Copper Fire Resistance XLPE Insulation Flame Retardant Sheath Power Cable

China 
                        Copper Fire Resistance XLPE Insulation Flame Retardant Sheath Power Cable
                      manufacture and supplier

Copper Fire Resistance XLPE Insulation Flame Retardant Sheath Power Cable image

Get Latest Price Request a quote

Quick Details

Copper Fire Resistance XLPE Insulation Flame Retardant Sheath Power Cable

4*16mm

Jytop

ISO9001, CE, CCC

Building

Round Wire

XLPE

Flame Retardant Sheath

Copper

Heating

Stranded

Insulated

Black,Red,Yellow,Blue,Brown,Green

0.6/1kv

Ce, ISO 9001

JYTOP

Packed in 100m Coils

3*70mm, 3*120mm+1*70mm

Zhengzhou, China

8544492100

Product Details

Copper Fire Resistance XLPE insulation Flame Retardant sheath Power Cable

Flame retardant cable

The flame retardant cable is mainly featured in low liability of fire or that second combustion is only limited to a certain range, meets the IEC60332 combustion testing requirements, and is applicable to the places with flame retardant requirement.

Product Category
1. Ordinary flame retardant cable: In the event of fire, the cable may produce a large amount of corrosive gases and smoke after combustion, and can be used in general occasions with low flame retardant requirement. Its flammability has A, B,C, D four categories, and its cable models are added with ZRA- (or ZA-), ZRB- (or ZB-), ZRC- (or ZC-), and ZRD- (or ZD-)
before ordinary cable models, respectively.
2. Low-halogen flame-retardant cable: in addition to maintaining the general characteristics and electrical properties of the
flame-retardant cable, it also has the following characteristics:
  a. low halogen acid gas emissions;
  b. low corrosivity;
  c. less smoke generated.
Its cable model is added with DDZ- (or DL-) before ordinary XLPE insulated cables model.
3. Low smoke zero halogen (LSZH) flame retardant cable: featured in:
  a. no halogen acid gas release;
  b. small fuming amount;
  c. less corrosive gas generated;
  d. good flame retardant property.
and has certain mechanical and physical and electrical properties to meet the operating requirements for the cable. It is widely used in nuclear power plants, subway stations, telephone switching and computer control centers, high-rise
buildings, hotels, radio and television stations, important military facilities, oil platforms, etc. Its cable models include WDZYJY,WDZ-YJY23, WDZ-YJY33, WDZ-YJY43, WDZ-YJE, WDZ-YJE23, WDZ-YJE33, WDZ-YJE43 or WL-YJE, WL-YJL23,WL-YJL33, and WL- YJL43, and can be matched with the flame retardant levels A, B, C, D, such as WDZA-.
4. Oxygen-barrier cable (also known as highly-flame retardant cable): a layer of non-melting, non-flammable, halogen-free,smoke-free fire-resistant plastic material is filled or wrapped between the cable insulated core and the cable sheath, i.e.insulating organic is used to isolate the cable from the outside oxygen gas, so that the cable is non-combustible or flameretardent.
Its cable model is added with GZR- before the ordinary cable model.

Main features
1. Ordinary flame retardant cable
For Class A and Class B fire tests, the fire time is 40 minutes, and for Class C and Class D fire tests, the fire time is 20 minutes, and the charring height does not exceed 2.5 m.
2. Low-halogen low-smoke flame retardant cable
Halogen acid gas emission <100 mg/g, smoke density (transmittance) > 30%, from the group burning test, it meets the requirements of Class C flame retardancy.
3. Low smoke zerohalogen (LSZH) flame retardant cable:
Halogen acid gas all-emission 0 mg/g, pH value ≥ 4.3, conductivity ≤ 10 us/mm, toxicity index ≤ 5. From the group burning test, it at least meets the requirements of Class C flame retardancy, smoke density (transmittance) ≥
60%.
4. Oxygen barrier cable (highly-flame retardant cable)
From the group burning test, it meets and exceeds the requirements of Class A flame retardancy, and the smoke density (transmittance) is equal to or close to national standard GB/T17651-2008 and international standard IEC61034 low smoke standard.
It is especially suitable for 6 KV-35 KV medium-voltage cable frame retardancy, has not only flame retardancy up to Class A, but also has certain refractory characteristics (i.e. can still keep 2.4 Uo insulation standard after burning for 20 min).
Notes: Users can select category and class of flame retardant cable according to laying places.

Fire-resistant cable

Fire-resistant cable can still ensure the normal operation of lines within certain time in case of combustion. It is different from the ordinary flame retardant cable in that in the event of a fire, it may continue electricity transmission. The use of this product will allow high-rise buildings, subways, power plants and other major occasions to have better fire safety and fire rescue capability.

Operating characteristics
1. Cable laying temperature: ≥0°C
2. The highest rated temperature values of PVC insulated cable conductor and XLPE insulated cable conductor are 70°C, and 90°C, respectively.
3. The highest rated temperature values of cable conductor in case of short circuit (the longest duration not more than 5s) does not exceed 160°C and 250°C for PVC insulation and XLPE insulation, respectively
4. Under rated voltage of the cable, the fire-resistant cable can maintain 90 min normal operation in is 750°C-800°C flame.
5. Bending radius: same as ordinary cable.

Description of Flame retardant and fire resistant cable:

Product name Bunched flame retardant power wire shielded cable Code letter
Conductor Stranded or tinned copper wire
Insulation Cross-linked polyethylene (XLPE) J
Filler and tape Non-hygroscopic material
Inner sheath Polyvinyl chloride (PVC) V
Screen or Armor Galvanized steel wire braided 9
Outer sheath Polyvinyl chloride (PVC) 2
Flame retardant Bunched flame retardant S
Low smoke and halogen free Low smoke, halogen free and low toxicity A
Rated voltage 0.6/1kV  
Operating temperature -15ºC~+90ºC  
Certificate ABS,BV,CCS,DNV,GL,KR,LR,NK,RINA,RS  
Test voltage 3.5kV/5min  
Smoke density of completed cable ≥60%  
Application shipboard,offshore building, lighting and control system  
Number of cores*section 3*1.5  
Weight 195kg/km  
Outer diameter 11.3-13.3mm  
Model LKMSM-HF(CJV92/SA)  

Parameter of of copper Fire Resistant XLPE insulation Flame Retardant sheath Power cable

N0.of cores×Nominal cross sectional area(mm²) Caculated diameter Caculated weight
Nom(mm) Max(mm) CJV92(kg/km)
2*1 10.5 12.3 152
2*1.5 11.1 13 172
2*2.5 11.9 14 208
2*4 13.3 15.6 265
2*6 14.3 16.8 323
2*10 16.8 19.3 468
2*16 19.2 22.1 644
2*25 22.6 25.4 926
2*35 25.4 28.6 1201
2*50 29 32.6 1579
2*70 32.4 36.5 2095
2*95 37.2 40.9 2831
2*120 42 46.2 3551
2*150 45.8 50.4 4253
2*185 50.4 55.4 5194
3*1 11 12.9 171
3*1.5 11.6 13.6 197
3*2.5 12.7 14.9 250
3*4 14 16.5 316
3*6 15 17.6 393
3*10 18.1 20.8 596
3*16 20.2 22.7 812
3*25 24.3 27.3 1210
3*35 27.3 30.7 1583
3*50 30.7 34.5 2055
3*70 35.3 38.8 2870
3*95 40.2 44.2 3834
3*120 44.5 49 4718
3*150 48.6 53.5 5683
3*185 53.6 59 6979

Selection of current ratings shipboard power cable

Permission continuous operating temp of conductor 90°C

Current ratings of XLPE and EP rubber insulated power cable (Ambient temp 45°C

Nominal cross area of conductor

(mm2)

Single core

two cores

three or four cores

 

five cores

six cores

A

A

A

A

A

1

0.85

0.7

0.58

0.52

1

18

15

12

10

9

1.5

23

20

16

13

12

2.5

30

26

21

17

16

4

41

34

28

23

6

52

44

36

30

10

72

61

50

16

96

82

67

25

127

108

89

35

157

133

110

50

196

167

137

70

242

206

169

95

293

249

205

120

339

288

237

150

389

331

272

185

444

377

311

240

522

444

365

300

601

511

421

We are China Copper Fire Resistance XLPE Insulation Flame Retardant Sheath Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Flame Retardant Cable Products

Fire Resistant Cable Flame Retardant Electric Power Cable

Copper Core PVC Insulated and Sheathed Flame Retardant Control Cable

Low Voltage 3 Core Copper/XLPE/PVC Flame Retardant Cable

Low Voltage Cable Yjv22 Yjv23 Yjv33 Yjv32

Fire Resistant Flame Retardant Power Cable Cu Shielded Electrical Cable

Low Smoke Zero Halogen Flame Retardant Cable

Popular jytopcable Products

ASTM Standard Aluminum Alloy Conductor Steel Reinforced Aacsr Conductor

Triplex Overhead Aerial Bundled Aluminum Cables Urd Wire for AAC/ AAAC/ACSR Cable

N2xsyry 10 Kv XLPE Insulated Round Steel Wire Armoured Single Copper Cable

Overhead Aluminium Bae Conductor AAC AAAC ACSR Cable

0.6/1kv Copper XLPE Insulation Steel Tape Armoured PVC Sheath Power Cable

11kv Cable Steel Wire Armored Cable 3X95mm

Popular Power Cable Products

Cu/XLPE/Cts/PVC/Swa/PVC, Power Cable, 19/33 Kv, 3/C (BS 6622)

Yjv22 Underground Copper/Aluminum Mica Tape Fire-Proof Resistant Steel Armored/Unarmoured XLPE Insulation Sheathed Earth Wire Power Cable

1-35kv Copper Core XLPE Insulated Steel-Tape Armoured and PVC Sheathed Power Cable

240mm XLPE 4 Core Armoured Cable Electric Waterproof Armored Power Cable

Two Cores Copper Conductor XLPE Insulated 35mm Power Cable

IEC60227 300/500V Stranded Copper Wires Single Core Two Cores Three Cores PVC Insulation PVC Sheath RoHS

Popular XLPE Cable Products

U1000 Arvfv   600/1000V Armoured XLPE Aluminum Cables

0.6/1kv XLPE Insulated U-1000 RO2V Power Cable 240mm2 Single Core Cables

Insulated Aerial Bundled Cable Manufacturer Price

ABC Cable. More Than 1000 Buyers in USA

Single Core Copper Wire Screened Cu/Al Substation Power Cable Underground Cable

33kv XLPE Awa 1*500mm Power Cable/HDPE Cu/XLPE/Awa/PE

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION