Application: Used in remote control system in power plant and substation. It is lighter and more flexible than conventional rubber insulated lead sheathed control cable, also excellent in fire proof and anti-abrasion quality.
Construction- Conductors:Annealed Copper Wire
– Insulation : PVC
– Core Identification : Coloring Method – below 4 cores
(2 cores – Black, White /3 cores – Black, White, Red )
Numbering Method (Above 5 cores)
– Sheath : PVC
Mobile: +86 15037165923
Class and SymbolsPVC Insulated PVC Sheathed Control Cable:CVV
PVC Insulated PVC Sheathed Control Cable (Solid Type):CVS
PVC Insulated PVC Sheathed Control Cable (Shield Type):CVV-S, CVV-SB
Flame-Retardant PVC Insulated PVC Sheathed Control Cable:FR-CVV
Flame-Retardant PVC Insulated PVC Sheathed Control Cable (Shield Type):TFR-CVVS
2 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
2 | 0.5 | 7/0.30 | 0.8 | 1.8 | 10.0 | 36.0 | 0.0162 | 98 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 10.0 | 24.5 | 0.0142 | 110 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 10.5 | 18.1 | 0.0135 | 115 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 11.0 | 12.1 | 0.0115 | 135 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 12.0 | 7.41 | 0.0093 | 180 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 14.5 | 4.61 | 0.0092 | 255 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 15.5 | 3.08 | 0.0078 | 320 | 500/D |
3 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
3 | 0.5 | 7/0.30 | 0.8 | 1.8 | 10.0 | 36.0 | 0.0162 | 110 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 10.5 | 24.5 | 0.0142 | 125 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 11.0 | 18.1 | 0.0135 | 135 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 11.5 | 12.1 | 0.0115 | 160 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 13.0 | 7.41 | 0.0093 | 220 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 15.0 | 4.61 | 0.0092 | 315 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 16.5 | 3.08 | 0.0078 | 405 | 500/D |
4 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
4 | 0.5 | 7/0.30 | 0.8 | 1.8 | 11.0 | 36.0 | 0.0162 | 130 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 11.5 | 24.5 | 0.0142 | 150 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 11.5 | 18.1 | 0.0135 | 160 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 12.5 | 12.1 | 0.0115 | 195 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 14.0 | 7.41 | 0.0093 | 265 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 16.5 | 4.61 | 0.0092 | 390 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 17.0 | 3.08 | 0.0078 | 510 | 500/D |
Mobile: +86 15037165923
5 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
5 | 0.5 | 7/0.30 | 0.8 | 1.8 | 11.5 | 36.0 | 0.0162 | 150 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 12.5 | 24.5 | 0.0142 | 175 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 12.5 | 18.1 | 0.0135 | 190 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 13.5 | 12.1 | 0.0115 | 230 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 15.0 | 7.41 | 0.0093 | 320 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 18.0 | 4.61 | 0.0092 | 470 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 19.5 | 3.08 | 0.0078 | 620 | 500/D |
6 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
6 | 0.5 | 7/0.30 | 0.8 | 1.8 | 12.5 | 36.0 | 0.0162 | 165 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 13.0 | 24.5 | 0.0142 | 190 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 13.5 | 18.1 | 0.0135 | 205 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 14.5 | 12.1 | 0.0115 | 255 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 16.0 | 7.41 | 0.0093 | 355 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 19.5 | 4.61 | 0.0092 | 525 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 21.0 | 3.08 | 0.0078 | 690 | 500/D |
7 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
7 | 0.5 | 7/0.30 | 0.8 | 1.8 | 12.5 | 36.0 | 0.0162 | 170 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 13.0 | 24.5 | 0.0142 | 200 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 13.5 | 18.1 | 0.0135 | 215 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 14.5 | 12.1 | 0.0115 | 270 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 16.0 | 7.41 | 0.0093 | 380 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 19.5 | 4.61 | 0.0092 | 570 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 21.0 | 3.08 | 0.0078 | 795 | 500/D |
8 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
8 | 0.5 | 7/0.30 | 0.8 | 1.8 | 13.5 | 36.0 | 0.0162 | 195 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 14.0 | 24.5 | 0.0142 | 230 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 14.5 | 18.1 | 0.0135 | 250 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 15.5 | 12.1 | 0.0115 | 310 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 17.5 | 7.41 | 0.0093 | 440 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 21.0 | 4.61 | 0.0092 | 660 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 23.0 | 3.08 | 0.0078 | 875 | 500/D |
Mobile: +86 15037165923
9 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
9 | 0.5 | 7/0.30 | 0.8 | 1.8 | 14.0 | 36.0 | 0.0162 | 220 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 15.0 | 24.5 | 0.0142 | 265 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 15.5 | 18.1 | 0.0135 | 285 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 16.5 | 12.1 | 0.0115 | 355 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 18.5 | 7.41 | 0.0093 | 505 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 22.5 | 4.61 | 0.0092 | 760 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 24.5 | 3.08 | 0.0078 | 1015 | 500/D |
10 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
10 | 0.5 | 7/0.30 | 0.8 | 1.8 | 15.5 | 36.0 | 0.0162 | 240 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 16.0 | 24.5 | 0.0142 | 285 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 16.5 | 18.1 | 0.0135 | 310 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 18.0 | 12.1 | 0.0115 | 385 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 20.0 | 7.41 | 0.0093 | 550 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 24.5 | 4.61 | 0.0092 | 825 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 27.0 | 3.08 | 0.0078 | 1100 | 500/D |
11 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
11 | 0.5 | 7/0.30 | 0.8 | 1.8 | 15.5 | 36.0 | 0.0162 | 255 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 16.5 | 24.5 | 0.0142 | 315 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 17.0 | 18.1 | 0.0135 | 340 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 18.5 | 12.1 | 0.0115 | 425 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 21.0 | 7.41 | 0.0093 | 605 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 25.0 | 4.61 | 0.0092 | 915 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 27.5 | 3.08 | 0.0078 | 1220 | 500/D |
12 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
12 | 0.5 | 7/0.30 | 0.8 | 1.8 | 15.5 | 36.0 | 0.0162 | 265 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 16.5 | 24.5 | 0.0142 | 320 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 17.0 | 18.1 | 0.0135 | 345 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 18.5 | 12.1 | 0.0115 | 440 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 21.0 | 7.41 | 0.0093 | 630 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 25.0 | 4.61 | 0.0092 | 950 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 27.5 | 3.08 | 0.0078 | 1270 | 500/D |
13 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
13 | 0.5 | 7/0.30 | 0.8 | 1.8 | 16.5 | 36.0 | 0.0162 | 295 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 17.5 | 24.5 | 0.0142 | 355 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 18.0 | 18.1 | 0.0135 | 380 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 19.5 | 12.1 | 0.0115 | 485 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 22.0 | 7.41 | 0.0093 | 695 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 26.5 | 4.61 | 0.0092 | 1050 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 29.0 | 3.08 | 0.0078 | 1405 | 500/D |
14 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
14 | 0.5 | 7/0.30 | 0.8 | 1.8 | 16.5 | 36.0 | 0.0162 | 300 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 17.5 | 24.5 | 0.0142 | 360 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 18.0 | 18.1 | 0.0135 | 390 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 19.5 | 12.1 | 0.0115 | 495 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 22.0 | 7.41 | 0.0093 | 715 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 26.5 | 4.61 | 0.0092 | 1085 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 29.0 | 3.08 | 0.0078 | 1455 | 500/D |
15 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
15 | 0.5 | 7/0.30 | 0.8 | 1.8 | 17.0 | 36.0 | 0.0162 | 330 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 18.5 | 24.5 | 0.0142 | 395 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 19.0 | 18.1 | 0.0135 | 425 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 20.5 | 12.1 | 0.0115 | 545 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 23.0 | 7.41 | 0.0093 | 785 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 28.0 | 4.61 | 0.0092 | 1195 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 31.0 | 3.08 | 0.0078 | 1600 | 500/D |
16 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
16 | 0.5 | 7/0.30 | 0.8 | 1.8 | 17.0 | 36.0 | 0.0162 | 330 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 18.5 | 24.5 | 0.0142 | 400 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 19.0 | 18.1 | 0.0135 | 435 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 20.5 | 12.1 | 0.0115 | 555 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 23.0 | 7.41 | 0.0093 | 805 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 28.0 | 4.61 | 0.0092 | 1230 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 31.0 | 3.08 | 0.0078 | 1650 | 500/D |
17 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
17 | 0.5 | 7/0.30 | 0.8 | 1.8 | 18.0 | 36.0 | 0.0162 | 355 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 19.0 | 24.5 | 0.0142 | 430 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 19.5 | 18.1 | 0.0135 | 465 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 21.5 | 12.1 | 0.0115 | 595 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 24.0 | 7.41 | 0.0093 | 865 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 29.5 | 4.61 | 0.0092 | 1315 | 500/D | |
6 | 7/1.04 | 1.0 | 1.9 | 32.5 | 3.08 | 0.0078 | 1785 | 500/D |
18 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
18 | 0.5 | 7/0.30 | 0.8 | 1.8 | 18.0 | 36.0 | 0.0162 | 360 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 19.0 | 24.5 | 0.0142 | 435 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 19.5 | 18.1 | 0.0135 | 475 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 21.5 | 12.1 | 0.0115 | 605 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 24.0 | 7.41 | 0.0093 | 885 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 29.5 | 4.61 | 0.0092 | 1350 | 500/D | |
6 | 7/1.04 | 1.0 | 1.9 | 32.5 | 3.08 | 0.0078 | 1835 | 500/D |
19 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
19 | 0.5 | 7/0.30 | 0.8 | 1.8 | 18.0 | 36.0 | 0.0162 | 365 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 19.0 | 24.5 | 0.0142 | 445 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 19.5 | 18.1 | 0.0135 | 480 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 21.5 | 12.1 | 0.0115 | 620 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 24.0 | 7.41 | 0.0093 | 905 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 29.5 | 4.61 | 0.0092 | 1385 | 500/D | |
6 | 7/1.04 | 1.0 | 1.9 | 32.5 | 3.08 | 0.0078 | 1885 | 500/D |
20 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
20 | 0.5 | 7/0.30 | 0.8 | 1.8 | 19.0 | 36.0 | 0.0162 | 390 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 20.0 | 24.5 | 0.0142 | 475 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 20.5 | 18.1 | 0.0135 | 515 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 22.5 | 12.1 | 0.0115 | 665 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 25.5 | 7.41 | 0.0093 | 975 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 31.0 | 4.61 | 0.0092 | 1490 | 500/D | |
6 | 7/1.04 | 1.0 | 2.0 | 34.5 | 3.08 | 0.0078 | 2040 | 500/D |
21 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
21 | 0.5 | 7/0.30 | 0.8 | 1.8 | 19.0 | 36.0 | 0.0162 | 400 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 20.0 | 24.5 | 0.0142 | 490 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 20.5 | 18.1 | 0.0135 | 530 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 22.5 | 12.1 | 0.0115 | 685 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 25.5 | 7.41 | 0.0093 | 1005 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 31.0 | 4.61 | 0.0092 | 1540 | 500/D | |
6 | 7/1.04 | 1.0 | 2.0 | 34.5 | 3.08 | 0.0078 | 2040 | 500/D |
22 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
22 | 0.5 | 7/0.30 | 0.8 | 1.8 | 20.0 | 36.0 | 0.0162 | 430 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 21.0 | 24.5 | 0.0142 | 520 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 21.5 | 18.1 | 0.0135 | 565 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 23.5 | 12.1 | 0.0115 | 730 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 265 | 7.41 | 0.0093 | 1070 | 500/D | |
4 | 7/0.85 | 1.0 | 1.9 | 32.5 | 4.61 | 0.0092 | 1655 | 500/D | |
6 | 7/1.04 | 1.0 | 2.0 | 36.5 | 3.08 | 0.0078 | 2245 | 500/D |
23 Core CVV Control Cable
Mobile: +86 15037165923
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
23 | 0.5 | 7/0.30 | 0.8 | 1.8 | 19.5 | 36.0 | 0.0162 | 440 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 21.0 | 24.5 | 0.0142 | 540 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 21.5 | 18.1 | 0.0135 | 585 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 23.5 | 12.1 | 0.0115 | 755 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 26.5 | 7.41 | 0.0093 | 1105 | 500/D | |
4 | 7/0.85 | 1.0 | 1.9 | 32.5 | 4.61 | 0.0092 | 1710 | 500/D | |
6 | 7/1.04 | 1.0 | 2.0 | 36.5 | 3.08 | 0.0078 | 2330 | 500/D |
24 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
24 | 0.5 | 7/0.30 | 0.8 | 1.8 | 21.0 | 36.0 | 0.0162 | 460 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 22.0 | 24.5 | 0.0142 | 560 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 23.0 | 18.1 | 0.0135 | 605 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 24.5 | 12.1 | 0.0115 | 785 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 28.0 | 7.41 | 0.0093 | 1150 | 500/D | |
4 | 7/0.85 | 1.0 | 2.0 | 34.5 | 4.61 | 0.0092 | 1795 | 500/D | |
6 | 7/1.04 | 1.0 | 2.0 | 36.5 | 3.08 | 0.0078 | 2330 | 500/D |
25 Core CVV Control Cable
Mobile: +86 15037165923
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
25 | 0.5 | 7/0.30 | 0.8 | 1.8 | 21.0 | 36.0 | 0.0162 | 490 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 22.5 | 24.5 | 0.0142 | 595 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 23.0 | 18.1 | 0.0135 | 645 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 25.5 | 12.1 | 0.0115 | 835 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 28.5 | 7.41 | 0.0093 | 1225 | 500/D | |
4 | 7/0.85 | 1.0 | 2.0 | 35.5 | 4.61 | 0.0092 | 1915 | 500/D | |
6 | 7/1.04 | 1.0 | 2.1 | 39.5 | 3.08 | 0.0078 | 2595 | 500/D |
26 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
27 | 0.5 | 7/0.30 | 0.8 | 1.8 | 21.0 | 36.0 | 0.0162 | 500 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 22.5 | 24.5 | 0.0142 | 610 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 23.0 | 18.1 | 0.0135 | 665 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 25.5 | 12.1 | 0.0115 | 860 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 28.5 | 7.41 | 0.0093 | 1270 | 500/D | |
4 | 7/0.85 | 1.0 | 2.0 | 35.5 | 4.61 | 0.0092 | 1985 | 500/D | |
6 | 7/1.04 | 1.0 | 2.1 | 39.5 | 3.08 | 0.0078 | 2700 | 500/D |
27 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
27 | 0.5 | 7/0.30 | 0.8 | 1.8 | 21.0 | 36.0 | 0.0162 | 500 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 22.5 | 24.5 | 0.0142 | 610 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 23.0 | 18.1 | 0.0135 | 665 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 25.5 | 12.1 | 0.0115 | 860 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 28.5 | 7.41 | 0.0093 | 1270 | 500/D | |
4 | 7/0.85 | 1.0 | 2.0 | 35.5 | 4.61 | 0.0092 | 1985 | 500/D | |
6 | 7/1.04 | 1.0 | 2.1 | 39.5 | 3.08 | 0.0078 | 2700 | 500/D |
28 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
28 | 0.5 | 7/0.30 | 0.8 | 1.8 | 22.0 | 36.0 | 0.0162 | 535 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 23.5 | 24.5 | 0.0142 | 650 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 24.0 | 18.1 | 0.0135 | 710 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 26.0 | 12.1 | 0.0115 | 915 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 30.0 | 7.41 | 0.0093 | 1350 | 500/D | |
4 | 7/0.85 | 1.0 | 2.0 | 37.0 | 4.61 | 0.0092 | 2110 | 500/D | |
6 | 7/1.04 | 1.0 | 2.2 | 41.5 | 3.08 | 0.0078 | 2885 | 500/D |
29 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
29 | 0.5 | 7/0.30 | 0.8 | 1.8 | 22.0 | 36.0 | 0.0162 | 540 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 23.5 | 24.5 | 0.0142 | 660 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 24.0 | 18.1 | 0.0135 | 715 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 26.0 | 12.1 | 0.0115 | 930 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 30.0 | 7.41 | 0.0093 | 1370 | 500/D | |
4 | 7/0.85 | 1.0 | 2.0 | 37.0 | 4.61 | 0.0092 | 2145 | 500/D | |
6 | 7/1.04 | 1.0 | 2.2 | 41.5 | 3.08 | 0.0078 | 2940 | 500 |
Mobile: +86 15037165923
We are China Cvv Copper Control Cable Cvv-S Cvv-Swa manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Control Cable Products
The Multi-Core Coloured Soft Control Cable Vct-F
Multi Core Plastic Insulated Copper Control Cable with Sheathed.
Yy Multi Core Control Cable PVC Insulated 10 Core Power Flexible Cable
Kyjvrp14*0.75 Control Cable Wire/ Kyjvrp2*0.75 Factory Control Cable
Control Cables Multi-Cores, ISO CCC Ce Certificates
Popular Cvv Copper Control Cable Products
Popular Cvv-Swa Cable Products
Popular zzhongdacable Products
RoHS Standard PVC Insulated and Sheathed H07vvh2-F 2g 0.75mm2 1.0mm2 Flat Copper Flexible Wire Cable
Cuivre Nu 29mm2 Bare Copper Earth Cable
50mm 70mm 95mm Copper Conductor Underground Electrical Power Cable
LV 120 Sq mm 4 Core Power Cable Manufacturers 4 Core 95mm Power Cable XLPE Insulation
AAAC All Aluminum Alloy Conductor
Low Voltage 0.6/1kv Aluminum XLPE Insulated Na2xy Power Cable
Tags: Control Cable, Cvv Copper Control Cable, Cvv-Swa Cable, zzhongdacable