High Voltage Outdoor Fuse Cutout
High Voltage Outdoor Fuse Cutout image
Get Latest Price Request a quote
Quick Details
Product Details
Operational principle
The current transformer built in the cutout sectionalizer can detect the current of the main circuit and send the output to the electronic control for digital handling. When a fault occurs, the upstream recloser (or circuit breaker) opens, the circuit loses voltage and the current is lower than 300mA, the electronic controller can remember this opening time as a "count". As it accumulate the presetting number (1 to 4), the sectionalizer will automatic trips within 180ms of fault interruption to isolate fault. Then the upstream recloser (or circuit breaker) closes to restore power supply to the healthy section of the system to limit outage scope and protect the main feeder in service. If the fault is temporary and is cleared before the sectionalizer counter reaches the presetting number, the sectionalizer remains closed and resets to its original state after its reset time expires.
Counts
The number of counts differentiates real faults from transient faults. When the preset number of countsis registered, the electronic sectionalizer willoperate.
The sectionalizer can be set to 1, 2, 3, 4 counts. It registers a count when a current dead time exceeding200 milliseconds occurs, immediately after a current pick up. This ensures the sectionalizer only registers acount when a recloser has tripped due to a faultcurrent.
The count setting should be one count less than the immediate upstreamrecloser.
Pick upcurrent
The pick up current is the threshold, which must be exceeded in order to register a count. The pick up requires a minimum fault pulse that is 10% greater than the pick up current setting and is longer than 20 milliseconds in duration.
Resetting
Theelectronicsectionalizerwillresetitselfduringthedropoutoperation.Do not need remove the unit from itsmount using a hook stick and reset itmanually.
Service conditions
1.The ambient air temperature is not above 55ºC or below-40ºC.
2.Theaveragevalueoftheambienttemperature,measuredoveraperiodof24h,doesnotexceed 25ºC.
3.The altitude does not exceed 1000 m(3300ft).
4.The wind speed does not exceed 34 m/s (corresponding to 700 Pa on cylindricalsurfaces).
5.The ice coating does not exceed1mm.
6.Thesectionalizershouldnotapplytothoseflammable,explosive,corrosiveandseverevibrationconditions. As to other service conditions not covered in the manual, please contact and consult with the manufacturerfor detailinformation.
Designator and itsmeaning
Technical data
Rated actuating current: 8 to400A
Reclaim time: 20±5%s
Operation counts:1-4
Sensitivity of pick up current:±10%
Max. load current prior to operation: 0.3A
Min. recloser dead time: 500ms
Min. duration of fault pulse:10ms
Participate in the exhibition pictures
We are China High Voltage Outdoor Fuse Cutout manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Drop out Fuse Products
Cutout / Drop out Fuse (Silicon Type) 15kv
High Voltage Porcelain Cut out Fuse Key
Outdoor Expulsion Drop-out Type Distribution Fuse Cutout Series
High Voltage Drop-out Fuse Cutout
Outdoor Polymeric Expulsion Drop-out Type Distribution Fuse Cutout
RW3-10kv Drop-out Fuse Cutout Outdoor High Voltage
Popular Fuse Cutout Products
12ka Outdoor High Voltage Fuse Cutout
High Voltage Dropout Fuse or Fuse Cutout (Vc-12) , Silicon Fuse Cutout, Fuse Cutout
Electrical Polymeric Insulator for Drop Fuse Cut out
Mpc400 Complete with All Accessories Except Fuse
36kv Fuse Cutout, Fuse, Drop out Fuse
Popular Outdoor Fuse Cutout Products
15kv Outdoor Expulsion Drop-out Type Loadbreak Fuse Cutout
30kv Outdoor Drop-out Type Loadbreak Fuse Cutout
27kv Outdoor Expulsion Drop-out Type Distribution Fuse Cutout
Composite Drop Fuse Cut out Insulator
Outdoor Expulsion Drop-out Type Distribution Fuse Cutout Series
Outdoor Expulsion Drop-out Type Distribution Fuse Cutout Series
Popular people Products
252kv Overhead Transmission Line Post Composite Insulator
30kv Outdoor Drop-out Type Loadbreak Fuse Cutout
72.5kv 70kn Long Rod Suspension Composite Insulators
15kv High Voltage Distribution Systems Disconnect Switch
Outdoor Vertical Porcelain Disconnector Switch
72kv Metal Oxide Lightning Arrester for Overvoltage Protection
Tags: Drop out Fuse, Fuse Cutout, Outdoor Fuse Cutout, people