Duplex Triplex Quadruplex Aerial Bunched/Bundled Overhead XLPE Insulated Aluminum ABC Cable

China 
                Duplex Triplex Quadruplex Aerial Bunched/Bundled Overhead XLPE Insulated Aluminum ABC Cable
              manufacture and supplier

Duplex Triplex Quadruplex Aerial Bunched/Bundled Overhead XLPE Insulated Aluminum ABC Cable image

Get Latest Price Request a quote

Basic Info.

Model NO.
ABC cable

Conductor Material
Aluminum

Sheath Material
XLPE PE

Insulation Material
PE

Material Shape
Round Wire

Range of Application
Overhead Transmision

Certification
ISO9001, CE, CCC

Brand
Sanwu

Delivery Date
15 Working Days

Conductor Shape
Circular Core or Compact Core

Cross Section Area
1.5-800 mm2

Standard
IEC, BS, ASTM,DIN

Certificate
ISO, TUV, CCC, IEC

Transport Package
Wooden Drum

Specification
10-800mm2

Trademark
SanWu Cable

Origin
China

HS Code
8544492100

Production Capacity
500000/Per Month

Packaging & Delivery

Package Size
1100.00cm * 1100.00cm * 600.00cm

Package Gross Weight
1500.000kg

Product Description

LUOYANG SANWU CABLE GROUP with registered capital of 100 million RMB, is a high-tech development company for scientific research, industry producing and trading, offering a diverse selection of quality wires and cables to industrial customers in more than 50 countries worldwide. The leading products are ACSR, Overhead ABC cables, Conductor, AAAC, AAC, power cable etc.

SANWU CABLE owns variously advanced equipment and large quantities of high skilled professionals. With complete management system, advanced production process, strict testing procedure and reliable product quality, we have successively got IS09001, IS014001,OHSAS18001,TUV Certificate, CCC(China Compulsory Certification), the national industrial production license and so on.
In terms of quality, it
 is highly controlled by our company to ensure that all the products we sell meet your requirements and give you reassurance with excellent after-sale service.In terms of service, we are focusing on your need, we concern what you concern and request what you request to provide a more satisfied service.

    Product Description

    ASTM BS CSA Standard Overhead Aluminium Conductor Aerial Bundle Cable

  ABC Cable Application
  This production is suitable for electric cable below 10KV AC, which will be mainly used for city power grid transmission line. It is simple structure, 

  safety and stable and is of good mechanism physical and electricity function. And also it has good function of proof track, creepage

  discharge, and air. Compared with naked wire, it has small gap so that can save wire route and decrease voltage drop. What is the 

  most important is that it will decrease the accident in power supplying and make people safe.

  Specific Property for ABC Cable

 1) the min. temperature of laying cable is not lower than 20°C.

 2) the Max. temperature of HDPE insulated cable is 150°C, and that of the XLPE insulated cable is   250°C when short circuit (5 seconds ).

 3) the Max. long-time working temperature of conductor of the HDPE insulated cable is 75°C,and that of the XLPE insulated cable is 90°C.

 4) every fault time of single-phase earth shall be less than one minute. And that also shall be less than 8 hours per time and be less than 125hours   every year.

 5) the permissible curving radius of single-core cable should be not less than 20(D±d) ±5%mm, and that of the multi-core cable should be not less   than 15(D±d) ±5%mm.

 ABC cable sketch structure as follows:

