Class1 Line Discharge Level 21kv 5ka Polymeric Composite Lighting Arrester
Class1 Line Discharge Level 21kv 5ka Polymeric Composite Lighting Arrester image
Get Latest Price Request a quote
Quick Details
Product Details
0.28kV~500kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
Type | YH5W5-21/56 | 4/10µS High current impulse kA | 65 |
Rated voltage———kV | 21 | Lightning impulse withstand kV | 125 |
MCOV —————-kV | 17 | Power frequency voltage withstand(dry/wet)kV | 50 |
Nominal Current——-kV | 5 | 0.1S TOV————–kV | 25.2 |
Residual voltage of steep impulse—-at 5kA(kV) | 60.5 | 1S TOV—————-kV | 24.15 |
8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 56 | 10S TOV—————kV | 23.1 |
Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | / | 1200S TOV————-kV | 21 |
1mA D.C reference voltage (kV) | 29.7 | Creepage distance —-mm | 662 |
Line discharge level | 1 | Material employed in series non-linear resistor | Zinc Oxide |
2mS long duration impulse current A | 250 | Material of housing | silicone rubber |
Working condition:
Environment temperature: -40–+40 degree | |||||||
altitude:<1000m | |||||||
48HZ<Rated frequency<62HZ | |||||||
Power frequency voltage should not be more than continuous running voltage | |||||||
Max wind speed should be less than 35m/s | |||||||
Earthquake intensity should be less than 7 degree | |||||||
If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China Class1 Line Discharge Level 21kv 5ka Polymeric Composite Lighting Arrester manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
OEM Polymer Silicone Material 30kv 10ka Class 2 Type High Voltage Arrester
Medium Voltage Isolator Switch Fuse Disconnector
Ceramic Silicon Rubber Insulator
Line Discharge Level 2 Substation Outdoor Ceramic Housing Arresters
Hangzhou Yongde Zov Metal Oxide Varistor Manufacturers
Porcelain Arrester Lightning Arrestor Surge Protector for Transformer
Popular Lightning Arrester Products
Yh10W-216.216kv 10ka Surge Arrester
Metal-Oxide Surge Protective Device Factory
Yh10W-9, Sharp Head 10kv 9ka Surge Arrester
Popular Surge Arrester Products
132kv Silicone ZnO Surge Protector for 500kv Transmission Lines
Kema Low Voltage Metal Oxide Gapless Surge Arrester Lightning
Zinc Oxide Arrester Porcelain Surge Arrester
Pole Anti-Collision Warning Sticker
Metal-Oxide Lightning Protector, Surge Arrester Yh5w, Yh10W
Popular Surge Arresters Products
Rated Voltage 100kv 110kv 120kv Transmission Line Type ZnO Lightning Diverter
Kema Power Transmission Type Metal Zinc Oxide Surge Arrester
Electrical Equipment Supplies 30kv 33kv Composite Zinc Oxide Surge Arresters
Line Discharge Level 2 Substation Outdoor Ceramic Housing Arresters
10ka Power Station Type Ceramic ZnO Surge Diverters with Silicone Housed
Hv Ceramic Housed Metal Oxide Arrester Lightning 110kv
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters