Compressed Conductor Aluminium Core Cross-Linked XLPE Insulation Urd Cable
Compressed Conductor Aluminium Core Cross-Linked XLPE Insulation Urd Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Aluminium Conductors. Polythylene or Crosslinked Polyethylene Insulation.
ABC Cables Applications:
Used to supply 3 phase power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.
ABC Cables Construction:
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR.One conductor is manufactured with an extruded ridge for phase identification.
ABC Cables Standards:
1.B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2.B-231 Aluminum conductors, Concentric-Lay-Stranded.
3.B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
4.B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
5.B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6.Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
ABC Cables Using Properties
1.Rated Voltage:0.6/1kV
2.Cable installation temperature not less than -20°C
3.Max. temperature of cable at short circuit(The max. duration does not exceed 5 minutes)
For XLPE insulation is 250°C.
For HDPE insulation is 150 °C.
4.The Max. bending radius of cable shall not be less than 20Dmm(D overall diameter of cable)
Type of ABC Cable
1.Duplex Service Drop:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75 maximum.
2.Triplex Service Drop: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation .
3.Quadruplex Service Drop: Used to supply 3 phase power , usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made . To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
ASTM B-230, B-231 and ICEA S-66-524
UL Standard 854 for type USE
Federal Specification JC-30B NEC
|
Code Name |
Phase Conductor |
Neutral |
Single Phase Conductor(in) |
Outside diameter(in) |
Weight Per 1000ft (lbls) |
Ampacity |
|||||
|
Size AWG |
Strand |
Insulation Thickness (mls) |
Size AWG |
Strand |
Insulation Thickness (mls) |
Direct Burial |
In Duct |
||||
|
Tulsa |
4 |
7/w |
60 |
4 |
7/w |
60 |
.345 |
.833 |
258 |
119 |
85 |
|
Dyke |
2 |
7/w |
60 |
4 |
7/w |
60 |
.403 |
.938 |
346 |
153 |
115 |
|
Wittenberg |
2 |
7/w |
60 |
2 |
7/w |
60 |
.403 |
.973 |
375 |
153 |
115 |
|
Notre Dame |
1/0 |
19/w |
80 |
2 |
7/w |
60 |
.522 |
1.188 |
541 |
198 |
150 |
|
Purdue |
1/0 |
19/w |
80 |
1/0 |
19/w |
80 |
.522 |
1.260 |
596 |
198 |
150 |
|
Syracuse |
2/0 |
19/w |
80 |
1/0 |
19/w |
80 |
.566 |
1.316 |
664 |
225 |
170 |
|
Lafayette |
2/0 |
19/w |
80 |
2/0 |
19/w |
80 |
.566 |
1.367 |
720 |
225 |
170 |
|
Swarthmore |
3/0 |
19/w |
80 |
1/0 |
19/w |
80 |
.616 |
1.430 |
805 |
250 |
195 |
|
Davidson |
3/0 |
19/w |
80 |
3/0 |
19/w |
80 |
.616 |
1.487 |
874 |
250 |
195 |
|
Wake Forest |
4/0 |
19/w |
80 |
2/0 |
19/w |
80 |
.672 |
1.560 |
979 |
290 |
225 |
|
Earlham |
4/0 |
19/w |
80 |
4/0 |
19/w |
80 |
.672 |
1.623 |
1066 |
290 |
225 |
|
Slippery Rock |
350 |
37/w |
95 |
4/0 |
19/w |
80 |
.851 |
1.945 |
1544 |
385 |
305 |
|
Wofford |
500 |
37/w |
95 |
350 |
37/w |
95 |
.851 |
2.348 |
2174 |
467 |
420 |
|
Windham |
750 |
61/w |
110 |
500 |
37/w |
95 |
.979 |
2.850 |
2542 |
615 |
492 |
We are China Compressed Conductor Aluminium Core Cross-Linked XLPE Insulation Urd Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Compressed Conductor Products
Aerial Bundled Cable Compressed Conductor ABC Overhead Cable
Popular Cross-Linked XLPE Insulation Products
Popular huatongcable Products
300/500 450/750 PVC Insulated Flame Retardant Electrical Wire Power Wire
ACSR Conductor Teal Transmission Line
IEC60502-2 XLPE Insualted Armoured Underground 6/10kv Copper Cable 3X95mm2
Rvv, RV BS6004 Single Core Flexible Cable
Medium Voltage XLPE Cable, 11kv PVC Sheathed Marine Power Cable
300/500V Electric Wire for Equiments
Popular Urd Cable Products
PVC or PE Mv-90 Standard Export Drum 25kv Urd Mv-105 Cable
4/0 15kv Trxlpe 133% Insulation with 1/3neutral LLDPE Sheathed Urd Cable with UL Listed
15kv Urd Cable 133% 2AWG 2/0AWG 4/0AWG