Electric 0.6/1kv Power Aluminum Conductor XLPE Insulated Overhead Aerial Bundle Cable, Duplex/Triple/Quadruplex Service Drop/Urd/ABC Wire

China 
                        Electric 0.6/1kv Power Aluminum Conductor XLPE Insulated Overhead Aerial Bundle Cable, Duplex/Triple/Quadruplex Service Drop/Urd/ABC Wire
                      manufacture and supplier

Electric 0.6/1kv Power Aluminum Conductor XLPE Insulated Overhead Aerial Bundle Cable, Duplex/Triple/Quadruplex Service Drop/Urd/ABC Wire image

Get Latest Price Request a quote

Quick Details

Electric 0.6/1kv Power Aluminum Conductor XLPE Insulated Overhead Aerial Bundle Cable, Duplex/Triple/Quadruplex Service Drop/Urd/ABC Wire

Douplex/Triple/Quadruplex Service Drop ABC Cable

Renda

ABC Cable, Service Drop Wire

ISO, CCC, CE, RoHS, UL, VDE, TUV, Psb, SABS, Kema

Aluminum or Copper

Round Wire

No Sheath

XLPE, PE

DC & AC

Low and Medium Voltage Cable

Construction, Overhead, Industrial, Power Station

600V, 0.6/1kv

IEC502, 227, NF C 33-209

ABC Cable, Aerial Bundle Cable

16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2

as Your Requirements

Service Drop Cable ABC Cable

Duplex / Triplex/ Quadruplex

4-477 AWG or Kcmil

Free Sample Available

Losh, Anti UV

RNEDA

Standard Export Wooden Reel or Coil

IEC, BS, DIN, ASTM, IECA NFC

Tangshan. Hebei. China

8544492100

Product Details

0.6/1kv Power Aluminum Conductor XLPE Insulated Cable
Overhead Aerial Bundle Cable
Duplex/Triple/Quadruplex Service Drop/URD/ABC Cable

=========================================================
Professional OEM manufacturer

Top ten cable manufactuer in China

Leading ESP cable manufacture, largest Rubber cable manufacturer in China.

With UL,TUV,KEMA,CE,BV,PSB,SABA certifications

With TUV TYPE TESTING REPORT
With ISO9001,ISO18001,OHSAS18001 syetem certifications
=========================================================
We produce the ABC Electric Cable used for the overhead line(duplex, triplex, quadruplex) in IEC standard, ASTM ANSI/ICEA S-76-474   NF C 33-209 standard.

LV ABC cable(Aerial Bundle cable) with AAAC conductor
Service Drop Cable(ABC CABLE) is mainly used for electric power transmission, Duplex, Triplex, Quadruplex.
Service Drop Cable(ABC CABLE) is mainly used for electric power transmission, rebuilding of urban and forest regions. They can improve safety and reliance of electrified wire netting.


TYPE ONE Service Drop wire ABC CABLE
ABC CABLE -aerial bundle cable: is mainly used for electric power transmission, rebuilding of urban and forest regions. They can improve safety and reliance of electrified wire netting.

 Applications: To supply 120-volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.

Construction

Phase Conductor construction: The phase conductor is aluminum alloy 1350-H19 hard-drawn, compressed concentric-lay-stranded.

Neutral Conductor Construction
Cable assemblies are available with the following neutral conductors:

Aluminum conductors, coated-steel reinforced (ACSR), concentric-lay-stranded

Aluminum alloy 1350-H19 hard-drawn, concentric-lay-stranded

Aluminum alloy 6201-T81, concentric-lay-stranded
Insulation Material
The standard insulation on the phase conductor is black low-density crosslinked polyethylene (XLPE)

Alternatively, black linear low-density polyethylene (LLDPE) insulation with a 75°C temperature rating is available upon request. 
Standards
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum Conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).

6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474

 Duplex Service Drop-Aluminum Conductor
 

Code Phase Conductor Bare Neutral Messenger Weight Per Rating(Amps)
Name 1000 ft(lbs)
  Size Strand Insulation Size *Strand Breaking XLP POLY XLP POLY
  AWG thickness AWG strength
    (MLS)   (lbs)
AAC
Pekingese 6 solid 45 6 7/w 563 63.5 61.7 70 70
Collie 6 7/w 45 6 7/w 563 66.8 63.1 70 70
Dachshund 4 solid 45 4 7/w 881 95.5 93.4 90 90
Spaniel 4 7/w 45 4 7/w 881 101 95.4 90 90
Doberman 2 7/w 45 2 7/w 1,350 153 145.7 120 120
Malemute 1/0 19/w 60 1/0 7/w 1,990 243 234.2 160 160
ACSR NEUTRAL-MESSENGER
Setter 6 solid 45 6 ‘6/1 1.19 75 73.2 70 70
Shepherd 6 7/w 45 6 ‘6/2 1.19 78.3 74.6 70 70
Eskimo 4 solid 45 4 ‘6/3 1.86 114 111.6 90 90
Terrier 4 7/w 45 4 ‘6/4 1.86 119 113.6 90 90
Chow 2 7/w 45 2 ‘6/5 2.85 182 174.7 120 120
Bull 1/0 19/w 60 1/0 ‘6/6 4.38 289 280.3 160 160
6201 ALLOY NEUTRAL-MESSENGER
Chihuahua 6 solid 45 6 7/w 1,110 67.6 65.8 70 70
Vizsla 6 7/w 45 6 7/w 1,110 70.9 67.2 70 70
Harrier 4 solid 45 4 7/w 1,760 102 99.9 90 90
Whippet 4 7/w 45 4 7/w 1,760 107 101.9 90 90
Schnauzer 2 7/w 45 2 7/w 2,800 163 156.2 120 120
Heeler 1/0 19/w 60 1/0 7/w 4,460 259 250.8 160 160

 Triplex Service Drop-Aluminum Conductor

Code Phase Conductor Bare Neutral Messenger Weight Per Ampacity (Amps)
Name 1000 ft(lbs)
  Size Stranding Insulation Size Stranding Breaking XLP POLY XLP POLY
  AWG thickness AWG strength
    (MLS)   (lbs)
6201 ALLOY NEUTRAL-MESSENGER
Minex 6 solid 45 6 7 1,110 106.6 102.9 85 70
Hippa 6 7/w 45 6 7 1,110 113.2 105.7 85 70
Prawn 4 solid 45 4 7 1,760 158.4 154.1 115 90
Barnacles 4 7/w 45 4 7 1,760 168.3 158.2 115 90
Shrimp 2 7/w 45 2 7 2,800 253.7 239.7 150 120
Gammarus 1/0 7/w 60 1/0 7 4,460 411.7 386 205 160
Leda 1/0 19/w 60 1/0 7 4,460 402.7 386 205 160
Dungenese 2/0 7/w 60 2/0 7 5,390 506.8 476.3 235 185
Cyclops 2/0 19/w 60 2/0 7 5,390 495.3 476.3 235 185
Flustra 3/0 19/w 60 3/0 7 6,790 611.4 589.1 275 215
Lepas 4/0 19/w 60 4/0 7 8,560 757.1 730.5 315 245
6201 ALLOY REDUCED NEUTRAL-MESSENGER
Artemia 4 solid 45 6 7 1,110 141.4 137.1 115 90
Crab 4 7/w 45 6 7 1,110 151.3 141.2 115 90
Solaster 2 7/w 45 4 7 1,760 226.6 212.6 150 120
Sandcrab 1/0 7/w 60 2 7 2,800 368.8 343.1 205 160
Echinus 1/0 19/w 60 2 7 2,800 358.8 343.1 205 160
Crayfish 2/0 7/w 60 1 7 3,530 452.6 422.5 235 185
Sipho 2/0 19/w 60 1 7 3,530 441 422.5 235 185
Fulgar 3/0 19/w 60 1/0 7 4,460 543.4 521.1 275 215
Arca 4/0 19/w 60 2/0 7 5,390 671.2 644.6 315 245
AAC NEUTRAL-MESSENGER
Haiotis 6 solid 45 6 7 563 102.5 98.8 85 70
Patella 6 7/w 45 6 7 563 109.1 101.6 85 70
Fusus 4 solid 45 4 7 881 151.9 147.6 115 90
Oyster 4 7/w 45 4 7 881 161.8 151.7 115 90
Clam 2 7/w 45 2 7 1,350 243.2 229.2 150 120
Murex 1/0 7/w 60 1/0 7 1,990 395.1 369.4 205 160
Purpura 1/0 19/w 60 1/0 7 1,990 386.1 369.4 205 160
Nassa 2/0 7/w 60 2/0 7 2,510 485.8 455.3 235 185
Melita 3/0 19/w 60 3/0 19 3,310 585.2 562.9 275 215
Portunus 4/0 19/w 60 4/0 19 4,020 723.9 697.3 315 245
Nannynose 336.4 19/w 80 336 19 6,146 1160 1118 420 325
WITH FULL SIZE ACSR MESSENGER
Paludina 6 solid 45 6 ‘6/1 1,190 114 113 85 70
Voluta 6 7/w 45 6 ‘6/1 1,190 120 113 85 70
Whelk 4 solid 45 4 ‘6/1 1,860 169 165 115 90
Periwinkle 4 7/w 45 4 ‘6/1 1,860 176 172 115 90
Conch 2 7/w 45 2 ‘6/1 2,850 267 261 150 120
Neritina 1/0 7/w 60 1/0 ‘6/1 4,380 530 419 205 160
Cenia 1/0 19/w 60 1/0 ‘6/1 4,380 426 416 205 160
Runcina 2/0 7/w 60 2/0 ‘6/1 5,310 530 519 235 185
Triton 2/0 19/w 60 2/0 ‘6/1 5,310 526 514 235 185
Cherrystone 3/0 7/w 60 3/0 ‘6/1 6,620 656 643 250 200
Mursia 3/0 19/w 60 3/0 ‘6/1 6,620 650 638 250 200
Razor 4/0 7/w 60 4/0 ‘6/1 8,350 814 799 315 245
Zuzara 4/0 19/w 60 4/0 ‘6/1 8,350 805 792 315 245
Limpet 336.4 19/w 80 336 ‘6/1 8,680 1209 1167 420 325
WITH ACSR REDUCED SIZE MESSENGER
Scallop 4 Solid 45 6 ‘6/1 1,190 148 144 115 90
Strombus 4 7/w 45 6 ‘6/1 1,190 158 148 115 90
Cockle 2 7/ w 45 4 ‘6/1 1,860 233 227 150 120
Janthina 1/0 7/ w 60 2 ‘6/1 2,850 376 365 205 160
Ranella 1/0 19/ w 60 2 ‘6/1 2,850 372 362 205 160

Quadruplex Service Drop-Aluminum Conductor

Code Phase Conductor Bare Neutral Messenger Weight Per Rating(Amps)
Name 1000 ft(lbs)
  Size Strand Insulation Size Strand Breaking XLP POLY XLP POLY
  AWG thickness AWG strength
    (MLS)   (lbs)
AAC NEUTRAL-MESSNGER
Clydesdale 4 Solid 45 4 7 881 208 201.8 100 80
Pinto 4 7/w 45 4 7 881 223 207.9 100 80
Mustang 2 7/w 45 2 7 1,350 333 312.6 135 105
Criollo 1/0 19/w 60 1/0 7 1,990 529 504.5 180 140
Percheron 2/0 19/w 60 2/0 7 2,510 649 620.5 205 160
Hanoverian 3/0 19/w 60 3/0 19 3,310 799 765.6 235 185
Oldenburg 4/0 19/w 60 4/0 19 4,020 986 946.7 275 210
Lippizaner 336.4 19/w 80 336.4 19 6,146 1,546 1,519.20 370 280
ACSR NEUTRAL-MESSNGER
Morochuca 6 Solid 45 6 ‘6/1 1,190 152 147.4 75 60
Chola 6 7/w 45 6 ‘6/1 1,190 162 151.7 75 60
Morgan 4 Solid 45 4 ‘6/1 1,860 226 220 100 80
Hackney 4 7/w 45 4 ‘6/1 1,860 241 226.1 100 80
Palomino 2 7/w 45 2 ‘6/1 2,850 362 342.6 135 105
Costena 1/0 19/w 60 1/0 ‘6/1 4,380 575 550.6 180 140
Grullo 2/0 19/w 60 2/0 ‘6/1 5,310 707 678.7 205 160
Suffolk 3/0 19/w 60 3/0 ‘6/1 6,620 872 838.9 235 185
Appaloosa 4/0 19/w 60 4/0 ‘6/1 8,350 1079 1039.2 275 210
Bronco 336.4 19/w 80 336.4 ’18/1 8,580 1613 1568.2 370 280
Gelding 336.4 19/w 80 4/0 ‘6/1 8,350 1548 1494.3 370 280
 
6201 ALLOY NEUTRAL-MESSENGER
Bay 6 Solid 45 6 7 1,110 145 140 75 60
French Coach 6 7/w 45 6 7 1,110 155 144.3 75 60
German Coach 4 Solid 45 4 7 1,760 214 208.3 100 80
Arabian 4 7/w 45 4 7 1,760 229 214.4 100 80
Belgian 2 7/w 45 2 7 2,800 344 323.1 135 105
Shetland 1/0 19/w 60 1/0 7 4,460 546 521.1 180 140
Thoroughbred 2/0 19/w 60 2/0 7 5,390 670 641.5 205 160
Trotter 3/0 19/w 60 3/0 7 6,790 825 791.8 235 185
Walking  4/0 19/w 60 4/0 7 8,560 1019 979.7 275 210

TYPE TWO 0.6/1kv Aluminum Core Aerial Bundled Cable ABC Cable
Standards:
GB12527-91,IEC502, BS7870-5
Other standards such as BS, DIN, and ICEA upon request
Constructions:
Conductor: Round, stranded and compacted aluminum conductor
Insulation: HDPE, XLPE, PVC
Application:
Aerial Bunch Cables are a compromise construction between Power cables and Overhead conductors. It is preferred to use ABC cables instead of uninsulated conductors at low voltage networks. ABC cables are especially used in areas where the cost of underground networks is expensive and also for the electrification of rural areas like villages. Bundles can include one or two additional conductors for public lighting and control pairs.
Specifications:
 

Cross Section of Conductor  Min.Nos. of Wires for Conductor Insulation Thickness Average Max. O.D.per Single-core  Max.Conductor Resistance at 20ºC  Min Insulated Resistance at Rated Working Temperature Cable Tensile Breaking Force
(mm2) (mm) (mm) (mm) (Ω/km) (MΩ.km)
             
2×10 6 1 6.5×13.0 3.08 0.0067 0.67 1650
2×16 6 1.2 8.0×16.0 1.91 0.0065 0.65 2512
2×25 6 1.2 9.4×18.8 1.2 0.0054 0.54 3762
2×35 6 1.4 11.0×22.0 0.868 0.0054 0.54 5177
2×50 6 1.4 12.3×24.6 0.641 0.0046 0.46 7011
2×70 12 1.4 14.1×28.2 0.443 0.004 0.4 10354
2×95 15 1.6 16.5×33.0 0.32 0.0039 0.39 13727
2×120 15 1.6 18.1×36.2 0.252 0.0035 0.35 17339
2×150 15 1.8 20.2×40.4 0.206 0.0035 0.35 21033
2×185 30 2 22.5×45.0 0.164 0.0035 0.35 26732
2×240 30 2.2 25.6×51.2 0.125 0.0034 0.34 34679
4×10 6 1 6.5×26.0 3.08 0.0067 0.67 1650
4×16 6 1.2 8.0×32.0 1.91 0.0065 0.65 2512
4×25 6 1.2 9.4×37.6 1.2 0.0054 0.54 3762
4×35 6 1.4 11.0×44.0 0.868 0.0054 0.54 5177
4×50 6 1.4 12.3×49.2 0.641 0.0046 0.46 7011
4×70 12 1.4 14.1×56.4 0.443 0.004 0.4 10354
4×95 15 1.6 16.5×66.0 0.32 0.0039 0.39 13727
4×120 15 1.6 18.1×72.4 0.252 0.0035 0.35 17339
4×150 15 1.8 20.2×80.8 0.206 0.0035 0.35 21033
4×185 30 2 22.5×90.0 0.164 0.0035 0.35 26732
4×240 30 2.2 25.6×102.4 0.125 0.0034 0.34 3467

=========================================================

We are China Electric 0.6/1kv Power Aluminum Conductor XLPE Insulated Overhead Aerial Bundle Cable, Duplex/Triple/Quadruplex Service Drop/Urd/ABC Wire manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular ABC Cable Products

ABC Cable, Insulated Aerial Cable, Aerial Bundled Cable

AAAC Conductor Service Drop Cable Twisted Aluminum Overhead ABC Cable

ABC Cable 0.6/1 Kv, 4c X 70 mm2, Al/XLPE for Overhead

High Quality Aluminio Overhead Insualted ABC Cable to Peru Mexico Price List

Triplex Service Drop ACSR Neutral Conductor Strombus

Al Conductor Twisted PVC/XLPE/PE Material ABC Cable on Sale

Popular huatongcables Products

American UL62 Portable Cord Cable So/Sow/Soow/Sjoow

PVC Round Wire 500mcm Single Core 4AWG Cu Str 500kcmil UL Thhn

UL44 Aluminum Xhhw Xhh Xhw Cable 600V Cable

3 Tinned Wire Rneda Drum 50mm2 China Drailing Cable Type61

H07rn-F Cable 3G1.5 mm2 450/750V

PVC cUL 600V Teck90-Hl Acwu90 Armoured 16AWG 14AWG Teck90 Control Teck Cable

Popular Overhead Cable Products

ACSR Rabbit Dog 6/1/3.35mm BS215-Bare Overhead Conductor

0.6/1kv Duplex Triplex Quadruplex Aerial Bundled Cable ABC Cable

Aluminum Conductor PE/XLPE/PVC Insulation 1X50mm2 Aluminum Sac Cable Service Drop Cable Overhead Cable

Aluminum Conductor ABC Cable PE or XLPE or PVC Insulated Overhead Aerial Wire

Duplex Service Drop 2X16sqmm 0.6/1kv XLPE Insulated ABC Cable

Aluminum Alloy AAC Conductor 3/0 AWG ASTM Standard

Popular Power Cable Products

High Quality XLPE Insulated Power Cable

Electrical Wire and Cable BV/BVVB.

Aerial Bundled Al ABC Cable Overhead Insulated Cables Distribution Electrical Line

Aluminum Overhead Line Conductor (ACSR conductor)

3 Core 150mm2 Copper Conductor XLPE Insulation 15kv Medium Voltage Cable

Mv 15kv XLPE Insulation HDPE Sheath Covered Aerial Tree Wire ACSR Conductor

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION