High Voltage Outdoor Fuse Cutout

China 
                        High Voltage Outdoor Fuse Cutout
                      manufacture and supplier

High Voltage Outdoor Fuse Cutout image

Get Latest Price Request a quote

Quick Details

High Voltage Outdoor Fuse Cutout

HAIVOL

VDE

Discoloration

F

Spiral

High Voltage

Current Fuse

High

Outdoor Expulsion Drop-out Type

HAIVOL

Carton

27kv 100/200a

China

8535100000

Product Details

Introduction

Operational principle

The current transformer built in the cutout sectionalizer can detect the current of the main circuit and send the output to the electronic control for digital handling. When a fault occurs, the upstream recloser (or circuit breaker) opens, the circuit loses voltage and the current is lower than 300mA, the electronic controller can remember this opening time as a "count". As it accumulate the presetting number (1 to 4), the sectionalizer will automatic trips within 180ms of fault interruption to isolate fault. Then the upstream recloser (or circuit breaker) closes to restore power supply to the healthy section of the system to limit outage scope and protect the main feeder in service. If the fault is temporary and is cleared before the sectionalizer counter reaches the presetting number, the sectionalizer remains closed and resets to its original state after its reset time expires.

Counts
The number of counts differentiates real faults from transient faults. When the preset number of countsis registered, the electronic sectionalizer willoperate.
The sectionalizer can be set to 1, 2, 3, 4 counts. It registers a count when a current dead time exceeding200 milliseconds occurs, immediately after a current pick up. This ensures the sectionalizer only registers acount when a recloser has tripped due to a faultcurrent.
The count setting should be one count less than the immediate upstreamrecloser.

Pick upcurrent
The pick up current is the threshold, which must be exceeded in order to register a count. The pick up requires a minimum fault pulse that is 10% greater than the pick up current setting and is longer than 20 milliseconds in duration.

Resetting
Theelectronicsectionalizerwillresetitselfduringthedropoutoperation.Do not need remove the unit from itsmount using a hook stick and reset itmanually.

Service conditions
1.The ambient air temperature is not above 55ºC or below-40ºC.
2.Theaveragevalueoftheambienttemperature,measuredoveraperiodof24h,doesnotexceed 25ºC.
3.The altitude does not exceed 1000 m(3300ft).
4.The wind speed does not exceed 34 m/s (corresponding to 700 Pa on cylindricalsurfaces).
5.The ice coating does not exceed1mm.
6.Thesectionalizershouldnotapplytothoseflammable,explosive,corrosiveandseverevibrationconditions. As to other service conditions not covered in the manual, please contact and consult with the manufacturerfor detailinformation.

Designator and itsmeaning

Technical data
Rated actuating current: 8 to400A
Reclaim time: 20±5%s
Operation counts:1-4
Sensitivity of pick up current:±10%
Max. load current prior to operation: 0.3A
Min. recloser dead time: 500ms
Min. duration of fault pulse:10ms

Participate in the exhibition pictures

We are China High Voltage Outdoor Fuse Cutout manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Drop out Fuse Products

Outdoor Expulsion Drop-out Type Distribution Fuse Cutout Series

High Quality Drop-out Fuse Cutout with Load Cutout

15kv Outdoor Expulsion Drop-out Type Distribution Fuse Cutout

15kv 100A/200A Polymer Expulsion Fuse Cutout

12kv-15kv Fuse Switch

High Quality Rdk Type-- Autosectionalizer

Popular Fuse Cutout Products

15kv High Quality Polymer Fuse Cutout for Overhead Line

11-36kv Outdoor Polymer High Voltage Drop-out Fuse Cutout

Metal Anchor Clamp

RW12-15/100A-200A 15kv Outdoor High Voltage Porcelain Drop-out Fuse with High Quality

RW11 100A/200A Composite Slicone Rubber Dropout Fuse/High Voltage Fuse Cutout

30kv Polymer Fuse Cutout Insulators

Popular Outdoor Fuse Cutout Products

High Voltage Porcelain Fuse Switch Disconnector

Outdoor Expulsion Drop-out Type Distribution Fuse Cutout Series

12kv Outdoor Expulsion Drop-out Type Distribution Drop out Fuse Cutout

33-36kv Porcelain Fuse Cutout Drop-out Fuse Cutout

15kv 200A Outdoor High Voltage Fuse Cutout

Brass Casting Fitting for Drop Fuse Cutout

Popular people Products

220kv High Voltage Metal-Oxide Surge Arrester

90kv Metal Oxide Lightning Arrester for Overvoltage Protection

Cable Joint Kits

27kv Outdoor Drop out Type Loadbreak Fuse Cutout

High Quality Outdoor Tension Type Composite Insulator

Aluminium Fitting APG Clamp/Export Terminal

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION