High Quality ASTM B399 Standard AAAC Conductor
High Quality ASTM B399 Standard AAAC Conductor image
Get Latest Price Request a quote
Basic Info.
Product Description
Application
Used as bare overhead conductor for primary and secondary distribution. Designed utilizing a high-strength aluminum alloy to achieve a high strength-to-weight ratio; affords better sag characteristics. Aluminum alloy gives AAAC higher resistance to corrosion than ACSR.
Construction
Standard 6201-T81 high strength aluminum conductors, conforming to ASTM Specification B-399, are concentric-lay-stranded, similar in construction and appearance to 1350 grade aluminum conductors. Standard 6210 alloy conductors are similar to other alloy conductors commercially known as Ardival, Aldrey or Almelec. They were developed to fill the need for an economical conductor for overhead applications requiring higher strength than that obtainable with 1350 grade aluminum conductors, but without a steel core. The DC resistance at 20 °C of the 6201-T81 conductors and of the standard ACSR of the same diameter are approximately the same. Conductors of the 6201-T81 alloys are harder and , therefore, have a greater resistance to abrasion than conductors of 1350-H19 grade aluminum.
Specification
AAAC bare conductor meets or exceeds the following ASTM specifications:
B-398 Aluminum Alloy 6201-T81 Wire for Electrical Purposes
B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors
FAQ
1. How many years has Henan Jiapu Cable Group been in production?
Founded in October 1998 by Mr. Gu, our facility has three separate manufacturing workshops within its 100,000-sq.-ft. building. In 2012, we operates in a new 666,000 sq. foot state-of-the-art facility in Xiaodian Industry Park.,Xinxiang, Henan ,China
2. What kinds of products does Jiapu Cable manufacture?
1)Bare Conductor ,such as AAC,AAAC,ACSR,ACAR,AACSR,ACSR/AW and so on;
2)Aerial Bundled Cable (1kV-35kV ),such as Duplex,Triplex,Quadruplex Drop Wires and so on;
3)PVC Insulated (Flexible ) Wire ;
4) PVC Insulated and Sheathed (Armoured) Power Cable;
5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;
6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on;
3. What kind of certifications do you have?
SABS, CE, ISO9001-2000, SGS
4.Which markets do you involve mainly in?
Our products have been exported mainly to Africa, Middle East, South-east Asia, South America,Central America,North America, Europe ,Australia, etc.
5. Which standards do you comply with when you produce the electrical wires and cables ?
We are able to produce electrical wires and cables based on GB, JB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA, etc. Meanwhile, we can design and manufacture the cables according to the samples and technical specification the customer supply.
6. What is the min.order quantity ?
It depends on the type and size of electrical wires and cables. For some small electrical wires, 100 meters can be accepted .But for the power cables with medium or high voltage, that should comply with the property of installed equipments. Anyhow,we will try our best to solve the problem and meet with the requirement If you have special request.
7. What is the production capacity per week or per month ?
For the bare conductor, we can finish 3000 tons within one month. For power cables, that depends on the type and size. The total output value per month is approx. USD3,000,000.00 for insulated aluminum cables and that is approx. USD8,000,000.00 for insulated copper cables.
8. Do you supply the customers with installation service in foreign country ?
We don’t have professional installation teams in foreign country.But if that is necessary, we will recommend our partners to cooperate with you.
Specifications:
| Code Name |
Area | Size & Stranding of ACSR with Equal Diameter | No. & Diameter of wires | Overall Diameter | Weight | Nominal Breaking Load | Area | Stranding and Wire Diameter | Approx Overall Diameter | Weight | Nominal Breaking Load | Max.D.C. Resistance | |||
| Nominal | Actual | Nominal | Actual | ||||||||||||
| MCM | mm 2 | AWG or MCM | Al/Steel | mm | mm | kg/km | kN | AWG or MCM | mm² | mm | mm | kg/km | kN | Ω/km | |
| Akron | 30.58 | 15.48 | 6 | 6/1 | 7/1.68 | 5.04 | 42.7 | 4.92 | 6 | 13.3 | 7/1.554 | 4.67 | 37 | 4.22 | 2.5199 |
| Alton | 48.69 | 24.71 | 4 | 6/1 | 7/2.12 | 6.35 | 68.0 | 7.84 | 4 | 21.15 | 7/1.961 | 5.89 | 58 | 6.71 | 1.5824 |
| Ames | 77.47 | 39.22 | 2 | 6/1 | 7/2.67 | 8.02 | 108 | 12.45 | 2 | 33.63 | 7/2.474 | 7.42 | 93 | 10.68 | 0.9942 |
| Azusa | 123.3 | 62.38 | 1/0 | 6/1 | 7/3.37 | 10.11 | 172 | 18.97 | 1/0 | 53.48 | 7/3.119 | 9.36 | 148 | 16.97 | 0.6256 |
| Anaheim | 155.4 | 78.65 | 2/0 | 6/1 | 7/3.78 | 11.35 | 217 | 23.93 | 2/0 | 67.42 | 7/3.503 | 10.51 | 186 | 20.52 | 0.4959 |
| Amherst | 195.7 | 99.22 | 3/0 | 6/1 | 7/4.25 | 12.75 | 273 | 30.18 | 3/0 | 85.03 | 7/3.932 | 11.8 | 234 | 25.86 | 0.3936 |
| Alliance | 246.9 | 125.1 | 4/0 | 6/1 | 7/4.77 | 14.31 | 345 | 38.05 | 4/0 | 107.23 | 7/4.417 | 13.26 | 296 | 32.63 | 0.3119 |
| Butte | 312.8 | 158.6 | 266.8 | 26/7 | 19/3.26 | 16.30 | 437 | 48.76 | 250 | 126.66 | 19/2.913 | 14.57 | 349 | 38.93 | 0.2642 |
| Canton | 394.5 | 199.9 | 336.4 | 26/7 | 19/3.66 | 18.30 | 551 | 58.91 | 300 | 152.1 | 19/3.193 | 15.97 | 419 | 46.77 | 0.2199 |
| Cairo | 465.4 | 235.8 | 397.5 | 26/7 | 19/3.98 | 19.88 | 650 | 69.48 | 350 | 177.35 | 19/3.447 | 17.24 | 489 | 52.25 | 0.1887 |
| Darien | 559.5 | 283.5 | 477.0 | 26/7 | 19/4.36 | 21.79 | 781 | 83.52 | 400 | 202.71 | 19/3.686 | 18.43 | 559 | 59.74 | 0.165 |
| Elgin | 652.4 | 330.6 | 556.5 | 26/7 | 19/4.71 | 23.54 | 911 | 97.42 | 450 | 228 | 19/3.909 | 19.55 | 629 | 67.19 | 0.1467 |
| Flint | 740.8 | 375.3 | 636.0 | 26/7 | 37/3.59 | 25.16 | 1035 | 108.21 | 500 | 253.35 | 19/4.120 | 20.6 | 698 | 74.64 | 0.1321 |
| Greely | 927.2 | 469.8 | 795.0 | 26/7 | 37/4.02 | 28.14 | 1295 | 135.47 | 550 | 278.6 | 37/3.096 | 21.67 | 768 | 83.8 | 0.1202 |
| 600 | 303.8 | 37/3.233 | 22.63 | 838 | 91.38 | 0.1102 | |||||||||
| 650 | 329.25 | 37/3.366 | 23.56 | 908 | 97.94 | 0.1016 | |||||||||
| 700 | 354.55 | 37/3.493 | 24.45 | 978 | 102.2 | 0.0944 | |||||||||
| 750 | 380.2 | 37/3.617 | 25.32 | 1049 | 109.6 | 0.088 | |||||||||
| 800 | 405.15 | 37/3.734 | 26.14 | 1117 | 116.8 | 0.0826 | |||||||||
| 900 | 456.16 | 37/3.962 | 27.73 | 1258 | 131.5 | 0.0733 | |||||||||
| 1000 | 506.71 | 37/4.176 | 29.23 | 1399 | 146.1 | 0.066 | |||||||||
We are China High Quality ASTM B399 Standard AAAC Conductor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular AAAC Products
ASTM B399 6201 Overhead Electrical Cable Bare Aluminium Alloy AAC AAAC ACSR Conductor with Grease
AAAC Greeley Overhead Bare Aluminium Conductor
Bare AAAC Conductor with ASTM BS IEC
Australia Standard Metric Conductors AAAC AAC ACSR Aacsr Bare Conductor
All Aluminum Alloy Conductors ASTM Standard Aluminum Bare Conductor
IEC 61089 Standard Aluminium Conductor Alloy Reinforced Acar
Popular AAAC Conductor Products
AAAC Conductor Cable-All Aluminum Alloy Conductor
AAAC Conductor ASTM B399 Bare Aluminium Alloy 6201-T81
IEC61089 All Aluminum Alloy Condcutor AAAC 500
German Sizes DIN48201 All Aluminum Alloy Condcutor AAAC 70mm2
Aluminium Alloy Conductor/Electric Cable AAAC Conductor 16-1250mm2
Hot Sale Bare Stranded Overhead Alloy Aluminum AAAC Cable
Popular High Quality ASTM B399 Standard AAAC Conductor Products
Popular jpcable99 Products
CSA Standard Aluminum Conductor Steel Reinforced ACSR Conductor
Hot Seller PVC Insulated and Sheathed Power Cable
Stranded (ACS) Aluminum Clad Steel Wire
4core 25mm2 Copper Conductor PVC Insulated Cable
Abc Aerial Bundled Overhead Cable
Copper Cable Multi-Cores Control Cable.
Tags: AAAC, AAAC Conductor, High Quality ASTM B399 Standard AAAC Conductor, jpcable99