Direct Manufacturer Supply PVC Armoured Power Cable
Direct Manufacturer Supply PVC Armoured Power Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Application:
With the characteristics of stable capability,advanced technology,broad material resources,low price, good flexible and easy to lay and maintain, the PVC Insulated and Sheathed Power Cable are suitable to be laid for distribution line with A.C.50HZ and rated voltage up to 6kV.
Property:
1.The long-time permissible working temperature of cable conductive core is not more than 70 °C.
2.During short circuit (max. permanent time is not more than 5 seconds), the max temperature of cable conductor is not more than 165°C.
3.The difference level of laying cable is not restricted.When laying the cable,ambient temperature is not lower than 0°C.
4.They have good chemical stability,and properties of acid resistance,alkali resistance,salt resistance,oil resistance,solvent resistance and flame resistance.rty
5.Light weight,good bending property and easy installation and maintenance.
Specification:
Standard:
IEC,BS,VDE,AS/NZS,ICEA,JIS and so on,designing and manufacturing special power cable according to the other standards required by the customer
1)600/1000V, Single Core, Circular Compacted Al or Cu/PVC/PVC Unarmoured or Armoured Power Cable
Cross Section of Conductor |
No. of Wires |
Thickness of Insulation |
Unarmoured |
Armoured |
||||||||
Thickness of Sheath |
Overall Dia. |
jpcable99.en. Weight |
Thickness of Bedding |
Thickness of Al Tape |
Thickness of Sheath |
Overall Dia. |
jpcable99.en. Weight |
|||||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
|||||||||
mm2 |
– |
mm |
mm |
mm |
kg/km |
kg/km |
mm |
mm |
mm |
mm |
kg/km |
kg/km |
1.5 |
1 |
0.8 |
1.4 |
5.8 |
– |
51 |
– |
– |
– |
– |
– |
– |
2.5 |
1 |
0.8 |
1.4 |
6.2 |
– |
64 |
– |
– |
– |
– |
– |
– |
4 |
1 |
1 |
1.4 |
7.1 |
– |
88 |
– |
– |
– |
– |
– |
– |
6 |
7 |
1 |
1.4 |
7.8 |
78 |
114 |
– |
– |
– |
– |
– |
– |
10 |
7 |
1 |
1.4 |
8.6 |
96 |
159 |
1 |
0.5 |
1.8 |
13.4 |
234 |
295 |
16 |
7 |
1 |
1.4 |
9.6 |
123 |
222 |
1 |
0.5 |
1.8 |
14.4 |
274 |
370 |
25 |
7 |
1.2 |
1.4 |
11.2 |
172 |
328 |
1 |
0.5 |
1.8 |
16 |
344 |
496 |
35 |
7 |
1.2 |
1.4 |
12.2 |
209 |
428 |
1 |
0.5 |
1.8 |
17 |
393 |
606 |
50 |
19 |
1.4 |
1.4 |
13.9 |
271 |
565 |
1 |
0.5 |
1.8 |
18.7 |
478 |
764 |
70 |
19 |
1.4 |
1.5 |
15.9 |
356 |
818 |
1 |
0.5 |
1.8 |
20.5 |
582 |
1020 |
95 |
19 |
1.6 |
1.5 |
18 |
471 |
1041 |
1 |
0.5 |
1.8 |
22.6 |
717 |
1291 |
120 |
37 |
1.6 |
1.6 |
19.6 |
563 |
1307 |
1 |
0.5 |
1.8 |
24 |
822 |
1545 |
150 |
37 |
1.8 |
1.6 |
21.3 |
684 |
1592 |
1 |
0.5 |
1.8 |
25.4 |
952 |
1857 |
185 |
37 |
2 |
1.7 |
23.9 |
840 |
1985 |
1 |
0.5 |
1.8 |
27.9 |
1136 |
2236 |
240 |
61 |
2.2 |
1.8 |
27 |
1071 |
2533 |
1 |
0.5 |
1.9 |
31 |
1404 |
2877 |
300 |
61 |
2.4 |
1.9 |
29.6 |
1317 |
3162 |
1.2 |
0.5 |
2.1 |
34.3 |
1722 |
3551 |
400 |
61 |
2.6 |
2 |
33.2 |
1666 |
4120 |
1.2 |
0.5 |
2.2 |
37.6 |
2114 |
4488 |
500 |
61 |
2.8 |
2.2 |
37.5 |
2089 |
5163 |
1.2 |
0.5 |
2.3 |
42.1 |
2592 |
5683 |
630 |
61 |
2.8 |
2.3 |
41.2 |
2581 |
6447 |
1.4 |
0.5 |
2.4 |
46.3 |
3184 |
7060 |
2)600/1000V, Multi Cores, Sectoral Compacted Al or Cu/PVC/PVC Unarmoured Power Cable
Number of Cores |
Cross-Section of Conductor |
No. Of Wires |
Thickness of Insulation |
Thickness of Sheath |
Overall Diameter |
Approx. Net Weight |
|
Al Conductor |
Cu Conductor |
||||||
– |
mm2 |
– |
mm |
mm |
mm |
kg/km |
kg/km |
Three Cores |
3×35 |
16 |
1.2 |
1.8 |
21.9 |
601 |
1280 |
3×50 |
18 |
1.4 |
1.8 |
26.5 |
829 |
1732 |
|
3×70 |
18 |
1.4 |
1.9 |
29.2 |
1067 |
2367 |
|
3×95 |
36 |
1.6 |
2 |
32.9 |
1409 |
2317 |
|
3×120 |
36 |
1.6 |
2.1 |
36.2 |
1705 |
3983 |
|
3×150 |
36 |
1.8 |
2.2 |
38.8 |
2045 |
4872 |
|
3×185 |
36 |
2 |
2.4 |
44.8 |
2596 |
6077 |
|
3×240 |
60 |
2.2 |
2.6 |
51.5 |
3353 |
7953 |
|
3×300 |
60 |
2.4 |
2.7 |
54.9 |
6069 |
9820 |
|
Four Cores with Reduced Neutral |
3×35+16 |
16-7 |
1.2-1 |
1.8 |
25.5 |
764 |
1107 |
3×50+25 |
18-16 |
1.4-1.2 |
1.9 |
28.7 |
982 |
1410 |
|
3×70+35 |
18-16 |
1.4-1.2 |
2.0 |
32 |
1278 |
1733 |
|
3×95+50 |
36-18 |
1.6-1.4 |
2.2 |
37.8 |
1711 |
2656 |
|
3×120+70 |
36-18 |
1.6-1.4 |
2.3 |
40.5 |
2065 |
3137 |
|
3×150+70 |
36-18 |
1.8-1.4 |
2.4 |
44.8 |
2480 |
3660 |
|
3×185+95 |
36-36 |
2-1.6 |
2.6 |
49.7 |
3086 |
4345 |
|
3×240+120 |
60-36 |
2.2-1.6 |
2.8 |
56 |
3894 |
5441 |
|
3×300+150 |
60-36 |
1.4-1.8 |
2.9 |
60.3 |
4834 |
6494 |
|
Four Cores |
4×25 |
16 |
1.2 |
1.8 |
22.5 |
644 |
1286 |
4×35 |
16 |
1.2 |
1.8 |
24.6 |
799 |
1696 |
|
4×50 |
18 |
1.4 |
1.8 |
28.6 |
1071 |
2275 |
|
4×70 |
18 |
1.4 |
2 |
31.6 |
1387 |
3120 |
|
4×95 |
36 |
1.6 |
2.1 |
35.9 |
1850 |
4262 |
|
4×120 |
36 |
1.6 |
2.2 |
38.8 |
2209 |
5247 |
|
4×150 |
36 |
1.8 |
2.3 |
43.1 |
2714 |
6483 |
|
4×185 |
