Factory Supply AAAC Conductor Cable for Overhead Transmission
Factory Supply AAAC Conductor Cable for Overhead Transmission image
Get Latest Price Request a quote
Basic Info.
Product Description
Applications
Used as bare overhead conductor for primary and secondary distribution.
Designed utilizing a high-strength aluminum alloy to achieve a high strength-to-weight ratio; affords better sag characteristics.
Aluminum alloy gives AAAC higher resistance to corrosion than ACSR.
standard
BS EN50183,IEC 61089, ASTM B399,BS 3242, DIN 48204,GB/T1179-2008
specification
ASTM B399
Code Name | Area | Size & Stranding of ACSR with Equal Diameter | No. & Diameter of wires | Overall Diameter | Weight | Nominal Breaking Load | ||
Nominal | Actual | |||||||
MCM | mm2 | AWG or MCM | Al/Steel | mm | mm | kg/km | kN | |
Akron | 30.58 | 15.48 | 6 | 6/1 | 7/1.68 | 5.04 | 42.7 | 4.92 |
Alton | 48.69 | 24.71 | 4 | 6/1 | 7/2.12 | 6.35 | 68 | 7.84 |
Ames | 77.47 | 39.22 | 2 | 6/1 | 7/2.67 | 8.02 | 108 | 12.45 |
Azusa | 123.3 | 62.38 | 1/0 | 6/1 | 7/3.37 | 10.11 | 172 | 18.97 |
Anaheim | 155.4 | 78.65 | 2/0 | 6/1 | 7/3.78 | 11.35 | 217 | 23.93 |
Amherst | 195.7 | 99.22 | 3/0 | 6/1 | 7/4.25 | 12.75 | 273 | 30.18 |
Alliance | 246.9 | 125.1 | 4/0 | 6/1 | 7/4.77 | 14.31 | 345 | 38.05 |
Butte | 312.8 | 158.6 | 266.8 | 7/26 | 19/3.26 | 16.3 | 437 | 48.76 |
Canton | 394.5 | 199.9 | 336.4 | 7/26 | 19/3.66 | 18.3 | 551 | 58.91 |
Cairo | 465.4 | 235.8 | 397.5 | 7/26 | 19/3.98 | 19.88 | 650 | 69.48 |
Darien | 559.5 | 283.5 | 477 | 7/26 | 19/4.36 | 21.79 | 781 | 83.52 |
Elgin | 652.4 | 330.6 | 556.5 | 7/26 | 19/4.71 | 23.54 | 911 | 97.42 |
Flint | 740.8 | 375.3 | 636 | 7/26 | 37/3.59 | 25.16 | 1035 | 108.21 |
Greely | 927.2 | 469.8 | 795 | 7/26 | 37/4.02 | 28.14 | 1295 | 135.47 |
IEC 61089
Code Number | A2 Conductor | A3 Conductor | Max.D.C. Resistance of Conductor at 20ºC | ||||||||
Number of Wires | Diameter of Wires | Diameter of Conductor | Approx. Weight | Rated Strength | Number of Wires | Diameter of Wires | Diameter of Conductor | Approx. Weight | Rated Strength | ||
mm² | – | mm | mm | kg/km | daN | – | mm | mm | kg/km | daN | Ω/km |
16 | 7 | 1.83 | 5.49 | 50.4 | 5.43 | 7 | 1.84 | 5.52 | 50.8 | 6.04 | 1.7896 |
25 | 7 | 2.29 | 6.87 | 78.7 | 8.49 | 7 | 2.3 | 6.9 | 79.5 | 9.44 | 1.1453 |
40 | 7 | 2.89 | 8.67 | 125.9 | 13.58 | 7 | 2.91 | 8.73 | 127.1 | 15.1 | 0.7158 |
63 | 7 | 3.63 | 10.8 | 198.3 | 21.39 | 7 | 3.65 | 10.95 | 200.2 | 23.06 | 0.4545 |
100 | 19 | 2.78 | 13.9 | 316.3 | 33.95 | 19 | 2.79 | 13.95 | 319.3 | 37.76 | 0.2877 |
125 | 19 | 3.1 | 15.5 | 395.4 | 42.44 | 19 | 3.12 | 15.6 | 399.2 | 47.2 | 0.2302 |
160 | 19 | 3.51 | 17.55 | 506.1 | 54.32 | 19 | 3.53 | 17.65 | 511 | 58.56 | 0.1798 |
200 | 19 | 3.93 | 19.65 | 623.7 | 67.91 | 19 | 3.95 | 19.75 | 638.7 | 73.2 | 0.1439 |
250 | 19 | 4.39 | 21.95 | 790.8 | 84.68 | 19 | 4.41 | 22.05 | 798.4 | 91.5 | 0.1151 |
315 | 37 | 3.53 | 24.71 | 998.9 | 106.95 | 37 | 3.55 | 24.85 | 1008.4 | 115.29 | 0.0916 |
400 | 37 | 3.98 | 27.86 | 1268.4 | 135.81 | 37 | 4 | 28 | 1280.5 | 146.4o | 0.0721 |
450 | 37 | 4.22 | 29.54 | 1426.9 | 152.79 | 37 | 4.24 | 29.68 | 1440.5 | 164.7 | 0.0641 |
500 | 37 | 4.45 | 31.15 | 1585.5 | 169.76 | 37 | 4.47 | 31.29 | 1600.6 | 183.oo | 0.0577 |
560 | 61 | 3.67 | 33.03 | 1778.4 | 190.14 | 61 | 3.69 | 33.21 | 1795.3 | 204.95 | 0.0516 |
630 | 61 | 3.89 | 35.01 | 2000.7 | 213.9 | 61 | 3.91 | 35.19 | 2019.8 | 230.58 | 0.0458 |
710 | 61 | 4.13 | 37.17 | 2254.8 | 241.07 | 61 | 4.15 | 37.35 | 2276.2 | 259.86 | 0.0407 |
800 | 61 | 4.38 | 39.42 | 2540.6 | 271.62 | 61 | 4.4 | 39.6 | 2564.8 | 282.8 | 0.0361 |
900 | 91 | 3.81 | 41.91 | 2861.1 | 305.58 | 91 | 3.83 | 42.13 | 2888.3 | 329.4 | 0.0321 |
1000 | 91 | 4.01 | 44.11 | 3179 | 339.53 | 91 | 4.03 | 44.33 | 3209.3 | 366 | 0.0289 |
1120 | 91 | 4.25 | 46.75 | 3560.5 | 380.27 | 91 | 4.27 | 46.97 | 3594.4 | 409.92 | 0 0258 |
1250 | 91 | 4.49 | 49.39 | 3973.7 | 424.41 | – | – | – | – |
BS EN50183
Code Name | Calculated | No..Dia.of Wires | Overall Diameter | Weight | Rated Strength |
Cross Section | |||||
mm² | No./mm | mm | kg/km | kN | |
Box | 18.8 | 7/1.85 | 5.55 | 51.4 | 5.55 |
Acacia | 23.8 | 7/2.08 | 6.24 | 64.9 | 7.02 |
Almond | 30.1 | 7/2.34 | 7.02 | 82.2 | 8.88 |
Cedar | 35.5 | 7/2.54 | 7.62 | 96.8 | 10.46 |
Deodar | 42.2 | 7/2.77 | 8.31 | 115.2 | 12.44 |
Fir | 47.8 | 7/2.95 | 8.85 | 130.6 | 14.11 |
Hazel | 59.9 | 7/3.30 | 9.9 | 163.4 | 17.66 |
Pine | 71.6 | 7/3.61 | 10.8 | 195.6 | 21.14 |
Holly | 84.1 | 7/3.91 | 11.7 | 229.5 | 24.79 |
Willow | 89.7 | 7/4.04 | 12.1 | 245,0 | 26.47 |
Oak | 118.9 | 7/4.65 | 14 | 324.5 | 35.07 |
Mulberry | 150.9 | 19/3.18 | 15.9 | 414.3 | 44.52 |
Ash | 180.7 | 19/3.48 | 17.4 | 496.1 | 53.31 |
Elm | 211 | 19/3.76 | 18.8 | 579.2 | 62.24 |
Poplar | 239.4 | 37/2.87 | 20.1 | 659.4 | 70.61 |
Sycamore | 303.2 | 37/3.23 | 22.6 | 835.2 | 89.4 |
Upas | 362.1 | 37/3.53 | 24.7 | 997.5 | 106.82 |
Yew | 479 | 37/4.06 | 28.4 | 1319.6 | 141.31 |
Totara | 498.1 | 37/4.14 | 29 | 1372.1 | 146.93 |
Rubus | 586.9 | 61/3.50 | 31.5 | 1622 | 173.13 |
Sorbus | 659.4 | 61/3.71 | 33.4 | 1822.5 | 194.53 |
Araucaria | 821.1 | 61/4.14 | 37.3 | 2269.4 | 242.24 |
Redwood | 996.2 | 61/4.56 | 41 | 2753.2 | 293.88 |
Code number | Calculated area | Number of wires | Diameter of wire | Overall diameter of conductor | Linear mass | Rated tensile strength | Max. DC resistance at 20ºC |
mm2 | mm2 | mm | mm | kg/km | daN | Ω/km | |
16 | 15.89 | 7 | 1.7 | 5.1 | 43 | 444 | 2.091 |
25 | 24.25 | 7 | 2.1 | 6.3 | 66 | 677 | 1.3703 |
35 | 34.36 | 7 | 2.5 | 7.5 | 94 | 960 | 0.9669 |
50 | 49.48 | 7 | 3 | 9 | 135 | 1382 | 0.6714 |
50 | 48.35 | 19 | 1.8 | 9 | 133 | 1350 | 0.6905 |
70 | 65.81 | 19 | 2.1 | 10.5 | 181 | 1838 | 0.5073 |
95 | 93.27 | 19 | 2.5 | 12.5 | 256 | 2605 | 0.3579 |
120 | 116.99 | 19 | 2.8 | 14 | 322 | 3268 | 0.2854 |
150 | 147.11 | 37 | 2.25 | 15.8 | 406 | 4109 | 0.2274 |
185 | 181.62 | 37 | 2.5 | 17.5 | 500 | 5073 | 0.1842 |
240 | 242.54 | 61 | 2.25 | 20.3 | 670 | 6774 | 0.1383 |
300 | 299.43 | 61 | 2.5 | 22.5 | 827 | 8363 | 0.112 |
400 | 400.14 | 61 | 2.89 | 26 | 1104 | 11176 | 0.0838 |
500 | 499.63 | 61 | 3.23 | 29.1 | 1379 | 13960 | 0.06709 |
625 | 626.2 | 91 | 2.96 | 32.6 | 1732 | 17490 | 0.054 |
800 | 802.09 | 91 | 3.35 | 36.9 | 2218 | 22402 | 0.0418 |
1000 | 999.71 | 91 | 3.74 | 41.1 | 2767 | 27922 | 0.0335 |
We are China Factory Supply AAAC Conductor Cable for Overhead Transmission manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular All Aluminum Alloy Conductor Products
Customized All Aluminum Alloy Conductor AAAC Overhead Electric Wire AAC
AAAC Conductor All Aluminum Alloy Conductor ACSR /AAC/AAAC Conductor Cable
ASTM DIN IEC Standard All Aluminum Alloy Conductor AAAC Bare Electric Wire
Bare AAC AAAC Overhead Stranded Electric Wire
AAAC All Aluminum Alloy Conductor Bare Conductor Cable Conductor
Aluminum Alloy AAAC Bare Stranded Conductor Cable Wire
Popular Bare Cable Products
Overhead Electrical AAC Aluminum Conductor
All Aluminum Alloy Conductor 50mm 70mm 95mm 120mm 150mm AAAC Conductor
Best Price Bare Cable AAC Aluminum Alloy Conductor Overhead
Good Quality AAC AAAC Conductor Overhead Electric Cables ASTM B-231 25mm 35mm 50mm 70mm
Hot Sale AAAC Bare Aluminum Stranded Conductor Cable Wire AAC/AAAC
Popular Factory Supply AAAC Conductor Cable for Overhead Transmission Products
Popular kingyear Products
25mm2 35mm2 3 Copper Core Welding Cable
Quadruplex Aluminum Conductor Service Drop ABC Cable
ASTM Standard Kvvr/Kvvrp/Zr-Kvvp/Zr-Kvvrp Control Cable
ASTM All Aluminum Conductor AAAC AAC Acar Conductor Bare Conductor Alloy Conductor
Factory Produces 4/5 Core Unarmored Power Cables
ASTM BS 300/25mm ACSR 300mcm ACSR Ostrich
Tags: All Aluminum Alloy Conductor, Bare Cable, Factory Supply AAAC Conductor Cable for Overhead Transmission, kingyear