Fuse Link, 3 AMPS -T
Fuse Link, 3 AMPS -T image
Get Latest Price Request a quote
Quick Details
Product Details
Maximum altitude above mean sea level less than 1,000 m;
Maximum ambient air temperature 400C;
Maximum daily average ambient air temperature 300C;
Minimum ambient temperature150C; and
Maximum relative humidity 100%.
Requirements
The fuse-links and fuse-end fittings shall be of the following ratings (table below) and comply with the IEEE Std C37.4 -2016 or an equivalent international standard. The fuse- links shall be used primarily for protection of distribution transformers, laterals and sub- laterals.
The fuse links shall be capable of withstanding 125% ofthe transformer rated full load current continuously and periodic over-loads up to 150% ofthe transformer rated full load current.
The current-time characteristics of the fuse-links offered shall be submitted with the tender
Markings shall be provided on the fuse-links in accordance with ANSI/IEEE Standards.
Type | Order No. | Order No. | Rated voltage | Rated current | Length | Diameter | Breaking capacity | Min.breakk- ing current | Resistance | Power Dissipation | Weight | ||||
60N | 80N | kV | A | L, mm | D, mm | I1, kA | I3, A | R, mΩ | P, W | kg | |||||
VvP 3/7,2kV 2A 192/53 | 1607002 | 1807002 | 3/7,2 | 2 | 192 | 53 | 50 | 15 | 340 | 3 | 1.3 | ||||
VvP 3/7,2kV 4A 192/53 | 1607004 | 1807004 | 3/7,2 | 4 | 192 | 53 | 50 | 18 | 290 | 6 | 1.3 | ||||
VvP 3/7,2kV 6.3A 192/53 | 1607006 | 1807006 | 3/7,2 | 6,3 | 192 | 53 | 50 | 25 | 220 | 12 | 1.3 | ||||
VvP 3/7,2kV 10A 192/53 | 1607010 | 1807010 | 3/7,2 | 10 | 192 | 53 | 50 | 50 | 61 | 7 | 1.3 | ||||
VvP 3/7,2kV 16A 192/53 | 1607016 | 1807016 | 3/7,2 | 16 | 192 | 53 | 50 | 63 | 38 | 12 | 1.3 | ||||
VvP 3/7,2kV 20A 192/53 | 1607020 | 1807020 | 3/7,2 | 20 | 192 | 53 | 50 | 90 | 33 | 11 | 1.3 | ||||
VvP 3/7,2kV 25A 192/53 | 1607025 | 1807025 | 3/7,2 | 25 | 192 | 53 | 50 | 105 | 28 | 11 | 1.3 | ||||
VvP 3/7,2kV 31,5A 192/53 | 1607032 | 1807032 | 3/7,2 | 31,5 | 192 | 53 | 50 | 119 | 19 | 20 | 1.3 | ||||
VvP 3/7,2kV 40A 192/53 | 1607040 | 1807040 | 3/7,2 | 40 | 192 | 53 | 50 | 137 | 11 | 22 | 1.3 | ||||
VvP 3/7,2kV 50A 192/69 | 1607050 | 1807050 | 3/7,2 | 50 | 192 | 69 | 50 | 210 | 10 | 37 | 1.9 | ||||
VvP 3/7,2kV 63A 192/69 | 1607063 | 1807063 | 3/7,2 | 63 | 192 | 69 | 50 | 255 | 7 | 46 | 1.9 | ||||
VvP 3/7,2kV 80A 192/69 | 1607080 | 1807080 | 3/7,2 | 80 | 192 | 69 | 50 | 321 | 5 | 57 | 1.9 | ||||
VvP 3/7,2kV 100A 192/85 | 1607100 | 1807100 | 3/7,2 | 100 | 192 | 85 | 50 | 420 | 4 | 86 | 2.6 | ||||
VvP 3/7,2kV 125A 192/85 | 1607125 | 1807125 | 3/7,2 | 125 | 192 | 85 | 50 | 452 | 2.5 | 98 | 2.6 | ||||
VvP 3/7,2kV 160A 192/85 | 1607160 | 1807160 | 3/7,2 | 160 | 192 | 85 | 50 | 560 | 2 | 130 | 2.6 | ||||
VvP 3/7,2kV 200A 192/85 | 1607200 | 1807200 | 3/7,2 | 200 | 192 | 85 | 50 | 730 | 1.5 | 225 | 2.6 | ||||
VvP 6/12kV 2A 292/53 | 1610002 | 1810002 | 6/12 | 2 | 292 | 53 | 63 | 17 | 585 | 2 | 1.7 | ||||
VvP 6/12kV 4A 292/53 | 1610004 | 1810004 | 6/12 | 4 | 292 | 53 | 63 | 23 | 537 | 7 | 1.7 | ||||
VvP 6/12kV 6.3A 292/53 | 1610006 | 1810006 | 6/12 | 6,3 | 292 | 53 | 63 | 32 | 405 | 10 | 1.7 | ||||
VvP 6/12kV 10A 292/53 | 1610010 | 1810010 | 6/12 | 10 | 292 | 53 | 63 | 50 | 137 | 17 | 1.7 | ||||
VvP 6/12kV 16A 292/53 | 1610016 | 1810016 | 6/12 | 16 | 292 | 53 | 63 | 61 | 96 | 40 | 1.7 | ||||
VvP 6/12kV 20A 292/53 | 1610020 | 1810020 | 6/12 | 20 | 292 | 53 | 63 | 80 | 51 | 40 | 1.7 | ||||
VvP 6/12kV 25A 292/53 | 1610025 | 1810025 | 6/12 | 25 | 292 | 53 | 63 | 101 | 48 | 48 | 1.7 | ||||
VvP 6/12kV 31,5A 292/53 | 1610032 | 1810032 | 6/12 | 31,5 | 292 | 53 | 63 | 116 | 45 | 67 | 1.7 | ||||
VvP 6/12kV 40A 292/53 | 1610040 | 1810040 | 6/12 | 40 | 292 | 53 | 63 | 145 | 26 | 70 | 1.7 | ||||
VvP 6/12kV 50A 292/69 | 1610050 | 1810050 | 6/12 | 50 | 292 | 69 | 63 | 240 | 18 | 81 | 2.6 | ||||
VvP 6/12kV 63A 292/69 | 1610063 | 1810063 | 6/12 | 63 | 292 | 69 | 50 | 315 | 12 | 93 | 2.6 | ||||
VvP 6/12kV 80A 292/69 | 1610080 | 1810080 | 6/12 | 80 | 292 | 69 | 50 | 370 | 8 | 115 | 2.6 | ||||
VvP 6/12kV 100A 292/85 | 1610100 | 1810100 | 6/12 | 100 | 292 | 85 | 50 | 420 | 7 | 158 | 3.7 | ||||
VvP 6/12kV 125A 292/85 | 1610125 | 1810125 | 6/12 | 125 | 292 | 85 | 50 | 490 | 5 | 170 | 3.7 | ||||
VvP 6/12kV 160A 292/85 | 1610160 | 1810160 | 6/12 | 160 | 292 | 85 | 50 | 800 | 3 | 220 | 3.7 | ||||
VvP 6/12kV 200A 292/85 | 1610200 | 1810200 | 6/12 | 200 | 292 | 85 | 50 | 1000 | 2 | 341 | 3.7 | ||||
VvP 10/17.5kV 2А 53/367 | 1617002 | 1817002 | 10/17.5 | 2 | 367 | 53 | 50 | 16 | 980 | 4 | 2.0 | ||||
VvP 10/17.5kV 4А 53/367 | 1617004 | 1817004 | 10/17.5 | 4 | 367 | 53 | 50 | 22 | 731 | 10 | 2.0 | ||||
VvP 10/17.5kV 6.3А 53/367 | 1617006 | 1817006 | 10/17.5 | 6.3 | 367 | 53 | 50 | 30 | 550 | 13 | 2.0 | ||||
VvP 10/17.5kV 10А 53/367 | 1617010 | 1817010 | 10/17.5 | 10 | 367 | 53 | 50 | 44 | 207 | 22 | 2.0 | ||||
VvP 10/17.5kV 16А 53/367 | 1617016 | 1817016 | 10/17.5 | 16 | 367 | 53 | 50 | 62 | 117 | 55 | 2.0 | ||||
VvP 10/17.5kV 20А 53/367 | 1617020 | 1817020 | 10/17.5 | 20 | 367 | 53 | 50 | 78 | 68 | 56 | 2.0 | ||||
Recommended for You
Not exactly what you want?
Post Sourcing Request
Hot Searches
Power Fuse
Voltage Fuse
Protection Fuse
Fuse Box
Fast Fuse
We are China Fuse Link, 3 AMPS -T manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Fuse Link Products
415VAC 500VAC Slotted Wedge HRC High Breaking Capacity Jpu Fuse Link
10 Gauge Knitted Gloves with PVC Dotscotton/Polyesterunbleached/Bleached White7-11
PVC Gloves Sandy Finish blue 30cm
Popular High Voltage Fuse Products
15g Sandy Nitrile Glovesnylonblack 7-11
Outdoor High Voltage Drop-out Fuse Cutout (RW12-15KV)
Popular jgtrade1 Products
Splice Full Traction ACSR-AAAC No. 1/0 to 1/0 AWG
W, Ws Type Round Head Hung Plates
Popular Outdoor Products
Driving Gloves Made of Pigskin Leather
PVC Glovessmooth Finish Black 30cm
13G Nitrile Gloves Polyester Grey 7-11
Tags: Fuse Link, High Voltage Fuse, jgtrade1, Outdoor