Copper Conductor PVC Insulated Underground Power Cable
Copper Conductor PVC Insulated Underground Power Cable image
Get Latest Price Request a quote
- Overview
- Product Description
- Product Parameters
- Company Profile
Basic Info.
Packaging & Delivery
Product Description
Application:
With the characteristics of stable capability,advanced technology,broad material resources,low price, good flexible and easy to lay and maintain, the PVC Insulated and Sheathed Power Cable are suitable to be laid for distribution line with A.C.50HZ and rated voltage up to 6kV.
Property:
1.The long-time permissible working temperature of cable conductive core is not more than 70 °C.
2.During short circuit (max. permanent time is not more than 5 seconds), the max temperature of cable conductor is not more than 165°C.
3.The difference level of laying cable is not restricted.When laying the cable,ambient temperature is not lower than 0°C.
4.They have good chemical stability,and properties of acid resistance,alkali resistance,salt resistance,oil resistance,solvent resistance and flame resistance.rty
5.Light weight,good bending property and easy installation and maintenance.
Specification:
Standard:
IEC,BS,VDE,AS/NZS,ICEA,JIS and so on,designing and manufacturing special power cable according to the other standards required by the customer
1)600/1000V, Single Core, Circular Compacted Al or Cu/PVC/PVC Unarmoured or Armoured Power Cable
|
Cross Section of Conductor |
No. of Wires |
Thickness of Insulation |
Unarmoured |
Armoured |
||||||||
|
Thickness of Sheath |
Overall Dia. |
jpcable99.en. Weight |
Thickness of Bedding |
Thickness of Al Tape |
Thickness of Sheath |
Overall Dia. |
jpcable99.en. Weight |
|||||
|
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
|||||||||
|
mm2 |
– |
mm |
mm |
mm |
kg/km |
kg/km |
mm |
mm |
mm |
mm |
kg/km |
kg/km |
|
1.5 |
1 |
0.8 |
1.4 |
5.8 |
– |
51 |
– |
– |
– |
– |
– |
– |
|
2.5 |
1 |
0.8 |
1.4 |
6.2 |
– |
64 |
– |
– |
– |
– |
– |
– |
|
4 |
1 |
1 |
1.4 |
7.1 |
– |
88 |
– |
– |
– |
– |
– |
– |
|
6 |
7 |
1 |
1.4 |
7.8 |
78 |
114 |
– |
– |
– |
– |
– |
– |
|
10 |
7 |
1 |
1.4 |
8.6 |
96 |
159 |
1 |
0.5 |
1.8 |
13.4 |
234 |
295 |
|
16 |
7 |
1 |
1.4 |
9.6 |
123 |
222 |
1 |
0.5 |
1.8 |
14.4 |
274 |
370 |
|
25 |
7 |
1.2 |
1.4 |
11.2 |
172 |
328 |
1 |
0.5 |
1.8 |
16 |
344 |
496 |
|
35 |
7 |
1.2 |
1.4 |
12.2 |
209 |
428 |
1 |
0.5 |
1.8 |
17 |
393 |
606 |
|
50 |
19 |
1.4 |
1.4 |
13.9 |
271 |
565 |
1 |
0.5 |
1.8 |
18.7 |
478 |
764 |
|
70 |
19 |
1.4 |
1.5 |
15.9 |
356 |
818 |
1 |
0.5 |
1.8 |
20.5 |
582 |
1020 |
|
95 |
19 |
1.6 |
1.5 |
18 |
471 |
1041 |
1 |
0.5 |
1.8 |
22.6 |
717 |
1291 |
|
120 |
37 |
1.6 |
1.6 |
19.6 |
563 |
1307 |
1 |
0.5 |
1.8 |
24 |
822 |
1545 |
|
150 |
37 |
1.8 |
1.6 |
21.3 |
684 |
1592 |
1 |
0.5 |
1.8 |
25.4 |
952 |
1857 |
|
185 |
37 |
2 |
1.7 |
23.9 |
840 |
1985 |
1 |
0.5 |
1.8 |
27.9 |
1136 |
2236 |
|
240 |
61 |
2.2 |
1.8 |
27 |
1071 |
2533 |
1 |
0.5 |
1.9 |
31 |
1404 |
2877 |
|
300 |
61 |
2.4 |
1.9 |
29.6 |
1317 |
3162 |
1.2 |
0.5 |
2.1 |
34.3 |
1722 |
3551 |
|
400 |
61 |
2.6 |
2 |
33.2 |
1666 |
4120 |
1.2 |
0.5 |
2.2 |
37.6 |
2114 |
4488 |
|
500 |
61 |
2.8 |
2.2 |
37.5 |
2089 |
5163 |
1.2 |
0.5 |
2.3 |
42.1 |
2592 |
5683 |
|
630 |
61 |
2.8 |
2.3 |
41.2 |
2581 |
6447 |
1.4 |
0.5 |
2.4 |
46.3 |
3184 |
7060 |
2)600/1000V, Multi Cores, Sectoral Compacted Al or Cu/PVC/PVC Unarmoured Power Cable
|
Number of Cores |
Cross-Section of Conductor |
No. Of Wires |
Thickness of Insulation |
Thickness of Sheath |
Overall Diameter |
Approx. Net Weight |
|
|
Al Conductor |
Cu Conductor |
||||||
|
– |
mm2 |
– |
mm |
mm |
mm |
kg/km |
kg/km |
|
Three Cores |
3×35 |
16 |
1.2 |
1.8 |
21.9 |
601 |
1280 |
|
3×50 |
18 |
1.4 |
1.8 |
26.5 |
829 |
1732 |
|
|
3×70 |
18 |
1.4 |
1.9 |
29.2 |
1067 |
2367 |
|
|
3×95 |
36 |
1.6 |
2 |
32.9 |
1409 |
2317 |
|
|
3×120 |
36 |
1.6 |
2.1 |
36.2 |
1705 |
3983 |
|
|
3×150 |
36 |
1.8 |
2.2 |
38.8 |
2045 |
4872 |
|
|
3×185 |
36 |
2 |
2.4 |
44.8 |
2596 |
6077 |
|
|
3×240 |
60 |
2.2 |
2.6 |
51.5 |
3353 |
7953 |
|
|
3×300 |
60 |
2.4 |
2.7 |
54.9 |
6069 |
9820 |
|
|
Four Cores with Reduced Neutral |
3×35+16 |
16-7 |
1.2-1 |
1.8 |
25.5 |
764 |
1107 |
|
3×50+25 |
18-16 |
1.4-1.2 |
1.9 |
28.7 |
982 |
1410 |
|
|
3×70+35 |
18-16 |
1.4-1.2 |
2.0 |
32 |
1278 |
1733 |
|
|
3×95+50 |
36-18 |
1.6-1.4 |
2.2 |
37.8 |
1711 |
2656 |
|
|
3×120+70 |
36-18 |
1.6-1.4 |
2.3 |
40.5 |
2065 |
3137 |
|
|
3×150+70 |
36-18 |
1.8-1.4 |
2.4 |
44.8 |
2480 |
3660 |
|
|
3×185+95 |
36-36 |
2-1.6 |
2.6 |
49.7 |
3086 |
4345 |
|
|
3×240+120 |
60-36 |
2.2-1.6 |
2.8 |
56 |
3894 |
5441 |
|
|
3×300+150 |
60-36 |
1.4-1.8 |
2.9 |
60.3 |
4834 |
6494 |
|
|
Four Cores |
4×25 |
16 |
1.2 |
1.8 |
22.5 |
644 |
1286 |
|
4×35 |
16 |
1.2 |
1.8 |
24.6 |
799 |
1696 |
|
|
4×50 |
18 |
1.4 |
1.8 |
28.6 |
1071 |
2275 |
|
|
4×70 |
18 |
