High Strength and Capacity ACSR Low Loss (ACSAR-LL) Zebra,

China 
                        High Strength and Capacity ACSR Low Loss (ACSAR-LL) Zebra,
                      manufacture and supplier

High Strength and Capacity ACSR Low Loss (ACSAR-LL) Zebra, image

Get Latest Price Request a quote

Quick Details

High Strength and Capacity ACSR Low Loss (ACSAR-LL) Zebra,

ACSR-LL Zebra

Huatong

ACSR

ISO, CCC, CE, RoHS, UL, VDE

Aluminum

Round Wire

None

Bare

DC Cable

Low and Medium Voltage Cable

Overhead

IEC,ASTM,BS,DIN,GB/T

on-Time

Low Voltage, Medium Vlotage High Voltage

Manufacturer

One Year

15 Days

Power Station,Transmission & Distribution Line

Free Sample Is Avaliable

HuaTong

Wooden Drum; Wooden Steel Drum; All Steel Drum

ACSR-LL Zebra

China

7649100000

Product Details

1. Bare Overhead Conductor ACSR, AAC, AAAC Conductor
(1). What are Aluminium Conductors used for?
Aluminium Conductors are predominantly used in Overhead Line applications and for primary and secondary power distribution.
The higher strength ACSR conductors are used for river crossings, overhead earth wires, and installations involving extra long spans. The advantage of ACSR is that it has high tensile strength and is lightweight, which means over longer spans it needs less supports. ACSR is available with varying percentages of steel core to achieve different strengths. One of the advantages of this conductor in particular is that the desired strength can be achieved without a loss of ampacity.
 
AAC is used mainly in urban areas where the spacing is short and the supports are closer together. The advantage of AAC conductors is that they have a high degree of corrosion resistance; for this reason they are used extensively in coastal areas. AAC Conductors were developed as a consequence of the galvanic corrosion that ACSR conductors are susceptible to.
 
AAAC is used as bare overhead conductor for power transmission and distribution lines on aerial circuits that require larger mechanical resistance than AAC. AAAC also has better sag characteristics and a better strength to weight ratio than AAC. AAAC Cables have lower weight per unit length and slightly lower resistance per unit length than ACSR.
 
(2). What is the difference between ACSR, AAC and AAAC Conductors?
The biggest difference between AAC, AAAC, and ACSR conductors are the materials they are constructed from. AAC is manufactured from electrolytically refined aluminium with a 99.7% minimum purity, AAAC is made from an Aluminium alloy, and ACSR contains a combination of Aluminium reinforced with Steel.
 
The second factor that differentiates the three cables is their resistance to corrosion, which is important for the longevity of the cable. ACSR has a poorer resistance to corrosion, as it contains steel, which is prone to rust. AAAC and AAC have a better corrosion resistance, due to the fact that they are largely or completely aluminium.
 
In an ACSR the galvanised steel core carries the mechanical load and the high purity aluminium carries the current. These utilise the lower thermal expansion coefficient of steel compared to aluminium, which the aluminium based conductors AAC and AAAC are unable to do.

2. Type & Designation

Type Description No. of Wire Section Area (mm2)
AAC All Aluminum Conductor 7~127 16~1500
AAAC All Aluminum Alloy Conductor 7~91 17~1300
ACSR Aluminum Conductors Steel Reinforced 7~103 16~1250
AACSR Aluminum Alloy Conductors Steel Reinforced 7~103 16~1250
ACAR/AW Aluminum Conductors Aluminum Alloy Reinforced 7~103 16~1250
ACSW/S Aluminum Conductor Aluminum Clad Steel Wire/Strand 7~103 16~1250
GSW Galvanized Steel Wire 3/2.64~37/4.55 16.41~765.99

3 .Applications
Conductor(AAC,AAAC and ACSR) have been widely used in power transmission lines with various voltage levels,because they have such good characteristics as simple structure,convenient installation and maintenance,low cost large transmission capacity.And they are also suitable for laying across rivers valleys and the places where special geographical features exist.
2.Service Performance
(1).The permissible long-time operating temperature for aerial conductor is 70oC.
(2).Under the circumstance that rare climate is occuring and ice coverage rate low in heavy ice area,the biggest stress of cable at the lowest point of the sag should not exceed 60% of the short-time destructive power.
(3).When connecting conductors,the conductor beside the connecting tube cant be prominent.Otherwise,the force on the operating conductors will be unbalanced.After connectors are install,the connecting tube should be painted by moisture-proof varnish in order to protect it from corrosion.
(4).Under installaion,the arc downing stress of all the conductors should be the same.With in the permissible distance of crossing buildings or dropping to the ground,the stress can be 10-15% higher than regular stress.
 
4.Technical details
 

AAC Technical Characteristics Based on Standard DIN 48201 / DIN EN50182
 

Code number Area Number of wires Wire    diameter Conductor diameter Linear mass Rated strength D.C. resistance at 20oC
mm2 No. mm mm kg/km kN Ω/km
16 15.9 7 1.7 5.1 43.4 3.02 1.7986
25 24.2 7 2.1 6.3 66.3 4.36 1.1787
35 34.4 7 2.5 7.5 93.9 6.01 0.8317
50 49.5 7 3 9 135.2 8.41 0.5776
50 48.3 19 1.8 9 132.9 8.94 0.5944
70 65.8 19 2.1 10.5 180.9 11.85 0.4367
95 93.3 19 2.5 12.5 256.3 16.32 0.3081
120 117 19 2.8 14 321.5 19.89 0.2456
150 147.1 37 2.25 15.8 405.7 26.48 0.196
185 181.6 37 2.5 17.5 500.9 31.78 0.1588
240 242.5 61 2.25 20.3 671.1 43.66 0.1193
300 299.4 61 2.5 22.5 828.5 52.4 0.0966

 
ACSR Technical Characteristics Based on Standard BS 215-2  
 

Code name Nominal aluminium area Stranding and wire    diameter Sectional area of aluminium Total sectional area Approx. overall diameter Approx. mass Calculated D.C. resistance at 20oC Calculated breaking load
Al Steel
mm2 No./mm mm2 mm2 mm kg/km Ω/km kN
RABBIT 50 6/3.35 1/3.35 52.88 61.7 10.05 214 0.5426 18.35
DOG 100 6/4.72 7/1.57 105 118.5 14.15 394 0.2733 32.7
WOLF 150 30/2.59 7/2.59 158.1 194.9 18.13 726 0.1828 69.2
DINGO 150 18/3.35 1/3.35 158.7 167.5 16.75 506 0.1815 35.7
LYNX 175 30/2.79 7/2.79 183.4 226.2 19.53 842 0.1576 79.8
ZEBRA 400 54/3.18 7/3.18 428.9 484.5 28.62 1621 0.0674 131.9

 

5. About Us

6. Why Choose Us– Huatong Cable Inc
(1)More than 30 years experience.
(2)100,000m² factory,200 staffs,annual output 100,000 metic tons.
(3)Sound Quality Control
   1) Material inspection;
   2) manufacturing inspection;
   3) Finished products inspection;
   4) Inspection before delivery.
   5) Third party inspection.
   6) Inspection of storage at port of departure.
(4)ISO Certificated.
(5)Plenty of material and lobor gurantee the delivery prompt and price competitive.
(6)24/7 service.

We are China High Strength and Capacity ACSR Low Loss (ACSAR-LL) Zebra, manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular ACSR Low Loss (ACSR-LL) Products

  • No related articles
  • Popular ACSR Low Loss (ACSR-LL) Zebra Products

  • No related articles
  • Popular High Strength ACSR Low Loss Zebra Products

  • No related articles
  • Popular huatongcable Products

    10mm2 Aluminum Core XLPE Inuslated Triplex ABC Cable 0.6/1kv

    Concentric Neutral Cable 2*6wg

    BS 215 Dingo Lion Bear Sheep ACSR