Copper Conductor Cu XLPE Sta PVC Galvanized Steel Tape Armoured Cable N2xby
Copper Conductor Cu XLPE Sta PVC Galvanized Steel Tape Armoured Cable N2xby image
Get Latest Price Request a quote
- Overview
- Product Description
Basic Info.
Product Description
N2XBY cable is suitable for AC 50Hz power and distribution lines with rated voltage of 0.6/1kV, which can be used in fixed industrial power applications, underground tunnels, etc. Using steel wire armour offers great mechanical protection, making it rigid with a large radius.
Specifications
IEC 60228 Conductors
IEC 60502-1 Power cables with extruded insulation and their accessories for rated voltages from 1kV(Um=1.2kV) up to 35kV(Um=40.5kV) – Part 1: Cables for rated voltages of 1 kV(Um=1.2kV) and 3 kV(Um=3.6kV)
Cable Construction
Single Core Cable
1. Conductor: Copper or aluminum, Class 1: solid conductor, or Class 2: stranded conductor
2. Insulation: Polietileno reticulado XLPE
3. Inner sheath: Polyvinyl chloride PVC
4. Armour: Non-magnetic steel-tape
5. Outer sheath: Polyvinyl chloride PVC
Multi Core Cable
2. Insulation: crosslinked polyethylene XLPE
3. Filler: Non-hygroscopic material
4. Binder tape: Non-hygroscopic material
5. Inner sheath: Polyvinyl chloride PVC
6. Armour: Steel-tape
7. Outer sheath: Polyvinyl chloride PVC
| 0.6/1kV-1 core copper conductor XLPE insulated steel tape armored PVC sheathed power cable | ||||||||
| Nominal cross sectional area | Insulation thickness | Non-magnetic steel tape thickness | Sheath thickness | Approximate outer diameter | Approx. weight |
Max.D.C resistance of conductor(20ºC) | Current carrying capacity | |
| mm2 | mm | mm | mm | mm | kg/km | Ω/km | In Air(A) | In Ground(A) |
| 1X10 | 0.7 | 0.2 | 1.8 | 11.8 | 244.0 | 1.83 | 75 | 47 |
| 1X16 | 0.7 | 0.2 | 1.8 | 12.9 | 318.0 | 1.15 | 97 | 62 |
| 1X25 | 0.9 | 0.2 | 1.8 | 14.6 | 430.0 | 0.727 | 125 | 78 |
| 1X35 | 0.9 | 0.2 | 1.8 | 15.2 | 533.0 | 0.524 | 155 | 94 |
| 1X50 | 1.0 | 0.2 | 1.8 | 16.7 | 668.0 | 0.387 | 190 | 110 |
| 1X70 | 1.1 | 0.2 | 1.8 | 18.5 | 893.0 | 0.268 | 245 | 135 |
| 1X95 | 1.1 | 0.2 | 1.8 | 20.1 | 1157.0 | 0.193 | 300 | 160 |
| 1X120 | 1.2 | 0.2 | 1.8 | 21.7 | 1410.0 | 0.153 | 350 | 185 |
| 1X150 | 1.4 | 0.2 | 1.8 | 23.7 | 1705.0 | 0.124 | 400 | 205 |
| 1X185 | 1.6 | 0.2 | 1.8 | 25.7 | 2082.0 | 0.0991 | 460 | 235 |
| 1X240 | 1.7 | 0.2 | 1.8 | 28.0 | 2652.0 | 0.0754 | – | – |
| 1X300 | 1.8 | 0.2 | 1.9 | 31.0 | 3259.0 | 0.0601 | – | – |
| 1X400 | 2.0 | 0.2 | 2.0 | 35.0 | 4135.0 | 0.047 | – | – |
| 0.6/1kV-2 core copper conductor XLPE insulated steel tape armored PVC sheathed power cable | ||||||||
| Nominal cross sectional area | Insulation thickness | Non-magnetic steel tape thickness | Sheath thickness | Approximate outer diameter | Approx. weight |
Max. D.C resistance of conductor(20ºC) | Current carrying capacity | |
| mm2 | mm | mm | mm | mm | kg/km | Ω/km | In Air(A) | In Ground(A) |
| 2X2.5 | 0.7 | 0.2 | 1.8 | 13.4 | 230 | 7.41 | – | 45 |
| 2X4 | 0.7 | 0.2 | 1.8 | 14.3 | 277 | 4.61 | – | 59 |
| 2X6 | 0.7 | 0.2 | 1.8 | 15.3 | 336 | 3.08 | – | 74 |
| 2X10 | 0.7 | 0.2 | 1.8 | 17.8 | 452 | 1.83 | 64 | 100 |
| 2X16 | 0.7 | 0.2 | 1.8 | 20.0 | 609 | 1.15 | 83 | 135 |
| 2X25 | 0.9 | 0.2 | 1.8 | 23.3 | 845 | 0.727 | 110 | 165 |
| 2X35 | 0.9 | 0.2 | 1.8 | 24.6 | 1065 | 0.524 | 135 | 200 |
| 2X50 | 1.0 | 0.2 | 1.8 | 27.2 | 1297 | 0.387 | 165 | 240 |
| 2X70 | 1.1 | 0.2 | 1.9 | 31.4 | 1775 | 0.268 | 210 | 295 |
| 2X95 | 1.1 | 0.2 | 2.0 | 35.5 | 2340 | 0.193 | 260 | 355 |
| 2X120 | 1.2 | 0.5 | 2.2 | 40.2 | 3238 | 0.153 | 305 | 405 |
| 2X150 | 1.4 | 0.5 | 2.3 | 44.2 | 3971 | 0.124 | 345 | 455 |
| 2X185 | 1.6 | 0.5 | 2.5 | 48.9 | 4845 | 0.0991 | 396 | 515 |
| 0.6/1kV-3 core copper conductor XLPE insulated steel tape armored PVC sheathed power cable | ||||||||
| Nominal cross sectional area | Insulation thickness | Non-magnetic steel tape thickness | Sheath thickness | Approximate outer diameter | Approx. weight |
Max.D.C resistance of conductor(20ºC) | Current carrying capacity | |
| mm2 | mm | mm | mm | mm | kg/km | Ω/km | In Air(A) | In Ground(A) |
| 3X2.5 | 0.7 | 0.2 | 1.8 | 13.9 | 265 | 7.41 | – | 35 |
| 3X4 | 0.7 | 0.2 | 1.8 | 14.8 | 328 | 4.61 | – | 50 |
| 3X6 | 0.7 | 0.2 | 1.8 | 16.0 | 410 | 3.08 | – | 60 |
| 3X10 | 0.7 | 0.2 | 1.8 | 18.6 | 560 | 1.83 | 64 | 85 |
| 3X16 | 0.9 | 0.2 | 1.8 | 21.0 | 775 | 1.15 | 83 | 110 |
| 3X25 | 0.9 | 0.2 | 1.8 | 24.6 | 1098 | 0.727 | 110 | 140 |
| 3X35 | 0.9 | 0.2 | 1.8 | 26.0 | 1410 | 0.524 | 135 | 170 |
| 3X50 | 1.0 | 0.2 | 1.9 | 28.9 | 1780 | 0.387 | 165 | 200 |
| 3X70 | 1.1 | 0.2 | 2.0 | 33.9 | 2475 | 0.268 | 210 | 245 |
| 3X95 | 1.1 | 0.5 | 2.2 | 39.0 | 3260 | 0.193 | 260 | 300 |
| 3X120 | 1.2 | 0.5 | 2.3 | 42.7 | 4477 | 0.153 | 305 | 335 |
| 3X150 | 1.4 | 0.5 | 2.4 | 47.5 | 5440 | 0.124 | 345 | 380 |
| 3X185 | 1.6 | 0.5 | 2.6 | 52.1 | 6707 | 0.0991 | 395 | 430 |
| 3X240 | 1.7 | 0.5 | 2.8 | 58.3 | 8533 | 0.0754 | 465 | 500 |
| 3X300 | 1.8 | 0.5 | 2.9 | 63.6 | 10455 | 0.0601 | 535 | 565 |
| 0.6/1kV-4 core copper conductor XLPE insulated steel tape armored PVC sheathed power cable | ||||||||
| Nominal cross sectional area | Insulation thickness | Non-magnetic steel tape thickness | Sheath thickness | Approximate outer diameter | Approx. weight |
Max.D.C resistance of conductor(20ºC) | Current carrying capacity | |
| mm2 | mm | mm | mm | mm | kg/km | Ω/km | In Air(A) | In Ground(A) |
| 4X2.5 | 0.7 | 0.2 | 1.8 | 14.7 | 308 | 7.41 | – | 35 |
| 4X4 | 0.7 | 0.2 | 1.8 | 15.8 | 388 | 4.61 | – | 50 |
| 4X6 | 0.7 | 0.2 | 1.8 | 17.0 | 488 | 3.08 | – | 60 |
| 4X10 | 0.7 | 0.2 | 1.8 | 20.0 | 681 | 1.83 | 64 | 85 |
| 4X16 | 0.9 | 0.2 | 1.8 | 22.7 | 960 | 1.15 | 83 | 110 |
| 4X25 | 0.9 | 0.2 | 1.8 | 26.7 | 1375 | 0.727 | 110 | 140 |
| 4X35 | 0.9 | 0.2 | 1.8 | 28.3 | 1779 | 0.524 | 135 | 170 |
| 4X50 | 1.0 | 0.2 | 2.1 | 32.0 | 2296 | 0.387 | 165 | 200 |
| 4X70 | 1.1 | 0.5 | 2.1 | 38.5 | 3175 | 0.268 | 210 | 245 |
| 4X95 | 1.1 | 0.5 | 2.3 | 42.9 | 4665 | 0.193 | 260 | 300 |
| 4X120 | 1.2 | 0.5 | 2.4 | 47.4 | 5728 | 0.153 | 305 | 335 |
| 4X150 | 1.4 | 0.5 | 2.6 | 52.3 | 6999 | 0.124 | 345 | 380 |
| 4X185 | 1.6 | 0.5 | 2.7 | 57.5 | 8657 | 0.0991 | 395 | 430 |
| 4X240 | 1.7 | 0.5 | 3.0 | 64.3 | 11000 | 0.0754 | 465 | 500 |
| 4X300 | 1.8 | 0.5 | 3.1 | 70.3 | 13587 | 0.0601 | 535 | 565 |
| 0.6/1kV-5 core copper conductor XLPE insulated steel tape armored PVC sheathed power cable | ||||||||
| Nominal cross sectional area | Insulation thickness | Non-magnetic steel tape thickness | Sheath thickness | Approximate outer diameter | Approx. weight |
Max.D.C resistance of conductor(20ºC) | Current carrying capacity | |
| mm2 | mm | mm | mm | mm | kg/km | Ω/km | In Air(A) | In Ground(A) |
| 5X2.5 | 0.7 | 0.2 | 1.8 | 15.6 | 350 | 7.41 | – | 35 |
| 5X4 | 0.7 | 0.2 | 1.8 | 16.8 | 447 | 4.61 | – | 50 |
| 5X6 | 0.7 | 0.2 | 1.8 | 18.2 | 569 | 3.08 | – | 60 |
| 5X10 | 0.7 | 0.2 | 1.8 | 21.6 | 805 | 1.83 | 64 | 85 |
| 5X16 | 0.7 | 0.2 | 1.8 | 24.6 | 1150 | 1.15 | 83 | 110 |
| 5X25 | 0.9 | 0.2 | 1.8 | 29.0 | 1655 | 0.727 | 110 | 140 |
| 5X35 | 0.9 | 0.2 | 1.9 | 31.0 | 2166 | 0.524 | 135 | 170 |
| 5X50 | 1.0 | 0.2 | 2.1 | 35.7 | 2945 | 0.387 | 165 | 200 |
| 5X70 | 1.1 | 0.5 | 2.3 | 42.4 | 4453 | 0.268 | 210 | 245 |
| 5X95 | 1.1 | 0.5 | 2.4 | 47.2 | 5862 | 0.193 | 260 | 300 |
| 5X120 | 1.2 | 0.5 | 2.6 | 51.8 | 7176 | 0.153 | 305 | 335 |
| 5X150 | 1.4 | 0.5 | 2.7 | 57.6 | 8770 | 0.124 | 345 | 380 |
| 5X185 | 1.6 | 0.5 | 2.9 | 63.8 | 10827 | 0.0991 | 395 | 430 |
| 5X240 | 1.7 | 0.5 | 3.2 | 70.7 | 13770 | 0.0754 | 465 | 500 |
| 5X300 | 1.8 | 0.5 | 3.4 | 78.0 | 16960 | 0.0601 | 535 | 565 |
| 0.6/1kV-3+1 core copper conductor XLPE insulated steel tape armored PVC sheathed power cable | ||||||||
| Nominal cross sectional area | Insulation thickness | Non-magnetic steel tape thickness | Sheath thickness | Approximate outer diameter | Approx. weight |
Max.D.C resistance of conductor(20ºC) | Current carrying capacity | |
| mm2 | mm | mm | mm | mm | kg/km | Ω/km | In Air(A) | In Ground(A) |
| 3X4+1X2.5 | 0.7/0.7 | 0.2 | 1.8 | 15.5 | 368 | 4.61/7.41 | – | 50 |
| 3X6+1X4 | 0.7/0.7 | 0.2 | 1.8 | 16.8 | 465 | 3.08/4.61 | – | 60 |
| 3X10+1X6 | 0.7/0.7 | 0.2 | 1.8 | 19.3 | 633 | 1.83/3.08 | 64 | 85 |
| 3X16+1X10 | 0.7/0.7 | 0.2 | 1.8 | 22.1 | 890 | 1.15/1.83 | 83 | 110 |
| 3X25+1X16 | 0.9/0.7 | 0.2 | 1.8 | 25.1 | 1272 | 0.727/1.15 | 110 | 140 |
| 3X35+1X16 | 0.9/0.7 | 0.2 | 1.8 | 26.8 | 1583 | 0.524/1.15 | 135 | 170 |
| 3X50+1X25 | 1/0.9 | 0.2 | 1.9 | 30.2 | 2030 | 0.387/0.727 | 165 | 200 |
| 3X70+1X35 | 1.1/0.9 | 0.2 | 2.0 | 35.1 | 2810 | 0.268/0.524 | 210 | 245 |
| 3X95+1X50 | 1.1/1.0 | 0.5 | 2.2 | 40.4 | 4135 | 0.193/0.387 | 260 | 300 |
| 3X120+1X70 | 1.2/1.1 | 0.5 | 2.3 | 45 | 5135 | 0.153/0.268 | 305 | 335 |
| 3X150+1X70 | 1.4/1.1 | 0.5 | 2.5 | 49.1 | 6120 | 0.124/0.268 | 345 | 380 |
| 3X185+1X95 | 1.6/1.1 | 0.5 | 2.8 | 54.3 | 7616 | 0.0991/0.193 | 395 | 430 |
| 3X240+1X120 | 1.7/1.2 | 0.5 | 2.8 | 59.1 | 9679 | 0.0754/0.153 | 465 | 500 |
| 3X300+1X150 | 1.8/1.4 | 0.5 | 3.0 | 66 | 11889 | 0.0601/0.124 | 535 | 565 |
| 0.6/1kV-4+1 core copper conductor XLPE insulated steel tape armored PVC sheathed power cable | ||||||||
| Nominal cross sectional area | Insulation thickness | Non-magnetic steel tape thickness | Sheath thickness | Approximate outer diameter | Approx. weight |
Max.D.C resistance of conductor(20ºC) | Current carrying capacity | |
| mm2 | mm | mm | mm | mm | kg/km | Ω/km | In Air(A) | In Ground(A) |
| 4X4+1X2.5 | 0.7/0.7 | 0.2 | 1.8 | 16.3 | 434 | 4.61/7.41 | – | 50 |
| 4X6+1X4 | 0.7/0.7 | 0.2 | 1.8 | 17.7 | 549 | 3.08/4.61 | – | 60 |
| 4X10+1X6 | 0.7/0.7 | 0.2 | 1.8 | 20.3 | 759 | 1.83/3.08 | 64 | 85 |
| 4X16+1X10 | 0.7/0.7 | 0.2 | 1.8 | 24 | 1079 | 1.15/1.83 | 83 | 110 |
| 4X25+1X16 | 0.9/0.7 | 0.2 | 1.8 | 28.1 | 1557 | 0.727/1.15 | 110 | 140 |
| 4X35+1X16 | 0.9/0.7 | 0.2 | 1.9 | 29.6 | 1962 | 0.524/1.15 | 135 | 170 |
| 4X50+1X25 | 1/0.9 | 0.2 | 2.0 | 34 | 2601 | 0.387/0.727 | 165 | 200 |
| 4X70+1X35 | 1.1/0.9 | 0.5 | 2.2 | 40.3 | 3916 | 0.268/0.524 | 210 | 245 |
| 4X95+1X50 | 1.1/1.0 | 0.5 | 2.3 | 44.8 | 5260 | 0.193/0.387 | 260 | 300 |
| 4X120+1X70 | 1.2/1.1 | 0.5 | 2.6 | 50.2 | 6545 | 0.153/0.268 | 305 | 335 |
| 4X150+1X70 | 1.4/1.1 | 0.5 | 2.8 | 54.6 | 7780 | 0.124/0.268 | 345 | 380 |
| 4X185+1X95 | 1.6/1.1 | 0.5 | 2.9 | 60.5 | 9688 | 0.0991/0.193 | 395 | 430 |
| 4X240+1X120 | 1.7/1.2 | 0.5 | 3.0 | 67.1 | 12253 | 0.0754/0.153 | 465 | 500 |
| 4X300+1X150 | 1.8/1.4 | 0.5 | 3.2 | 73.7 | 15078 | 0.0601/0.124 | 535 | 565 |
| 0.6/1kV-3+2 core copper conductor XLPE insulated steel tape armored PVC sheathed power cable | ||||||||
| Nominal cross sectional area | Insulation thickness | Non-magnetic steel tape thickness | Sheath thickness | Approximate outer diameter | Approx. weight |
Max.D.C resistance of conductor(20ºC) | Current carrying capacity | |
| mm2 | mm | mm | mm | mm | kg/km | Ω/km | In Air(A) | In Ground(A) |
| 3X4+2X2.5 | 0.7/0.7 | 0.2 | 1.8 | 16.6 | 412 | 4.61/7.41 | – | 50 |
| 3X6+2X4 | 0.7/0.7 | 0.2 | 1.8 | 18 | 525 | 3.08/4.61 | – | 60 |
| 3X10+2X6 | 0.7/0.7 | 0.2 | 1.8 | 20.9 | 714 | 1.83/3.08 | 64 | 85 |
| 3X16+2X10 | 0.7/0.7 | 0.2 | 1.8 | 24 | 1016 | 1.15/1.83 | 83 | 110 |
| 3X25+2X16 | 0.9/0.7 | 0.2 | 1.8 | 28.1 | 1465 | 0.727/1.15 | 110 | 140 |
| 3X35+2X16 | 0.9/0.7 | 0.2 | 1.9 | 29.6 | 1769 | 0.524/1.15 | 135 | 170 |
| 3X50+2X25 | 1/0.9 | 0.2 | 2.0 | 34 | 2316 | 0.387/0.727 | 165 | 200 |
| 3X70+2X35 | 1.1/0.9 | 0.5 | 2.2 | 40.3 | 3230 | 0.268/0.524 | 210 | 245 |
| 3X95+2X50 | 1.1/1.0 | 0.5 | 2.3 | 44.8 | 4766 | 0.193/0.387 | 260 | 300 |
| 3X120+2X70 | 1.2/1.1 | 0.5 | 2.5 | 50.2 | 6080 | 0.153/0.268 | 305 | 335 |
| 3X150+2X70 | 1.4/1.1 | 0.5 | 2.6 | 54.6 | 7005 | 0.124/0.268 | 345 | 380 |
| 3X185+2X95 | 1.6/1.1 | 0.5 | 2.8 | 60.5 | 8767 | 0.0991/0.193 | 395 | 430 |
| 3X240+2X120 | 1.7/1.2 | 0.5 | 3.0 | 67.1 | 11105 | 0.0754/0.153 | 465 | 500 |
| 3X300+2X150 | 1.8/1.4 | 0.5 | 3.2 | 73.7 | 13645 | 0.0601/0.124 | 535 | 565 |
Packing shipping
Packing
Steel wooden drum (fumigation)
Cable length in each drum: 1000m/2000m or as per actual cable length requirements.
Drum size:
As per cable length and container size
*In order to quote you accurate price, kindly tell us your needed cable length quantity. Larger quantity, more discount benefit ready for you!
Shipping Port:
Tianjin, Qingdao, or other ports as per your requireents.
Sea freight:
FOB/C&F/CIF quotation are all available.
*For some countries such as Africa countries, middle east countries, our sea freight quotation is much cheaper than clients get from local shipping agency.
Any problem and inquiry pls contact with Tina
We are China Copper Conductor Cu XLPE Sta PVC Galvanized Steel Tape Armoured Cable N2xby manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Cable N2xby Products
IEC 60502-1 Cu/XLPE/Sta/PVC Galvanized Steel Tape Armoured N2xby Cable
IEC 60502-1 N2xby Power Cable 0.6/1 Kv Cu/XLPE/PVC/ATA/PVC
Popular Copper Conductor Cu XLPE Sta PVC Galvanized Steel Tape Armoured Cable N2xby Products
Popular N2xby Cable Products
IEC 60502-1 N2xby Power Cable 0.6/1 Kv Cu/XLPE/PVC/ATA/PVC
0.6/1kv N2xby Cable, Armoured Cable with CE Certificate
Na2xby N2xby Aluminium Conductor IEC60502-1 XLPE Dsta PVC 0.6/1kv Cable
IEC 60502-1 Cu/XLPE/Sta/PVC Galvanized Steel Tape Armoured N2xby Cable
0.6/1kv Low Voltage N2xby Electric Cable
0.6/1kv N2xby Electrical Cable Low Voltage LV N2xby Electric Cable
Popular zzhongdacable Products
Torsade Cable NFC33209 ABC Aerial Bundle Cable 3X70+1X54, 6+1X16mm2
XLPE Flexible Copper Cable Superflex 500mcm 350mcm 300mcm 250mcm 4/0AWG
Aster 54.6mm2 AAAC Almelec Bare Conductor Al4
0.6-25kv SABS Approved XLPE ABC Cable Overhead Cable Electric Wires
0.6/1kv PVC Insulated PVC Sheathed Waterproof Electrical Cable
600V 3*120+3*16mm Flexible Rubber PVC Frequency Converter VFD Shield Power Electric Cable
Tags: Cable N2xby, Copper Conductor Cu XLPE Sta PVC Galvanized Steel Tape Armoured Cable N2xby, N2xby Cable, zzhongdacable