High Quality Rdk Type-- Autosectionalizer

China 
                        High Quality Rdk Type-- Autosectionalizer
                      manufacture and supplier

High Quality Rdk Type-- Autosectionalizer image

Get Latest Price Request a quote

Quick Details

High Quality Rdk Type– Autosectionalizer

RDK-

VDE

Discoloration

F

Spiral

High Voltage

Current Fuse

High

Outdoor Expulsion Drop-out Type

HAIVOL

Carton

27kv 100/200a

China

8535100000

Product Details

Introduction

Operational principle

The current transformer built in the cutout sectionalizer can detect the current of the main circuit and send the output to the electronic control for digital handling. When a fault occurs, the upstream recloser (or circuit breaker) opens, the circuit loses voltage and the current is lower than 300mA, the electronic controller can remember this opening time as a "count". As it accumulate the presetting number (1 to 4), the sectionalizer will automatic trips within 180ms of fault interruption to isolate fault. Then the upstream recloser (or circuit breaker) closes to restore power supply to the healthy section of the system to limit outage scope and protect the main feeder in service. If the fault is temporary and is cleared before the sectionalizer counter reaches the presetting number, the sectionalizer remains closed and resets to its original state after its reset time expires.

Counts
The number of counts differentiates real faults from transient faults. When the preset number of countsis registered, the electronic sectionalizer willoperate.
The sectionalizer can be set to 1, 2, 3, 4 counts. It registers a count when a current dead time exceeding200 milliseconds occurs, immediately after a current pick up. This ensures the sectionalizer only registers acount when a recloser has tripped due to a faultcurrent.
The count setting should be one count less than the immediate upstreamrecloser.

Pick upcurrent
The pick up current is the threshold, which must be exceeded in order to register a count. The pick up requires a minimum fault pulse that is 10% greater than the pick up current setting and is longer than 20 milliseconds in duration.

Resetting
Theelectronicsectionalizerwillresetitselfduringthedropoutoperation.Do not need remove the unit from itsmount using a hook stick and reset itmanually.

Service conditions
1.The ambient air temperature is not above 55ºC or below-40ºC.
2.Theaveragevalueoftheambienttemperature,measuredoveraperiodof24h,doesnotexceed 25ºC.
3.The altitude does not exceed 1000 m(3300ft).
4.The wind speed does not exceed 34 m/s (corresponding to 700 Pa on cylindricalsurfaces).
5.The ice coating does not exceed1mm.
6.Thesectionalizershouldnotapplytothoseflammable,explosive,corrosiveandseverevibrationconditions. As to other service conditions not covered in the manual, please contact and consult with the manufacturerfor detailinformation.

Designator and itsmeaning

Technical data
Rated actuating current: 8 to400A
Reclaim time: 20±5%s
Operation counts:1-4
Sensitivity of pick up current:±10%
Max. load current prior to operation: 0.3A
Min. recloser dead time: 500ms
Min. duration of fault pulse:10ms

We are China High Quality Rdk Type-- Autosectionalizer manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Drop out Fuse Products

12kv-15kv Model Hv-1 Outdoor Fuse Cutout

High Voltage Outdoor Fuse Cutout

RW12-15/100A-200A 15kv Outdoor High Voltage Porcelain Drop-out Fuse with High Quality

Use for Outdoor Fuse Cutout Expulsion Fuse Link

Cutout / Drop out Fuse (Silicon Type) 15kv

Outdoor Expulsion Drop-out Type Distribution Fuse Cutout Series 11kv-36kv

Popular Fuse Cutout Products

Outdoor Expulsion Drop-out Type Distribution Fuse Cutout Series

12kv High Voltage Fuse Cutout for Overhead Line

11kv-36kv Porcelain Housed Cutout Fuse / Dropout Fuse with IEC Standard

18kv High Quality Polymer Fuse Cutout for Overhead Line

24kv Polymer Housed Cutout Fuse CFS-3R-24-540

Fuse Cutout, Drop out Fuses 21kv 100A

Popular Outdoor Fuse Cutout Products

15kv 100A/200A Polymer Expulsion Fuse Cutout

Outdoor Expulsion Drop-out Type Distribution Fuse Cutout Series

Fuse Cutout 15kv Composite Type

Outdoor Expulsion Drop-out Type Distribution Fuse Cutout Series

Outdoor Expulsion Drop-out Type Distribution Fuse Cutout

Outdoor Polymeric Expulsion Drop-out Type Distribution Fuse Cutout

Popular people Products

(FQX1-25/135) Electrified Railways Composite Insulator

11kv High Quality Breaking Capacity Fuse Cutout

Porcelain Fuse Link Fuse Cutout for Overhead Line

24kv Outdoor Expulsion Drop-out Type Loadbreak Fuse Cutout

High Voltage Composite Porcelain Insulators

24kv 100kn Electrified Railways Composite Insulators

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION