Control Cable Fr-XLPE Insulated Copper Conductors 600V 14AWG
Control Cable Fr-XLPE Insulated Copper Conductors 600V 14AWG image
Get Latest Price Request a quote
Quick Details
Product Details
Applications
As flame-retardant multi-conductor control, signal or power cables rated 600 volts, 90 ºC in wet or dry locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Also approved for use in Class I remote-control and signaling circuits per Article 725 of the NEC. Type TC cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may be installed in air, in ducts or conduits, in tray or trough, and are suitable for direct burial.
Construction
Stranded uncoated copper conductors, 30 mils FR-XLPE flame-retardant crosslinked polyethylene insulation, color coded, two conductors flat, three or more conductors twisted with suitable fillers where necessary to make round, cable tape, PVC jacket overall, surface printed.
Standards
- Listed by UL as Type TC per Standard 1277 for Tray Cables.
- Cables UL listed for Direct Burial.
- Individual conductors pass UL VW-1 flame test.
- Individual conductors UL listed as Type XHHW-2.
- Overall jacket UL listed as Sunlight Resistant.
- Cables with grounding conductor UL listed for Open Wiring.
- Cables pass IEEE-383 ribbon burner flame test and ICEA 210,000 BTU/hour test.
- Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test.
- Cables meet requirements of ICEA S-73-532, NEMA WC70 for Control Cables.
Notes
- Cables may be supplied with an insulated ground and marked ""Open Wiring.""
- Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73-532(TECH I006). This color coding method omits white and green from the color sequence. A white or green conductor can be supplied on request.
- Color Coding also available ICEA Method 1, Table E-1; power sizes, ICEA Method 4.
Options
- Bare or Tinned Copper
- Flexible stranded conductors
- E1 or E2 color codes
- EPR Insulation
- CPE, CSPE, LSOH jackets
- Overall copper tape shield
- Overall copper braid shield
- Overall longitudinal corrugated copper shield
- Overall mylar tape shield with drain wire
- 1000 volt rated construction
Consult AWG for a variety of alternate constructions for specific applications.Applications
As flame-retardant multi-conductor control, signal or power cables rated 600 volts, 90 ºC in wet or dry locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Also approved for use in Class I remote-control and signaling circuits per Article 725 of the NEC. Type TC cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may be installed in air, in ducts or conduits, in tray or trough, and are suitable for direct burial.
Construction
Stranded uncoated copper conductors, 30 mils FR-XLPE flame-retardant crosslinked polyethylene insulation, color coded, two conductors flat, three or more conductors twisted with suitable fillers where necessary to make round, cable tape, PVC jacket overall, surface printed.
Standards
- Listed by UL as Type TC per Standard 1277 for Tray Cables.
- Cables UL listed for Direct Burial.
- Individual conductors pass UL VW-1 flame test.
- Individual conductors UL listed as Type XHHW-2.
- Overall jacket UL listed as Sunlight Resistant.
- Cables with grounding conductor UL listed for Open Wiring.
- Cables pass IEEE-383 ribbon burner flame test and ICEA 210,000 BTU/hour test.
- Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test.
- Cables meet requirements of ICEA S-73-532, NEMA WC70 for Control Cables.
Notes
- Cables may be supplied with an insulated ground and marked ""Open Wiring.""
- Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73-532(TECH I006). This color coding method omits white and green from the color sequence. A white or green conductor can be supplied on request.
- Color Coding also available ICEA Method 1, Table E-1; power sizes, ICEA Method 4.
Options
- Bare or Tinned Copper
- Flexible stranded conductors
- E1 or E2 color codes
- EPR Insulation
- CPE, CSPE, LSOH jackets
- Overall copper tape shield
- Overall copper braid shield
- Overall longitudinal corrugated copper shield
- Overall mylar tape shield with drain wire
- 1000 volt rated construction
Consult AWG for a variety of alternate constructions for specific applications.
Specification Data
Package and Delivery
We are China Control Cable Fr-XLPE Insulated Copper Conductors 600V 14AWG manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Control Cable Products
PVC Sheathed Flexible Control Cable, XLPE Insulated, Copper Conductor, Power Cable, Electric Cable
PVC Copper Conductor XLPE Insulated Kyjv Kyjvp Control Cable
Plastic Insulated Control Cable PVC Insulated Power Cable
Power Cable Electric Cable Copper Wire
Popular Copper Conductor Products
Factory Price of 0.6/1kv Cu/XLPE/Swa/PVC Power Cable
Copper Conductor Rubber Insulation Rubber Sheath Trailing Cable
70mm2 Yjv Power Electric Sheath Cable
Copper Clad Steel Earth Rod Overhead Conductor
Low Voltage 0.6/1kv Yjv 240mm 4core 3 Core Electrical Cable
UL62 4c 18AWG Rubber Jacket Power Cable S, So, Soo, Sow, Soow Cable
Popular Fr-XLPE Insulated Products
Control Cable Fr-XLPE Insulated Copper Conductors 600V 10 AWG
Control Cable Fr-XLPE Insulated Copper Conductors 600V 10 AWG
14 AWG Control Cable Fr-XLPE Insulated Conductors Xlpo Jacket 600V
Control Cable Fr-XLPE Insulated Copper Conductors 600V 12AWG
Popular yifangcable Products
18/30kv (36KV) Power Cable Aluminum Conductor PVC Sheath 3X400mm2
All Aluminum Alloy Stranded AAAC Conductor
600/1000V, Power Cable, Single Core, XLPE Insulated, PVC Sheathed, 1X185mm2
6kv 3X240mm2 XLPE Steel Armored Underground Cable
BS 215 Bare Conductor Cable AAC ACSR AAAC Overhead Line Conductor
Tags: Control Cable, Copper Conductor, Fr-XLPE Insulated, yifangcable