1.4 |
2 |
31.6 |
1387 |
3120 |
|
|
4×95 |
36 |
1.6 |
2.1 |
35.9 |
1850 |
4262 |
|
|
4×120 |
36 |
1.6 |
2.2 |
38.8 |
2209 |
5247 |
|
|
4×150 |
36 |
1.8 |
2.3 |
43.1 |
2714 |
6483 |
|
|
4×185 |
36 |
2 |
2.5 |
48.7 |
3403 |
8045 |
|
|
4×240 |
60 |
2.2 |
2.7 |
53.6 |
4290 |
10422 |
|
|
4×300 |
60 |
2.4 |
2.9 |
58.8 |
5302 |
12969 |
|
3)600/1000V, Multi Cores, Circular Compacted Al or Cu/PVC/PVC Unarmoured Power Cable
|
Number of Cores |
Cross-Section of Conductor |
No. Of Wires |
Thickness of Insulation |
Thickness of Sheath |
Overall Diameter |
Approx. Net Weight |
||
|
Al Conductor |
Cu Conductor |
|||||||
|
– |
mm2 |
– |
mm |
mm |
mm |
kg/km |
kg/km |
|
|
Three Cores |
3×10 |
7 |
1 |
1.8 |
16.6 |
281 |
465 |
|
|
3×16 |
7 |
1 |
1.8 |
18.7 |
387 |
679 |
||
|
3×25 |
7 |
1.2 |
1.8 |
22.2 |
536 |
996 |
||
|
3×35 |
7 |
1.2 |
1.8 |
24.4 |
665 |
1311 |
||
|
3×50 |
19 |
1.4 |
1.9 |
28.1 |
863 |
1729 |
||
|
3×70 |
19 |
1.4 |
2 |
32.3 |
1153 |
2480 |
||
|
3×95 |
19 |
1.6 |
2.1 |
37.1 |
1563 |
3301 |
||
|
3×120 |
37 |
1.6 |
2.3 |
40.4 |
1850 |
4040 |
||
|
3×150 |
37 |
1.8 |
2.4 |
43.9 |
2258 |
5000 |
||
|
3×185 |
37 |
2 |
2.5 |
49.2 |
2819 |
6151 |
||
|
3×240 |
61 |
2.2 |
2.8 |
55.9 |
3577 |
8040 |
||
|
3×300 |
61 |
2.4 |
3 |
62.1 |
4413 |
9955 |
||
|
3×400 |
61 |
2.6 |
3.2 |
69.3 |
5512 |
12705 |
||
|
Four Cores |
4×10 |
7 |
1 |
1.8 |
18.1 |
343 |
589 |
|
|
4×16 |
7 |
1 |
1.8 |
20.5 |
487 |
874 |
||
|
4×25 |
7 |
1.2 |
1.8 |
24.3 |
677 |
1291 |
||
|
4×35 |
7 |
1.2 |
1.8 |
26.8 |
821 |
1681 |
||
|
4×50 |
19 |
1.4 |
2 |
31.2 |
1118 |
2273 |
||
|
4×70 |
19 |
1.4 |
2.1 |
35.8 |
1494 |
3264 |
||
|
4×95 |
19 |
1.6 |
2.3 |
41.2 |
1993 |
4312 |
||
|
4×120 |
37 |
1.6 |
2.4 |
44.8 |
2370 |
5291 |
||
|
4×150 |
37 |
1.8 |
2.5 |
48.7 |
2959 |
6615 |
||
|
4×185 |
37 |
2 |
2.7 |
54.7 |
3601 |
8044 |
||
|
4×240 |
61 |
2.2 |
3 |
62.1 |
4596 |
10547 |
||
|
4×300 |
61 |
2.4 |
3.2 |
69.1 |
5614 |
13004 |
||
4)600/1000V, Multi Cores, Sectoral Compacted Al or Cu/PVC/PVC Armoured Power Cable
|
Cross Section of Conductor |
No. of Wires |
Thickness of Insulation |
Thickness of Inner Sheath |
Thickness of Steel Tape |
No./Dia. Of Steel Wires |
Thickness of Sheath |
Overall Diameter |
Approx. Net Weight |
||||||
|
STA |
SWA |
|||||||||||||
|
STA |
SWA |
STA |
SWA |
STA |
SWA |
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
|||||
|
mm2 |
– |
mm |
mm |
mm |
No./mm |
mm |
mm |
mm |
mm |
kg/km |
kg/km |
kg/km |
kg/km |
|
|
Three Cores |
||||||||||||||
|
3×35 |
16 |
1.2 |
1 |
0.2 |
38/1.6 |
1.8 |
1.9 |
24.7 |
28.2 |
912 |
1591 |
1447 |
2126 |
|
|
3×50 |
18 |
1.4 |
1 |
0.2 |
46/1.6 |
1.9 |
2 |
29.3 |
32.8 |
1202 |
2105 |
1842 |
2745 |
|
|
3×70 |
18 |
1.4 |
1.2 |
0.2 |
41/2.0 |
2.0 |
2.2 |
32.5 |
37.1 |
1520 |
2820 |
2475 |
3775 |
|
|
3×95 |
36 |
1.6 |
1.2 |
0.5 |
46/2.0 |
2.1 |
2.3 |
36.5 |
40.8 |
2241 |
4049 |
2989 |
4797 |
|
|
3×120 |
36 |
1.6 |
1.2 |
0.5 |
50/2.0 |
2.2 |
2.4 |
39.8 |
44.1 |
2617 |
4895 |
3435 |
5713 |
|
|
3×150 |
36 |
1.8 |
1.2 |
0.5 |
43/2.5 |
2.3 |
2.5 |
42.4 |
47.8 |
3019 |
5846 |
4258 |
7085 |
|
|
3×185 |
36 |
2 |
1.4 |
0.5 |
50/2.5 |
2.5 |
2.7 |
48.8 |
54.2 |
3783 |
7264 |
5219 |
8700 |
|
|
3×240 |
60 |
2.2 |
1.6 |
0.5 |
58/2.5 |
2.8 |
2.9 |
56 |
61.3 |
4790 |
9390 |
6444 |
11044 |
|
|
3×300 |
60 |
2.4 |
1.6 |
0.5 |
61/2.5 |
2.9 |
3.1 |
59.3 |
64.7 |
5594 |
11345 |
7458 |
13209 |
|
|
Four Cores with Reduced Neutral |
||||||||||||||
|
3×35+16 |
16-7 |
1.2-1 |
1 |
0.2 |
43/1.6 |
1.9 |
2 |
28.5 |
31.3 |
1107 |
1528 |
1705 |
2469 |
|
|
3×50+25 |
18-16 |
1.4-1.2 |
1.2 |
0.2 |
40/2.0 |
2.0 |
2.1 |
32.2 |
36.1 |
1410 |
2044 |
2326 |
3388 |
|
|
3×70+35 |
18-16 |
1.4-1.2 |
1.2 |
0.2 |
44/2.0 |
2.0 |
2.2 |
35.2 |
39.3 |
1733 |
2801 |
2762 |
4285 |
|
|
3×95+50 |
36-18 |
1.6-1.4 |
1.2 |
0.5 |
41/2.5 |
2.3 |
2.5 |
42.5 |
46.3 |
2656 |
3820 |
3816 |
5925 |
|
|
3×120+70 |
36-18 |
1.6-1.4 |
1.4 |
0.5 |
45/2.5 |
2.4 |
2.6 |
45.6 |
49.4 |
3137 |
4777 |
4391 |
7103 |
|
|
3×150+70 |
36-18 |
1.8-1.4 |
1.4 |
0.5 |
49/2.5 |
2.6 |
2.7 |
49.9 |
53.6 |
3660 |
5709 |
5043 |
8272 |
|
|
3×185+95 |
36-36 |
2-1.6 |
1.4 |
0.5 |
55/2.5 |
2.6 |
2.9 |
54.5 |
58.5 |
3445 |
7171 |
5902 |
9987 |
|
|
3×240+120 |
60-36 |
2.2-1.6 |
1.6 |
0.5 |
62/2.5 |
2.9 |
3.1 |
61.6 |
65.3 |
5441 |
9272 |
7174 |
12552 |
|
|
3×300+150 |
60-36 |
1.4-1.8 |
1.6 |
0.5 |
67/2.5 |
3.8 |
3.2 |
65.9 |
69.6 |
6494 |
11546 |
8355 |
15067 |
|
|
Four Cores |
||||||||||||||
|
4×25 |
16 |
1.2 |
1 |
0.2 |
38/1.6 |
1.8 |
1.9 |
25.3 |
28 |
934 |
1576 |
1450 |
2092 |
|
|
4×35 |
16 |
1.2 |
1 |
0.2 |
41/1.6 |
1.8 |
1.9 |
27.4 |
30.2 |
1120 |
2017 |
1681 |
2578 |
|
|
4×50 |
18 |
1.4 |
1 |
0.2 |
39/2.0 |
2 |
2.1 |
31.6 |
35.6 |
1454 |
2658 |
2336 |
3540 |
|
|
4×70 |
18 |
1.4 |
1.2 |
0.5 |
43/2.0 |
2.1 |
2.2 |
36.3 |
39 |
2183 |
3916 |
2840 |
4573 |
|
|
4×95 |
36 |
1.6 |
1.2 |
0.5 |
50/2.0 |
2.3 |
2.4 |