 Executive Standard:IEC   

Phas e Neutral Phas e Neutral

Approx. Overall Diam eter

Max. D.C.
Res is tance of Conductor at 20ºC
AAC+UV-XLPE AAAC Com pact Conductor UV-XLPE Ins ulation Conductor
No.X Norm al Cr os s
Section of Cores
No.X Norm al Cr os s
Section of Cores
No.of Al.Wire Overall Dia. Norm al Thick nes s Min. No./Dia. of Al Alloy Wire Phas e Neutral
No. X m m 2 No. X m m 2 m m m m Min. No./m m m m ohm /k m ohm /k m
1 X 16 1 X 16 7/1.70 4.8 1.2 0.98 7/1.70 12.3 1.91 2.217
1 X 25 1 X 25 7/2.24 6 1.2 0.98 7/2.10 14.7 1.2 1.393
1 X 35 1 X 35 7/2.58 7 1.4 1.16 7/2.50 17.3 0.868 1.007
1 X 50 1 X 50 7/3.00 8.3 1.4 1.16 7/3.00 20.1 0.641 0.744
1 X 70 1 X 70 19/2.15 9.8 1.4 1.16 7/3.50 23.1 0.443 0.514
1 X 95 1 X 95 19/2.58 11.6 1.6 1.34 19/2.50 27.3 0.32 0.371
1 X 120 1 X 120 18/3.00 13 1.6 1.34 19/2.80 30.2 0.253 0.294
1 X 150 1 X 150 30/2.58 14.6 1.8 1.52 37/2.25 33.95 0.206 0.239
1 X 185 1 X 185 36/2.58 16.2 2 1.7 37/2.50 37.7 0.164 0.19
1 X 240 1 X 240 36/3.00 18.4 2.2 1.88 61/2.25 43.05 0.125 0.145
2 X 16 1 X 16 7/1.70 4.8 1.2 0.98 7/1.70 14.04 1.91 2.217
2 X 25 1 X 25 7/2.24 6 1.2 0.98 7/2.10 16.63 1.2 1.393
2 X 35 1 X 35 7/2.58 7 1.4 1.16 7/2.50 19.51 0.868 1.007
2 X 50 1 X 50 7/3.00 8.3 1.4 1.16 7/3.00 22.46 0.641 0.744
2 X 70 1 X 70 19/2.15 9.8 1.4 1.16 7/3.50 25.7 0.443 0.514
2 X 95 1 X 95 19/2.58 11.6 1.6 1.34 19/2.50 30.31 0.32 0.371
2 X 120 1 X 120 18/3.00 13 1.6 1.34 19/2.80 33.41 0.253 0.294
2 X 150 1 X 150 30/2.58 14.6 1.8 1.52 37/2.25 37.55 0.206 0.239
2 X 185 1 X 185 36/2.58 16.2 2 1.7 37/2.50 41.69 0.164 0.19
2 X 240 1 X 240 36/3.00 18.4 2.2 1.88 61/2.25 47.41 0.125 0.145
3 X 16 1 X 16 7/1.70 4.8 1.2 0.98 7/1.70 16.15 1.91 2.217
3 X 25 1 X 25 7/2.24 6 1.2 0.98 7/2.10 19.06 1.2 1.393
3 X 35 1 X 35 7/2.58 7 1.4 1.16 7/2.50 22.32 0.868 1.007
3 X 50 1 X 50 7/3.00 8.3 1.4 1.16 7/3.00 25.59 0.641 0.744
3 X 70 1 X 70 19/2.15 9.8 1.4 1.16 7/3.50 29.22 0.443 0.514
3 X 95 1 X 95 19/2.58 11.6 1.6 1.34 19/2.50 34.42 0.32 0.371
3 X 120 1 X 120 18/3.00 13 1.6 1.34 19/2.80 37.87 0.253 0.294
3 X 150 1 X 150 30/2.58 14.6 1.8 1.52 37/2.25 42.56 0.206 0.239
3 X 185 1 X 185 36/2.58 16.2 2 1.7 37/2.50 47.25 0.164 0.19
3 X 240 1 X 240 36/3.00 18.4 2.2 1.88 61/2.25 53.63 0.125 0.145

 

Phas e Neutral Phas e Neutral

Approx. Overall Diam eter

Max. D.C.
Res is tance of Conductor at 20ºC
AAC+UV-XLPE AAAC Com pact Conductor UV-XLPE Ins ulation Conductor
No.X Norm al Cr os s
Section of Cores
No.X Norm al Cr os s
Section of Cores
No.of Al.Wire Overall Dia. Norm al Thick nes s Min. No./Dia. of Al Alloy Wire Phas e Neutral
No. X m m 2 No. X m m 2 m m m m Min. No./m m m m ohm /k m ohm /k m
1 X 16 1 X 16 7/1.70 4.8 1.2 0.98 7/1.70 12.3 1.91 2.217
1 X 25 1 X 25 7/2.24 6 1.2 0.98 7/2.10 14.7 1.2 1.393
1 X 35 1 X 35 7/2.58 7 1.4 1.16 7/2.50 17.3 0.868 1.007
1 X 50 1 X 50 7/3.00 8.3 1.4 1.16 7/3.00 20.1 0.641 0.744
1 X 70 1 X 70 19/2.15 9.8 1.4 1.16 7/3.50 23.1 0.443 0.514
1 X 95 1 X 95 19/2.58 11.6 1.6 1.34 19/2.50 27.3 0.32 0.371
1 X 120 1 X 120 18/3.00 13 1.6 1.34 19/2.80 30.2 0.253 0.294
1 X 150 1 X 150 30/2.58 14.6 1.8 1.52 37/2.25 33.95 0.206 0.239
1 X 185 1 X 185 36/2.58 16.2 2 1.7 37/2.50 37.7 0.164 0.19
1 X 240 1 X 240 36/3.00 18.4 2.2 1.88 61/2.25 43.05 0.125 0.145
2 X 16 1 X 16 7/1.70 4.8 1.2 0.98 7/1.70 14.04 1.91 2.217
2 X 25 1 X 25 7/2.24 6 1.2 0.98 7/2.10 16.63 1.2 1.393
2 X 35 1 X 35 7/2.58 7 1.4 1.16 7/2.50 19.51 0.868 1.007
2 X 50 1 X 50 7/3.00 8.3 1.4 1.16 7/3.00 22.46 0.641 0.744
2 X 70 1 X 70 19/2.15 9.8 1.4 1.16 7/3.50 25.7 0.443 0.514
2 X 95 1 X 95 19/2.58 11.6 1.6 1.34 19/2.50 30.31 0.32 0.371
2 X 120 1 X 120 18/3.00 13 1.6 1.34 19/2.80 33.41 0.253 0.294
2 X 150 1 X 150 30/2.58 14.6 1.8 1.52 37/2.25 37.55 0.206 0.239
2 X 185 1 X 185 36/2.58 16.2 2 1.7 37/2.50 41.69 0.164 0.19
2 X 240 1 X 240 36/3.00 18.4 2.2 1.88 61/2.25 47.41 0.125 0.145
3 X 16 1 X 16 7/1.70 4.8 1.2 0.98 7/1.70 16.15 1.91 2.217
3 X 25 1 X 25 7/2.24 6 1.2 0.98 7/2.10 19.06 1.2 1.393
3 X 35 1 X 35 7/2.58 7 1.4 1.16 7/2.50 22.32 0.868 1.007
3 X 50 1 X 50 7/3.00 8.3 1.4 1.16 7/3.00 25.59 0.641 0.744
3 X 70 1 X 70 19/2.15 9.8 1.4 1.16 7/3.50 29.22 0.443 0.514
3 X 95 1 X 95 19/2.58 11.6 1.6 1.34 19/2.50 34.42 0.32 0.371
3 X 120 1 X 120 18/3.00 13 1.6 1.34 19/2.80 37.87 0.253 0.294
3 X 150 1 X 150 30/2.58 14.6 1.8 1.52 37/2.25 42.56 0.206 0.239
3 X 185 1 X 185 36/2.58 16.2 2 1.7 37/2.50 47.25 0.164 0.19
3 X 240 1 X 240 36/3.00 18.4 2.2 1.88 61/2.25 53.63 0.125 0.145

 

Phase Neutral Service Connection Phase Neutral Service Connection Approx. Overall
Diameter of Bundled Cable
AAC+UV-XLPE AAAC+UV-XLPE AAC+UV-XLPE Conductor UV-XLPE Conductor UV-XLPE Compact Conductor UV-XLPE
No.X Normal Cross
Section of Cores
No.X Normal Cross
Section of Cores
No.X Normal Cross
Section of Cores
No. of Al. Wire Overall Dia. Normal No./Dia. of Al. Wire Normal No. of Al. Wire Overall Dia. Normal
Thickness Thickness Thickness
No. X mm2 No. X mm2 No. X mm2 mm mm mm mm No./mm mm mm mm
3 X 16 1 X 50 1 X 16 7/1.70 4.8 1.2 7/3.0 1.4 7/1.70 4.8 1.2 26.2
3 X 25 1 X 50 1 X 16 7/2.24 6 1.2 7/3.0 1.4 7/1.70 4.8 1.2 28.6
3 X 35 1 X 50 1 X 16 7/2.58 7 1.4 7/3.0 1.4 7/1.70 4.8 1.2 31.4
3 X 50 1 X 50 1 X 16 7/3.00 8.3 1.4 7/3.0 1.4 7/1.70 4.8 1.2 34
3 X 70 1 X 50 1 X 16 19/2.15 9.8 1.4 7/3.0 1.4 7/1.70 4.8 1.2 37
3 X 95 1 X 50 1 X 16 19/2.58 11.6 1.6 7/3.0 1.4 7/1.70 4.8 1.2 41.4
3 X 120 1 X 50 1 X 16 18/3.00 13 1.6 7/3.0 1.4 7/1.70 4.8 1.2 44.2
3 X 16 1 X 50 2 X 16 7/1.70 4.8 1.2 7/3.0 1.4 7/1.70 4.8 1.2 26.2
3 X 25 1 X 50 2 X 16 7/2.24 6 1.2 7/3.0 1.4 7/1.70 4.8 1.2 28.6
3 X 35 1 X 50 2 X 16 7/2.58 7 1.4 7/3.0 1.4 7/1.70 4.8 1.2 31.4
3 X 50 1 X 50 2 X 16 7/3.00 8.3 1.4 7/3.0 1.4 7/1.70 4.8 1.2 34
3 X 70 1 X 50 2 X 16 19/2.15 9.8 1.4 7/3.0 1.4 7/1.70 4.8 1.2 37
3 X 95 1 X 50 2 X 16 19/2.58 11.6 1.6 7/3.0 1.4 7/1.70 4.8 1.2 41.4
3 X 120 1 X 50 2 X 16 18/3.00 13 1.6 7/3.0 1.4 7/1.70 4.8 1.2 44.2

 Executive Standard:ASTM

Code Word AWG or k cm il Bare neutral Mes s enger Phas e conductor Weight (k g/k m )
AAAC
s trading and w ires dia(m m )
Rated Strength
(lbs )
AAC
s trading and w ires dia(m m )
ins ulation thick nes s (m m )
Bay 3*6AWG+ 1*30.58 7/ 1.68 1110 1/4.11 1.14 207
French Coach 3*6AWG+ 1*30.58 7/ 1.68 1110 7/ 1.56 1.14 2 13
German Coach 3*4AWG+ 1*48.69 7/2. 12 1760 1/5.1 9 1.14 309
Arabian 3*4AWG+ 1*48.69 7/2. 12 1760 7/ 1.96 1.14 316
Belgian 3*2AWG+ 1*77.47 7/2.67 2800 7/2.47 1.14 476
Shet land 3*1/0AWG+ 1*123.3 7/3.37 4460 19/ 1.89 1.52 768
Thoroughbred 3*2/0AWG+ 1*155.4 7/3.78 5390 19/2.13 1.52 945
Trotter 3*2/0AWG+ 1*195.7 7/4.25 6790 19/2.39 1.52 1166
Walking 3*4/0AWG+ 1*246.9 7/4.77 8560 19/2.68 1.52 1442

Executive Standard:NFC

Des cr iption

Nom inal
cros s -s ection aera
Wire num ber in Conductor Max res is tance at 20 Average diam eter of
conductor
Rated Strength Average ins ulation thick nes s
m m 2 No. Ohm /k m Min(m m ) Max(m m ) KN m m

PHASE, NEUTRAL,
and PUBLIC HIGHTING

16 7 1.91 4.6 5.1 1.9 1.2
25 7 1.2 5.8 6.3   1.4
35 7 0.868 6.8 7.3   1.6
50 7 0.641 7.9 8.4   1.6
70 12 0.443 9.7 10.2   1.8
95 19 0.32 11 12   1.8
120 19 0.253 12 13.1   1.8
150 19 0.206 13.9 15   1.7
PORTER 54.6 7 0.63 9.2 9.6   1.6
70 7 0.5 10 10.2   1.5
95 19 0.343 12.2 12.9 27.5 1.6

Material Standard:
1) The hard aluminum conductor used for AAC and ACSR conforms to the standard GB/T 17048-1997 (equivalent to IEC 60889:1987)
2) The zinc coated steel wire used for ACSR confirms to IEC 60888:1987
3) Production can be arranged according to customers’ requirement such as material standard etc.
4) We can also produce products according to the Standard of BS215, ASTM B232, and DIN48204.Technical characteristics

Certifications

ISO9001:2008, OHSAS, CCC, TUV Certifications.

Package&Shipping:

For Package: Support to pack as rolls, or with wooden drum or wooden steel drums. 

Shipment terms: 

By FOB, CFR or CIF by sea.

By DHL, UPS, Fedex express etc are also available.

Our Services

Luoyang Asian Sun Industrial Group Co., Ltd, a professional wires and cables manufacturer for 6 years in China. Asian Sun attends International Exhibitions every year, we mainly produce power cables, control cables, aerial overhead cables(ABC, AAC ACSR and AAAC cables) and solar pv cables etc. Standards Supported: ASTM, BS, CSA, IEC, DIN and GB etc.

1. Factory: 200,081 square meters, available for OEM;

2. Lead time: 5-7 working days after payment received;

3. Authentication: TUV, OHSAS, CCC, CQC, ISO9001:2008;

4. Payment terms: T/T, L/C, O/A;

5. Guarantee: 20 years;

6. QC inspection: Strict inspection before delivery;

After-sales Service:

1. All our cables will be tested well in production and before delivery.

2. Please contact us if any problem, we will respond within 24 hours.

Customers Visiting:

 
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

We are China Duplex Triplex Quadruplex Aerial Bunched/Bundled Overhead XLPE Insulated Aluminum ABC Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Conductor Products

IEC60502 0.6/1kv 1 X 240mm2 3 X 185mm2 Aluminum/ Copper Conductor XLPE Insulation or PVC Insulation Steel Copper Wire Shielding Wire Armoured PVC Sheath

Acss Condcutor Aluminum Conductor. Steel Supported for Manufacturer Price

Aluminum Conductor Steel Reinforced/ACSR 1/0AWG

ACSR Conductor (Aluminum Conduct Steel Reinforced) Dog 100mm2

Certification Medium Voltage Aluminium Conductor ABC Cable

Type AAAC 6201 Darien 559.5MCM 283.7mm2 All Aluminum Alloy Conductor

Popular Duplex Triplex Quadruplex Aerial Bunched/Bundled Overhead XLPE Insulated Aluminum ABC Cable Products

  • No related articles
  • Popular dycable Products

    Power Cable AAC All Aluminum Conductors in Wooden Drum

    Aluminium Conductor Steel Reinforced ACSR Conductor in China Cable Industry

    XLPE Overhead Aerial Bundle Cable of 16mm 50mm 54.6mm 100mm

    All Aluminium Alloy Conductor Stranded ACSR Bare Aerial Conductor

    2/0 AWG Quadplex Aerial Bundled ABC Cable

    UV Resistance Solar Wire 6mm PV Cable 10AWG

    Popular Wire Cable Products

    ASTM Standard Aster Aluminum AAC Overhead Bare Conductor

    Yellow/Green 4 mm2 6mm2 10mm2 Flexible Building Earth Wire

    8AWG 10AWG 12AWG Tw Thw PVC Insulated Electric Wire

    BS Standard Maybug 450sqmm All Aluminum Stranded Electric Wire Overhead Bare AAC Conductor

    BS Standard AAAC All Aluminum Alloy Strand electric Wire 60mcm AAAC Conductor

    BS Standard 600V Electrical Cable 3 X 95mm2 XLPE Insulation Copper/Aluminum Conductor Copper Stape Screen Steel Wire Armoured PVC Sheath Cable Water Proof

    Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION