Factory Price Duplex Service Drop Cable ABC Cable 4 AWG Eskimo
Factory Price Duplex Service Drop Cable ABC Cable 4 AWG Eskimo image
Get Latest Price Request a quote
Quick Details
Product Details
Applications
a. Duplex Service Drop
Application:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75°C maximum.
b. Triplex Service Drop
Application: To supply power from the utility’s lines to the consumer’s weatherhead. For service at 600 volt or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene insulation 90°C maximum for crosslinked insulation.
c. Quadruplex Service Drop.
Used to supply 3 phase power, usually from a polemounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulation 90°C maximum for crosslinked polyethylene(XLPE) insulated conductors.
Standard
ANSI/ICEA S-76-474, NF C 33-209, AS3560-1-2000, IEC 60228, and ect.
Specification
Duplex service drop | |||||||||
Code Name | Phase conductor | Bare Neutral Message | Nominal Weight ( kg/km ) | Allowable Ampacity | |||||
Size & No.of wires | Insulation Thick(mm) | Nominal Diameter (mm) | Size & No.of wires | Rated Strength (kg) | XLPE | Aluminum | ( A ) | ||
Bare | OD | ||||||||
AAC | |||||||||
Pekingese | 6-Solid | 1.14 | 4.1 | 6.4 | 6-7 | 255 | 20.8 | 72.9 | 78 |
Collie | 6-7 | 1.14 | 4.6 | 6.9 | 6-7 | 255 | 23.8 | 72.9 | 78 |
Cocker | 6-7 | 1.52 | 4.6 | 7.7 | 6-7 | 255 | 32.7 | 72.9 | 78 |
Dachshund | 4-Solid | 1.14 | 5.2 | 7.5 | 6-7 | 400 | 26.8 | 114.6 | 103 |
Spaniel | 4-7 | 1.14 | 5.9 | 8.2 | 6-7 | 400 | 29.8 | 116.1 | 103 |
Cairn | 4-7 | 1.52 | 5.9 | 8.9 | 6-7 | 400 | 40.2 | 116.1 | 103 |
Doberman | 2-7 | 1.14 | 7.4 | 9.7 | 2-7 | 612 | 38.7 | 184.5 | 136 |
Airedale | 1-19 | 1.52 | 8.4 | 11.5 | 1-7 | – | 56.5 | 233.6 | 158 |
Basset | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-7 | 903 | 64 | 294.7 | 182 |
Malemure | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-7 | 903 | 64 | 294.7 | 182 |
AAAC | |||||||||
Chihuahua | 6-Solid | 1.14 | 4.1 | 6.4 | 6-7 | 499 | 20.8 | 72.9 | 78 |
VIzsla | 6-7 | 1.14 | 4.6 | 6.9 | 6-7 | 499 | 23.8 | 72.9 | 78 |
Harrier | 4-Solid | 1.14 | 5.2 | 7.5 | 4-7 | 798 | 26.8 | 116.1 | 103 |
Whippet | 4-7 | 1.14 | 5.9 | 8.2 | 4-7 | 798 | 29.8 | 116.1 | 103 |
Schnauzer | 2-7 | 1.14 | 7.4 | 9.7 | 2-7 | 1270 | 38.7 | 184.5 | 136 |
Afghan | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-7 | 2023 | 64 | 296.1 | 182 |
Hocler | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-7 | 2023 | 64 | 296.1 | 182 |
ACSR | |||||||||
Setter | 6-Solid | 1.14 | 4.1 | 6.4 | 6/6/01 | 540 | 20.8 | 72.9 | 78 |
Shepherd | 6-7 | 1.14 | 4.6 | 6.9 | 6/6/01 | 540 | 23.8 | 72.9 | 78 |
Retriever | 6-7 | 1.52 | 4.6 | 7.7 | 6/6/01 | 540 | 32.7 | 72.9 | 78 |
Eskimo | 4-Solid | 1.14 | 5.2 | 7.5 | 4/6/01 | 844 | 26.8 | 114.6 | 103 |
Terrier | 4-7 | 1.14 | 5.9 | 8.2 | 4/6/01 | 844 | 29.8 | 116.1 | 103 |
Yorkshirc | 4-7 | 1.52 | 5.9 | 8.9 | 4/6/01 | 844 | 40.2 | 116.1 | 103 |
Chow | 2-7 | 1.14 | 7.4 | 9.7 | 2/6/01 | 1293 | 38.7 | 184.5 | 136 |
Labrador | 1-19 | 1.52 | 8.4 | 11.5 | 1/6/01 | 1610 | 56.5 | 233.6 | 158 |
Bloodhound | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-6/1 | 1987 | 64 | 294.7 | 182 |
Bull | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-6/1 | 1987 | 64 | 294.7 | 182 |
DESCRIPTION | INSULATED PHASE CONDUCTORS | Average Insulation Thickness | ||||
Type | Nominal cross-section area | Wire Number in the conductor | Max. resistance at 20 o C | Average diameter of conductors | Rated Strength | |
mm 2 | Number | Ohm/km | Mini mm Max. mm | Mini KN | mm | |
PHASE, NEUTRAL, and PUBLIC LIGHTING |
16 | 7 | 1.910 | 4.6 5.1 | 1.9 | 1.2 |
25 | 7 | 1.200 | 5.8 6.3 | 3.0 | 1.4 | |
35 | 7 | 0.868 | 6.8 7.3 | – | 1.6 | |
50 | 7 | 0.641 | 7.9 8.4 | – | 1.6 | |
70 | 12 | 0.443 | 9.7 10.2 | – | 1.8 | |
95 | 19 | 0.320 | 11.0 12.0 | – | 1.8 | |
120 | 19 | 0.253 | 12.0 13.1 | – | 1.8 | |
150 | 19 | 0.206 | 13.9 15.0 | – | 1.7 | |
PORTER | 54.6 | 7 | 0.630 | 9.2 9.6 | 16.6 | 1.6 |
70 | 7 | 0.500 | 10.0 10.2 | 20.5 | 1.5 | |
95 | 19 | 0.343 | 12.2 12.9 | 27.5 | 1.6 |
We are China Factory Price Duplex Service Drop Cable ABC Cable 4 AWG Eskimo manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Cable 4 AWG Eskimo Products
Popular Duplex 4 AWG Eskimo Cable Products
Popular Factory Price Duplex Service Drop Products
Factory Price Duplex Service Drop Cable ABC Cable 6 AWG Chihuahua
Factory Price Duplex Service Drop Cable ABC Cable 6AWG Collie
Factory Price Duplex Service Drop Cable ABC Cable 4 AWG Yorkshirc
Factory Price Duplex Service Drop Cable ABC Cable 4 AWG Terrier
Factory Price Duplex Service Drop Cable ABC Cable 6AWG Pekingese
Factory Price Duplex Service Drop Cable ABC Cable 4 AWG Harrier
Popular huatongcable Products
Alumo-Clad Steel 7 N0 9AWG. Acs
Aluminium Conductor Steel Supported Acss ASTM B856 for Overhead Distribution and Transmission Lines
BV Wire Single Strand Copper Wire Green Yellow Earth Wire
IEC 60227 Copper Conductor PVC Insulation Electric Wire RV 4.0mm2
ACSR Conductor (Aluminum Conduct Steel Reinforced) ACSR Dove
Medium Voltage PVC Insulated Steel Wire Armoured Power Cable
Tags: Cable 4 AWG Eskimo, Duplex 4 AWG Eskimo Cable, Factory Price Duplex Service Drop, huatongcable