High Performance 600/1000V PVC Insulated Power Cable
High Performance 600/1000V PVC Insulated Power Cable image
Get Latest Price Request a quote
Basic Info.
Product Description
Application:
With the characteristics of stable capability,advanced technology,broad material resources,low price, good flexible and easy to lay and maintain, the PVC Insulated and Sheathed Power Cable are suitable to be laid for distribution line with A.C.50HZ and rated voltage up to 6kV.
Property:
1.The long-time permissible working temperature of cable conductive core is not more than 70 °C.
2.During short circuit (max. permanent time is not more than 5 seconds), the max temperature of cable conductor is not more than 165°C.
3.The difference level of laying cable is not restricted.When laying the cable,ambient temperature is not lower than 0°C.
4.They have good chemical stability,and properties of acid resistance,alkali resistance,salt resistance,oil resistance,solvent resistance and flame resistance.rty
5.Light weight,good bending property and easy installation and maintenance.
Specification:
Standard:
IEC,BS,VDE,AS/NZS,ICEA,JIS and so on,designing and manufacturing special power cable according to the other standards required by the customer
1)600/1000V, Single Core, Circular Compacted Al or Cu/PVC/PVC Unarmoured or Armoured Power Cable
Cross Section of Conductor |
No. of Wires |
Thickness of Insulation |
Unarmoured |
Armoured |
||||||||
Thickness of Sheath |
Overall Dia. |
jpcable99.en. Weight |
Thickness of Bedding |
Thickness of Al Tape |
Thickness of Sheath |
Overall Dia. |
jpcable99.en. Weight |
|||||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
|||||||||
mm2 |
– |
mm |
mm |
mm |
kg/km |
kg/km |
mm |
mm |
mm |
mm |
kg/km |
kg/km |
1.5 |
1 |
0.8 |
1.4 |
5.8 |
– |
51 |
– |
– |
– |
– |
– |
– |
2.5 |
1 |
0.8 |
1.4 |
6.2 |
– |
64 |
– |
– |
– |
– |
– |
– |
4 |
1 |
1 |
1.4 |
7.1 |
– |
88 |
– |
– |
– |
– |
– |
– |
6 |
7 |
1 |
1.4 |
7.8 |
78 |
114 |
– |
– |
– |
– |
– |
– |
10 |
7 |
1 |
1.4 |
8.6 |
96 |
159 |
1 |
0.5 |
1.8 |
13.4 |
234 |
295 |
16 |
7 |
1 |
1.4 |
9.6 |
123 |
222 |
1 |
0.5 |
1.8 |
14.4 |
274 |
370 |
25 |
7 |
1.2 |
1.4 |
11.2 |
172 |
328 |
1 |
0.5 |
1.8 |
16 |
344 |
496 |
35 |
7 |
1.2 |
1.4 |
12.2 |
209 |
428 |
1 |
0.5 |
1.8 |
17 |
393 |
606 |
50 |
19 |
1.4 |
1.4 |
13.9 |
271 |
565 |
1 |
0.5 |
1.8 |
18.7 |
478 |
764 |
70 |
19 |
1.4 |
1.5 |
15.9 |
356 |
818 |
1 |
0.5 |
1.8 |
20.5 |
582 |
1020 |
95 |
19 |
1.6 |
1.5 |
18 |
471 |
1041 |
1 |
0.5 |
1.8 |
22.6 |
717 |
1291 |
120 |
37 |
1.6 |
1.6 |
19.6 |
563 |
1307 |
1 |
0.5 |
1.8 |
24 |
822 |
1545 |
150 |
37 |
1.8 |
1.6 |
21.3 |
684 |
1592 |
1 |
0.5 |
1.8 |
25.4 |
952 |
1857 |
185 |
37 |
2 |
1.7 |
23.9 |
840 |
1985 |
1 |
0.5 |
1.8 |
27.9 |
1136 |
2236 |
240 |
61 |
2.2 |
1.8 |
27 |
1071 |
2533 |
1 |
0.5 |
1.9 |
31 |
1404 |
2877 |
300 |
61 |
2.4 |
1.9 |
29.6 |
1317 |
3162 |
1.2 |
0.5 |
2.1 |
34.3 |
1722 |
3551 |
400 |
61 |
2.6 |
2 |
33.2 |
1666 |
4120 |
1.2 |
0.5 |
2.2 |
37.6 |
2114 |
4488 |
500 |
61 |
2.8 |
2.2 |
37.5 |
2089 |
5163 |
1.2 |
0.5 |
2.3 |
42.1 |
2592 |
5683 |
630 |
61 |
2.8 |
2.3 |
41.2 |
2581 |
6447 |
1.4 |
0.5 |
2.4 |
46.3 |
3184 |
7060 |
2)600/1000V, Multi Cores, Sectoral Compacted Al or Cu/PVC/PVC Unarmoured Power Cable
Number of Cores |
Cross-Section of Conductor |
No. Of Wires |
Thickness of Insulation |
Thickness of Sheath |
Overall Diameter |
Approx. Net Weight |
|
Al Conductor |
Cu Conductor |
||||||
– |
mm2 |
– |
mm |
mm |
mm |
kg/km |
kg/km |
Three Cores |
3×35 |
16 |
1.2 |
1.8 |
21.9 |
601 |
1280 |
3×50 |
18 |
1.4 |
1.8 |
26.5 |
829 |
1732 |
|
3×70 |
18 |
1.4 |
1.9 |
29.2 |
1067 |
2367 |
|
3×95 |
36 |
1.6 |
2 |
32.9 |
1409 |
2317 |
|
3×120 |
36 |
1.6 |
2.1 |
36.2 |
1705 |
3983 |
|
3×150 |
36 |
1.8 |
2.2 |
38.8 |
2045 |
4872 |
|
3×185 |
36 |
2 |
2.4 |
44.8 |
2596 |
6077 |
|
3×240 |
60 |
2.2 |
2.6 |
51.5 |
3353 |
7953 |
|
3×300 |
60 |
2.4 |
2.7 |
54.9 |
6069 |
9820 |
|
Four Cores with Reduced Neutral |
3×35+16 |
16-7 |
1.2-1 |
1.8 |
25.5 |
764 |
1107 |
3×50+25 |
18-16 |
1.4-1.2 |
1.9 |
28.7 |
982 |
1410 |
|
3×70+35 |
18-16 |
1.4-1.2 |
2.0 |
32 |
1278 |
1733 |
|
3×95+50 |
36-18 |
1.6-1.4 |
2.2 |
37.8 |
1711 |
2656 |
|
3×120+70 |
36-18 |
1.6-1.4 |
2.3 |
40.5 |
2065 |
3137 |
|
3×150+70 |
36-18 |
1.8-1.4 |
2.4 |
44.8 |
2480 |
3660 |
|
3×185+95 |
36-36 |
2-1.6 |
2.6 |
49.7 |
3086 |
4345 |
|
3×240+120 |
60-36 |
2.2-1.6 |
2.8 |
56 |
3894 |
5441 |
|
3×300+150 |
60-36 |
1.4-1.8 |
2.9 |
60.3 |
4834 |
6494 |
|
Four Cores |
4×25 |
16 |
1.2 |
1.8 |
22.5 |
644 |
1286 |
4×35 |
16 |
1.2 |
1.8 |
24.6 |
799 |
1696 |
|
4×50 |
18 |
1.4 |
1.8 |
28.6 |
1071 |
2275 |
|
4×70 |
18 |
1.4 |
2 |
31.6 |
1387 |
3120 |
|
4×95 |
36 |
1.6 |
2.1 |
35.9 |
1850 |
4262 |
|
4×120 |
36 |
1.6 |
2.2 |
38.8 |
2209 |
5247 |
|
4×150 |
36 |
1.8 |
2.3 |
43.1 |
2714 |
6483 |
|
4×185 |
36 |
2 |
2.5 |
48.7 |
3403 |
8045 |
|
4×240 |
60 |
2.2 |
2.7 |
53.6 |
4290 |
10422 |
|
4×300 |
60 |
2.4 |
2.9 |
58.8 |
5302 |
12969 |
3)600/1000V, Multi Cores, Circular Compacted Al or Cu/PVC/PVC Unarmoured Power Cable
Number of Cores |
Cross-Section of Conductor |
No. Of Wires |
Thickness of Insulation |
Thickness of Sheath |
Overall Diameter |
Approx. Net Weight |
||
Al Conductor |
Cu Conductor |
|||||||
– |
mm2 |
– |
mm |
mm |
mm |
kg/km |
kg/km |
|
Three Cores |
3×10 |
7 |
1 |
1.8 |
16.6 |
281 |
465 |
|
3×16 |
7 |
1 |
1.8 |
18.7 |
387 |
679 |
||
3×25 |
7 |
1.2 |
1.8 |
22.2 |
536 |
996 |
||
3×35 |
7 |
1.2 |
1.8 |
24.4 |
665 |
1311 |
||
3×50 |
19 |
1.4 |
1.9 |
28.1 |
863 |
1729 |
||
3×70 |
19 |
1.4 |
2 |
32.3 |
1153 |
2480 |
||
3×95 |
19 |
1.6 |
2.1 |
37.1 |
1563 |
3301 |
||
3×120 |
37 |
1.6 |
2.3 |
40.4 |
1850 |
4040 |
||
3×150 |
37 |
1.8 |
2.4 |
43.9 |
2258 |
5000 |
||
3×185 |
37 |
2 |
2.5 |
49.2 |
2819 |
6151 |
||
3×240 |
61 |
2.2 |
2.8 |
55.9 |
3577 |
8040 |
||
3×300 |
61 |
2.4 |
3 |
62.1 |
4413 |
9955 |
||
3×400 |
61 |
2.6 |
3.2 |
69.3 |
5512 |
12705 |
||
Four Cores |
4×10 |
7 |
1 |
1.8 |
18.1 |
343 |
589 |
|
4×16 |
7 |
1 |
1.8 |
20.5 |
487 |
874 |
||
4×25 |
7 |
1.2 |
1.8 |
24.3 |
677 |
1291 |
||
4×35 |
7 |
1.2 |
1.8 |
26.8 |
821 |
1681 |
||
4×50 |
19 |
1.4 |
2 |
31.2 |
1118 |
2273 |
||
4×70 |
19 |
1.4 |
2.1 |
35.8 |
1494 |
3264 |
||
4×95 |
19 |
1.6 |
2.3 |
41.2 |
1993 |
4312 |
||
4×120 |
37 |
1.6 |
2.4 |
44.8 |
2370 |
5291 |
||
4×150 |
37 |
1.8 |
2.5 |
48.7 |
2959 |
6615 |
||
4×185 |
37 |
2 |
2.7 |
54.7 |
3601 |
8044 |
||
4×240 |
61 |
2.2 |
3 |
62.1 |
4596 |
10547 |
||
4×300 |
61 |
2.4 |
3.2 |
69.1 |
5614 |
13004 |
4)600/1000V, Multi Cores, Sectoral Compacted Al or Cu/PVC/PVC Armoured Power Cable
Cross Section of Conductor |
No. of Wires |
Thickness of Insulation |
Thickness of Inner Sheath |
Thickness of Steel Tape |
No./Dia. Of Steel Wires |
Thickness of Sheath |
Overall Diameter |
Approx. Net Weight |
||||||
STA |
SWA |
|||||||||||||
STA |
SWA |
STA |
SWA |
STA |
SWA |
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
|||||
mm2 |
– |
mm |
mm |
mm |
No./mm |
mm |
mm |
mm |
mm |
kg/km |
kg/km |
kg/km |
kg/km |
|
Three Cores |
||||||||||||||
3×35 |
16 |
1.2 |
1 |
0.2 |
38/1.6 |
1.8 |
1.9 |
24.7 |
28.2 |
912 |
1591 |
1447 |
2126 |
|
3×50 |
18 |
1.4 |
1 |
0.2 |
46/1.6 |
1.9 |
2 |
29.3 |
32.8 |
1202 |
2105 |
1842 |
2745 |
|
3×70 |
18 |
1.4 |
1.2 |
0.2 |
41/2.0 |
2.0 |
2.2 |
32.5 |
37.1 |
1520 |
2820 |
2475 |
3775 |
|
3×95 |
36 |
1.6 |
1.2 |
0.5 |
46/2.0 |
2.1 |
2.3 |
36.5 |
40.8 |
2241 |
4049 |
2989 |
4797 |
|
3×120 |
36 |
1.6 |
1.2 |
0.5 |
50/2.0 |
2.2 |
2.4 |
39.8 |
44.1 |
2617 |
4895 |
3435 |
5713 |
|
3×150 |
36 |
1.8 |
1.2 |
0.5 |
43/2.5 |
2.3 |
2.5 |
42.4 |
47.8 |
3019 |
5846 |
4258 |
7085 |
|
3×185 |
36 |
2 |
1.4 |
0.5 |
50/2.5 |
2.5 |
2.7 |
48.8 |
54.2 |
3783 |
7264 |
5219 |
8700 |
|
3×240 |
60 |
2.2 |
1.6 |
0.5 |
58/2.5 |
2.8 |
2.9 |
56 |
61.3 |
4790 |
9390 |
6444 |
11044 |
|
3×300 |
60 |
2.4 |
1.6 |
0.5 |
61/2.5 |
2.9 |
3.1 |
59.3 |
64.7 |
5594 |
11345 |
7458 |
13209 |
|
Four Cores with Reduced Neutral |
||||||||||||||
3×35+16 |
16-7 |
1.2-1 |
1 |
0.2 |
43/1.6 |
1.9 |
2 |
28.5 |
31.3 |
1107 |
1528 |
1705 |
2469 |
|
3×50+25 |
18-16 |
1.4-1.2 |
1.2 |
0.2 |
40/2.0 |
2.0 |
2.1 |
32.2 |
36.1 |
1410 |
2044 |
2326 |
3388 |
|
3×70+35 |
18-16 |
1.4-1.2 |
1.2 |
0.2 |
44/2.0 |
2.0 |
2.2 |
35.2 |
39.3 |
1733 |
2801 |
2762 |
4285 |
|
3×95+50 |
36-18 |
1.6-1.4 |
1.2 |
0.5 |
41/2.5 |
2.3 |
2.5 |
42.5 |
46.3 |
2656 |
3820 |
3816 |
5925 |
|
3×120+70 |
36-18 |
1.6-1.4 |
1.4 |
0.5 |
45/2.5 |
2.4 |
2.6 |
45.6 |
49.4 |
3137 |
4777 |
4391 |
7103 |
|
3×150+70 |
36-18 |
1.8-1.4 |
1.4 |
0.5 |
49/2.5 |
2.6 |
2.7 |
49.9 |
53.6 |
3660 |
5709 |
5043 |
8272 |
|
3×185+95 |
36-36 |
2-1.6 |
1.4 |
0.5 |
55/2.5 |
2.6 |
2.9 |
54.5 |
58.5 |
3445 |
7171 |
5902 |
9987 |
|
3×240+120 |
60-36 |
2.2-1.6 |
1.6 |
0.5 |
62/2.5 |
2.9 |
3.1 |
61.6 |
65.3 |
5441 |
9272 |
7174 |
12552 |
|
3×300+150 |
60-36 |
1.4-1.8 |
1.6 |
0.5 |
67/2.5 |
3.8 |
3.2 |
65.9 |
69.6 |
6494 |
11546 |
8355 |
15067 |
|
Four Cores |
||||||||||||||
4×25 |
16 |
1.2 |
1 |
0.2 |
38/1.6 |
1.8 |
1.9 |
25.3 |
28 |
934 |
1576 |
1450 |
2092 |
|
4×35 |
16 |
1.2 |
1 |
0.2 |
41/1.6 |
1.8 |
1.9 |
27.4 |
30.2 |
1120 |
2017 |
1681 |
2578 |
|
4×50 |
18 |
1.4 |
1 |
0.2 |
39/2.0 |
2 |
2.1 |
31.6 |
35.6 |
1454 |
2658 |
2336 |
3540 |
|
4×70 |
18 |
1.4 |
1.2 |
0.5 |
43/2.0 |
2.1 |
2.2 |
36.3 |
39 |
2183 |
3916 |
2840 |
4573 |
|
4×95 |
36 |
1.6 |
1.2 |
0.5 |
50/2.0 |
2.3 |
2.4 |
40.6 |
44.1 |
2748 |
5160 |
3545 |
5957 |
|
4×120 |
36 |
1.6 |
1.4 |
0.5 |
42/2.5 |
2.4 |
2.5 |
43.9 |
47.2 |
3237 |
6214 |
4334 |
7372 |
|
4×150 |
36 |
1.8 |
1.4 |
0.5 |
48/2.5 |
2.5 |
2.6 |
48.3 |
52 |
3853 |
7622 |
5148 |
8917 |
|
4×185 |
36 |
2 |
1.6 |
0.5 |
54/2.5 |
2.7 |
2.8 |
54.3 |
57.6 |
4756 |
9323 |
6132 |
10774 |
|
4×240 |
60 |
2.2 |
1.6 |
0.5 |
59/2.5 |
2.9 |
3 |
59.2 |
62.9 |
5774 |
11906 |
7374 |
13506 |
|
4×300 |
60 |
2.4 |
1.6 |
0.5 |
65/2.5 |
3 |
3.2 |
64.3 |
68.1 |
6922 |
14589 |
8624 |
16291 |
5)600/1000V, Multi Cores, Circular Compacted Al or Cu/PVC/PVC Armoured Power Cable
Cross Section of Conductor |
No. of Wires |
Thickness of Insulation |
Thickness of Inner Sheath |
Thickness of Steel Tape |
No./Dia. Of Steel Wires |
Thickness of Sheath |
Overall Diameter |
Approx. Net Weight |
|||||
STA |
SWA |
||||||||||||
STA |
SWA |
STA |
SWA |
STA |
SWA |
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
||||
mm2 |
– |
mm |
mm |
mm |
No./mm |
mm |
mm |
mm |
mm |
kg/km |
kg/km |
kg/km |
kg/km |
Three Cores |
|||||||||||||
3×10 |
7 |
1 |
1 |
0.2 |
35/1.25 |
1.8 |
1.8 |
19.4 |
21.5 |
494 |
679 |
988 |
1172 |
3×16 |
7 |
1 |
1 |
0.2 |
32/1.6 |
1.8 |
1.8 |
21.5 |
24.3 |
604 |
895 |
1051 |
1343 |
3×25 |
7 |
1.2 |
1 |
0.2 |
38/1.6 |
1.8 |
1.8 |
25 |
27.9 |
791 |
1252 |
1329 |
1790 |
3×35 |
7 |
1.2 |
1 |
0.2 |
42/1.6 |
1.8 |
1.9 |
27.2 |
30.2 |
950 |
1595 |
1551 |
2196 |
3×50 |
19 |
1.4 |
1.1 |
0.2 |
39/2.0 |
2 |
2.1 |
31.3 |
35.2 |
1213 |
2079 |
2128 |
2994 |
3×70 |
19 |
1.4 |
1.2 |
0.5 |
45/2.0 |
2.1 |
2.2 |
35.6 |
40.1 |
1567 |
2894 |
2678 |
4005 |
3×95 |
19 |
1.6 |
1.3 |
0.5 |
42/2.5 |
2.3 |
2.4 |
42 |
46.2 |
2449 |
4188 |
3689 |
5428 |
3×120 |
37 |
1.6 |
1.3 |
0.5 |
45/2.5 |
2.4 |
2.5 |
45.3 |
49.6 |
2823 |
5014 |
4174 |
6364 |
3×150 |
37 |
1.8 |
1.4 |
0.5 |
49/2.5 |
2.5 |
2.7 |
48.9 |
53.2 |
3327 |
6069 |
4795 |
7537 |
3×185 |
37 |
2 |
1.5 |
0.5 |
56/2.5 |
2.7 |
2.8 |
54.5 |
58.7 |
4038 |
7371 |
5686 |
9019 |
3×240 |
61 |
2.2 |
1.6 |
0.5 |
63/2.5 |
2.9 |
3.1 |
61.4 |
65.2 |
4994 |
9457 |
6862 |
11325 |
3×300 |
61 |
2.4 |
1.7 |
0.5 |
70/2.5 |
3.2 |
3.3 |
67.9 |
71.7 |
6022 |
11564 |
8101 |
13643 |
3×400 |
61 |
2.6 |
1.9 |
0.5 |
62/3.15 |
3.4 |
3.6 |
75.4 |
80.5 |
7350 |
14543 |
10535 |
17728 |
Four Cores |
|||||||||||||
4×10 |
7 |
1 |
1 |
0.2 |
39/1.25 |
1.8 |
1.8 |
20.9 |
23 |
552 |
798 |
1073 |
1319 |
4×16 |
7 |
1 |
1 |
0.2 |
35/1.6 |
1.8 |
1.8 |
23.3 |
26.1 |
723 |
1110 |
1213 |
1601 |
4×25 |
7 |
1.2 |
1 |
0.2 |
42/1.6 |
1.8 |
1.9 |
27.2 |
30.2 |
959 |
1573 |
1559 |
2173 |
4×35 |
7 |
1.2 |
1 |
0.2 |
37/2.0 |
1.9 |
2 |
29.7 |
33.6 |
1140 |
2000 |
2006 |
2866 |
4×50 |
19 |
1.4 |
1.2 |
0.2 |
44/2.0 |
2.1 |
2.2 |
34.6 |
38.4 |
1524 |
2679 |
2541 |
3696 |
4×70 |
19 |
1.4 |
1.2 |
0.5 |
50/2.0 |
2.3 |
2.3 |
40.5 |
43.7 |
2338 |
4107 |
3187 |
4956 |
4×95 |
19 |
1.6 |
1.2 |
0.5 |
46/2.5 |
2.4 |
2.6 |
45.9 |
50.2 |
2955 |
5274 |
4325 |
6644 |
4×120 |
37 |
1.6 |
1.4 |
0.5 |
51/2.5 |
2.6 |
2.7 |
50 |
54.2 |
3466 |
6387 |
4568 |
7888 |
4×150 |
37 |
1.8 |
1.4 |
0.5 |
55/2.5 |
2.7 |
2.8 |
53.8 |
58.1 |
4144 |
7800 |
5772 |
9428 |
4×185 |
37 |
2 |
1.6 |
0.5 |
62/2.5 |
2.9 |
3 |
60.2 |
64.5 |
4987 |
9430 |
6822 |
11266 |
4×240 |
61 |
2.2 |
1.6 |
0.5 |
70/2.5 |
3.1 |
3.3 |
67.7 |
71.5 |
6161 |
12111 |
8233 |
14184 |
4×300 |
61 |
2.4 |
1.6 |
0.5 |
61/3.15 |
3.4 |
3.5 |
74.7 |
78.8 |
7346 |
14735 |
10305 |
17694 |
We are China High Performance 600/1000V PVC Insulated Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Cable Products
High Quality Multicore Control Cable
2023 Hot Selling XLPE Insulation PVC Sheathed Power Cable
XLPE Insulated Power Cable Best Quality Smart Power off Cable
0.6/1 Kv 2*16sqmm Overhead Aluminum Conductor XLPE/PE Insulation Twisted Overhead ABC Cable
Wire Cable Electric Cable Electric Wire Aluminium Conductor ABC Cable for Overhead Drop Service Used
4 Core 150mm2 Copper Conductor XLPE Power Cable
Popular High Performance 600/1000V PVC Insulated Power Cable Products
Popular jpcable99 Products
Al/Cu Core Conductor Armored Power Cable
Bare Conductor/ Aluminum Conductor Aluminum Alloy Reinforced
300mm2 Al Conductor Armored Power Cable
IEC60502 Standard 1kv Aerial Bundled ABC Cable
Swan 4AWG ACSR Bare Conductor Aluminum Conductor
2*6AWG Aluminium Concentric Cable
Popular Power Cable Products
35kv Composite Conductor XLPE Insulation Power Cable
XLPE Insulated Steel Tape Armoured Copper Power Overhead Electrical/Electric Wire Cable
Low Voltage AC Cable Single Core Cable Cu/PVC/PVC
Thwn Thhn in AWG Standard Copper Cable PVC Insulated Electrical Building Wire
Copper Core PVC Insulated/Sheathed Fire-Resistant Electrical Electric Wire Cable
XLPE or PE Copper PVC Jacket Control Cable
Tags: Cable, High Performance 600/1000V PVC Insulated Power Cable, jpcable99, Power Cable