CSA Listed Nmd90 Nmwu White 14/2 12/2 300V Indoor Building Electrical Wire
CSA Listed Nmd90 Nmwu White 14/2 12/2 300V Indoor Building Electrical Wire image
Get Latest Price Request a quote
Basic Info.
Product Description
CSA certificate 300V NMD 90 NMWU90 Building Wires
– 14/2 to 2/3 Indoor Non-Metallic Cable 150m or 75m per reel
Conductor | Grounding Wire | Jacket Thickness | OD | Weight | Max. DC resistance at 20C (Ω/km) | |||||
Size AWG | NO. | No. of strands | Insulation Thickness | Nylon Thickness | Size ( AWG) | No. of Strands | ||||
mm | mm | mm | mm | kg/km | ||||||
14 | 2 | 1 | 0.76 | 0.13 | 14 | 1 | 0.76 | 4.9 x 9.9 | 108.9 | 8.62 |
12 | 2 | 1 | 0.76 | 0.13 | 14 | 1 | 0.76 | 5.3 x 11.2 | 148.8 | 5.43 |
10 | 2 | 1 | 0.76 | 0.13 | 12 | 1 | 0.76 | 5.9 x 12.8 | 209.9 | 3.41 |
8 | 2 | 7 | 0.89 | 0.16 | 10 | 1 | 1.14 | 8.1 x 16.4 | 324.1 | 2.14 |
6 | 2 | 7 | 1.14 | 0.2 | 8 | 7 | 1.14 | 9.6 x 20.2 | 487.2 | 1.36 |
14 | 3 | 1 | 0.76 | 0.13 | 14 | 1 | 0.76 | 8.8 | 136.5 | 8.62 |
12 | 3 | 1 | 0.76 | 0.13 | 14 | 1 | 0.76 | 9.8 | 177.9 | 5.43 |
10 | 3 | 1 | 0.76 | 0.13 | 12 | 1 | 0.76 | 11 | 249.7 | 3.41 |
8 | 3 | 7 | 0.89 | 0.16 | 10 | 1 | 1.14 | 14.8 | 418.7 | 2.14 |
6 | 3 | 7 | 1.14 | 0.2 | 8 | 7 | 1.14 | 18.1 | 634.4 | 1.36 |
4 | 3 | 7 | 1.14 | 0.2 | 8 | 7 | 1.52 | 21.4 | 917.3 | 0.848 |
3 | 3 | 7 | 1.14 | 0.2 | 6 | 7 | 2.03 | 24.1 | 1188 | 0.673 |
2 | 3 | 7 | 1.14 | 0.2 | 6 | 7 | 2.03 | 25.8 | 1400.9 | 0.534 |
14 | 3 | 1 | 0.76 | 0.13 | 14 | 1 | 0.76 | 8.8 | 169.2 | 8.62 |
12 | 3 | 1 | 0.76 | 0.13 | 14 | 1 | 0.76 | 9.8 | 222.7 | 5.43 |
10 | 3 | 1 | 0.76 | 0.13 | 12 | 1 | 0.76 | 11 | 316.2 | 3.41 |
8 | 3 | 7 | 0.89 | 0.16 | 10 | 1 | 1.14 | 14.8 | 524.4 | 2.14 |
6 | 3 | 7 | 1.14 | 0.2 | 8 | 7 | 1.14 | 18.1 | 800 | 1.36 |
4 | 3 | 7 | 1.14 | 0.2 | 8 | 7 | 1.52 | 21.4 | 1163.3 | 0.848 |
3 | 3 | 7 | 1.14 | 0.2 | 6 | 7 | 2.03 | 24.1 | 1497.8 | 0.673 |
2 | 3 | 7 | 1.14 | 0.2 | 6 | 7 | 2.03 | 25.8 | 1776.2 | 0.534 |
NMD90 XLPE AL Wire
Application:
NMD90 cables may be used for both exposed work in dry locations or concealed work in dry or damp locations.The maximum allowable conductor temperature is 90°C. The minimum recommended installation temperature is -25°C or -40°C for two-conductor cables and -25°C for three-conductor cables (with suitable handling procedures). Material should be properly stored above 0°C for 24 hours prior to installation. The maximum voltage rating for all intended applications is 300 volts. Consult the Canadian Electrical Code1 for further information related to applications.
Structure:
- Conductor: aluminium alloy 8000series ACM with AL groundig wire Grey 6AWG to 2AWG.
- Insulation: crosslinked polyethylene (XLPE)
- Jacket: PVC, Heat and moisture-resistant, flame retardant FT1.
- Number of conductor: 3 and 4 round laid
Standard:
CSA C22.2 No. 48 (non-metallic sheathed cable)
UL File No.:
E487898
Voltage:
300V
Working temperature:
in dry locations only at temperature not to exceed 90°C.
Performance:
FT-1 Flame retardant; Heat and moisture-resistant
Printing:
HT CABLES c(UL) E487898 6AWG 3C AL ACM NMD90 NYLON CABLE FT1 300V (-25ºC) xxx m 2023
Jacket Color: Grey
Technical data:
Conductor | Grounding Wire | Jacket Thickness | Cable Dimensions | Weight | Max. DC resistance at 20C (Ω/km) | |||||
Size AWG | NO. | No. of strands | Insulation Thickness | Nylon Thickness | Size ( AWG) | No. of Strands | ||||
mm | mm | mm | mm | kg/km | ||||||
8 | 3 | 7 | 0.89 | 0.16 | 10 | 1 | 1.14 | 14.8 | 231.8 | 3.52 |
6 | 3 | 7 | 1.14 | 0.2 | 8 | 7 | 1.14 | 18.1 | 337.6 | 2.21 |
4 | 3 | 7 | 1.14 | 0.2 | 8 | 7 | 1.52 | 21.4 | 475.6 | 1.39 |
3 | 3 | 7 | 1.14 | 0.2 | 6 | 7 | 2.03 | 24.1 | 614.7 | 1.1 |
2 | 3 | 7 | 1.14 | 0.2 | 6 | 7 | 2.03 | 25.8 | 701.2 | 0.875 |
8 | 4 | 7 | 0.89 | 0.16 | 10 | 1 | 1.14 | 14.8 | 285.9 | 3.52 |
6 | 4 | 7 | 1.14 | 0.2 | 8 | 7 | 1.14 | 18.1 | 421.4 | 2.21 |
4 | 4 | 7 | 1.14 | 0.2 | 8 | 7 | 1.52 | 21.4 | 591.4 | 1.39 |
3 | 4 | 7 | 1.14 | 0.2 | 6 | 7 | 2.03 | 24.1 | 760.7 | 1.1 |
2 | 4 | 7 | 1.14 | 0.2 | 6 | 7 | 2.03 | 25.8 | 870.6 | 0.875 |
We are China CSA Listed Nmd90 Nmwu White 14/2 12/2 300V Indoor Building Electrical Wire manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular CSA Listed Nmd90 Nmwu White 14/2 12/2 300V Indoor Building Electrical Wire Products
Popular huatongcables Products
PV Plant, System Tinned Copper, Bare Aluminum 8 AWG Solar Cable DC 2000V
4 Core 5 Core 35mm 95mm Copper Conductor XLPE Power Cable
Factory cUL PVC Cables Copper Electric 2/0 AWG Teck90 Teck 90 Armored Armoured Cable
14/2 Nmd90 Cable 14/3 Door to Door Price 12/2
TUV Approved DC 1500kv Tinned Copper Solar Cable 4mm 6mm Manufacturer
Popular Nmd90 Products
PVC cUL Listed 12/2 75m Electrical Wire for Canada Nmd90 14/2
Solid cUL Approved Plastic Spools 14/2 Cable Nmd90 Wire 12/2
CSA Copper Electrical Wire for Residential Projects 14 AWG Nmd90 One Ground Wire
UL cUL Approved Flat Copper 14/2 12/2 Nmd90 Building Cable
Flame Retardant Canada Market Plastic Spools 12/2 Wire 14/2 Nmd90
Huatong Cables Copper or Aluminium Plastic Spools cUL Approved Nmd90 Wire 14/2
Popular Nmwu90 Products
CSA Electrical Wire 300V Nmd90 Nmwu90 Residential Wires 14/2 Indoor Non-Metallic Cable
CSA Canadian Electrical Cable Flat Copper 14/2 12/2 Nmd90 Nmwu90 Wire
CSA Listed Rpv90 RW90 Nmwu Nmd90 Nylon Cable 300V Building Wire 14/2
cUL Listed CSA Certificate Nmd90 Nmwu90 Building Wire Manufacture
Nmd90 14/2 14/3 12/2 CSA Certified C22.2 No. 48 Non-Metallic Sheathed Cable Manufacture
12/2 Nmd90 Nmwu90 Wire 14/2 Copper CSA Listed Canadian Standard Building Wires
Tags: CSA Listed Nmd90 Nmwu White 14/2 12/2 300V Indoor Building Electrical Wire, huatongcables, Nmd90, Nmwu90