High Quality Overhead Insulated Cable (0.6/1KV) ABC Cable
High Quality Overhead Insulated Cable (0.6/1KV) ABC Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Application
The assembled insulated conductor shall be suitable for use in a system having a standard operating voltage not exceeding 600/1000V. The cores of an aerial bundled conductor shall be laid-up with a left-hand lay. The length of lay shall be 55-75 times the diameter of a phase conductor.
Construction
The conductors shall be stranded circular and, except where otherwise stated, shall comply with all the requirement for class 2 compacted stranded circular conductors of SANS 1411-1.
Specification:
| (1)Self-supporting | |||||||||||
| Phase | Phase | Phase | Approx.Overall Diameter | Min.Bending Radius | Max. D.C. Resistance of Conductor at 20 | ||||||
| AAC+UV-XLPE | Compact Conductor | UV-XLPE Insulation | |||||||||
| No.X Normal Cross Section of Cores | No.of Al Wires | Overall Diameter | Thickness | Min. | Diameter | ||||||
| No. X mm 2 | – | mm | mm | mm | mm | mm | kN | ohm/km | |||
| 4 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 17.42 | 2.07 | 1.91 | |||
| 4 X 25 | 7 | 6 | 1.4 | 1.16 | 8.8 | 21.3 | 3.3 | 1.2 | |||
| 4 X 35 | 7 | 7 | 1.6 | 1.34 | 10.2 | 24.68 | 4.5 | 0.868 | |||
| 4 X 50 | 7 | 8.3 | 1.6 | 1.34 | 11.5 | 27.83 | 6.2 | 0.641 | |||
| 4 X 70 | 19 | 10 | 1.8 | 1.52 | 13.6 | 32.91 | 8.9 | 0.443 | |||
| 4 X 95 | 19 | 11.6 | 1.8 | 1.52 | 15.2 | 36.78 | 12.3 | 0.32 | |||
| 4 X 120 | 19 | 13 | 1.8 | 1.52 | 16.6 | 40.17 | 15.6 | 0.253 | |||
| 4 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 44.04 | 19.2 | 0.206 | |||
| 3 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 15.55 | 2.07 | 1.91 | |||
| 3 X 25 | 7 | 6 | 1.4 | 1.16 | 8.8 | 19.01 | 3.3 | 1.2 | |||
| 3 X 35 | 7 | 7 | 1.6 | 1.34 | 10.2 | 22.03 | 4.5 | 0.868 | |||
| 3 X 50 | 7 | 8.3 | 1.6 | 1.34 | 11.5 | 24.84 | 6.2 | 0.641 | |||
| 3 X 70 | 19 | 10 | 1.8 | 1.52 | 13.6 | 29.38 | 8.9 | 0.443 | |||
| 3 X 95 | 19 | 11.6 | 1.8 | 1.52 | 15.2 | 32.83 | 12.3 | 0.32 | |||
| 3 X 120 | 19 | 13 | 1.8 | 1.52 | 16.6 | 35.86 | 15.6 | 0.253 | |||
| 3 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 39.31 | 19.2 | 0.206 | |||
| 2 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 14.4 | 2.07 | 1.91 | |||
| 2 X 25 | 7 | 6 | 1.4 | 1.16 | 8.8 | 17.6 | 3.3 | 1.2 | |||
| 2 X 35 | 7 | 7 | 1.6 | 1.34 | 10.2 | 20.4 | 4.5 | 0.868 | |||
| 2 X 50 | 7 | 8.3 | 1.6 | 1.34 | 11.5 | 23 | 6.2 | 0.641 | |||
| 2 X 70 | 19 | 10 | 1.8 | 1.52 | 13.6 | 27.2 | 8.9 | 0.443 | |||
| 2 X 95 | 19 | 11.6 | 1.8 | 1.52 | 15.2 | 30.4 | 12.3 | 0.32 | |||
| 2 X 120 | 19 | 13 | 1.8 | 1.52 | 16.6 | 33.2 | 15.6 | 0.253 | |||
| 2 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 36.4 | 19.2 | 0.206 | |||
| 1 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 7.2 | 2.07 | 1.91 | |||
| 1 X 25 | 7 | 6 | 1.4 | 1.16 | 8.8 | 8.8 | 3.3 | 1.2 | |||
| 1 X 35 | 7 | 7 | 1.6 | 1.34 | 10.2 | 10.2 | 4.5 | 0.868 | |||
| 1 X 50 | 7 | 8.3 | 1.6 | 1.34 | 11.5 | 11.5 | 6.2 | 0.641 | |||
| 1 X 70 | 19 | 10 | 1.8 | 1.52 | 13.6 | 13.6 | 8.9 | 0.443 | |||
| 1 X 95 | 19 | 11.6 | 1.8 | 1.52 | 15.2 | 15.2 | 12.3 | 0.32 | |||
| 1 X 120 | 19 | 13.01 | 1.8 | 1.52 | 16.6 | 16.6 | 15.6 | 0.253 | |||
| 1 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 18.2 | 19.2 | 0.206 | |||
| (2) Phase + Supporting | |||||||||||
| Phase | Supporting | Phase | Supporting | Approx. Overall Diameter | |||||||
| AAC+UV-XLPE | AAAC+UV-XLPE | Compact Conductor | UV-XLPE Insulation | Conductor | UV-XLPE Insulation | ||||||
| No.X Normal Cross Section of Cores | No.X Normal Cross Section of Cores | No.of Al Wires | Overall Diameter | Normal Thickness | No./Dia.of Al. Wire | Normal Thickness | |||||
| No. X mm 2 | No. X mm 2 | – | mm | mm | No./mm | mm | mm | ||||
| 3 X 16 | 1 X 54.6 | 7 | 4.8 | 1.2 | 7/3.15 | 1.6 | 20.72 | ||||
| 3 X 25 | 1 X 54.6 | 7 | 6 | 1.4 | 7/3.15 | 1.6 | 23.63 | ||||
| 3 X 35 | 1 X 54.6 | 7 | 7 | 1.6 | 7/3.15 | 1.6 | 26.17 | ||||
| 3 X 50 | 1 X 54.6 | 7 | 8.3 | 1.6 | 7/3.15 | 1.6 | 28.53 | ||||
| 3 X 70 | 1 X 54.6 | 19 | 10 | 1.8 | 7/3.15 | 1.6 | 32.34 | ||||
| 3 X 95 | 1 X 54.6 | 19 | 11.6 | 1.8 | 7/3.15 | 1.6 | 35.24 | ||||
| 3 X 120 | 1 X 54.6 | 19 | 13 | 1.8 | 7/3.15 | 1.6 | 37.78 | ||||
| 3 X 150 | 1 X 54.6 | 19 | 14.6 | 1.8 | 7/3.15 | 1.6 | 40.69 | ||||
| 3 X 16 | 1 X 70 | 7 | 4.8 | 1.2 | 7/3.5 | 1.6 | 21.36 | ||||
| 3 X 25 | 1 X 70 | 7 | 6 | 1.4 | 7/3.5 | 1.6 | 24.26 | ||||
| 3 X 35 | 1 X 70 | 7 | 7 | 1.6 | 7/3.5 | 1.6 | 26.8 | ||||
| 3 X 50 | 1 X 70 | 7 | 8.3 | 1.6 | 7/3.5 | 1.6 | 29.16 | ||||
| 3 X 70 | 1 X 70 | 19 | 10 | 1.8 | 7/3.5 | 1.6 | 32.97 | ||||
| 3 X 95 | 1 X 70 | 19 | 11.6 | 1.8 | 7/3.5 | 1.6 | 35.88 | ||||
| 3 X 120 | 1 X 70 | 19 | 13 | 1.8 | 7/3.5 | 1.6 | 38.42 | ||||
| 3 X 150 | 1 X 70 | 19 | 14.6 | 1.8 | 7/3.5 | 1.6 | 41.32 | ||||
| 3) Phase+Supporting+ Service Connection | |||||||||||
| Phase | Supporting | Service Connection | Phase | Supporting | Service Connection | Approx.Overall Diameter of Bundled Cable | |||||
| AAC+UV-XLPE | AAAC+UV-XLPE | AAC+UV-XLPE | Compact Conductor | UV-XLPE | Conductor | UV-XLPE | Compact Conductor | UV-XLPE | |||
| No.X Normal Cross Section of Cores | No.X Normal Cross Section of Cores | No.X Normal Cross Section of Cores | No.of Al.Wire | Overall Dia. | Normal | No./Dia.of Al. Wire | Normal | No. of Al. Wire | Overall Dia. | Normal | |
| Thickness | Thickness | Thickness | |||||||||
| No. X mm 2 | No. X mm 2 | No. X mm 2 | – | mm | mm | No./mm | mm | – | mm | mm | mm |
| 3 X 16 | 1 X 54.6 | 1 X 25 | 7 | 4.8 | 1.2 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 27.05 |
| 3 X 25 | 1 X 54.6 | 1 X 25 | 7 | 6 | 1.4 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 30.25 |
| 3 X 35 | 1 X 54.6 | 1 X 25 | 7 | 7 | 1.6 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 33.05 |
| 3 X 50 | 1 X 54.6 | 1 X 25 | 7 | 8.3 | 1.6 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 35.65 |
| 3 X 70 | 1 X 54.6 | 1 X 25 | 19 | 10 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 39.85 |
| 3 X 95 | 1 X 54.6 | 1 X 25 | 19 | 11.6 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 43.05 |
| 3 X 120 | 1 X 54.6 | 1 X 25 | 19 | 13 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 45.85 |
| 3 X 150 | 1 X 54.6 | 1 X 25 | 19 | 14.6 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 49.05 |
| 3 X 16 | 1 X 54.6 | 2 X 25 | 7 | 4.8 | 1.2 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 27.05 |
| 3 X 25 | 1 X 54.6 | 2 X 25 | 7 | 6 | 1.4 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 30.25 |
| 3 X 35 | 1 X 54.6 | 2 X 25 | 7 | 7 | 1.6 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 33.05 |
| 3 X 50 | 1 X 54.6 | 2 X 25 | 7 | 8.3 | 1.6 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 35.65 |
| 3 X 70 | 1 X 54.6 | 2 X 25 | 19 | 10 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 39.85 |
| 3 X 95 | 1 X 54.6 | 2 X 25 | 19 | 11.6 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 43.05 |
| 3 X 120 | 1 X 54.6 | 2 X 25 | 19 | 13 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 45.85 |
| 3 X 150 | 1 X 54.6 | 2 X 25 | 19 | 14.6 | 1.8 | 7/3.15 | 1.6 | 7 | 6 | 1.4 | 49.05 |
FACTORY VIEW
QC& TESTING MACHINE
CERTIFICATES:
LOADING DETAILS
CUSTOMER VISIT
FAQ
1. How many years has Henan Jiapu Cable Group been in production?
Founded in October 1998 by Mr. Gu, our facility has three separate manufacturing workshops within its 100, 000-sq. -ft. Building. In 2012, we operates in a new 666, 000 sq. Foot state-of-the-art facility in Xiaodian Industry Park., Xinxiang, Henan, China
2. What kinds of products does Jiapu Cable manufacture?
1)Bare Conductor, such as AAC, AAAC, ACSR, ACAR, AACSR, ACSR/AW and so on;
2)Aerial Bundled Cable (1kV-35kV ), such as Duplex, Triplex, Quadruplex Drop Wires and so on;
3)PVC Insulated (Flexible ) Wire;
4) PVC Insulated and Sheathed (Armoured) Power Cable;
5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;
6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on;
3. What kind of certifications do you have?
SABS, CE, ISO9001-2000, SGS
4. Which markets do you involve mainly in?
Our products have been exported mainly to Africa, Middle East, South-east Asia, South America, Central America, North America, Europe, Australia, etc.
5. Which standards do you comply with when you produce the electrical wires and cables?
We are able to produce electrical wires and cables based on GB, JB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA, etc. Meanwhile, we can design and manufacture the cables according to the samples and technical specification the customer supply.
6. What is the min. Order quantity?
It depends on the type and size of electrical wires and cables. For some small electrical wires, 100 meters can be accepted. But for the power cables with medium or high voltage, that should comply with the property of installed equipments. Anyhow, we will try our best to solve the problem and meet with the requirement If you have special request.
7. What is the production capacity per week or per month?
For the bare conductor, we can finish 3000 tons within one month. For power cables, that depends on the type and size. The total output value per month is approx. USD3, 000, 000.00 for insulated aluminum cables and that is approx. USD8, 000, 000.00 for insulated copper cables.
8. Do you supply the customers with installation service in foreign country?
We don’t have professional installation teams in foreign country. But if that is necessary, we will recommend our partners to cooperate with you.
We are China High Quality Overhead Insulated Cable (0.6/1KV) ABC Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular ABC Cable Products
Insulated ABC Cable Overhead Aluminum Electric Cable
High Quality 600/1000V ABC Aerial Bundled Cables to HD 626 S1 (AL/XLPE)
ABC Cable Duplex #1/0 Bull AAC/PE+ACSR
Duplex Service Drop, Aerila Bundle ABC Cable
0.6-10kv Aluminum/Copper Overhead ABC Power Cable
ABC Cable, Aerial Bundle Cable, ACSR, Electrical Overhead Cable
Popular jpcable99 Products
IEC Standard High Quality Bare Conductor Aacsr Conductor
ACSR Rabbit Bare Conductor (Aluminium Conductor steel Reinforced)
Low Voltage 0.6/1kv PVC Power Cable
High Quality 70mm2/54.6mm2 Aerial Bundled Cable
2.5mm2 H05V-K PVC Insulated Wire
Popular Overhead Cable Products
11kv ABC Cable by Manumfactory of Henan Jinshui Cable
Overhead Service Aerial Bundled Cable ABC Cable
Duplex Triplex Quadruplex Aerial Bunched/Bundled Overhead XLPE Insulated Aluminum ABC Cable
Power Transmission Lines AAC Bare Conductor with High Quality
AAAC ACSR AAC with Safe Standard and Certificate
10kv Aluminum Core Light Duty XLPE Insulated Cable for Overhead
Popular Overhead Insulated Cable Products
2X16mm2 Al XLPE ABC Cable (Aerial Bundled Cable)
110kv 70mm2 95mm2 Aluminum XLPE Insulated Power Cable
Triplex Overhead Service Drop Cable Duplex. 1X16+16mm2 Power Cable for Use Overhead
Bt Connection Cable XLPE Insulated 2X16mm2 Aluminum Twisted Aerial Cable
Cable Preassemble Bt 3X70+54.6+2X16mm2 Alu Aerial Bundled Cables
Tags: ABC Cable, jpcable99, Overhead Cable, Overhead Insulated Cable