High Quality 4X10mm2 Copper Core PVC Power Cable
High Quality 4X10mm2 Copper Core PVC Power Cable image
Get Latest Price Request a quote
Basic Info.
Product Description
Application:
With the characteristics of stable capability,advanced technology,broad material resources,low price, good flexible and easy to lay and maintain, the PVC Insulated and Sheathed Power Cable are suitable to be laid for distribution line with A.C.50HZ and rated voltage up to 6kV.
Property:
1.The long-time permissible working temperature of cable conductive core is not more than 70 °C.
2.During short circuit (max. permanent time is not more than 5 seconds), the max temperature of cable conductor is not more than 165°C.
3.The difference level of laying cable is not restricted.When laying the cable,ambient temperature is not lower than 0°C.
4.They have good chemical stability,and properties of acid resistance,alkali resistance,salt resistance,oil resistance,solvent resistance and flame resistance.rty
5.Light weight,good bending property and easy installation and maintenance.
Specification:
Standard:
IEC,BS,VDE,AS/NZS,ICEA,JIS and so on,designing and manufacturing special power cable according to the other standards required by the customer
1)600/1000V, Single Core, Circular Compacted Al or Cu/PVC/PVC Unarmoured or Armoured Power Cable
Cross Section of Conductor | No. of Wires | Thickness of Insulation | Unarmoured | Armoured | ||||||||
Thickness of Sheath | Overall Dia. | jpcable99.en. Weight | Thickness of Bedding | Thickness of Al Tape | Thickness of Sheath | Overall Dia. | jpcable99.en. Weight | |||||
Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | |||||||||
mm2 | – | mm | mm | mm | kg/km | kg/km | mm | mm | mm | mm | kg/km | kg/km |
1.5 | 1 | 0.8 | 1.4 | 5.8 | – | 51 | – | – | – | – | – | – |
2.5 | 1 | 0.8 | 1.4 | 6.2 | – | 64 | – | – | – | – | – | – |
4 | 1 | 1 | 1.4 | 7.1 | – | 88 | – | – | – | – | – | – |
6 | 7 | 1 | 1.4 | 7.8 | 78 | 114 | – | – | – | – | – | – |
10 | 7 | 1 | 1.4 | 8.6 | 96 | 159 | 1 | 0.5 | 1.8 | 13.4 | 234 | 295 |
16 | 7 | 1 | 1.4 | 9.6 | 123 | 222 | 1 | 0.5 | 1.8 | 14.4 | 274 | 370 |
25 | 7 | 1.2 | 1.4 | 11.2 | 172 | 328 | 1 | 0.5 | 1.8 | 16 | 344 | 496 |
35 | 7 | 1.2 | 1.4 | 12.2 | 209 | 428 | 1 | 0.5 | 1.8 | 17 | 393 | 606 |
50 | 19 | 1.4 | 1.4 | 13.9 | 271 | 565 | 1 | 0.5 | 1.8 | 18.7 | 478 | 764 |
70 | 19 | 1.4 | 1.5 | 15.9 | 356 | 818 | 1 | 0.5 | 1.8 | 20.5 | 582 | 1020 |
95 | 19 | 1.6 | 1.5 | 18 | 471 | 1041 | 1 | 0.5 | 1.8 | 22.6 | 717 | 1291 |
120 | 37 | 1.6 | 1.6 | 19.6 | 563 | 1307 | 1 | 0.5 | 1.8 | 24 | 822 | 1545 |
150 | 37 | 1.8 | 1.6 | 21.3 | 684 | 1592 | 1 | 0.5 | 1.8 | 25.4 | 952 | 1857 |
185 | 37 | 2 | 1.7 | 23.9 | 840 | 1985 | 1 | 0.5 | 1.8 | 27.9 | 1136 | 2236 |
240 | 61 | 2.2 | 1.8 | 27 | 1071 | 2533 | 1 | 0.5 | 1.9 | 31 | 1404 | 2877 |
300 | 61 | 2.4 | 1.9 | 29.6 | 1317 | 3162 | 1.2 | 0.5 | 2.1 | 34.3 | 1722 | 3551 |
400 | 61 | 2.6 | 2 | 33.2 | 1666 | 4120 | 1.2 | 0.5 | 2.2 | 37.6 | 2114 | 4488 |
500 | 61 | 2.8 | 2.2 | 37.5 | 2089 | 5163 | 1.2 | 0.5 | 2.3 | 42.1 | 2592 | 5683 |
630 | 61 | 2.8 | 2.3 | 41.2 | 2581 | 6447 | 1.4 | 0.5 | 2.4 | 46.3 | 3184 | 7060 |
2)600/1000V, Multi Cores, Sectoral Compacted Al or Cu/PVC/PVC Unarmoured Power Cable
Number of Cores | Cross-Section of Conductor | No. Of Wires | Thickness of Insulation | Thickness of Sheath | Overall Diameter | Approx. Net Weight | |
Al Conductor | Cu Conductor | ||||||
– | mm2 | – | mm | mm | mm | kg/km | kg/km |
Three Cores | 3×35 | 16 | 1.2 | 1.8 | 21.9 | 601 | 1280 |
3×50 | 18 | 1.4 | 1.8 | 26.5 | 829 | 1732 | |
3×70 | 18 | 1.4 | 1.9 | 29.2 | 1067 | 2367 | |
3×95 | 36 | 1.6 | 2 | 32.9 | 1409 | 2317 | |
3×120 | 36 | 1.6 | 2.1 | 36.2 | 1705 | 3983 | |
3×150 | 36 | 1.8 | 2.2 | 38.8 | 2045 | 4872 | |
3×185 | 36 | 2 | 2.4 | 44.8 | 2596 | 6077 | |
3×240 | 60 | 2.2 | 2.6 | 51.5 | 3353 | 7953 | |
3×300 | 60 | 2.4 | 2.7 | 54.9 | 6069 | 9820 | |
Four Cores with Reduced Neutral | 3×35+16 | 16-7 | 1.2-1 | 1.8 | 25.5 | 764 | 1107 |
3×50+25 | 18-16 | 1.4-1.2 | 1.9 | 28.7 | 982 | 1410 | |
3×70+35 | 18-16 | 1.4-1.2 | 2.0 | 32 | 1278 | 1733 | |
3×95+50 | 36-18 | 1.6-1.4 | 2.2 | 37.8 | 1711 | 2656 | |
3×120+70 | 36-18 | 1.6-1.4 | 2.3 | 40.5 | 2065 | 3137 | |
3×150+70 | 36-18 | 1.8-1.4 | 2.4 | 44.8 | 2480 | 3660 | |
3×185+95 | 36-36 | 2-1.6 | 2.6 | 49.7 | 3086 | 4345 | |
3×240+120 | 60-36 | 2.2-1.6 | 2.8 | 56 | 3894 | 5441 | |
3×300+150 | 60-36 | 1.4-1.8 | 2.9 | 60.3 | 4834 | 6494 | |
Four Cores | 4×25 | 16 | 1.2 | 1.8 | 22.5 | 644 | 1286 |
4×35 | 16 | 1.2 | 1.8 | 24.6 | 799 | 1696 | |
4×50 | 18 | 1.4 | 1.8 | 28.6 | 1071 | 2275 | |
4×70 | 18 | 1.4 | 2 | 31.6 | 1387 | 3120 | |
4×95 | 36 | 1.6 | 2.1 | 35.9 | 1850 | 4262 | |
4×120 | 36 | 1.6 | 2.2 | 38.8 | 2209 | 5247 | |
4×150 | 36 | 1.8 | 2.3 | 43.1 | 2714 | 6483 | |
4×185 | 36 | 2 | 2.5 | 48.7 | 3403 | 8045 | |
4×240 | 60 | 2.2 | 2.7 | 53.6 | 4290 | 10422 | |
4×300 | 60 | 2.4 | 2.9 | 58.8 | 5302 | 12969 |
3)600/1000V, Multi Cores, Circular Compacted Al or Cu/PVC/PVC Unarmoured Power Cable
Number of Cores | Cross-Section of Conductor | No. Of Wires | Thickness of Insulation | Thickness of Sheath | Overall Diameter | Approx. Net Weight | ||
Al Conductor | Cu Conductor | |||||||
– | mm2 | – | mm | mm | mm | kg/km | kg/km | |
Three Cores | 3×10 | 7 | 1 | 1.8 | 16.6 | 281 | 465 | |
3×16 | 7 | 1 | 1.8 | 18.7 | 387 | 679 | ||
3×25 | 7 | 1.2 | 1.8 | 22.2 | 536 | 996 | ||
3×35 | 7 | 1.2 | 1.8 | 24.4 | 665 | 1311 | ||
3×50 | 19 | 1.4 | 1.9 | 28.1 | 863 | 1729 | ||
3×70 | 19 | 1.4 | 2 | 32.3 | 1153 | 2480 | ||
3×95 | 19 | 1.6 | 2.1 | 37.1 | 1563 | 3301 | ||
3×120 | 37 | 1.6 | 2.3 | 40.4 | 1850 | 4040 | ||
3×150 | 37 | 1.8 | 2.4 | 43.9 | 2258 | 5000 | ||
3×185 | 37 | 2 | 2.5 | 49.2 | 2819 | 6151 | ||
3×240 | 61 | 2.2 | 2.8 | 55.9 | 3577 | 8040 | ||
3×300 | 61 | 2.4 | 3 | 62.1 | 4413 | 9955 | ||
3×400 | 61 | 2.6 | 3.2 | 69.3 | 5512 | 12705 | ||
Four Cores | 4×10 | 7 | 1 | 1.8 | 18.1 | 343 | 589 | |
4×16 | 7 | 1 | 1.8 | 20.5 | 487 | 874 | ||
4×25 | 7 | 1.2 | 1.8 | 24.3 | 677 | 1291 | ||
4×35 | 7 | 1.2 | 1.8 | 26.8 | 821 | 1681 | ||
4×50 | 19 | 1.4 | 2 | 31.2 | 1118 | 2273 | ||
4×70 | 19 | 1.4 | 2.1 | 35.8 | 1494 | 3264 | ||
4×95 | 19 | 1.6 | 2.3 | 41.2 | 1993 | 4312 | ||
4×120 | 37 | 1.6 | 2.4 | 44.8 | 2370 | 5291 | ||
4×150 | 37 | 1.8 | 2.5 | 48.7 | 2959 | 6615 | ||
4×185 | 37 | 2 | 2.7 | 54.7 | 3601 | 8044 | ||
4×240 | 61 | 2.2 | 3 | 62.1 | 4596 | 10547 | ||
4×300 | 61 | 2.4 | 3.2 | 69.1 | 5614 | 13004 |
4)600/1000V, Multi Cores, Sectoral Compacted Al or Cu/PVC/PVC Armoured Power Cable
Cross Section of Conductor | No. of Wires | Thickness of Insulation | Thickness of Inner Sheath | Thickness of Steel Tape | No./Dia. Of Steel Wires | Thickness of Sheath | Overall Diameter | Approx. Net Weight | ||||||
STA | SWA | |||||||||||||
STA | SWA | STA | SWA | STA | SWA | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | |||||
mm2 | – | mm | mm | mm | No./mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km | |
Three Cores | ||||||||||||||
3×35 | 16 | 1.2 | 1 | 0.2 | 38/1.6 | 1.8 | 1.9 | 24.7 | 28.2 | 912 | 1591 | 1447 | 2126 | |
3×50 | 18 | 1.4 | 1 | 0.2 | 46/1.6 | 1.9 | 2 | 29.3 | 32.8 | 1202 | 2105 | 1842 | 2745 | |
3×70 | 18 | 1.4 | 1.2 | 0.2 | 41/2.0 | 2.0 | 2.2 | 32.5 | 37.1 | 1520 | 2820 | 2475 | 3775 | |
3×95 | 36 | 1.6 | 1.2 | 0.5 | 46/2.0 | 2.1 | 2.3 | 36.5 | 40.8 | 2241 | 4049 | 2989 | 4797 | |
3×120 | 36 | 1.6 | 1.2 | 0.5 | 50/2.0 | 2.2 | 2.4 | 39.8 | 44.1 | 2617 | 4895 | 3435 | 5713 | |
3×150 | 36 | 1.8 | 1.2 | 0.5 | 43/2.5 | 2.3 | 2.5 | 42.4 | 47.8 | 3019 | 5846 | 4258 | 7085 | |
3×185 | 36 | 2 | 1.4 | 0.5 | 50/2.5 | 2.5 | 2.7 | 48.8 | 54.2 | 3783 | 7264 | 5219 | 8700 | |
3×240 | 60 | 2.2 | 1.6 | 0.5 | 58/2.5 | 2.8 | 2.9 | 56 | 61.3 | 4790 | 9390 | 6444 | 11044 | |
3×300 | 60 | 2.4 | 1.6 | 0.5 | 61/2.5 | 2.9 | 3.1 | 59.3 | 64.7 | 5594 | 11345 | 7458 | 13209 | |
Four Cores with Reduced Neutral | ||||||||||||||
3×35+16 | 16-7 | 1.2-1 | 1 | 0.2 | 43/1.6 | 1.9 | 2 | 28.5 | 31.3 | 1107 | 1528 | 1705 | 2469 | |
3×50+25 | 18-16 | 1.4-1.2 | 1.2 | 0.2 | 40/2.0 | 2.0 | 2.1 | 32.2 | 36.1 | 1410 | 2044 | 2326 | 3388 | |
3×70+35 | 18-16 | 1.4-1.2 | 1.2 | 0.2 | 44/2.0 | 2.0 | 2.2 | 35.2 | 39.3 | 1733 | 2801 | 2762 | 4285 | |
3×95+50 | 36-18 | 1.6-1.4 | 1.2 | 0.5 | 41/2.5 | 2.3 | 2.5 | 42.5 | 46.3 | 2656 | 3820 | 3816 | 5925 | |
3×120+70 | 36-18 | 1.6-1.4 | 1.4 | 0.5 | 45/2.5 | 2.4 | 2.6 | 45.6 | 49.4 | 3137 | 4777 | 4391 | 7103 | |
3×150+70 | 36-18 | 1.8-1.4 | 1.4 | 0.5 | 49/2.5 | 2.6 | 2.7 | 49.9 | 53.6 | 3660 | 5709 | 5043 | 8272 | |
3×185+95 | 36-36 | 2-1.6 | 1.4 | 0.5 | 55/2.5 | 2.6 | 2.9 | 54.5 | 58.5 | 3445 | 7171 | 5902 | 9987 | |
3×240+120 | 60-36 | 2.2-1.6 | 1.6 | 0.5 | 62/2.5 | 2.9 | 3.1 | 61.6 | 65.3 | 5441 | 9272 | 7174 | 12552 | |
3×300+150 | 60-36 | 1.4-1.8 | 1.6 | 0.5 | 67/2.5 | 3.8 | 3.2 | 65.9 | 69.6 | 6494 | 11546 | 8355 | 15067 | |
Four Cores | ||||||||||||||
4×25 | 16 | 1.2 | 1 | 0.2 | 38/1.6 | 1.8 | 1.9 | 25.3 | 28 | 934 | 1576 | 1450 | 2092 | |
4×35 | 16 | 1.2 | 1 | 0.2 | 41/1.6 | 1.8 | 1.9 | 27.4 | 30.2 | 1120 | 2017 | 1681 | 2578 | |
4×50 | 18 | 1.4 | 1 | 0.2 | 39/2.0 | 2 | 2.1 | 31.6 | 35.6 | 1454 | 2658 | 2336 | 3540 | |
4×70 | 18 | 1.4 | 1.2 | 0.5 | 43/2.0 | 2.1 | 2.2 | 36.3 | 39 | 2183 | 3916 | 2840 | 4573 | |
4×95 | 36 | 1.6 | 1.2 | 0.5 | 50/2.0 | 2.3 | 2.4 | 40.6 | 44.1 | 2748 | 5160 | 3545 | 5957 | |
4×120 | 36 | 1.6 | 1.4 | 0.5 | 42/2.5 | 2.4 | 2.5 | 43.9 | 47.2 | 3237 | 6214 | 4334 | 7372 | |
4×150 | 36 | 1.8 | 1.4 | 0.5 | 48/2.5 | 2.5 | 2.6 | 48.3 | 52 | 3853 | 7622 | 5148 | 8917 | |
4×185 | 36 | 2 | 1.6 | 0.5 | 54/2.5 | 2.7 | 2.8 | 54.3 | 57.6 | 4756 | 9323 | 6132 | 10774 | |
4×240 | 60 | 2.2 | 1.6 | 0.5 | 59/2.5 | 2.9 | 3 | 59.2 | 62.9 | 5774 | 11906 | 7374 | 13506 | |
4×300 | 60 | 2.4 | 1.6 | 0.5 | 65/2.5 | 3 | 3.2 | 64.3 | 68.1 | 6922 | 14589 | 8624 | 16291 |
5)600/1000V, Multi Cores, Circular Compacted Al or Cu/PVC/PVC Armoured Power Cable
Cross Section of Conductor | No. of Wires | Thickness of Insulation | Thickness of Inner Sheath | Thickness of Steel Tape | No./Dia. Of Steel Wires | Thickness of Sheath | Overall Diameter | Approx. Net Weight | |||||
STA | SWA | ||||||||||||
STA | SWA | STA | SWA | STA | SWA | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||
mm2 | – | mm | mm | mm | No./mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km |
Three Cores | |||||||||||||
3×10 | 7 | 1 | 1 | 0.2 | 35/1.25 | 1.8 | 1.8 | 19.4 | 21.5 | 494 | 679 | 988 | 1172 |
3×16 | 7 | 1 | 1 | 0.2 | 32/1.6 | 1.8 | 1.8 | 21.5 | 24.3 | 604 | 895 | 1051 | 1343 |
3×25 | 7 | 1.2 | 1 | 0.2 | 38/1.6 | 1.8 | 1.8 | 25 | 27.9 | 791 | 1252 | 1329 | 1790 |
3×35 | 7 | 1.2 | 1 | 0.2 | 42/1.6 | 1.8 | 1.9 | 27.2 | 30.2 | 950 | 1595 | 1551 | 2196 |
3×50 | 19 | 1.4 | 1.1 | 0.2 | 39/2.0 | 2 | 2.1 | 31.3 | 35.2 | 1213 | 2079 | 2128 | 2994 |
3×70 | 19 | 1.4 | 1.2 | 0.5 | 45/2.0 | 2.1 | 2.2 | 35.6 | 40.1 | 1567 | 2894 | 2678 | 4005 |
3×95 | 19 | 1.6 | 1.3 | 0.5 | 42/2.5 | 2.3 | 2.4 | 42 | 46.2 | 2449 | 4188 | 3689 | 5428 |
3×120 | 37 | 1.6 | 1.3 | 0.5 | 45/2.5 | 2.4 | 2.5 | 45.3 | 49.6 | 2823 | 5014 | 4174 | 6364 |
3×150 | 37 | 1.8 | 1.4 | 0.5 | 49/2.5 | 2.5 | 2.7 | 48.9 | 53.2 | 3327 | 6069 | 4795 | 7537 |
3×185 | 37 | 2 | 1.5 | 0.5 | 56/2.5 | 2.7 | 2.8 | 54.5 | 58.7 | 4038 | 7371 | 5686 | 9019 |
3×240 | 61 | 2.2 | 1.6 | 0.5 | 63/2.5 | 2.9 | 3.1 | 61.4 | 65.2 | 4994 | 9457 | 6862 | 11325 |
3×300 | 61 | 2.4 | 1.7 | 0.5 | 70/2.5 | 3.2 | 3.3 | 67.9 | 71.7 | 6022 | 11564 | 8101 | 13643 |
3×400 | 61 | 2.6 | 1.9 | 0.5 | 62/3.15 | 3.4 | 3.6 | 75.4 | 80.5 | 7350 | 14543 | 10535 | 17728 |
Four Cores | |||||||||||||
