5 | 256.3 | 16.32 | 0.3081 |
| 120 | 117 | 19 | 2.8 | 14 | 321.5 | 19.89 | 0.2456 |
| 150 | 147.1 | 37 | 2.25 | 15.8 | 405.7 | 26.48 | 0.196 |
| 185 | 181.6 | 37 | 2.5 | 17.5 | 500.9 | 31.78 | 0.1588 |
| 240 | 242.5 | 61 | 2.25 | 20.3 | 671.1 | 43.66 | 0.1193 |
| 300 | 299.4 | 61 | 2.5 | 22.5 | 828.5 | 52.4 | 0.0966 |
ACSR Technical Characteristics Based on Standard BS 215-2
| Code name | Nominal aluminium area | Stranding and wire diameter | Sectional area of aluminium | Total sectional area | Approx. overall diameter | Approx. mass | Calculated D.C. resistance at 20oC | Calculated breaking load | |
| Al | Steel | ||||||||
| mm2 | No./mm | mm2 | mm2 | mm | kg/km | Ω/km | kN | ||
| RABBIT | 50 | 6/3.35 | 1/3.35 | 52.88 | 61.7 | 10.05 | 214 | 0.5426 | 18.35 |
| DOG | 100 | 6/4.72 | 7/1.57 | 105 | 118.5 | 14.15 | 394 | 0.2733 | 32.7 |
| WOLF | 150 | 30/2.59 | 7/2.59 | 158.1 | 194.9 | 18.13 | 726 | 0.1828 | 69.2 |
| DINGO | 150 | 18/3.35 | 1/3.35 | 158.7 | 167.5 | 16.75 | 506 | 0.1815 | 35.7 |
| LYNX | 175 | 30/2.79 | 7/2.79 | 183.4 | 226.2 | 19.53 | 842 | 0.1576 | 79.8 |
| ZEBRA | 400 | 54/3.18 | 7/3.18 | 428.9 | 484.5 | 28.62 | 1621 | 0.0674 | 131.9 |
AAAC Technical Characteristics Based on Standard BS 3242
| Code name | Nominal aluminium area | Stranding and wire diameter | Sectional area | Approx. overall diameter | Approx. mass | Calculated D.C. resistance at 20oC | Calculated breaking load |
| mm2 | No./mm | mm2 | mm | kg/km | Ω/km | kN | |
| ALMOND | 25 | 7/2.34 | 30.1 | 7.02 | 82 | 1.094 | 8.44 |
| CEDAR | 30 | 7/2.54 | 35.47 | 7.62 | 97 | 0.9281 | 9.94 |
| FIR | 40 | 7/2.95 | 47.84 | 8.85 | 131 | 0.688 | 13.4 |
| HAZEL | 50 | 7/3.30 | 59.87 | 9.9 | 164 | 0.5498 | 16.8 |
| OAK | 100 | 7/4.65 | 118.9 | 13.95 | 325 | 0.2769 | 33.3 |
| ASH | 150 | 19/3.48 | 180.7 | 17.4 | 497 | 0.183 | 50.65 |
| ELM | 175 | 19/3.76 | 211 | 18.8 | 580 | 0.1568 | 59.1 |
| UPAS | 300 | 37/3.53 | 362.1 | 24.71 | 997 | 0.09155 | 101.5 |
Company Information
We are China Cable Conductor ACSR, AAAC, AAC Naked Conductor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular AAC Conductor Products
as Standard Overhead Cable ACSR Apple Bare Conductor
DIN Standard 120/20mm2 ACSR Bare Aluminum Conductor Cable
High Quality Bare Aluminium Conductor All Aluminium AAC
AAC Aluminum Wires Stranding Conductor
Aluminum AAC AAAC Hard Drawn Standard Bare Steel Reinforced Overhead ACSR Conductor
CSA C49 Standard AAC Conductor
Popular Aluminum Conductor Products
Aluminum Conductor Steel Reinforced DIN48204
Underground CSA68.5 35kv Urd Cable Medium Voltage Power Mv90, Mv105
Bare Aluminum Conductor AAC, Acs, AAAC, ACSR, Acar, ACSR/Aw Conductor
ACSR Bare Conductor ASTM BS IEC NFC Standard
5 Core XLPE Insulated Lt Aerial Bunch Cable, 120 Sq mm, Aluminum Conductor ABC Cable
Popular Aluminum Wire Products
100mm2 Wasp All Aluminum Conductor, Bare (AAC HD Bare conductor)
AAAC Conductor All Aluminium Alloy Conductor ASTM Standard
2AWG 3core Aluminum XLPE PVC Electric Distribute Power Cable
High Quality China Manufacturer 99% Pure Aluminum Wire 1350 1370
PVC Coated Electric Aluminum Wire Flexible Cable
Popular zzjinshui Products
Red Color Countrol Cable for Equipment-Household
Corrosion-Resistant PVC Sheathed Armoured Power Cable
Standard All Aluminum Conductor AAC AAAC Acar ACSR
XLPE Insulation High Voltage Cable PVC Sheathed Power Cable Mv Cable
Overhead Power Transmission Line Bare AAAC Conductor
Naked Acar Conductor 300mcm (12+7) /3.192mm Astmb524 Standard
Tags: AAC Conductor, Aluminum Conductor, Aluminum Wire, zzjinshui