36 |
2 |
2.5 |
48.7 |
3403 |
8045 |
|
4×240 |
60 |
2.2 |
2.7 |
53.6 |
4290 |
10422 |
|
4×300 |
60 |
2.4 |
2.9 |
58.8 |
5302 |
12969 |
3)600/1000V, Multi Cores, Circular Compacted Al or Cu/PVC/PVC Unarmoured Power Cable
Number of Cores |
Cross-Section of Conductor |
No. Of Wires |
Thickness of Insulation |
Thickness of Sheath |
Overall Diameter |
Approx. Net Weight |
||
Al Conductor |
Cu Conductor |
|||||||
– |
mm2 |
– |
mm |
mm |
mm |
kg/km |
kg/km |
|
Three Cores |
3×10 |
7 |
1 |
1.8 |
16.6 |
281 |
465 |
|
3×16 |
7 |
1 |
1.8 |
18.7 |
387 |
679 |
||
3×25 |
7 |
1.2 |
1.8 |
22.2 |
536 |
996 |
||
3×35 |
7 |
1.2 |
1.8 |
24.4 |
665 |
1311 |
||
3×50 |
19 |
1.4 |
1.9 |
28.1 |
863 |
1729 |
||
3×70 |
19 |
1.4 |
2 |
32.3 |
1153 |
2480 |
||
3×95 |
19 |
1.6 |
2.1 |
37.1 |
1563 |
3301 |
||
3×120 |
37 |
1.6 |
2.3 |
40.4 |
1850 |
4040 |
||
3×150 |
37 |
1.8 |
2.4 |
43.9 |
2258 |
5000 |
||
3×185 |
37 |
2 |
2.5 |
49.2 |
2819 |
6151 |
||
3×240 |
61 |
2.2 |
2.8 |
55.9 |
3577 |
8040 |
||
3×300 |
61 |
2.4 |
3 |
62.1 |
4413 |
9955 |
||
3×400 |
61 |
2.6 |
3.2 |
69.3 |
5512 |
12705 |
||
Four Cores |
4×10 |
7 |
1 |
1.8 |
18.1 |
343 |
589 |
|
4×16 |
7 |
1 |
1.8 |
20.5 |
487 |
874 |
||
4×25 |
7 |
1.2 |
1.8 |
24.3 |
677 |
1291 |
||
4×35 |
7 |
1.2 |
1.8 |
26.8 |
821 |
1681 |
||
4×50 |
19 |
1.4 |
2 |
31.2 |
1118 |
2273 |
||
4×70 |
19 |
1.4 |
2.1 |
35.8 |
1494 |
3264 |
||
4×95 |
19 |
1.6 |
2.3 |
41.2 |
1993 |
4312 |
||
4×120 |
37 |
1.6 |
2.4 |
44.8 |
2370 |
5291 |
||
4×150 |
37 |
1.8 |
2.5 |
48.7 |
2959 |
6615 |
||
4×185 |
37 |
2 |
2.7 |
54.7 |
3601 |
8044 |
||
4×240 |
61 |
2.2 |
3 |
62.1 |
4596 |
10547 |
||
4×300 |
61 |
2.4 |
3.2 |
69.1 |
5614 |
13004 |
4)600/1000V, Multi Cores, Sectoral Compacted Al or Cu/PVC/PVC Armoured Power Cable
Cross Section of Conductor |
No. of Wires |
Thickness of Insulation |
Thickness of Inner Sheath |
Thickness of Steel Tape |
No./Dia. Of Steel Wires |
Thickness of Sheath |
Overall Diameter |
Approx. Net Weight |
||||||
STA |
SWA |
|||||||||||||
STA |
SWA |
STA |
SWA |
STA |
SWA |
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
|||||
mm2 |
– |
mm |
mm |
mm |
No./mm |
mm |
mm |
mm |
mm |
kg/km |
kg/km |
kg/km |
kg/km |
|
Three Cores |
||||||||||||||
3×35 |
16 |
1.2 |
1 |
0.2 |
38/1.6 |
1.8 |
1.9 |
24.7 |
28.2 |
912 |
1591 |
1447 |
2126 |
|
3×50 |
18 |
1.4 |
1 |
0.2 |
46/1.6 |
1.9 |
2 |
29.3 |
32.8 |
1202 |
2105 |
1842 |
2745 |
|
3×70 |
18 |
1.4 |
1.2 |
0.2 |
41/2.0 |
2.0 |
2.2 |
32.5 |
37.1 |
1520 |
2820 |
2475 |
3775 |
|
3×95 |
36 |
1.6 |
1.2 |
0.5 |
46/2.0 |
2.1 |
2.3 |
36.5 |
40.8 |
2241 |
4049 |
2989 |
4797 |
|
3×120 |
36 |
1.6 |
1.2 |
0.5 |
50/2.0 |
2.2 |
2.4 |
39.8 |
44.1 |
2617 |
4895 |
3435 |
5713 |
|
3×150 |
36 |
1.8 |
1.2 |
0.5 |
43/2.5 |
2.3 |
2.5 |
42.4 |
47.8 |
3019 |
5846 |
4258 |
7085 |
|
3×185 |
36 |
2 |
1.4 |
0.5 |
50/2.5 |
2.5 |
2.7 |
48.8 |
54.2 |
3783 |
7264 |
5219 |
8700 |
|
3×240 |
60 |
2.2 |
1.6 |
0.5 |
58/2.5 |
2.8 |
2.9 |
56 |
61.3 |
4790 |
9390 |
6444 |
11044 |
|
3×300 |
60 |
2.4 |
1.6 |
0.5 |
61/2.5 |
2.9 |
3.1 |
59.3 |
64.7 |
5594 |
11345 |
7458 |
13209 |
|
Four Cores with Reduced Neutral |
||||||||||||||
3×35+16 |
16-7 |
1.2-1 |
1 |
0.2 |
43/1.6 |
1.9 |
2 |
28.5 |
31.3 |
1107 |
1528 |
1705 |
2469 |
|
3×50+25 |
18-16 |
1.4-1.2 |
1.2 |
0.2 |
40/2.0 |
2.0 |
2.1 |
32.2 |
36.1 |
1410 |
2044 |
2326 |
3388 |
|
3×70+35 |
18-16 |
1.4-1.2 |
1.2 |
0.2 |
44/2.0 |
2.0 |
2.2 |
35.2 |
39.3 |
1733 |
2801 |
2762 |
4285 |
|
3×95+50 |
36-18 |
1.6-1.4 |
1.2 |
0.5 |
41/2.5 |
2.3 |
2.5 |
42.5 |
46.3 |
2656 |
3820 |
3816 |
5925 |
|
3×120+70 |
36-18 |
1.6-1.4 |
1.4 |
0.5 |
45/2.5 |
2.4 |
2.6 |
45.6 |
49.4 |
3137 |
4777 |
4391 |
7103 |
|
3×150+70 |
36-18 |
1.8-1.4 |
1.4 |
0.5 |
49/2.5 |
2.6 |
2.7 |
49.9 |
53.6 |
3660 |
5709 |
5043 |
8272 |
|
3×185+95 |
36-36 |
2-1.6 |
1.4 |
0.5 |
55/2.5 |
2.6 |
2.9 |
54.5 |
58.5 |
3445 |
7171 |
5902 |
9987 |
|
3×240+120 |
60-36 |
2.2-1.6 |
1.6 |
0.5 |
62/2.5 |
2.9 |
3.1 |
61.6 |
65.3 |
5441 |
9272 |
7174 |
12552 |
|
3×300+150 |
60-36 |
1.4-1.8 |
1.6 |
0.5 |
67/2.5 |
3.8 |
3.2 |
65.9 |
69.6 |
6494 |
11546 |
8355 |
15067 |
|
Four Cores |
||||||||||||||
4×25 |
16 |
1.2 |
1 |
0.2 |
38/1.6 |
1.8 |
1.9 |
25.3 |
28 |
934 |
1576 |
1450 |
2092 |
|
4×35 |
16 |
1.2 |
1 |
0.2 |
41/1.6 |
1.8 |
1.9 |
27.4 |
30.2 |
1120 |
2017 |
1681 |
2578 |
|
4×50 |
18 |
1.4 |
1 |
0.2 |
39/2.0 |
2 |
2.1 |
31.6 |
35.6 |
1454 |
2658 |
2336 |
3540 |
|
4×70 |
18 |
1.4 |
1.2 |
0.5 |
43/2.0 |
2.1 |
2.2 |
36.3 |
39 |
2183 |
3916 |
2840 |
4573 |
|
4×95 |
36 |
1.6 |
1.2 |
0.5 |
50/2.0 |
2.3 |
2.4 |
40.6 |
44.1 |
2748 |
5160 |
3545 |
5957 |
|
4×120 |
36 |
1.6 |
1.4 |
0.5 |
42/2.5 |
2.4 |
2.5 |
43.9 |
47.2 |
3237 |
6214 |
4334 |
7372 |
|
4×150 |
36 |
1.8 |
1.4 |
0.5 |
48/2.5 |
2.5 |
2.6 |
48.3 |
52 |
3853 |
7622 |
5148 |
8917 |
|
4×185 |
36 |
2 |
1.6 |
0.5 |
54/2.5 |
2.7 |
2.8 |
54.3 |
57.6 |
4756 |
9323 |
6132 |
10774 |
|
4×240 |
60 |
2.2 |
1.6 |
0.5 |
59/2.5 |
2.9 |
3 |
59.2 |
62.9 |
5774 |
11906 |
7374 |
13506 |
|
4×300 |
60 |
2.4 |
1.6 |
0.5 |
65/2.5 |
3 |
3.2 |
64.3 |
68.1 |
6922 |
14589 |
8624 |
16291 |
5)600/1000V, Multi Cores, Circular Compacted Al or Cu/PVC/PVC Armoured Power Cable
Cross Section of Conductor |
No. of Wires |
Thickness of Insulation |
Thickness of Inner Sheath |
Thickness of Steel Tape |
No./Dia. Of Steel Wires |
Thickness of Sheath |
Overall Diameter |
Approx. Net Weight |
|||||
STA |
SWA |
||||||||||||
STA |
SWA |
STA |
SWA |
STA |
SWA |
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
||||
mm2 |
– |
mm |
mm |
mm |
No./mm |
mm |
mm |
mm |
mm |
kg/km |
kg/km |
kg/km |
kg/km |
Three Cores |
|||||||||||||
3×10 |
7 |
1 |
1 |
0.2 |
35/1.25 |
1.8 |
1.8 |
19.4 |
21.5 |
494 |
679 |
988 |
1172 |
3×16 |
7 |
1 |
1 |
0.2 |
32/1.6 |
1.8 |
1.8 |
21.5 |
24.3 |
604 |
895 |
1051 |
1343 |
3×25 |
7 |
1.2 |
1 |
0.2 |
38/1.6 |
1.8 |
1.8 |
25 |
27.9 |
791 |
1252 |
1329 |
1790 |
3×35 |
7 |
1.2 |
1 |
0.2 |
42/1.6 |
1.8 |
1.9 |
27.2 |
30.2 |
950 |
1595 |
1551 |
2196 |
3×50 |
19 |
1.4 |
1.1 |
0.2 |
39/2.0 |
2 |
2.1 |
31.3 |
35.2 |
1213 |
2079 |
2128 |
2994 |
3×70 |
19 |
1.4 |
1.2 |
0.5 |
45/2.0 |
2.1 |
2.2 |
35.6 |
40.1 |
1567 |
2894 |
2678 |
4005 |
3×95 |
19 |
1.6 |
1.3 |
0.5 |
42/2.5 |
2.3 |
2.4 |
42 |
46.2 |
2449 |
4188 |
3689 |
5428 |
3×120 |
37 |
1.6 |
1.3 |
0.5 |
45/2.5 |
2.4 |
2.5 |
45.3 |
49.6 |
2823 |
5014 |
4174 |
6364 |
3×150 |
37 |
1.8 |
1.4 |
0.5 |
49/2.5 |
2.5 |
2.7 |
48.9 |
53.2 |
3327 |
6069 |
4795 |
7537 |
3×185 |
37 |
2 |
1.5 |
0.5 |
56/2.5 |
2.7 |
2.8 |
54.5 |
58.7 |
4038 |
7371 |
5686 |
9019 |
3×240 |
61 |
2.2 |
1.6 |
0.5 |
63/2.5 |
2.9 |
3.1 |
61.4 |
65.2 |
4994 |
9457 |
6862 |
11325 |
3×300 |
61 |
2.4 |
1.7 |
0.5 |
70/2.5 |
3.2 |
3.3 |
67.9 |
71.7 |
6022 |
11564 |
8101 |
13643 |
3×400 |
61 |
2.6 |
1.9 |
0.5 |
62/3.15 |
3.4 |
3.6 |
75.4 |
80.5 |
7350 |
14543 |
10535 |
17728 |
Four Cores |
|||||||||||||
4×10 |
7 |
1 |
1 |
0.2 |
39/1.25 |
1.8 |
1.8 |
20.9 |
23 |
552 |
798 |
1073 |
1319 |
4×16 |
7 |
1 |
1 |
0.2 |
35/1.6 |
1.8 |
1.8 |
23.3 |
26.1 |
723 |
1110 |
1213 |
1601 |
4×25 |
7 |
1.2 |
1 |
0.2 |
42/1.6 |
1.8 |
1.9 |
27.2 |
30.2 |
959 |
1573 |
1559 |
2173 |
4×35 |
7 |
1.2 |
1 |
0.2 |
37/2.0 |
1.9 |
2 |
29.7 |
33.6 |
1140 |
2000 |
2006 |
2866 |
4×50 |
19 |
1.4 |
1.2 |
0.2 |
44/2.0 |
2.1 |
2.2 |
34.6 |
38.4 |
1524 |
2679 |
2541 |
3696 |
4×70 |
19 |
1.4 |
1.2 |
0.5 |
50/2.0 |
2.3 |
2.3 |
40.5 |
43.7 |
2338 |
4107 |
3187 |
4956 |
4×95 |
19 |
1.6 |
1.2 |
0.5 |
46/2.5 |
2.4 |
2.6 |
45.9 |
50.2 |
2955 |
5274 |
4325 |
6644 |
4×120 |
37 |
1.6 |
1.4 |
0.5 |
51/2.5 |
2.6 |
2.7 |
50 |
54.2 |
3466 |
6387 |
4568 |
7888 |
4×150 |
37 |
1.8 |
1.4 |
0.5 |
55/2.5 |
2.7 |
2.8 |
53.8 |
58.1 |
4144 |
7800 |
5772 |
9428 |
4×185 |
37 |
2 |
1.6 |
0.5 |
62/2.5 |
2.9 |
3 |
60.2 |
64.5 |
4987 |
9430 |
6822 |
11266 |
4×240 |
61 |
2.2 |
1.6 |
0.5 |
70/2.5 |
3.1 |
3.3 |
67.7 |
71.5 |
6161 |
12111 |
8233 |
14184 |
4×300 |
61 |
2.4 |
1.6 |
0.5 |
61/3.15 |
3.4 |
3.5 |
74.7 |
78.8 |
7346 |
14735 |
10305 |
17694 |
We are China Direct Manufacturer Supply PVC Armoured Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Armoured Cable Products
Underground Copper Conductor XLPE Insulated Power Cable
2018 Factory Price High Quality Power Cable
XLPE Insulated Armoured Cable/VV32/Yjv32
Aluminum Conductor PVC Insulated 0.6/1kv IEC Standard Power Cable
600/1000V Al/XLPE/Sta/PVC Hge Power Cable Underground Cables
Popular Cable Products
Aluminum Conductor PVC Insulated and Sheathed Flat Cables Electrical Wire
Waterproof Outdoor Fiber Optic Power Composite Cable
Good Price 14AWG-2AWG 12AWG-2AWG 14/2 Electric Cable Canadian Wire cUL Certificate Nmd90
Copper/ Aluminum Conductor XLPE Insulation Service Concentric Cable
XLPE Insulated Aluminum Conductor Aerial Bundle Cable
BS Standard Racoon 75mm2 Electric Aluminum Wire Cable Steel Reinforced ACSR Conductor
Popular jpcable99 Products
ACSR Aluminum Conductor Steel Reinforced (ASTM B232 Standard)
Excellent Performance 0.6/1kv 70mm2/54.6mm2 Aerial Bundled Cable
Copper Conductor Steel Wire Armoured Power Cable
Screened Rubber Sheathed Movable and Flexible Mine Power Cable
High Quality 3 Core XLPE Insulated Armoured Power Cable
Popular Power Cable Products
600/1000V 3c 70mm2 XLPE Insulated Armoured Power Cable PVC Insulated Wire Cable
11kv 1 Core 55sqmm Triple Extruded Longitudanally Water Covered AAAC Cable
PV-1f 4AWG Sunlight Resistant Electric Solar Panels PV Solar Power Cable
4mm2 12AWG Flexible Tinned Copper Xlpo Sheath Electrical PV Solar Cable
33kv Overhead ABC Cable Manufacturer Quadruplex Service Drop Wire Cable
IEC BS Standard XLPE Insulated 3 Core Power Cable
Tags: Armoured Cable, Cable, jpcable99, Power Cable