4×10 | 7 | 1 | 1 | 0.2 | 39/1.25 | 1.8 | 1.8 | 20.9 | 23 | 552 | 798 | 1073 | 1319 |
4×16 | 7 | 1 | 1 | 0.2 | 35/1.6 | 1.8 | 1.8 | 23.3 | 26.1 | 723 | 1110 | 1213 | 1601 |
4×25 | 7 | 1.2 | 1 | 0.2 | 42/1.6 | 1.8 | 1.9 | 27.2 | 30.2 | 959 | 1573 | 1559 | 2173 |
4×35 | 7 | 1.2 | 1 | 0.2 | 37/2.0 | 1.9 | 2 | 29.7 | 33.6 | 1140 | 2000 | 2006 | 2866 |
4×50 | 19 | 1.4 | 1.2 | 0.2 | 44/2.0 | 2.1 | 2.2 | 34.6 | 38.4 | 1524 | 2679 | 2541 | 3696 |
4×70 | 19 | 1.4 | 1.2 | 0.5 | 50/2.0 | 2.3 | 2.3 | 40.5 | 43.7 | 2338 | 4107 | 3187 | 4956 |
4×95 | 19 | 1.6 | 1.2 | 0.5 | 46/2.5 | 2.4 | 2.6 | 45.9 | 50.2 | 2955 | 5274 | 4325 | 6644 |
4×120 | 37 | 1.6 | 1.4 | 0.5 | 51/2.5 | 2.6 | 2.7 | 50 | 54.2 | 3466 | 6387 | 4568 | 7888 |
4×150 | 37 | 1.8 | 1.4 | 0.5 | 55/2.5 | 2.7 | 2.8 | 53.8 | 58.1 | 4144 | 7800 | 5772 | 9428 |
4×185 | 37 | 2 | 1.6 | 0.5 | 62/2.5 | 2.9 | 3 | 60.2 | 64.5 | 4987 | 9430 | 6822 | 11266 |
4×240 | 61 | 2.2 | 1.6 | 0.5 | 70/2.5 | 3.1 | 3.3 | 67.7 | 71.5 | 6161 | 12111 | 8233 | 14184 |
4×300 | 61 | 2.4 | 1.6 | 0.5 | 61/3.15 | 3.4 | 3.5 | 74.7 | 78.8 | 7346 | 14735 | 10305 | 17694 |
We are China High Quality 4X10mm2 Copper Core PVC Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Cable Products
Flexible Wire 3X2.5 4X4 4X6sqmm PVC Electric Cable
0.6/1kv N2xry Low Voltage XLPE Insulated Armoured Cables
0.6/1kv XLPE Insulated Power Cable
0.6/1kv 3X120+2X70 Cable with High Quality
Low Voltage Control Cable with PVC Insulated
Water/Oil Resistance Submersible Pump Cable 13mm2 Submersible Oil Pump Cable
Popular High Quality 4X10mm2 Copper Core PVC Power Cable Products
Popular jpcable99 Products
Factory Price 300mm2 Bare Aluminum Conductor
BS 215 Hare (Aluminium Conductor Steel Reinforced ACSR Conductor
AAC Ant/Bee/Locust All Aluminium Conductor
ASTM B231 Standard AAC Conductor
Copper Conductor Cable 150mm PVC Power Cable
Good Price Hot Sale All Aluminium Alloy Conductor
Popular Power Cable Products
Medium Voltage Power Cable, Mv90, Mv105 LLDPE, MDPE, PVC Aluminum XLPE Cable
Aluminum Cable 75mm ACSR Conductor Price Dog Rabbit Overhead Cable
U-1000 Rgpfv 3X185mm2 Insulated and Sheathed Flame Retardant, XLPE/Gswa LSZH PVC
Copper Conductor Electric Power Cable with Low Voltage
0.6/1kv XLPE Insulated Power Cable for Building Wire
Tags: Cable, High Quality 4X10mm2 Copper Core PVC Power Cable, jpcable99, Power Cable