40.6 |
44.1 |
2748 |
5160 |
3545 |
5957 |
|
|
4×120 |
36 |
1.6 |
1.4 |
0.5 |
42/2.5 |
2.4 |
2.5 |
43.9 |
47.2 |
3237 |
6214 |
4334 |
7372 |
|
|
4×150 |
36 |
1.8 |
1.4 |
0.5 |
48/2.5 |
2.5 |
2.6 |
48.3 |
52 |
3853 |
7622 |
5148 |
8917 |
|
|
4×185 |
36 |
2 |
1.6 |
0.5 |
54/2.5 |
2.7 |
2.8 |
54.3 |
57.6 |
4756 |
9323 |
6132 |
10774 |
|
|
4×240 |
60 |
2.2 |
1.6 |
0.5 |
59/2.5 |
2.9 |
3 |
59.2 |
62.9 |
5774 |
11906 |
7374 |
13506 |
|
|
4×300 |
60 |
2.4 |
1.6 |
0.5 |
65/2.5 |
3 |
3.2 |
64.3 |
68.1 |
6922 |
14589 |
8624 |
16291 |
|
5)600/1000V, Multi Cores, Circular Compacted Al or Cu/PVC/PVC Armoured Power Cable
|
Cross Section of Conductor |
No. of Wires |
Thickness of Insulation |
Thickness of Inner Sheath |
Thickness of Steel Tape |
No./Dia. Of Steel Wires |
Thickness of Sheath |
Overall Diameter |
Approx. Net Weight |
|||||
|
STA |
SWA |
||||||||||||
|
STA |
SWA |
STA |
SWA |
STA |
SWA |
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
||||
|
mm2 |
– |
mm |
mm |
mm |
No./mm |
mm |
mm |
mm |
mm |
kg/km |
kg/km |
kg/km |
kg/km |
|
Three Cores |
|||||||||||||
|
3×10 |
7 |
1 |
1 |
0.2 |
35/1.25 |
1.8 |
1.8 |
19.4 |
21.5 |
494 |
679 |
988 |
1172 |
|
3×16 |
7 |
1 |
1 |
0.2 |
32/1.6 |
1.8 |
1.8 |
21.5 |
24.3 |
604 |
895 |
1051 |
1343 |
|
3×25 |
7 |
1.2 |
1 |
0.2 |
38/1.6 |
1.8 |
1.8 |
25 |
27.9 |
791 |
1252 |
1329 |
1790 |
|
3×35 |
7 |
1.2 |
1 |
0.2 |
42/1.6 |
1.8 |
1.9 |
27.2 |
30.2 |
950 |
1595 |
1551 |
2196 |
|
3×50 |
19 |
1.4 |
1.1 |
0.2 |
39/2.0 |
2 |
2.1 |
31.3 |
35.2 |
1213 |
2079 |
2128 |
2994 |
|
3×70 |
19 |
1.4 |
1.2 |
0.5 |
45/2.0 |
2.1 |
2.2 |
35.6 |
40.1 |
1567 |
2894 |
2678 |
4005 |
|
3×95 |
19 |
1.6 |
1.3 |
0.5 |
42/2.5 |
2.3 |
2.4 |
42 |
46.2 |
2449 |
4188 |
3689 |
5428 |
|
3×120 |
37 |
1.6 |
1.3 |
0.5 |
45/2.5 |
2.4 |
2.5 |
45.3 |
49.6 |
2823 |
5014 |
4174 |
6364 |
|
3×150 |
37 |
1.8 |
1.4 |
0.5 |
49/2.5 |
2.5 |
2.7 |
48.9 |
53.2 |
3327 |
6069 |
4795 |
7537 |
|
3×185 |
37 |
2 |
1.5 |
0.5 |
56/2.5 |
2.7 |
2.8 |
54.5 |
58.7 |
4038 |
7371 |
5686 |
9019 |
|
3×240 |
61 |
2.2 |
1.6 |
0.5 |
63/2.5 |
2.9 |
3.1 |
61.4 |
65.2 |
4994 |
9457 |
6862 |
11325 |
|
3×300 |
61 |
2.4 |
1.7 |
0.5 |
70/2.5 |
3.2 |
3.3 |
67.9 |
71.7 |
6022 |
11564 |
8101 |
13643 |
|
3×400 |
61 |
2.6 |
1.9 |
0.5 |
62/3.15 |
3.4 |
3.6 |
75.4 |
80.5 |
7350 |
14543 |
10535 |
17728 |
|
Four Cores |
|||||||||||||
|
4×10 |
7 |
1 |
1 |
0.2 |
39/1.25 |
1.8 |
1.8 |
20.9 |
23 |
552 |
798 |
1073 |
1319 |
|
4×16 |
7 |
1 |
1 |
0.2 |
35/1.6 |
1.8 |
1.8 |
23.3 |
26.1 |
723 |
1110 |
1213 |
1601 |
|
4×25 |
7 |
1.2 |
1 |
0.2 |
42/1.6 |
1.8 |
1.9 |
27.2 |
30.2 |
959 |
1573 |
1559 |
2173 |
|
4×35 |
7 |
1.2 |
1 |
0.2 |
37/2.0 |
1.9 |
2 |
29.7 |
33.6 |
1140 |
2000 |
2006 |
2866 |
|
4×50 |
19 |
1.4 |
1.2 |
0.2 |
44/2.0 |
2.1 |
2.2 |
34.6 |
38.4 |
1524 |
2679 |
2541 |
3696 |
|
4×70 |
19 |
1.4 |
1.2 |
0.5 |
50/2.0 |
2.3 |
2.3 |
40.5 |
43.7 |
2338 |
4107 |
3187 |
4956 |
|
4×95 |
19 |
1.6 |
1.2 |
0.5 |
46/2.5 |
2.4 |
2.6 |
45.9 |
50.2 |
2955 |
5274 |
4325 |
6644 |
|
4×120 |
37 |
1.6 |
1.4 |
0.5 |
51/2.5 |
2.6 |
2.7 |
50 |
54.2 |
3466 |
6387 |
4568 |
7888 |
|
4×150 |
37 |
1.8 |
1.4 |
0.5 |
55/2.5 |
2.7 |
2.8 |
53.8 |
58.1 |
4144 |
7800 |
5772 |
9428 |
|
4×185 |
37 |
2 |
1.6 |
0.5 |
62/2.5 |
2.9 |
3 |
60.2 |
64.5 |
4987 |
9430 |
6822 |
11266 |
|
4×240 |
61 |
2.2 |
1.6 |
0.5 |
70/2.5 |
3.1 |
3.3 |
67.7 |
71.5 |
6161 |
12111 |
8233 |
14184 |
|
4×300 |
61 |
2.4 |
1.6 |
0.5 |
61/3.15 |
3.4 |
3.5 |
74.7 |
78.8 |
7346 |
14735 |
10305 |
17694 |
We are China Copper Conductor PVC Insulated Underground Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Cable Products
Double Insulated Heavy Duty 95mm2 600AMP Welding Cable
Copper or Aluminium Conductor PVC Insulated PVC Sheathed Power Cable
1.5mm 2.5mm Single Core Fire Proof Cable, High Temperature Resistant Cable
Yjv22 Copper Conductor Insulated Steel Tape Armored PVC Sheathed Power Cable
Electric Cable Low Voltage Duplex/Triplex/Quadruplex Overhead ABC Cable
Popular Copper Conductor PVC Insulated Underground Power Cable Products
Popular jpcable99 Products
Cable De Energia Unipolar Tipo N2xsy 12/20kv 1X50mm2 Price
Stranded Galvanized Steel Wire (GSW)
Medium Voltage Underground XLPE Insulated Unarmoured Cable
185mm2 Al Conductor Armored Power Cable
Low Voltage PVC Insulated 4 Core Power Cables
Copper Conductor PVC Insulated Flexible Wire RV/Rvv/Rvs/Rvb Cable
Popular Power Cable Products
600/1000V, XLPE Insulation, PVC Sheathed, Armored Power Cable
Top Ten Manufacturer Copper Aluminium XLPE Power Cable
High Voltage Copper Aluminum Conductor XLPE Insulated Power Cable
Wholesale Electrical Copper Conductor Hook up Wire with PVC Jacket
XLPE Insulated 240mm 3 Core Armoured Power Cable
11kv, 12kv, 6/10kv Single Core 800sqmm Awa Armoured XLPE Cable
Tags: Cable, Copper Conductor PVC Insulated Underground Power Cable, jpcable99, Power Cable