Dimension Test on M14X300 Bolt and Nut:

China 
                        Dimension Test on M14X300 Bolt and Nut:
                      manufacture and supplier

Dimension Test on M14X300 Bolt and Nut: image

Get Latest Price Request a quote

Quick Details

Dimension Test on M14X300 Bolt and Nut:

Oei Power

Grey

ISO9001, IEC IEEE

160KN

Trough Type

High Voltage Power Transmission

A Type Insulator

Suspension Insulator

Composite Polymer

High-voltage, Low-voltage, High-temperature

OEIpower

Cartons Pallets Wooden Case

IEC IEEE

China Nanyang

854690000

Product Details

The Composite Insulators comply with the latest editions of and amendments to, the standards/specification listed below:
 
CSA                                CANADIAN STANDARDS ASSOCIATION
 
G164-4                       –      Hot dip galvanizing of Irregular Shaped Articles
 
CAN/CSA                 –      Quality Assurance Program Categories 2299.3
 
ANSI                          –     AMERICAN NATIONAL STANDARDS INSTITUTE
 
C29.1                          –     American Standard Test Method For Electrical Power Insulators
 
C29.7                          –     American Standard For Wet-processed Porcelain Insulators (High Voltage Line Post Type) Electrical Power Insulators
 
987-1985                    –      IEEE Guide For Application of Composite Insulators
 
D750                           –     Recommended Practice for Operating Light and Weather Exposure Apparatus (Carbon Arc Type) For Artificial Weather Testing Of Rubber Compounds.
 
D1499                         –     Recommended Practice For Exposure of Plastics.
 
D2240                         –     Rubber Properties, Durometer Hardness
 
D2565                         –     Recommended Practice For Operating Xenon-Arc Light And Water Exposure Apparatus Plastics.
The weathershed of the Post Insulators shall be manufactured from either Hydrated Alumina Ethylene Propylene Copolymer (EPM) as the primary constituent or Silicone Elastomers. The weathershead shall be injection moulded and brought to final cure state in one continuous process to prevent internal undercure or surface overcure. Additionally, the weathershead shall provide hydrophobic surface, even after exposure to tropical marine environment, ultra violent rays and moisture.
Core
 
The rod or the core is manufactured from Fibreglass, having 70-75 by weight of auxiliary aligned glass fibre bonded by an organic resin. The rod is either be cast or pultruded.
The end fittings are have the following properties:
 
i.         are compressed onto the Fibreglass rod member
ii.        are  not move relative to the central Fibreglass rod at applied loads equal to two times the rated Routine Test Load or maximum designed cantilever loads
iii.       are attracted to the rod after completion of all external heat processes used to cure or bond component parts.
 
The insulator are  provided load limiting bases that will deform under longitudinal loading of more than 100% of the rated design cantilever load. 
Performance Characteristics
 
The Polymeric Insulators are meet the under listed performance characteristics.
 

 
           ITEM
 
              11kV
 
              33KV
 
Dry Flashover Withstand
 
              90kV     
 
              180kV
 
Wet flashover withstand
 
              70kV
 
              165kV
 
Positive Impulse Critical flashover
 
             145kV
 
               300kV
 
Maximum Radio Interference Voltage
 
Below 1micro volt
 
  Below 1 micro volt        
 
Design Tension Strength
 
              100kN
 
               100kN
 
Residual Strength after Power Arc
 
                80kN
 
                80kN
 
Mechanical Proof Test Load
 
               45kN
 
                 45kN
 
Maximum Sustained Load
 
               34kN
 
                 34kN
 
Design Torque Rating
 
              83 Nm
 
                 83 Nm

 
 
The insulator are suitable for accepting both aluminium and copper conductors having cross-sectional areas ranging from 35mm2 to 265mm2. The insulators are designed for mounting on the angle and channel crossarms specified in Specification E14
 
All exposed ferrous part shall be treated against corrosion. Treatment by hot dip galvanizing is preferable.
 
 

View More  

Not exactly what you want?

Post Sourcing Request

Hot Searches

Insulator
Voltage Insulator
High Voltage Insulator
Rubber Insulator
Ceramic Insulator
Silicon Insulator
View More 

We are China Dimension Test on M14X300 Bolt and Nut: manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Composite Insulator Products

Parallel Clamp

Steel U Channel 4200 X 100X 75 X 6 mm

110kv Composite Insulator/Long Rod Suspension Polymer Insulator

11kv 12kn Silicon Composite Polymer Line Post Insulator

Composite Suspension Insulator for Transmission Line

Porcelain Insulators for All Kinds

Popular jgtrade1 Products

Chain Shackle

V Type D Fuse 21kv

11kv Expulsion Fuse C/W Holder.

Clamp, 3 Bolt Guy Cp 3ia-336.4

High Quality High Voltage Fuse Xrnt Type Vvp

Pole Anti-Collision Warning Sticker

Popular Polymer Insulator Products

Polymer Insulator Composite Post Insulator

Insulator for Silicon Rubber Pin Type

Silicon Suspension Insulator Polymer Insulator

Insulator, Pintype 55 - 5 1" C905-1305

110kv Suspension Tension Type Composite/ Polymer Insulators

Sleeve; Pre-Insul Service Ysu 2W 2W

Popular Silicone Rubber Insulator Products

with-Button Wire. New with-Trip Fuse Wire, High-Voltage Condenser's Pecial Fuse Wire

Box Type Fixed Totally Enclosed Switchgear

Washer, Flat Sq

Isoladores De Porcelana P-33y Polymer Insulator

110kv Polymer Suspension Insulator/High Quality Long Rod Composite Insulator

Holding Clamp

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION