• Designed and manufactured to meet or exceed the requirements of IEC 62271
• Accommodates many customer specific requirements where they differ from IEC
• Silicone insulators with minimum of 25mm/kV creepage
• Plated HDHC copperwork for longevity of life
• Available in 12/15.5 kV, 24 kV and 36 kV voltage ranges
• Standard current ratings of up to 1250 A
• Short time withstand current of 25 kA rms for 3 seconds with 62.5 kA peak
• Standard fault make capacity of 3 kA rms with 7.5 kA peak
• Compact and robust construction
• Suitable for horizontal and vertical mounting
• Suitable for mounting pole top (above the line) or underslung (below the line)
Accessories
• Low level operating handle, high level hookstick mechanism or Independent Manual Spring (IMS) operating mechanism
• 10k A rms 25k A peak fault make capacity when combined with IMS mechanism
• Load break devices with breaking capacity of 630 A for on-load use
• Can be fitted with motor drive/RTU for remote operation
• Earth blades rated at 25 kA 3 sec for fitting to either side
• Self-latching shootbolt on hookstick mechanism can be fitted with safety lock flap for lockoff and point of isolation
• Mounting steelwork to suit single or double pole construction
• Can be fitted with drop out expulsion fuses to form a combination switch fuse
Main Technical Specification
Sheet 1
| No. | Item | Unit | Data | |||
| 1 | Rated voltage | kV | 12 | 24 | 36 | |
| 2 | Rated frequency | Hz | 50/60 | |||
| 3 | Rated current | A | 200/400/630 | |||
| 4 | Rated short circuit withstand current (1S) | kA | 20 | |||
| 5 | Rated peak withstand current (1S) | kA | 50 | |||
| 6 | Rated making current | kA | 31.5-50 | |||
| 7 |
Rated insulation level(HV) |
lightning impulse | kV |
75/85 | 125/145 | 170/195 |
| Power frequency withstand | 45 | 55/75 | 75/100 | |||
| 8 |
Rated short circuit breaking capacity cos. Φ(0.7) Without maintenance of contacts |
—————————— | ||||
| – for active circuits |
20 breakings | A |
630 | 630 | 400 | |
| 30 breakings | 400 | 400 | 300 | |||
| 40 breakings | 300 | 300 | 250 | |||
| 50 breakings | 250 | 250 | 170 | |||
| 75 breakings | 170 | 170 | 160 | |||
| 120 breakings | 110 | 110 | 110 | |||
| 200 breakings | 65 | 65 | 65 | |||
| 280 breakings | 50 | 50 | 50 | |||
Sheet 2
| No. | Item | Unit | Data | ||
| 1 | Rated voltage | kV | 12 | 24 | 36 |
| 9 | For ring circuits breaking capacity | A | 630 | 400 | 250 |
| 10 | Rated breaking capacity of transformer | A | 50 | ||
| 11 | Rated breaking capacity of cable charging | A | 11 | ||
| 12 | Rated breaking capacity of earthing fault | A | 56 | ||
We are China High Voltage Outdoor Air Break Switch manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Air Insulated Load Break Switch Products
Popular Load Break Switch Products
11kv 33kv 63A Isolator Switch, DC Isolator Switch
35kv Rmu Indoor New Type Sf6 Air Load Break Switch
12kv Air Insulated Load Break Switch
Tap-changer is suitable for single-phase oil-immersed power transformers with frequency of 60HZ
De-energized cage-form tap-changer(66kv and below) for transformer
Indoor High Voltage 12kv Fuse Combination Vacuum Load Switch Protection Device
Popular Outdoor Break Switch Products
Gang Operated Air Break Switches
Popular silverstone-electric Products
Hot Sale 11kv Steel Making Electric Arc Furnace Transformer
11kv Type Scb10-630~3150kVA Dimension with Protection Enclosure
11kv 30~1000kVA Dimensions with Protection Enclosure
ANSI Type Porcelain Strain Insulator
Single-Phase Overhead Self Protected Pole Mounted Distribution Transformers
ANSI Standard Composite Insulator Factory
Tags: Air Insulated Load Break Switch, Load Break Switch, Outdoor Break Switch, silverstone-electric