Connectors
Connectors image
Get Latest Price Request a quote
Quick Details
Product Details
| 8 | Rules | ANCI C119.4, IEEE 48-1996 | |
| 9 | Quality certificate | ISO 9001 | |
| 10 | Approval certificate | Attach certificate of acceptance of DN-DS |
|
| 11 | Permissible driver 3/0 | AWG | ACSR, AAC, AAAC, CU |
| 12 | Dimension | ||
| 13 | Nominal size of the driver |
AWG | No. 3/0 |
| Diameter of driver applying approximate | mm | 11.53 | |
| 14 | Number of Holes | u | 2 |
| 15 | Identification color | Orange | |
| Dimension | |||
| 16 | Diameter of the hole | inch(mm) | 9/16 (14.29) |
| 17 | Distance between holes | inch(mm) | 1-3 / 4 (44.45) |
| 18 | Approximate length (L) | inch(mm) | 3- 1/7 (80) |
| 19 | Width (W) | inch(mm) | Specify |
| 20 | Thickness | inch(mm) | 0.18 (4.57) |
| 21 | Dialing | You must present the mark or symbol of the manufacturer |
|
| 22 | Packaging | It should be packed in a box Highly resistant cardboard identified with a label describing the caliber # 2 AWG, manufacturer, quantity, country of origin |
| Product | Tension Clamp 100-150mm Square | ||||||
| Test Items | Test Content | Test Result | |||||
| Sample 1 |
Sample 2 |
Sample 3 |
Sample 4 |
Sample 5 |
Remarks | ||
| Visual Inspection | Crack | √ | √ | √ | √ | √ | 1) Passed Mark"√" 2) Not Passed Mark"×" Test Conclusion: |
| Stoma Trachoma | √ | √ | √ | √ | √ | ||
| Fins | √ | √ | √ | √ | √ | ||
| Burr | √ | √ | √ | √ | √ | ||
| Mechanical Characteristics | Mechanical Load | √ | √ | √ | √ | √ | 1)Passed Mark"√" 2)Not Passed Mark"×" Test Conclusion: |
| Inspector | Date: 18. June,2010 Approved: | ||||||
| S/N | DETAILS | UNITS | DATA |
| 1. | Type | 100mm2 Compression type mid span joint complete with a tubular aluminium outer extrusion ,steel inner sleeve and two filler plugs |
|
| 2. | Material for outer extrusion |
Aluminium -99.5% purity | |
| 3. | Material for inner sleeve | HDG steel | |
| 4. | Type of inner sleeve | Tubular, suitable for compression into hexagonal shape |
|
| 5. | Suitable for the following ACSR Conductor Size |
mm2 | 100 |
| 6. | Resistivity | Less than 75% of the resistivity of an equivalent length of conductor. |
|
| 7. | Minimum failing load | kN | 35 |
| 8. | Operating ambient temperature |
°C | -1 to 40 |
| 9. | Relative Humidity | % | 85 |
| 10. | Altitude above sea level | m | 1400 |
CLAMP P/G ALUMINIUM/ALUMINIUM 100/100 MM2
| S/N | TYPE | CONDUCTOR CROSS SECTION AREAS (mm2) |
NUMBER AND MATERIAL OF BOLT |
CLAMP BODY MATERIAL |
DIMENSI ONS |
| 1. | Aluminium/Aluminiu m conductor connection |
100/100 | 2 X Galvanised mild steel bolts |
Aluminium | As per Drawing No.E11389 shown below |
| Other dimensions | |||||
| 2. | Drawings showing dimensions to be provided with bid |
Yes/No | Yes | ||
| 3. | Previous type tests results/certificate to be provided with bid |
Yes/No | Yes | ||
| 4. | Quality assurance certificate to be provided with bid |
Yes/No | Yes | ||
| 5. | Applicable standard | IEC standards | |||
We are China Connectors manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Bolt and Nuts Products
Spike for Insulator Head Pole 18 ", Thread 1" of Nylon 18
High Strength Ground Rod Coupling Ground 1800mm
Pole Line Hardware for Transmission and Distribution Line
Spindle for Steel Angular Crosshead 5/8
Terminal Connectors for Large Cross-Sectional Conductor Type SL, Bolted Type
Popular Connectors Products
One-Side Entry Wire Terminal Strip Connectors for LED Light
Cable Connectors for Taping Bare Conductors AAAC (AACSR)
Cable Clamps Copper Dead-End Clamps Copper
Splice Compression Sleeve Preinsulated No. 4/0 to 4/0 AWG
Insulating Piercing Connector Standard Type
H Parallel Groove Compression Tap Connector H Tap Connector
Popular jgtrade1 Products
Polymer Surge Arrester Pointed End Head
Ceramic Drop Fuse 11kv 20kv 24kv 33kv 36kv 38kv 100A 200A 300A Circuit Breaker
Street Lamp Special Distribution Box
Polymer Fuse Cutout, Drop out Fuses 12kv 600A
Popular Pole Line Hardware Products
Pole Clamp Adapter HDG Pole Line Hardware
Drop Forged Steel Vic Anchor Chain Shackle with U Type
Dlt Copper Aluminum Connecting Terminals
Pole Top Pin Insulator Pin HDG Nylon/Leading Head
Tags: Bolt and Nuts, Connectors, jgtrade1, Pole Line Hardware